Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Spherical nanoindentation stress–strain curves

Although indentation experiments have long been used to measure the hardness and Young's modulus, the utility of this technique in analyzing the complete elastic–plastic response of materials under contact loading has only been realized in the past few years – mostly due to recent advances in testing equipment and analysis protocols. This paper provides a timely review of the recent progress made in this respect in extracting meaningful indentation stress–strain curves from the raw datasets measured in instrumented spherical nanoindentation experiments. These indentation stress–strain curves have produced highly reliable estimates of the indentation modulus and the indentation yield strength in the sample, as well as certain aspects of their post-yield behavior, and have been critically validated through numerical simulations using finite element models as well as direct in situ scanning electron microscopy (SEM) measurements on micro-pillars. Much of this recent progress was made possible through the introduction of a new measure of indentation strain and the development of new protocols to locate the effective zero-point of initial contact between the indenter and the sample in the measured datasets. As a result, this has led to an important key advance in this field where it is now possible to reliably identify and analyze the initial loading segment in the indentation experiments.

36 MATERIALS SCIENCE↗

Material Science Image Analysis using Quant-CT in ImageJ

We introduce a computational analysis workflow to access properties of solid objects using nondestructive imaging techniques that rely on X-ray imaging. The goal is to process and quantify structures from material science sample cross sections. The algorithms can differentiate the porous media (high density material) from the void (background, low density media) using a Boolean classifier, so that we can extract features, such as volume, surface area, granularity spectrum, porosity, among others. Our workflow, Quant-CT, leverages several algorithms from ImageJ, such as statistical region merging and 3D object counter. It also includes schemes for bilateral filtering that use a 3D kernel, for parallel processing of sub-stacks, and for handling over-segmentation using histogram similarities. The Quant-CT supports fast user interaction, providing the ability for the user to train the algorithm via subsamples to feed its core algorithms with automated parameterization. Quant-CT plugin is currently available for testing by personnel at the Advanced Light Source and Earth Sciences Divisions and Energy Frontier Research Center (EFRC), LBNL, as part of their research on porous materials. The goal is to understand the processes in fluid-rock systems for the geologic sequestration of CO2, and to develop technology for the safe storage of CO2 in deep subsurface rock formations. We describe our implementation, and demonstrate our plugin on porous material images. This paper targets end-users, with relevant information for developers to extend its current capabilities.

97 MATHEMATICS AND COMPUTING↗

High- χ diblock copolymers containing poly(vinylpyridine- N -oxide) segments

Block copolymers exhibiting an enhanced segregation strength due to an underlying high Flory–Huggins interaction parameter (high χ) have attracted considerable attention because of their potential of forming microphase-separated domains with very small feature sizes (<10 nm) useful for next-generation lithography. Here, we report the synthesis, characterization, and self-assembly of poly(styrene)- block -poly(2-vinylpyridine N -oxide) (PS- b -P2VPNO) and poly(styrene)- block -poly(4-vinylpyridine N -oxide) (PS- b -P4VPNO) block copolymers. These PS- b -PVPNOs were obtained from the oxidation of their precursors, poly(styrene)- block -poly(2-vinylpyridine) (PS- b -P2VP) and poly(styrene)- block -poly(4-vinylpyridine) (PS- b -P4VP), respectively. The PS- b -PVPNOs exhibit an enhanced segregation as revealed by ordered cylindrical and lamellar structures in the sub-10 nm scale from copolymers with relatively low molecular weight. The morphologies and periodicities of the ordered structures were determined by small-angle X-ray scattering, while atomic-force microscopy was used to image the self-assembly in thin films. Estimates of the changes in disorder–order transition temperature and domain spacing are derived from a theory based on the effects of dipolar interactions. All the experimentally observed morphological changes resulting from the oxidation of P2VP and P4VP precursors can be qualitatively explained in terms of an increased dipole moment of vinylpyridine N -oxide segments. Therefore, our results demonstrate that PVPNO based block copolymers are versatile candidates toward nanopatterned structures with small feature sizes critical for the future microelectronics industry and beyond.

