Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Human Errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Assessing probe-specific dye and slide biases in two-color microarray data

Background: A primary reason for using two-color microarrays is that the use of two samples labeled with different dyes on the same slide, that bind to probes on the same spot, is supposed to adjust for many factors that introduce noise and errors into the analysis. Most users assume that any differences between the dyes can be adjusted out by standard methods of normalization, so that measures such as log ratios on the same slide are reliable measures of comparative expression. However, even after the normalization, there are still probe specific dye and slide variation among the data. We define a method to quantify the amount of the dye-by-probe and slide-by-probe interaction. This serves as a diagnostic, both visual and numeric, of the existence of probe-specific dye bias. We show how this improved the performance of two-color array analysis for arrays for genomic analysis of biological samples ranging from rice to human tissue. Results: We develop a procedure for quantifying the extent of probe-specific dye and slide bias in two-color microarrays. The primary output is a graphical diagnostic of the extent of the bias which called ECDF (Empirical Cumulative Distribution Function), though numerical results are also obtained. Conclusion: We show that the dye and slide biases were high for human and rice genomic arrays in two gene expression facilities, even after the standard intensity-based normalization, and describe how this diagnostic allowed the problems causing the probe-specific bias to be addressed, and resulted in important improvements in performance. The R package LMGene which contains the method described in this paper has been available to download from Bioconductor.

59 BASIC BIOLOGICAL SCIENCES↗

James Webb Space Telescope: The First Light Machine

NASA James Webb Space Telescope (JWST) will search for the first luminous objects of the Universe to help answer fundamental questions about how the Universe came to look like it does today. At 6.5 meters in diameter, JWST will be the world's largest space telescope. Its architecture, e.g. aperture, wavelength range and operating temperature, is driven by JWST's science objectives. Introduction: Scheduled to start its 5 year mission after 2018, JWST will study the origin and evolution of galaxies, stars and planetary systems. Its science mission is to: Identify the first bright objects that formed in the early Universe, and follow the ionization history. Determine how galaxies form. Determine how galaxies and dark matter, including gas, stars, metals, overall morphology and active nuclei evolved to the present day. Observe the birth and early development of stars and the formation of planets. And, study the physical and chemical properties of solar systems for the building blocks of Life. Principle: To accomplish the JWST science objectives requires a larger aperture infrared cryogenic space telescope. A large aperture is required because the objects are very faint. The infrared spectral range is required because the objects are so far away that their ultraviolet and visible wavelength spectral lines are red-shifted into the infrared. Because the telescope is infrared, it needs to be cryogenic. And, because of the telescope is infrared, it must operate above the Earth's atmosphere, i.e. in space. JWST is probably the single most complicated mission that humanity has attempted. It is certainly the most difficult optical fabrication and testing challenge of our generation. The JWST 6.5 m diameter primary mirror is nearly a parabola with a conic constant of -0.9967 and radius of curvature at 30K of 15.880 m. The primary mirror is divided into 18 segments with 3 different prescriptions; each with its own off-axis distance and aspheric departure. The radius of curvature for all 18 segments must match to +/- 0.150 mm at 30K. JWST is diffraction limited at 2 micrometers which translates into a transmitted wavefront specification of 156 nm rms. Of that amount, 50 nm rms is allocated to the primary mirror. Each segment is allocated 22 nm rms surface error. At the start of the JWST program, the capability to make such a mirror did not exist. In 1996, NASA began a systematic and comprehensive mirror technology development effort which resulted in JWST. This program resulted in a qualified mirror fabrication process being approved in 2006. Today, all JWST primary mirror segments meet their requirements and are on schedule for a 2018 launch. The next step is system level assembly, integration and test. Ambient tests will be conducted at Goddard Space Flight Center and cryogenic system level testing will be performed in Chamber A at the Johnson Space Center.

