Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Benefits of Dual Fuel Heat Pump Grid-responsive Control: A Model-based Control Optimization Approach Using Building and Equipment Co-simulation

Conventional dual fuel heat pumps lack the intelligent control mechanisms to efficiently manage the switch between heat pump and furnace, leading to sub-optimal energy usage and, in some cases, increased operating costs. To resolve this gap, this study applies optimized control on hybrid heat pumps. With a focus on equipment control strategies, we compare the performances of five spacing heating equipment, including a conventional heat pump (HP), a conventional furnace, a dual fuel heat pump (DFHP) with conventional control, a dual fuel heat pump with smart control, and a novel seamlessly fuel flexible heat pump (SFFHP). While DFHP runs on either gas or electricity at any given moment, SFFHP concurrently consumes gas and electricity by continuously optimizing the proportion of each. In this research, a co-simulation framework is developed by integrating a building envelope model with a physics-based heat pump simulation model to analyze the benefits of grid-responsive controls of DFHP and SFFHP. The model-based optimal controls adjust the operation of the heat pump and gas furnace based on utility price signals and marginal grid emission to minimize utility cost and CO 2 emissions for multiple climate zones, different utility tariffs, and marginal grid emission scenarios. Case studies in Chicago and Los Angeles demonstrate that SFFHP and DFHP, with model-based optimal control, can deliver significant reductions in peak demand, utility cost, and CO 2 emission. In Chicago, SFFHP and smart controlled DFHP yield up to 64.7% and 61.7% utility cost reduction and up to 15.7% and 8.5% CO 2 emission reduction compared to the gas furnace. In Los Angeles, SFFHP and smart controlled DFHP achieve up to 43.6% and 40.1% utility cost reduction and up to 13.8% and 14.1% CO2 emission reduction compared to conventional heat pumps. In conclusion, by leveraging the fuel flexibility nature of dual fuel heat pumps, the model-based control optimization approach makes dual fuel heat pump an attractive option for demand response programs.

Control↗

Field testing and validation of a low-cost MPC for demand flexibility for grid-interactive K-12 schools

K-12 school buildings account for the highest energy consumption within the public sector. Implementing advanced HVAC controls in grid-interactive K-12 schools could bring substantial economic advantages and grid flexibility. Our previous study demonstrated that a low-cost model predictive control (MPC) solution, which coordinates multiple packaged units, can enable demand flexibility without major hardware upgrades. However, a significant gap remains between academic pilots and market-ready scalable solutions. This paper extends the previous single-site pilot to a multi-site demonstration involving three school campuses (95 total units) through a commercial technology transfer process. Addressing the challenge of verifying performance with sparse field data, we present a new statistical approach using Bayesian methods to estimate the MPC’s effect on peak demand. Unlike traditional methods, this approach robustly quantifies uncertainty in non-normal, limited datasets. The results confirm the solution’s replicability, achieving a 21.6–38.9% reduction in HVAC peak demand (10.8–22.1% at the site-level) with > 98% probability across diverse locations. Finally, we document critical barriers to scaling software-as-a-service (SaaS) solutions–such as API instability and diverse legacy systems–and offer practical strategies to accelerate the commercial adoption of grid-interactive efficient buildings.

Ham, Sang Woo↗

Spatio-temporal impacts of a utility’s efficiency portfolio on the distribution grid

Energy Efficiency has historically focused on delivering savings to offset growth in energy supply. Today’s growing emphasis on decarbonization of the energy supply is driving renewables adoption and increased interest in electrification. As a result, energy efficiency is being assessed not just in its ability to offset load growth, but also for its ability to alleviate location-specific constraints on transmission and distribution infrastructure. This work demonstrates that advanced measurement and verification modeling techniques can be used to estimate the spatio-temporal grid impact of a portfolio of energy efficiency programs. It extends measurement-based methods to an entire Demand Side Management portfolio and uses a single model to predict annual as well as seasonal building energy use with near-zero bias. In addition, new metrics are introduced to assess grid level impacts of energy efficiency. The results show that the efficiency program portfolio delivers savings of over 12% at the territory-wide proxy level, with substation and feeder level savings ranging from 0.4% to 26%, and ~5%-42% respectively. Overall, these savings impacted 1.0%–1.4% of the energy used at these locations in the grid. This work provides a methodology with potential to connect efficiency with distribution planning, carrying implications for non-wires alternatives and targeted delivery of efficiency programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cost-optimized energy storage operation for a grid-connected solar PV system at community and individual scales