36 MATERIALS SCIENCE↗

Intermittency and lifetime of the 625 Hz quasi-periodic oscillation in the 2004 hyperflare from the magnetar SGR 1806-20 as evidence for magnetic coupling between the crust and the core

Quasi-periodic oscillations (QPOs) detected in the 2004 giant flare from SGR 1806-20 are often interpreted as global magneto-elastic oscillations of the neutron star. There is, however, a large discrepancy between theoretical models, which predict that the highest frequency oscillations should die out rapidly, and the observations, which suggested that the highest-frequency signals persisted for ∼100 s in X-ray data from two different spacecraft. This discrepancy is particularly important for the high-frequency QPO at ∼625 Hz. However, previous analyses did not systematically test whether the signal could also be present in much shorter data segments, more consistent with the theoretical predictions. Here, we test for the presence of the high-frequency QPO at 625 Hz in data from both the Rossi X-ray Timing Explorer (RXTE) and the Ramaty High Energy Solar Spectroscopic Imager (RHESSI) systematically both in individual rotational cycles of the neutron star, as well as averaged over multiple successive rotational cycles at the same phase. We find that the QPO in the RXTE data is consistent with being only present in a single cycle, for a short duration of ∼0.5 s, whereas the RHESSI data are as consistent with a short-lived signal that appears and disappears as with a long-lived QPO. Taken together, this data provides evidence for strong magnetic interaction between the crust and the core.

79 ASTRONOMY AND ASTROPHYSICS↗

Lidar Cloud Detection with Fully Convolutional Networks

In this contribution, we present a novel approach for segmenting laser radar (lidar) imagery into geometric time- height cloud locations with a fully convolutional network (FCN). We describe a semi-supervised learning method to train the FCN by: pre-training the classification layers of the FCN with image-level annotations, pre-training the en- tire FCN with the cloud locations of the MPLCMASK cloud mask algorithm, and fully supervised learning with hand-labeled cloud locations. We show the model achieves higher levels of cloud identification compared to the cloud mask algorithm implementation.

Cromwell, Erol LD↗

Characteristics of Multihole Collimator Gamma Camera Simulation Modeled Using MCNP5

This paper describes the characteristics of the multihole collimator gamma camera that is simulated using the combination of the Monte Carlo N-Particles Code (MCNP) version 5 and in-house software. The model is constructed based on the GCA-7100A Toshiba Gamma Camera at the Royal Surrey County Hospital, Guildford, Surrey, UK. The characteristics are analyzed based on the spatial resolution of the images detected by the Sodium Iodide (NaI) detector. The result is recorded in a list-mode file referred to as a PTRAC file within MCNP5. All pertinent nuclear reaction mechanisms, such as Compton and Rayleigh scattering and photoelectric absorption are undertaken by MCNP5 for all materials encountered by each photon. The experiments were conducted on Tl-201, Co-57, Tc-99 m and Cr-51 radio nuclides. The comparison of full width half maximum value of each datasets obtained from experimental work, simulation and literature are also reported in this paper. The relationship of the simulated data is in agreement with the experimental results and data obtained in the literature. A careful inspection at each of the data points of the spatial resolution of Tc-99 m shows a slight discrepancy between these sets. However, the difference is very insignificant, i.e. less than 3 mm only, which corresponds to a size of less than 1 pixel only (of the segmented detector)00.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of cardiac quiescence from retrospective cardiac computed tomography using a correlation-based phase-to-phase deviation measure

Purpose: Accurate knowledge of cardiac quiescence is crucial to the performance of many cardiac imaging modalities, including computed tomography coronary angiography (CTCA). To accurately quantify quiescence, a method for detecting the quiescent periods of the heart from retrospective cardiac computed tomography (CT) using a correlation-based, phase-to-phase deviation measure was developed. Methods: Retrospective cardiac CT data were obtained from 20 patients (11 male, 9 female, 33–74 yr) and the left main, left anterior descending, left circumflex, right coronary artery (RCA), and interventricular septum (IVS) were segmented for each phase using a semiautomated technique. Cardiac motion of individual coronary vessels as well as the IVS was calculated using phase-to-phase deviation. As an easily identifiable feature, the IVS was analyzed to assess how well it predicts vessel quiescence. Finally, the diagnostic quality of the reconstructed volumes from the quiescent phases determined using the deviation measure from the vessels in aggregate and the IVS was compared to that from quiescent phases calculated by the CT scanner. Three board-certified radiologists, fellowship-trained in cardiothoracic imaging, graded the diagnostic quality of the reconstructions using a Likert response format: 1 = excellent, 2 = good, 3 = adequate, 4 = nondiagnostic. Results: Systolic and diastolic quiescent periods were identified for each subject from the vessel motion calculated using the phase-to-phase deviation measure. The motion of the IVS was found to be similar to the aggregate vessel (AGG) motion. The diagnostic quality of the coronary vessels for the quiescent phases calculated from the aggregate vessel (P{sub AGG}) and IVS (P{sub IV} {sub S}) deviation signal using the proposed methods was comparable to the quiescent phases calculated by the CT scanner (P{sub CT}). The one exception was the RCA, which improved for P{sub AGG} for 18 of the 20 subjects when compared to P{sub CT} (P{sub CT} = 2.48; P{sub AGG} = 2.07, p = 0.001). Conclusions: A method for quantifying the motion of specific coronary vessels using a correlation-based, phase-to-phase deviation measure was developed and tested on 20 patients receiving cardiac CT exams. The IVS was found to be a suitable predictor of vessel quiescence. The diagnostic quality of the quiescent phases detected by the proposed methods was comparable to those calculated by the CT scanner. The ability to quantify coronary vessel quiescence from the motion of the IVS can be used to develop new CTCA gating techniques and quantify the resulting potential improvement in CTCA image quality.