Stahl, H. Philip↗

VirSorter2: a multi-classifier, expert-guided approach to detect diverse DNA and RNA viruses

Abstract Background Viruses are a significant player in many biosphere and human ecosystems, but most signals remain “hidden” in metagenomic/metatranscriptomic sequence datasets due to the lack of universal gene markers, database representatives, and insufficiently advanced identification tools. Results Here, we introduce VirSorter2, a DNA and RNA virus identification tool that leverages genome-informed database advances across a collection of customized automatic classifiers to improve the accuracy and range of virus sequence detection. When benchmarked against genomes from both isolated and uncultivated viruses, VirSorter2 uniquely performed consistently with high accuracy (F1-score > 0.8) across viral diversity, while all other tools under-detected viruses outside of the group most represented in reference databases (i.e., those in the order Caudovirales ). Among the tools evaluated, VirSorter2 was also uniquely able to minimize errors associated with atypical cellular sequences including eukaryotic genomes and plasmids. Finally, as the virosphere exploration unravels novel viral sequences, VirSorter2’s modular design makes it inherently able to expand to new types of viruses via the design of new classifiers to maintain maximal sensitivity and specificity. Conclusion With multi-classifier and modular design, VirSorter2 demonstrates higher overall accuracy across major viral groups and will advance our knowledge of virus evolution, diversity, and virus-microbe interaction in various ecosystems. Source code of VirSorter2 is freely available ( https://bitbucket.org/MAVERICLab/virsorter2 ), and VirSorter2 is also available both on bioconda and as an iVirus app on CyVerse ( https://de.cyverse.org/de ).

59 BASIC BIOLOGICAL SCIENCES↗

Prototype Laboratory Concept

The prototype laboratory concept was developed to simplify the laboratory design process, and should be considered for use as a new laboratory design methodology. Many developing countries lack adequate public and animal health laboratories and typically do not have the economic means and the design and construction expertise to build a laboratory on their own. These countries rely on international sponsors to provide the funds necessary to design and construct a laboratory. However, these international sponsors are often located far away, making travel back and forth difficult, which leads to an increase in overall costs and delays for the project. The prototype laboratory concept and design methodology were developed to streamline the design process, saving time and money, while also minimizing the number of errors that typically arise using a traditional design process by providing well considered design decisions in advance of the project. By solving numerous detailed design issues early, this methodology will allow the time, attention and energies of the design team to be focused on addressing the specific needs of the end users, the unique design challenges related to a given site and scientific program, and the biosafety and biosecurity risks associated with the scientific activities planned to be conducted in the facility. While the concept could be expanded to cover other types of laboratories to date, it has primarily focused on supporting the implementation of good laboratory design best practices for infectious disease diagnostic and research laboratories for both the human and animal health sectors. This report presents the laboratory design concept and details associated with the modular layouts. It builds on the work previously provided in the interim prototype laboratory concept report delivered to the Cooperative Biological Engagement Program (CBEP) at the Defense Threat Reduction Agency (DTRA) in 2014. This report includes a number of revised and additional module layouts, more detailed information regarding laboratory finishes and equipment, engineering service information, electrical and lighting layouts, plumbing service information and two mechanical service options for each prototype module. Additionally, this report also includes a description of a cost estimating tool that will accompany this report and allow funding agencies to generate an approximate cost for the construction of a laboratory that utilizes the prototype laboratory concept modules. This report is intended to serve a complete document and includes all relevant information from the 2014 prototype laboratory concept report.

42 ENGINEERING↗

Combinatorial DNA Damage Pairing Model Based on X-Ray-Induced Foci Predicts the Dose and LET Dependence of Cell Death in Human Breast Cells