This study provides a comparative analysis of grid-connected PV-integrated battery storage at individual and community scales. The paper addresses the challenge of managing energy demand-generation mismatch by using a battery energy storage optimization algorithm, which minimizes operational costs while accounting for battery degradation. Also, this work introduces a broader evaluation basis that includes seasonal variability, grid exchange smoothness, and scalability across different battery capacities. Results show that community-scale storage more effectively dampens grid exchange power fluctuations and reduces system costs, particularly with moderate price differences between electricity buying and selling prices and low battery capacities. The paper also analyzes the impacts of static control versus cost-optimized battery system management. Here, it is shown that the gap in system costs between the cost-optimized and static control scenarios widens as the price difference increases.

25 ENERGY STORAGE↗

Effect of spacer grids on high-burnup fuel fragmentation, relocation, and dispersal

Increasing the fuel burnup limit in light-water reactors to improve fuel cycle economics requires a strong technical foundation. Experimental observations from the Halden and Studsvik programs have revealed severe fuel fragmentation during loss-of-coolant accident (LOCA) conditions, highlighting the need for additional technical evaluation. Consequently, further LOCA test data are needed to complement existing findings and improve the understanding of fuel fragmentation, relocation, and dispersal (FFRD) behavior. Oak Ridge National Laboratory’s Severe Accident Test Station has played a significant role in advancing the understanding of high-burnup fuel fragmentation, relocation, and dispersal phenomena. One remaining gap in the available experimental database is the effect of fuel assembly structural features on cladding deformation behavior during a LOCA, and more specifically, their impact on the fuel’s ability to fragment, relocate, and disperse. Recent analyses using the BISON fuel performance code suggest that cladding deformation near grid spacers will remain below the 3% threshold that has been reported in the NRC Research Information Letter, indicating that the cladding could remain mechanically constrained during the LOCA event. This paper builds upon the BISON analyses to design and conduct a series of out-of-cell tests aimed at further evaluating cladding deformation in and around grid spacers. In addition, these tests were used to assess local cladding temperature conditions and compare them against analytical predictions in order to better replicate expected in-reactor behavior. Finally, an in-cell high-burnup LOCA test was designed and performed to evaluate the effects of a grid spacer, or cladding restraint, on fuel fragmentation, relocation, and dispersal susceptibility. The high-burnup test results differed from those of historical LOCA experiments, with a recorded rupture temperature of 861°C. Two ballooned regions and corresponding rupture openings were observed, with rupture widths of approximately 0.64 mm for both ruptures and rupture lengths of 4.8 mm and 5.6 mm, respectively.

Capps, Nathan [ORNL]↗

Dynamic security assessment of systems powered only by grid-forming power plants with uncertain dispatch using polynomial vectors

A modern challenge in power engineering is to perform the dynamic security assessment (DSA) of grids that are 100% powered by inverter-based resources (IBRs). Addressing this challenge is difficult because: (i) the dispatch of IBRs can be uncertain as a result of the variability of renewable resources and (ii) they have hard current control limits that cannot be neglected, contrasting synchronous machines. To address this problem, this paper sets forth a framework to conduct DSA of bulk power systems that are 100% powered by grid-forming IBRs. Furthermore, the framework considers that IBR operational conditions are unknown but bounded by a zonotope which is also expressed as a polynomial vector for uncertainty propagation via Dormand–Prince integration. The framework is applied to modified versions of the WSCC 9-bus and IEEE 39-bus grids.