60 APPLIED LIFE SCIENCES↗

Local variability in the orbit of Saturn's F ring

We present an analysis of the orbit of Saturn's F ring using images recorded by the Imaging Science Subsystem of the Cassini spacecraft. A total of 9805 observations have been made from 10 image sequences obtained between 2006 November 23 and 2009 July 28. Each sequence of up to 240 images spans a single orbit of the F ring, allowing 10 independent high-precision estimates of the ring orbit to be made over this ∼3 year period. The ring has been modeled as an inclined uniformly precessing ellipse. The results show a variability in the orbital elements with, for example, the semi-major axis scattered between 140211.2 ± 0.1 km and 140232.9 ± 0.4 km and the fitted periapses locked to the value obtained from a combined fit using the entire three-year span of observations. We show that the observed scatter between the individual estimates of the ring orbit reflect the differing past histories of the particular segments of ring being fitted and that the values are scattered within the limits expected from a single gravitational encounter with the nearby moon, Prometheus. In the combined fit, the scatter averages out to reveal a small systematic bias with respect to the results of Bosh et al. and Albers et al. We believe this is a consequence of the proximity of Prometheus to the ring in the image sequences chosen for this analysis. Finally, we note a close empirical commensurability between the apsidal precession rate, ϖ-dot , of the F ring and the synodic period between Prometheus and the F ring, such that n {sub Prom} – n {sub Fring} ≈ 2 ϖ-dot {sub Fring}, where n {sub Prom} and n {sub Fring} are the mean motions, and discuss its implications.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of the Lactate-to-N-Acetyl-aspartate Ratio Defined With Magnetic Resonance Spectroscopic Imaging Before Radiation Therapy as a New Predictive Marker of the Site of Relapse in Patients With Glioblastoma Multiforme

Purpose: Because lactate accumulation is considered a surrogate for hypoxia and tumor radiation resistance, we studied the spatial distribution of the lactate-to-N-acetyl-aspartate ratio (LNR) before radiation therapy (RT) with 3D proton magnetic resonance spectroscopic imaging (3D-{sup 1}H-MRSI) and assessed its impact on local tumor control in glioblastoma (GBM). Methods and Materials: Fourteen patients with newly diagnosed GBM included in a phase 2 chemoradiation therapy trial constituted our database. Magnetic resonance imaging (MRI) and MRSI data before RT were evaluated and correlated to MRI data at relapse. The optimal threshold for tumor-associated LNR was determined with receiver-operating-characteristic (ROC) curve analysis of the pre-RT LNR values and MRI characteristics of the tumor. This threshold was used to segment pre-RT normalized LNR maps. Two spatial analyses were performed: (1) a pre-RT volumetric comparison of abnormal LNR areas with regions of MRI-defined lesions and a choline (Cho)-to- N-acetyl-aspartate (NAA) ratio ≥2 (CNR2); and (2) a voxel-by-voxel spatial analysis of 4,186,185 voxels with the intention of evaluating whether pre-RT abnormal LNR areas were predictive of the site of local recurrence. Results: A LNR of ≥0.4 (LNR-0.4) discriminated between tumor-associated and normal LNR values with 88.8% sensitivity and 97.6% specificity. LNR-0.4 voxels were spatially different from those of MRI-defined lesions, representing 44% of contrast enhancement, 64% of central necrosis, and 26% of fluid-attenuated inversion recovery (FLAIR) abnormality volumes before RT. They extended beyond the overlap with CNR2 for most patients (median: 20 cm{sup 3}; range: 6-49 cm{sup 3}). LNR-0.4 voxels were significantly predictive of local recurrence, regarded as contrast enhancement at relapse: 71% of voxels with a LNR-0.4 before RT were contrast enhanced at relapse versus 10% of voxels with a normal LNR (P<.01). Conclusions: Pre-RT LNR-0.4 in GBM indicates tumor areas that are likely to relapse. Further investigations are needed to confirm lactate imaging as a tool to define additional biological target volumes for dose painting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Simple IMRT Delivery Techniques for Non-Small Cell Lung Cancer Patients with Respiratory Motion Using 4DCT