In contrast to the classic view of static DNA double-strand breaks (DSBs) being repaired at the site of damage, we hypothesize that DSBs move and merge with each other over large distances (m). As X-ray dose increases, the probability of having DSB clusters increases as does the probability of misrepair and cell death. Experimental work characterizing the X-ray dose dependence of radiation-induced foci (RIF) in nonmalignant human mammary epithelial cells (MCF10A) is used here to validate a DSB clustering model. We then use the principles of the local effect model (LEM) to predict the yield of DSBs at the submicron level. Two mechanisms for DSB clustering, namely random coalescence of DSBs versus active movement of DSBs into repair domains are compared and tested. Simulations that best predicted both RIF dose dependence and cell survival after X-ray irradiation favored the repair domain hypothesis, suggesting the nucleus is divided into an array of regularly spaced repair domains of ~;;1.55 m sides. Applying the same approach to high-linear energy transfer (LET) ion tracks, we are able to predict experimental RIF/m along tracks with an overall relative error of 12percent, for LET ranging between 30 350 keV/m and for three different ions. Finally, cell death was predicted by assuming an exponential dependence on the total number of DSBs and of all possible combinations of paired DSBs within each simulated RIF. Relative biological effectiveness (RBE) predictions for cell survival of MCF10A exposed to high-LET showed an LET dependence that matches previous experimental results for similar cell types. Overall, this work suggests that microdosimetric properties of ion tracks at the submicron level are sufficient to explain both RIF data and survival curves for any LET, similarly to the LEM assumption. Conversely, high-LET death mechanism does not have to infer linear-quadratic dose formalism as done in the LEM. In addition, the size of repair domains derived in our model are based on experimental RIF and are three times larger than the hypothetical LEM voxel used to fit survival curves. Our model is therefore an alternative to previous approaches that provides a testable biological mechanism (i.e., RIF). In addition, we propose that DSB pairing will help develop more accurate alternatives to the linear cancer risk model (LNT) currently used for regulating exposure to very low levels of ionizing radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Surface Navigation Using Optimized Waypoints and Particle Swarm Optimization

The design priority for manned space exploration missions is almost always placed on human safety. Proposed manned surface exploration tasks (lunar, asteroid sample returns, Mars) have the possibility of astronauts traveling several kilometers away from a home base. Deviations from preplanned paths are expected while exploring. In a time-critical emergency situation, there is a need to develop an optimal home base return path. The return path may or may not be similar to the outbound path, and what defines optimal may change with, and even within, each mission. A novel path planning algorithm and prototype program was developed using biologically inspired particle swarm optimization (PSO) that generates an optimal path of traversal while avoiding obstacles. Applications include emergency path planning on lunar, Martian, and/or asteroid surfaces, generating multiple scenarios for outbound missions, Earth-based search and rescue, as well as human manual traversal and/or path integration into robotic control systems. The strategy allows for a changing environment, and can be re-tasked at will and run in real-time situations. Given a random extraterrestrial planetary or small body surface position, the goal was to find the fastest (or shortest) path to an arbitrary position such as a safe zone or geographic objective, subject to possibly varying constraints. The problem requires a workable solution 100% of the time, though it does not require the absolute theoretical optimum. Obstacles should be avoided, but if they cannot be, then the algorithm needs to be smart enough to recognize this and deal with it. With some modifications, it works with non-stationary error topologies as well.

Birge, Brian↗

Spatial coding of eye movements relative to perceived earth and head orientations during static roll tilt

This purpose of this study was to examine the spatial coding of eye movements during static roll tilt (up to +/-45 degrees) relative to perceived earth and head orientations. Binocular videographic recordings obtained in darkness from eight subjects allowed us to quantify the mean deviations in gaze trajectories along both horizontal and vertical coordinates relative to the true earth and head orientations. We found that both variability and curvature of gaze trajectories increased with roll tilt. The trajectories of eye movements made along the perceived earth-horizontal (PEH) were more accurate than movements along the perceived head-horizontal (PHH). The trajectories of both PEH and PHH saccades tended to deviate in the same direction as the head tilt. The deviations in gaze trajectories along the perceived earth-vertical (PEV) and perceived head-vertical (PHV) were both similar to the PHH orientation, except that saccades along the PEV deviated in the opposite direction relative to the head tilt. The magnitude of deviations along the PEV, PHH, and PHV corresponded to perceptual overestimations of roll tilt obtained from verbal reports. Both PEV gaze trajectories and perceptual estimates of tilt orientation were different following clockwise rather than counterclockwise tilt rotation; however, the PEH gaze trajectories were less affected by the direction of tilt rotation. Our results suggest that errors in gaze trajectories along PEV and perceived head orientations increase during roll tilt in a similar way to perceptual errors of tilt orientation. Although PEH and PEV gaze trajectories became nonorthogonal during roll tilt, we conclude that the spatial coding of eye movements during roll tilt is overall more accurate for the perceived earth reference frame than for the perceived head reference frame.