14 SOLAR ENERGY↗

The value of long-duration energy storage under various grid conditions in a zero-emissions future

Long-duration energy storage (LDES) is a key resource in enabling zero-emissions electricity grids but its role within different types of grids is not well understood. Using the Switch capacity expansion model, we model a zero-emissions Western Interconnect with high geographical resolution to understand the value of LDES under 39 scenarios with different generation mixes, transmission expansion, storage costs, and storage mandates. We find that a) LDES is particularly valuable in majority wind-powered regions and regions with diminishing hydropower generation, b) seasonal operation of storage becomes cost-effective if storage capital costs fall below US$\$$5 kWh −1 , and c) mandating the installation of enough LDES to enable year-long storage cycles would reduce electricity prices during times of high demand by over 70%. Given the asset and resource diversity of the Western Interconnect, our results can provide grid planners in many regions with guidance on how LDES impacts and is impacted by energy storage mandates, investments in LDES research and development, and generation mix and transmission expansion decisions.

25 ENERGY STORAGE↗

Version 4 of the CRU TS monthly high-resolution gridded multivariate climate dataset

CRU TS (Climatic Research Unit gridded Time Series) is a widely used climate dataset on a 0.5° latitude by 0.5° longitude grid over all land domains of the world except Antarctica. It is derived by the interpolation of monthly climate anomalies from extensive networks of weather station observations. Here we describe the construction of a major new version, CRU TS v4. It is updated to span 1901–2018 by the inclusion of additional station observations, and it will be updated annually. The interpolation process has been changed to use angular-distance weighting (ADW), and the production of secondary variables has been revised to better suit this approach. This implementation of ADW provides improved traceability between each gridded value and the input observations, and allows more informative diagnostics that dataset users can utilise to assess how dataset quality might vary geographically.

54 ENVIRONMENTAL SCIENCES↗

A high resolution, gridded product for vapor pressure deficit using Daymet

Vapor pressure deficit (VPD) is a critical variable in assessing drought conditions and evaluating plant water stress. Gridded products of global and regional VPD are not freely available from satellite remote sensing, model reanalysis, or ground observation datasets. We present two versions of the first gridded VPD product for the Continental US and parts of Northern Mexico and Southern Canada (CONUS+) at a 1 km spatial resolution and daily time step. We derived VPD from Daymet maximum daily temperature and average daily vapor pressure and scale the estimates based on (1) climate determined by the Köppen-Geiger classifications and (2) land cover determined by the International Geosphere-Biosphere Programme. Ground-based VPD data from 253 AmeriFlux sites representing different climate and land cover classifications were used to improve the Daymet-derived VPD estimates for every pixel in the CONUS+ grid to produce the final datasets. We evaluated the Daymet-derived VPD against independent observations and reanalysis data. The CONUS+ VPD datasets will aid in investigating disturbances including drought and wildfire, and informing land management strategies.

54 ENVIRONMENTAL SCIENCES↗

LandScan mosaic enables high-resolution gridded population estimates with explicit uncertainty

Gridded population datasets represent high-resolution distributions of human occupancy, enabling informed decision-making across a broad range of fields. These data products are valuable for assessing environmental risk, urban development, disaster preparedness and resource allocation—areas where accurate population estimates directly enhance policy effectiveness and optimize resource distribution. Despite the importance of gridded population datasets, traditional population modeling approaches often overlook inherent uncertainties in the estimation process. This limitation can create a false sense of certainty in population estimates, potentially leading to flawed decisions by those who rely on the data. To address this methodological gap, we introduce a probabilistic machine learning modeling framework, LandScan Mosaic, that explicitly incorporates uncertainty into the population modeling process. Our approach systematically quantifies uncertainty in three key modeling parameters of the LandScan HD gridded population dataset: building use types, floor counts, and occupancy rates. By employing Monte Carlo simulations, we propagate these uncertainties through the modeling process, yielding probability distributions of population counts in place of deterministic point estimates. We demonstrate the practical application of this framework in Iloilo City, Philippines, using structured decision-making techniques and our probabilistic estimates to identify and prioritize areas most affected by projected flooding, supporting targeted interventions that address both economic and social risks. In doing so, we propose a population-specific approach for incorporating confidence into structured decision making processes. Through a comparative analysis with conventional deterministic approaches and point estimate approaches, including LandScan HD and WorldPop, we evaluate how the incorporation of machine learning and uncertainty influences decision rankings. This research advances population distribution modeling by offering a robust, quantitative approach that explicitly accounts for uncertainty in the underlying data, along with guidance for how users can apply uncertainty in their decision-making.