Techniques for generating simplified IMRT treatment plans for treating non-small cell lung cancer (NSCLC) patients with respiratory motion were investigated. To estimate and account for respiratory motion, 4-dimensional computed tomography (4DCT) datasets from 5 patients were used to design 5-field 6-MV ungated step-and-shoot intensity modulated radiotherapy (IMRT) plans delivering a dose of 66 Gy to the planning target volume (PTV). For each patient, 2 plans were generated using the mean intensity and the maximum intensity of 10 CT datasets from different breathing phases. The plans also utilized different margins around the clinical target volume/internal target volume (CTV/ITV) to account for tumor motion. To reduce the treatment time and ensure accurate dose delivery to moving targets, the number of intensity levels was minimized while maintaining dose coverage to PTV and minimizing dose to organs at risk (OARs). Dose-volume histograms (DVHs), dosimetric metrics, and outcome probabilities were evaluated for all plans. Plans using the averaged CT image dataset were inferior, requiring larger margins around the PTV, with a maximum of 1.5 cm, to ensure coverage of the tumor, and therefore increased the dose to OARs located in proximity of the tumor. The plans based on superimposed CT image datasets achieved full coverage of the tumor, while allowing tight margins around the PTV and minimizing the dose to OARs. A small number of intensity-levels (3 to 5), resulting in IMRT plans with a total of 13 to 30 segments, were sufficient for homogeneous PTV coverage, without affecting the sparing of OARs. In conclusion, a technique involving treatment planning with the superimposed CT scans of all respiratory phases, and the application of IMRT with only a small number of segments was feasible despite significant tumor motion; however, greater patient numbers are needed to support the statistical significance of the results presented in this work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ion conduction and relaxation in PEO-LiTFSI-Al{sub 2}O{sub 3} polymer nanocomposite electrolytes

Ion conduction and relaxation in PEO-LiTFSI-Al{sub 2}O{sub 3} polymer nanocomposite electrolytes have been studied for different concentrations of Al{sub 2}O{sub 3} nanoparticles. X-ray diffraction and differential scanning calorimetric studies show that the maximum amorphous phase of PEO is observed for PEO-LiTFSI embedded with 5 wt. % Al{sub 2}O{sub 3}. The maximum ionic conductivity ∼3.3 × 10{sup −4} S cm{sup −1} has been obtained for this composition. The transmission electron microscopic image shows a distribution of Al{sub 2}O{sub 3} nanoparticles in all compositions with size of <50 nm. The temperature dependence of the ionic conductivity follows Vogel-Tamman-Fulcher nature, indicating a strong coupling between ionic and polymer chain segmental motions. The scaling of the ac conductivity implies that relaxation dynamics follows a common mechanism for different temperatures and Al{sub 2}O{sub 3} concentrations. The imaginary modulus spectra are asymmetric and skewed toward the high frequency sides of the maxima and analyzed using Havriliak-Negami formalism. The temperature dependence of the relaxation time obtained from modulus spectra also exhibits Vogel-Tamman-Fulcher nature. The values of the stretched exponent obtained from Kohlrausch-Williams-Watts fit to the modulus data are fairly low, suggesting highly non-exponential relaxation for all concentrations of Al{sub 2}O{sub 3} in these electrolytes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydraulic Conductivity Measurements, Utqiagvik (Barrow), Alaska, 2014