NASA Discipline Neuroscience↗

TH-CD-206-12: Image-Based Motion Estimation for Plaque Visualization in Coronary Computed Tomography Angiography

Purpose: Visualization and quantification of coronary artery calcification and atherosclerotic plaque benefits from coronary artery motion (CAM) artifact elimination. This work applies a rigid linear motion model to a Volume of Interest (VoI) for estimating motion estimation and compensation of image degradation in Coronary Computed Tomography Angiography (CCTA). Methods: In both simulation and testbench experiments, translational CAM was generated by displacement of the imaging object (i.e. simulated coronary artery and explanted human heart) by ∼8 mm, approximating the motion of a main coronary branch. Rotation was assumed to be negligible. A motion degraded region containing a calcification was selected as the VoI. Local residual motion was assumed to be rigid and linear over the acquisition window, simulating motion observed during diastasis. The (negative) magnitude of the image gradient of the reconstructed VoI was chosen as the motion estimation objective and was minimized with Covariance Matrix Adaptation Evolution Strategy (CMAES). Results: Reconstruction incorporated the estimated CAM yielded signification recovery of fine calcification structures as well as reduced motion artifacts within the selected local region. The compensated reconstruction was further evaluated using two image similarity metrics, the structural similarity index (SSIM) and Root Mean Square Error (RMSE). At the calcification site, the compensated data achieved a 3% increase in SSIM and a 91.2% decrease in RMSE in comparison with the uncompensated reconstruction. Conclusion: Results demonstrate the feasibility of our image-based motion estimation method exploiting a local rigid linear model for CAM compensation. The method shows promising preliminary results for the application of such estimation in CCTA. Further work will involve motion estimation of complex motion corrupted patient data acquired from clinical CT scanner.

60 APPLIED LIFE SCIENCES↗

Infusing Statistical Thinking into the NASA Quesst Community Test Campaign

Statistical thinking permeates many important decisions as NASA plans its Quesst mission, which will culminate in a series of community overflights using the X-59 aircraft to demonstrate low-noise supersonic flight. Month-long longitudinal surveys will be deployed to assess human perception and annoyance to this new acoustic phenomenon. NASA works with a large contractor team to develop systems and methodologies to estimate noise doses, to test and field socio-acoustic surveys, and to study the relationship between the two quantities, dose and response, through appropriate choices of statistical models. This latter dose-response relationship will serve as an important tool as national and international noise regulators debate whether overland supersonic flights could be permitted once again within permissible noise limits. In this presentation we highlight several areas where statistical thinking has come into play, including issues of sampling, classification and data fusion, and analysis of longitudinal survey data that are subject to rare events and the consequences of measurement error. We note several operational constraints that shape the appeal or feasibility of some decisions on statistical approaches, and we identify several important remaining questions to be addressed.

Bayesian model↗

Principled halftoning based on human vision models

When models of human vision adequately measure the relative quality of candidate halftonings of an image, the problem of halftoning the image becomes equivalent to the search problem of finding a halftone that optimizes the quality metric. Because of the vast number of possible halftones, and the complexity of image quality measures, this principled approach has usually been put aside in favor of fast algorithms that seem to perform well. We find that the principled approach can lead to a range of useful halftoning algorithms, as we trade off speed for quality by varying the complexity of the quality measure and the thoroughness of the search. High quality halftones can be obtained reasonably quickly, for example, by using as a measure the vector length of the error image filtered by a contrast sensitivity function, and, as the search procedure, the sequential adjustment of individual pixels to improve the quality measure. If computational resources permit, simulated annealing can find nearly optimal solutions.