Environmental sciences↗

Spatial Impacts of Electric Vehicle Charging on Power Grid Stability: A Downtown Atlanta Case Study

The rapid increase in electric vehicle (EV) charging demand poses a potential risk to power grid stability, particularly as the spatial distribution of this demand remains underexplored. Existing research often focuses on technical optimization models while overlooking the geographic and human dynamics that affect energy consumption. This study addresses this gap by incorporating mobility data to estimate both building energy use and EV charging demand while also considering geographic factors for a better understanding of grid load. Using agent-based simulations and the Open-Source Distribution System Simulator, the study evaluates the effect of various EV penetration scenarios on grid voltage and unbalance. The results show that, although voltage remains within acceptable limits at lower EV penetration rates, significant voltage drop and unbalance occur as EV penetration exceeds 40%, particularly in residential areas with high charging demand. This study offers a framework for integrating spatial analysis and mobility data in power network simulations, providing insights for future EV infrastructure planning.

Pan, Melrose [ORNL] (ORCID:000000031627448X)↗

Evaluating power grid model hydropower feasibility with a river operations model

Production cost models (PCMs) simulate dispatch of generators across a large power grid and are used widely by planners to study the reliability of electricity supply. As energy systems transition away from the thermoelectric technologies that have traditionally balanced electricity supply and demand, hydropower and its representation in PCMs is of increasing importance. A limitation of PCMs applied to continental power grids with diverse generation portfolios is that hydropower generation is simulated without full consideration of complex river dynamics, leading to possible misrepresentation of grid flexibility and performance. In addition, data used in PCMs may reflect outdated operating policies. In this paper we propose a hydropower generation feasibility test for PCMs. The approach uses a detailed hydropower model to determine whether the hourly hydropower schedule from a PCM with simplified monthly parameterization can be attained after accounting for realistic river dynamics and operating policies, such as spill requirements and general water movement and balance through a cascade reservoir system. We perform this hydropower generation test for the ‘Big 10’ hydropower system on the Columbia River (part of the Western Interconnect of the United States), revealing 9% overestimation of available hydropower generation in a PCM solution in an average hydrologic year. Our evaluation provides insight on the cost and opportunities for better representing hydropower in PCMs.

54 ENVIRONMENTAL SCIENCES↗

Coordinating the electric vehicle transition and electricity grid decarbonization in the U.S. is not essential to achieving substantial long-term carbon dioxide emissions reductions

Abstract How quickly the US can decarbonize light-duty vehicle (LDV) transportation depends on the rates of change of electric vehicle (EV) sales, stock turnover, and grid decarbonization. We build a stock turnover model to assess how sensitive achieving 2050 LDV decarbonization targets is to these rates. We estimate carbon dioxide (CO 2 ) reductions of 70%–85% by 2050, including emissions from vehicles and upstream electricity generation, provided that new vehicle sales transition to 100% EVs and substantial grid decarbonization are accomplished by 2050. This result is robust to continuation of long-term trends of increasing vehicle longevity, and to whether the timing of EV sales growth and grid decarbonization are coordinated. If the two key goals are met, the annual contribution of EV electricity use to CO 2 emissions will be small over the entire period.