Six individual ice cores were collected from the Barrow Environmental Observatory in Barrow, Alaska, in May of 2013 as part of the Next Generation Ecosystem Experiment (NGEE). Each core was drilled at a different location to varying depths. After drilling, the cores were stored in coolers packed with dry ice and flown to Lawrence Berkeley National Laboratory (LBNL) in Berkeley, CA. 3-dimensional images of the cores were constructed using medical X-ray computed tomography (CT) scanner at 120kV. Hydraulic conductivity samples were extracted from these cores at LBNL Richmond Field Station in Richmond, CA, in February 2014 by cutting 5 to 8 inch segments using a chop saw. Samples were packed individually and stored at -20C freezing temperatures to minimize any changes in structure or loss of ice content prior to analysis. Hydraulic conductivity was determined through falling head tests using a permeameter [ELE International, Model #: K-770B] (Appendix A). Samples were placed in a latex membrane via a membrane stretcher while frozen. Use of a membrane stretcher made the membranes easier to secure and minimized contact with the sample. A clear polycarbonate sleeve, fabricated with a stainless steel ring at the bottom to keep the sleeve from floating, was placed around the sample inside the permeameter to minimize deformation during analysis. The permeameter was filled with water and 1.0 PSI of air was applied for confining pressure during sample defrost. Outflow valves were left open to allow for incremental thawing and samples were left to thaw for approximately 12 hours. After approximately 12 hours of thaw, initial falling head tests were performed. When the flow was significantly too fast or too slow, the analysis was stopped and the burette size was adjusted accordingly (i.e. a larger diameter burette was used for flows that were faster than desired or a smaller diameter burette was used for flows that were slower than desired). Two to four measurements were collected on each sample and collection stopped when the applied head load exceeded 25% change from the original load. Analyses were performed between 2 to 3 times for each sample. The final hydraulic conductivity calculations were computed using methodology of Das et al., 1985.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a 15-year research effort (2012-2027) to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

The utility of {sup 82}Rb PET for myocardial viability assessment: Comparison with perfusion-metabolism {sup 82}Rb-{sup 18}F-FDG PET