Mulligan, Jeffrey B.↗

The Role of Presented Objects in Deriving Color Preference Criteria from Psychophysical Studies

Of the many “components” of a color rendering measure, one is perhaps the most important: the set of color samples (spectral reflectance functions) that are employed as a standardized means of evaluating and rating a light source. At the same time, a standardized set of color samples can never apply perfectly to a real space or a real set of observed objects, meaning there will always be some level of mismatch between the predicted and observed color shifts. This mismatch is important for lighting specifiers to consider, but even more critical for experiments that seek to evaluate the relationship between color rendering measures and human perception. This article explores how the color distortions of three possible experimental object sets compare to the color distortions predicted using the color evaluation samples of IES TM-30-15 (TM-30). The experimental object sets include those from Royer and colleagues [2016], a set of produce (10 fruits and vegetables), and the X-rite Color Checker Classic. The differences are traced back to properties of the samples sets, such as the coverage of color space, average chroma level, and specific spectral features. The consequence of the differences, that the visual evaluation is based on color distortions that are substantially different from what is predicted, can lead to inaccurate criteria or models of a given perception, such as preference. To minimize the error in using criteria or models when specifying color rendering attributes for a given application, the criteria or models should be developed using a set of experimental objects that matches the typical objects of the application as closely as possible. Alternatively, if typical objects of an application cannot be reasonably determined, an object set that matches the distortions predicted by TM-30 as close as possible is likely to provide the most meaningful results.

60 APPLIED LIFE SCIENCES↗

Enhanced Oceanic Operations Human-In-The-Loop In-Trail Procedure Validation Simulation Study

The Enhanced Oceanic Operations Human-In-The-Loop In-Trail Procedure (ITP) Validation Simulation Study investigated the viability of an ITP designed to enable oceanic flight level changes that would not otherwise be possible. Twelve commercial airline pilots with current oceanic experience flew a series of simulated scenarios involving either standard or ITP flight level change maneuvers and provided subjective workload ratings, assessments of ITP validity and acceptability, and objective performance measures associated with the appropriate selection, request, and execution of ITP flight level change maneuvers. In the majority of scenarios, subject pilots correctly assessed the traffic situation, selected an appropriate response (i.e., either a standard flight level change request, an ITP request, or no request), and executed their selected flight level change procedure, if any, without error. Workload ratings for ITP maneuvers were acceptable and not substantially higher than for standard flight level change maneuvers, and, for the majority of scenarios and subject pilots, subjective acceptability ratings and comments for ITP were generally high and positive. Qualitatively, the ITP was found to be valid and acceptable. However, the error rates for ITP maneuvers were higher than for standard flight level changes, and these errors may have design implications for both the ITP and the study's prototype traffic display. These errors and their implications are discussed.

Murdoch, Jennifer L.↗

Teal Cycle Ergometer Vibration Isolation and Stabilization System Human-in-the-Loop Ground Evaluation for Long-Duration Spaceflight