Leard, Benjamin↗

Multiple Grid-Forming Inverters in Black-Start: The Challenges

Black-start is a major challenge toward the successful operation of an islanded inverter-based system. In this article, the technical challenges for the black-start of multiple grid-forming inverters are reported. Specifically, this article discusses inverter synchronization, voltage and frequency regulation, and power-sharing between the grid-forming inverters. Experiment results from a multi-inverter test-bed have been provided to support the discussion. Furthermore, a grid-forming inverter controller for black-start operation is developed and presented in this article that addresses the discussed technical challenges. The performance of the developed controller in black-start operation is verified through experiment results.

Sadeque, Fahmid↗

Self-Security for Grid-Interactive Smart Inverters Using Steady-State Reference Model

Smart inverters exchange information with other devices through a shared communication link, making the inverters more prone to receive harmful commands from external parties. This erroneous data can be received due to an anomaly in the system, such as a device fault, unintentional utility operator action, or a cyber-attack. In this paper, a device-level self-security strategy is implemented using reference models for a grid-interactive inverter to examine the incoming power setpoints, detect the anomalies, and protect the system accordingly. The PQ setpoints received from the utility supervisory controller are autonomously examined using the inverter’s normal and stable operating regions before engaging the setpoints to the inverter’s local controller. Grid parameters are estimated in real-time during the examination process. The efficacy of the self-security algorithm is tested using a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative grid emulator. The results verify that the proposed method can detect harmful PQ setpoints that can cause abnormal or unstable inverter operation.

Gursoy, Mehmetcan↗

A Model-Reference Adaptive Direct-Power Control Scheme for Grid-Interactive Inverters

This paper develops an adaptive direct power control scheme for grid-interactive inverters while the control parameters are adaptively adjusted as the grid and filter parameters vary under different conditions. To demonstrate the efficacy and robustness of the adaptive operation, the performance of the adaptive controller is compared with a typical direct power controller by estimating the filter and grid impedances using a model reference parameter estimation technique with small signal injection. The simulation results verify that the developed methodology can track the reference power setpoints under output circuit parameter uncertainties while the typical design leads to instability. To improve the performance of the adaptive technique and eliminate the need for filter parameter estimation, a Lyapunov stability criterion-based model-reference adaptive direct power controller is designed to track the filter impedance. The developed method was tested using MATLAB/Simulink software to demonstrate the effectiveness of the proposed method. The results verify that adaptively tuning the control parameter can still maintain stable operation if the control gains are poorly selected while applying the classical method leads to abnormal operation or instability.

Gursoy, Mehmetcan↗

Vulnerability Assessments for Power-Electronics-Based Smart Grids

Here, in this paper, a novel method is proposed to evaluate the cyber security of the power-electronics-based smart grids (PESG). The proposed method considers the performance and stability of both the individual inverter and the grid. To our knowledge, this is a first attempt to evaluate the performance and stability of PESG due to cyber attacks. We first develop impedance-based modeling and cyber-attack modeling for PESG. Then we propose innovative two security criteria to evaluate the security of PESG, including stability-based and metrics-based. For metrics-based criteria, we propose to use both total harmonic distortion (THD) and space phasor model (SPM) to evaluate the inverter performance. The simulation results with a two-inverter-based power grid verify the validity and accuracy of the proposed security evaluation method. Results have shown that the performance and stability of PESG are significantly affected by cyber attacks, and thus there is indeed a need to further study cyber security issues of PESG.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Plug-and-Play Design Suite of Converters for the Electric Grid

Power electronic (PE) systems are increasingly being integrated into the electric grid in a distributed fashion. As the number of installations increases, the challenge of integration of these systems into the grid is also growing. Advanced control features of these systems are often overlooked or neglected due to the complex nature and novelty of these systems. This is also complicated from the vendor point of view as different converter topology integration is usually composed of single system designs with tight coupling and configurations. The presented work discusses a novel architecture for the integration of PE systems with other sources and loads to create a coordinated controllable resource for the grid. The presented work also describes a system level controller to coordinate these systems. 1 Testing results on a hardware in the loop (HIL) platform are provided to show the validity of the proposed architecture and framework.

Starke, Michael↗