Background: {sup 82}Rb kinetics may distinguish scar from viable but dysfunctional (hibernating) myocardium. We sought to define the relationship between {sup 82}Rb kinetics and myocardial viability compared with conventional {sup 82}Rb and {sup 18}F-fluorodeoxyglucose (FDG) perfusion-metabolism PET imaging. Methods: Consecutive patients (N = 120) referred for evaluation of myocardial viability prior to revascularization and normal volunteers (N = 37) were reviewed. Dynamic {sup 82}Rb 3D PET data were acquired at rest. {sup 18}F-FDG 3D PET data were acquired after metabolic preparation using a standardized hyperinsulinemic-euglycemic clamp. {sup 82}Rb kinetic parameters K{sub 1}, k{sub 2}, and partition coefficient (KP) were estimated by compartmental modeling Results: Segmental {sup 82}Rb k{sub 2} and KP differed significantly between scarred and hibernating segments identified by Rb-FDG perfusion-metabolism (k{sub 2}, 0.42 ± 0.25 vs. 0.22 ± 0.09 min{sup −1}; P < .0001; KP, 1.33 ± 0.62 vs. 2.25 ± 0.98 ml/g; P < .0001). As compared to Rb-FDG analysis, segmental Rb KP had a c-index, sensitivity and specificity of 0.809, 76% and 84%, respectively, for distinguishing hibernating and scarred segments. Segmental k{sub 2} performed similarly, but with lower specificity (75%, P < .001) Conclusions: In this pilot study, {sup 82}Rb kinetic parameters k{sub 2} and KP, which are readily estimated using a compartmental model commonly used for myocardial blood flow, reliably differentiated hibernating myocardium and scar. Further study is necessary to evaluate their clinical utility for predicting benefit after revascularization. [French] French Abstract: Contexte: La cinétique du {sup 82}Rb pourrait être utilisée pour distinguer la fibrose myocardique des zones viables mais dysfonctionnelles (en hibernation). Dans cette étude, nous avons cherché à définir la relation entre la cinétique du {sup 82}Rb et la viabilité myocardique en comparant les images de perfusion et métabolisme myocardique utilisant le {sup 82}Rb et le {sup 18}F-fluorodésoxyglucose (FDG) Méthodes: les données obtenues chez 120 patients consécutifs (N = 120) référés pour évaluation de la viabilité du myocarde avant revascularisation et 37 volontaires considérés normaux (N = 37) ont été étudieés. Les données TEP 3D dynamiques {sup 82}Rb ont été acquises au repos. Les données TEP 3D au {sup 18}F-FDG ont été acquises après préparation métabolique utilisant une pince hyperinsulémique-euglycémique normalisée. Les paramètres k1, k2 et le coefficient de partage (KP) de la cinétique du {sup 82}R bont été évalues par modélisation compartimentale. Résultats: les paramètres k2 et KP de distribution du {sup 82}Rb se sont révélés significativement différent entre les zones tissulaires cicatricielles fibreuses et celles en hibernation identifiées par étude métabolique au FDG (k2, 0,42 ± 0,25 vs. 0,22 ± 0,09 min{sup −1}; P < 0,0001; KP, 1,33 ± 0,62 vs. 2,25 ± 0,98 ml/g; P < 0,0001). Par rapport aux données FDG, le paramètre KP du rubidium a révélé un indice de concordance de 0,809 et une sensibilité et spécificité de 76% et 84%, pour la distinction des segments en hibernation et cicatrisés. Les résultats du paramètre k2 se sont révélés similaires, mais avec une spécificité plus faible calculée à 75% (P < 0,001). Conclusions: Dans cette étude pilote, les paramètres cinétiques k2 et KP de perfusion myocardique au {sup 82}Rb, qui sont facilement estimés à l’aide d’un modèle compartimental couramment utilisé pour flux sanguin myocardique, ont permis de différencier de manière fiable le myocarde cicatricielle des zones myocardiques hibernantes. Une étude plus approfondie est souhaitable pour valider leur utilité clinique en revacularisation. [Spanish] Spanish Abstract: Antecedentes: La cinética con {sup 82}Rb puede distinguir las cicatrices miocárdicas del tejido viable pero disfuncional (hibernante). Buscamos definir la relación entre la cinética del {sup 82}Rb y la viabilidad miocárdica comparada con las imágenes convencionales de PET con {sup 82}Rb y {sup 18}F-flurodeoxyglucosa (FDG). Métodos: se evaluaron a Pacientes Consecutivos (N = 120) referidos para evaluación de viabilidad miocárdica previos a revascularización y voluntarios normales (N = 37). Los datos de PET 3D dinámico con {sup 82}Rb fueron adquiridos en reposo. Los datos de {sup 18}F-FDG 3D PET fueron adquiridos posterior a la preparación metabólica usando un clamp hiperinsulínico-euglucémico. Los patrones cinéticos K1, k2 y el coeficiente de partición (KP) fueron estimados por el modelo compartimental. Resultados: el k2 y KP del {sup 82}Rb permitueron distinguier el tejido cicatricial de los segmentos hibernados identificados por la vía perfusión metabolismo de Rb-FDG (k{sub 2}, 0.42 ± 0.25 vs. 0.22 ± 0.09 min-1; P < .0001; KP, 1.33 ± 0.62 vs. 2.25 ± 0.98 ml/g; P < .0001). En comparación con el análisis de Rb-FDG, el KP segmentario del Rb tuvo un índice-c, sensbilidad y especificidad de 0.809 76 y 84%, respectivamente, para distinguir segmentos hibernantes y cicatriciales. k2 Segmentario tuvo un desempeño similar pero con una menor especificidad (75%, P < .001). Conclusiones: En este estudio piloto, los parámetros cinéticos k2 y KP del {sup 82}Rb, los cuales son estimados usando un modelo compartimental usado comúnmente para flujo sanguíneo miocárdico, diferenciaron el miocardio hibernante del cicatricial. Se necesita estudiar más a fondo para evaluar la utilidad clínica para la predicción del beneficio posterior a la revascularización [Chinese] Chinese Abstract: 背景: 铷-82({sup 82}Rb)药代动力学可能区分梗死与功能受损但存活的心肌(冬眠心肌)。我们将探讨{sup 82}Rb药代动力学与存活心肌的关系,并与常规的{sup 82}Rb和{sup 18}F-氟脱氧葡萄糖(FDG)灌注-代谢PET显像进行比较。 方法: 连续纳入120名血运重建前评估存活心肌的患者和37名正常志愿者。获得静息{sup 82}Rb 3D-PET动态采集数据;采用标准化的高胰岛素 - 正葡萄糖钳夹试验得到{sup 18}F-FDG 3D PET代谢显像数据; 通过房室模型计算{sup 82}Rb动力学参数k{sub 1},k{sub 2}和分配系数(KP)。 结果: 以Rb-FDG灌注代谢显像鉴定疤痕心肌组和冬眠心肌组,两组的{sup 82}Rb节段性 k{sub 2}值和KP值有明显差异(k{sub 2}, 0.42 ± 0.25 vs 0.22 ± 0.09 min{sup −1}; P < .0001; KP, 1.33 ± 0.62 vs 2.25 ± 0.98 ml/g; P < .0001)。以Rb-FDG灌注代谢显像为诊断标准,{sup 82}Rb节段性 KP对疤痕和冬眠心肌鉴别效能的c指数,敏感性和特异性分别是0.809, 76%和84%。节段性k{sub 2}的鉴别效能与KP相似,但特异性较低(75%,P < .001)。 结论: 在本试验性研究中,通过常规用于{sup 82}Rb心肌血流量测定的房室模型计算出的{sup 82}Rb动力学参数k{sub 2}和KP,可以有效的区分冬眠心肌和瘢痕心肌。 但需要进一步的研究来评估其对预测血运重建是否获益的临床价值。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computerized comprehensive data analysis of Lung Imaging Database Consortium (LIDC)