Purpose: To counter the deleterious effects of weightlessness on the cardiopulmonary system, astronauts living on the International Space Station exercise on a variety of countermeasure equipment including the Cycle Ergometer Vibration Isolation and Stabilization System (CEVIS). Operational since 2001, the onboard CEVIS will be replaced by a new model, known as Teal CEVIS (TC). As a part of ground evaluation, TC hardware underwent human-in-the-loop (HITL) testing to verify the TC hardware produces workloads that elicit physiologic responses comparable to a laboratory cycle ergometer (LAB). Methods: Seven subjects (5 M/2 F) performed submaximal cycle ergometer testing with indirect calorimetry measures on TC and LAB on separate test days. Testing consisted of graded 30 watt increases in workload until subjects reached 85% of age-predicted max heart rate (HR). Exercise outcomes included rate of oxygen uptake (VO2; liters/min), rate of energy expenditure (REE; kcal/min), and HR (beats/min). Linear mixed models (LMM) were fitted to compare VO2, REE, and HR responses between devices across power outputs with fixed effects for power (P) and device (D) and with random effects for subject. LMM effect coefficients (β), std errors (SE), pseudo-partial R2 of effects (pR2), and model likelihood ratio statistics (χ2, Pr(> chisq); α<.05) are provided. Results: LMM main effects for P and D were observed for VO2 (βp=.0107, SE = .0002, pR2=0.97; βd = -0.075, SE = 0.019, pR2=0.14; χ2(1)= 13.57, p<.001), such that VO2 was higher across stages on TC. Main effects of P and D were observed for REE (βp= .0586, SE = 0.001, pR2= 0.97; βd = -0.33208, SE = 0.099, pR2= 0.056; χ2(1)=10.481, p < .01), such that REE was higher across power outputs on TC. A P x D interaction was observed for HR, along with main effects for P and D (βp x d =-0.048, SE = 0.02, pR2=0.048; βp= 0.42, SE = 0.016, pR2=0.87; χ2(1) = 5.398, p = 0.02), such that higher workloads elicited a greater difference in HR between devices. Conclusions: HITL results show, TC elicits greater physiologic responses across power outputs compared to LAB. However, pR2 for device effects show small differences between devices. Therefore, TC can be expected to provide appropriate physiological stimulus across workloads and be considered a reliable tool to mitigate the effects of weightlessness.

Cycle Ergometer Vibration and Isolation System↗

Free Radical Chemistry of Disinfection Byproducts. 3. Degradation Mechanisms of Chloronitromethane, Bromonitromethane and Dichloronitromethane

Halonitromethanes (HNMs) are byproducts formed through ozonation and chlorine/ chloramine disinfection processes in drinking waters that contain dissolved organic matter and bromide ions. These species occur at low concentration, but have been determined to have high cytotoxicity and mutagenicity and therefore may represent a human health hazard. In this study, we have investigated the chemistry involved in the mineralization of HNMs to non-hazardous inorganic products through the application of advanced oxidation and reduction processes. We have combined measured absolute reaction rate constants for the reactions of chloronitromethane, bromonitromethane and dichloronitromethane with the hydroxyl radical and the hydrated electron with a kinetic computer model in an attempt to elucidate the reaction pathways of these HNMs. The results are compared to measurements of stable products resulting from steady-state 60Co y-irradiations of the same compounds. The model predicted the decomposition of the parent compounds and ingrowth of chloride and bromide ions with excellent accuracy, but the prediction of the total nitrate ion concentration was slightly in error, reflecting the complexity of nitrogen oxide species reactions in irradiated solution.

99 GENERAL AND MISCELLANEOUS↗

A business case for nuclear plant control room modernization - 352

This paper presents a generic business case for implementation of technology that supports Control Room Modernization (CRM) in existing nuclear power plants (NPPs). The business case is based on advanced digital instrumentation and control (I and C), human-system interface (HSI), and work process technologies that allow NPP operators to conduct control room operations with improved human factors and efficiency, and therefore operate with fewer operational events. Labor savings can be harvested in terms of reduced overtime and redistribution of work. Significant savings are also demonstrated as reduced time to bring the plant back on line after completion of outages. The benefits are quantified to a rough order of magnitude, providing directional guidance to NPPs that are interested in developing similar business cases. The technologies employed in CRM include large overview displays, task-based operator displays, computer-based procedures, advanced alarm systems, computerized operator support systems, and wireless networks, among others. The CRM business case is founded on the following categories of cost savings: - Integrated Computer-Based Procedures for Operators; - Reduction in Corrective Action Program Work Due to Operator Error; - Reduction in Outage Critical Path Time; - Operation of Local Control Panels; - Reduction in Control Room Support; - Reduction in Plant Events Resulting in Generation Loss; - Paperless Control Room Processes. In addition to cost savings, these technologies also offer improvements to indirect ways that have impact on key performance indicators of the plant. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Digitizing Today’s Buildings in the Real World: Lessons from Field Demonstrations