Purpose: Lung Image Database Consortium (LIDC) is the largest public CT image database of lung nodules. In this study, the authors present a comprehensive and the most updated analysis of this dynamically growing database under the help of a computerized tool, aiming to assist researchers to optimally use this database for lung cancer related investigations. Methods: The authors developed a computer scheme to automatically match the nodule outlines marked manually by radiologists on CT images. A large variety of characteristics regarding the annotated nodules in the database including volume, spiculation level, elongation, interobserver variability, as well as the intersection of delineated nodule voxels and overlapping ratio between the same nodules marked by different radiologists are automatically calculated and summarized. The scheme was applied to analyze all 157 examinations with complete annotation data currently available in LIDC dataset. Results: The scheme summarizes the statistical distributions of the abovementioned geometric and diagnosis features. Among the 391 nodules, (1) 365 (93.35%) have principal axis length {<=}20 mm; (2) 120, 75, 76, and 120 were marked by one, two, three, and four radiologists, respectively; and (3) 122 (32.48%) have the maximum volume overlapping ratios {>=}80% for the delineations of two radiologists, while 198 (50.64%) have the maximum volume overlapping ratios <60%. The results also showed that 72.89% of the nodules were assessed with malignancy score between 2 and 4, and only 7.93% of these nodules were considered as severely malignant (malignancy {>=}4). Conclusions: This study demonstrates that LIDC contains examinations covering a diverse distribution of nodule characteristics and it can be a useful resource to assess the performance of the nodule detection and/or segmentation schemes.

60 APPLIED LIFE SCIENCES↗

A practical global distortion correction method for an image intensifier based x-ray fluoroscopy system

X-ray images acquired on systems with image intensifiers (II) exhibit characteristic distortion which is due to both external and internal factors. The distortion is dependent on the orientation of the II, a fact particularly relevant to II's mounted on C arms which have several degrees of freedom of motion. Previous descriptions of distortion correction strategies have relied on a dense sampling of the C-arm orientation space, and as such have been limited mostly to a single arc of the primary angle, {alpha}. We present a new method which smooths the trajectories of the segmented vertices of the grid phantom as a function of {alpha} prior to solving the two-dimensional warping problem. It also shows that the same residual errors of distortion correction could be achieved without fitting the trajectories of the grid vertices, but instead applying the previously described global method of distortion correction, followed by directly smoothing the values of the polynomial coefficients as functions of the C-arm orientation parameters. When this technique was applied to a series of test images at arbitrary {alpha}, the root-mean-square (RMS) residual error was 0.22 pixels. The new method was extended to three degrees of freedom of the C-arm motion: the primary angle, {alpha}; the secondary angle, {beta}; and the source-to-intensifier distance, {lambda}. Only 75 images were used to characterize the distortion for the following ranges: {alpha}, {+-}45 deg. ({delta}{alpha}=22.5 deg.); {beta}, {+-}36 deg. ({delta}{beta}=18 deg.); {lambda}, 98-118 cm ({delta}{lambda}=10 cm). When evaluated on a series of test images acquired at arbitrary ({alpha},{beta},{lambda}), the RMS residual error was 0.33 pixels. This method is targeted at applications such as guidance of catheter-based interventions and treatment planning for brachytherapy, which require distortion-corrected images over a large range of C-arm orientations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Main Bile Duct Stricture Occurring After Transcatheter Arterial Chemoembolization for Hepatocellular Carcinoma

The purpose of this study was to evaluate the clinical course of main bile duct stricture at the hepatic hilum after transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC). Among 446 consecutive patients with HCC treated by TACE, main bile duct stricture developed in 18 (4.0%). All imaging and laboratory data, treatment course, and outcomes were retrospectively analyzed. All patients had 1 to 2 tumors measuring 10 to 100 mm in diameter (mean {+-} SD 24.5 {+-} 5.4 mm) near the hepatic hilum fed by the caudate arterial branch (A1) and/or medial segmental artery (A4) of the liver. During the TACE procedure that caused bile duct injury, A1 was embolized in 8, A4 was embolized in 5, and both were embolized in 5 patients. Nine patients (50.0%) had a history of TACE in either A1 or A4. Iodized oil accumulation in the bile duct wall was seen in all patients on computed tomography obtained 1 week later. Bile duct dilatation caused by main bile duct stricture developed in both lobes (n = 9), in the right lobe (n = 3), in the left lobe (n = 4), in segment (S) 2 (n = 1), and in S3 (n = 1). Serum levels of alkaline phosphatase and {gamma}-glutamyltranspeptidase increased in 13 patients. Biloma requiring drainage developed in 2 patients; jaundice developed in 4 patients; and metallic stents were placed in 3 patients. Complications after additional TACE sessions, including biloma (n = 3) and/or jaundice (n = 5), occurred in 7 patients and were treated by additional intervention, including metallic stent placement in 2 patients. After initial TACE of A1 and/or A4, 8 patients (44.4%), including 5 with uncontrollable jaundice or cholangitis, died at 37.9 {+-} 34.9 months after TACE, and 10 (55.6%) have survived for 38.4 {+-} 37.9 months. Selective TACE of A1 and/or A4 carries a risk of main bile duct stricture at the hepatic hilum. Biloma and jaundice are serious complications associated with bile duct strictures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interactive image quantification tools in nuclear material forensics

Morphological and microstructural features visible in microscopy images of nuclear materials can give information about the processing history of a nuclear material. Extraction of these attributes currently requires a subject matter expert in both microscopy and nuclear material production processes, and is a time consuming, and at least partially manual task, often involving multiple software applications. One of the primary goals of computer vision is to find ways to extract and encode domain knowledge associated with imagery so that parts of this process can be automated. In this paper we describe a user-in-the-loop approach to the problem which attempts to both improve the efficiency of domain experts during image quantification as well as capture their domain knowledge over time. This is accomplished through a sophisticated user-monitoring system that accumulates user-computer interactions as users exploit their imagery. We provide a detailed discussion of the interactive feature extraction and segmentation tools we have developed and describe our initial results in exploiting the recorded user-computer interactions to improve user productivity over time.

36 MATERIALS SCIENCE↗

Cord Dose Specification and Validation for Stereotactic Body Radiosurgery of Spine

Effective dose to a portion of the spinal cord in treatment segment, rather than the maximum point dose in the cord surface, was set as the dose limit in stereotactic-body radiosurgery (SBRS) of spine. Such a cord dose specification is sensitive to the volume size and position errors. Thus, we used stereotactic image guidance to minimize phantom positioning errors and compared the results of a 0.6-cm{sup 3} Farmer ionization chamber and a 0.01-cm{sup 3} compact ionization chamber to determine the detector size effect on 9 SBRS cases. The experimental errors ranging from 2% to 7% were estimated by the deviation of the mean dose in plans to the chamber with spatial displacements of 0.5 mm. The mean and measured doses for the large chamber to individual cases were significantly ({approx}17%) higher than the doses with the compact chamber placed at the same point. Our experimental results shown that the mean doses to the volume of interest could represent the measured cord doses. For the 9 patients, the mean doses to 10% of the cord were about 10 Gy, while the maximum cord doses varied from 11.6 to 17.6 Gy. The mean dose, possibly correlated with the cord complication, provided us an alternative and reliable cord dose specification in SBRS of spine.

61 RADIATION PROTECTION AND DOSIMETRY↗