Digital twins, created by generating a virtual replica of a building, enable safe evaluation of operational scenarios and applications like fault detection and diagnosis and advanced controls. However, a prerequisite is the creation of a machine-readable digital representation of a building, currently hindered by fragmented information scattered across mechanical drawings, point lists, and natural language sequences. As a result, digital twin development remains labor-intensive, error-prone, and difficult to validate. To address these challenges, two efforts from ASHRAE aim to support the digitalization of buildings. ASHRAE s223 establishes a semantic model of buildings, representing system components, configuration, and data sources. ASHRAE s231 defines a vendor-neutral programming language for expressing their control logic. As the industry evaluates implementing them in their products, understanding the challenges that vendors and implementers may face is crucial. In this paper, we present findings and lessons learned from field demonstrations in five buildings that implemented control applications using ASHRAE s223 and s231. The demonstrations highlight how semantic modeling and formalized control descriptions can significantly reduce software development time, manual point mapping, and hard-coding. Beyond time efficiency, they enable reliable automation by minimizing human interpretation and providing a means for consistency across projects. We describe the processes and best practices for model creation and model usage, from translating heterogeneous building documentation into semantic representations to implementing control logic in real-world systems. Finally, we discuss the challenges that persist, including integration with legacy software environments, gaps in interoperability, and the level of expertise still required to effectively leverage semantic models.

Prakash, Anand Krishnan↗

A New Black Carbon Sensor for Dense Air Quality Monitoring Networks

Low-cost air pollution sensors are emerging and increasingly being deployed in densely distributed wireless networks that provide more spatial resolution than is typical in traditional monitoring of ambient air quality. However, a low-cost option to measure black carbon (BC)—a major component of particulate matter pollution associated with adverse human health risks—is missing. This paper presents a new BC sensor designed to fill this gap, the Aerosol Black Carbon Detector (ABCD), which incorporates a compact weatherproof enclosure, solar-powered rechargeable battery, and cellular communication to enable long-term, remote operation. This paper also demonstrates a data processing methodology that reduces the ABCD’s sensitivity to ambient temperature fluctuations, and therefore improves measurement performance in unconditioned operating environments (e.g., outdoors). A fleet of over 100 ABCDs was operated outdoors in collocation with a commercial BC instrument (Magee Scientific, Model AE33) housed inside a regulatory air quality monitoring station. The measurement performance of the 105 ABCDs is comparable to the AE33. The fleet-average precision and accuracy, expressed in terms of mean absolute percentage error, are 9.2 ± 0.8% (relative to the fleet average data) and 24.6 ± 0.9% (relative to the AE33 data), respectively (fleet-average ± 90% confidence interval).

47 OTHER INSTRUMENTATION↗

The estimation of absorbed dose rates for non-human biota : an extended inter-comparison.

An exercise to compare 10 approaches for the calculation of unweighted whole-body absorbed dose rates was conducted for 74 radionuclides and five of the ICRP's Reference Animals and Plants, or RAPs (duck, frog, flatfish egg, rat and elongated earthworm), selected for this exercise to cover a range of body sizes, dimensions and exposure scenarios. Results were analysed using a non-parametric method requiring no specific hypotheses about the statistical distribution of data. The obtained unweighted absorbed dose rates for internal exposure compare well between the different approaches, with 70% of the results falling within a range of variation of {+-}20%. The variation is greater for external exposure, although 90% of the estimates are within an order of magnitude of one another. There are some discernible patterns where specific models over- or under-predicted. These are explained based on the methodological differences including number of daughter products included in the calculation of dose rate for a parent nuclide; source-target geometry; databases for discrete energy and yield of radionuclides; rounding errors in integration algorithms; and intrinsic differences in calculation methods. For certain radionuclides, these factors combine to generate systematic variations between approaches. Overall, the technique chosen to interpret the data enabled methodological differences in dosimetry calculations to be quantified and compared, allowing the identification of common issues between different approaches and providing greater assurance on the fundamental dose conversion coefficient approaches used in available models for assessing radiological effects to biota.

59 BASIC BIOLOGICAL SCIENCES↗