Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GASES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

A Comparison of Measurements from ATMOS and Instruments Aboard the ER-2 Aircraft: Tracers of Atmospheric Transport and Halogenated Gases

We compare volume mixing ratio profiles of N2O, O3, NO(y), H2O, CH4, and CO in the mid-latitude lower stratosphere measured by the ATMOS Fourier transform spectrometer on the ATLAS-3 Space Shuttle Mission with in situ measurements acquired from the NASA ER-2 aircraft during Nov 1994. ATMOS and ER-2 observations of (N2O) show good agreement, as do measured correlations of (O3), (NO(y)), (H2O), and (CH4) with (N2O). Thus a consistent measure of the hydrogen (H2O, CH4) content of the lower stratosphere is provided by the two platforms. The similarity of (NO(y)) determined by detection of individual species by ATMOS and the total (NOy) measurement on the ER-2 provides strong corroboration for the accuracy of both techniques. A 25% discrepancy in lower stratospheric (CO) observed by ATMOS and the ER-2 remains unexplained. Otherwise, the agreement for measurements of long-lived tracers demonstrates the ability to combine ATMOS data with in situ observations for quantifying atmospheric transport.

Chang, A. Y.↗

Phenomenological Theory of the Translational Relaxation Times in Gases

The exact solution to the classical equations governing the translational dispersion and absorption of sound in a gas obscures its relaxational character because of its mathematical complexity. The approach taken here is to solve the secular equation by the method of Pade approximants, which even to the relatively low order R(sub 11) yields a remarkably close approximation to the exact solution over a wide range of frequency/pressure (f/P) ratios. As a result, translational relaxation can be formulated in terms of a conventional relaxation process with well-defined relaxation times, relaxation strength, collision numbers, additivity relations, etc. To extend the theory to high values of f/P ratio, a model is proposed to account for the noncontinuum behavior of the transport coefficients (viscosity and thermal conductivity) as the molecular mean free path approaches the acoustical enclosure dimensions. The theoretical dispersion and absorption show good agreement with measurements in argon over the classical and transition regions of f/P, but a discrepancy appears at higher values of f/P, where collective propagating modes, assumed in the theory, give way to single-particle modes, prevailing in the experiments.

Zuckerwar, Allan J.↗

Application of Derivative Spectrometry to the Analysis of Trace Gases

A derivative spectrometer is sensitive to changes in spectral intensity over narrow wavelength internal. Specifically, a second derivative spectrometer senses the curvature of the incident spectral intensity, providing an output voltage signal proportional to the second derivative of intensity with respect to wavelength. When such an instrument is combined with multi-pass White cell, a unique trace gas analyzer results. The analyzer, operating within the middle ultraviolet spectral region, provides a highly amplified derivative spectrum of any molecular narrow band absorption which is used for trace gas identification. The intensity of any peak within a spectrum is proportional to the trace gas concentration. Such an analyzer, utilizing a 20 meter pathlength White cell, is presently being used to automatically monitor ambient air for SO2, NO, NO2, and O3 with minimum detectable concentration limits in the part per billion range.

Hager, Robert N.↗

Horizontal Wavenumber Spectra of Winds, Temperature and Trace Gases During the Pacific Exploratory Missions: Gravity Waves, Quasi-Two-Dimensional Turbulence, and Vortical Modes - 2

We examine the horizontal wavenumber spectra of horizontal velocity and potential temperature collected by aircraft above the Pacific Ocean to determine whether gravity waves, quasi-two-dimensional (Q-2-D) turbulence, or vortical modes dominate atmospheric fluctuations at scale sizes of 1-100 km and altitudes of 2-12 km. We conclude from the study of Doppler-shifting effects that Q-2-D turbulence and/or vortical modes are more prevalent than gravity waves over the ocean, except in the equatorial zone. The results are consistent with recent numerical simulations of Q-2-D turbulence, which show that the characteristic inverse cascade of energy is greatly facilitated by the presence of background rotation. Furthermore, a Stokes-parameter analysis reveals the general paucity of coherent wavelike motions, although specific cases of gravity-wave propagation are observed. Finally, a case study of a long flight segment displays a k(sup -3) horizontal velocity variance spectrum at scales longer than about 100 km. A Stokes-parameter analysis indicates that these large-scale fluctuations were likely due to vortical modes rather than inertio-gravity waves.

Cho, John Y. N.↗

Fourier Transform Infrared (FT-IR) Spectroscopy of Atmospheric Trace Gases HCl, NO and SO2

Fourier Transform Infrared (FT-IR) spectral data have been recorded in the spectral region 400-4000/cm of hydrogen chloride and sulfur dioxide with I/cm resolution and of nitric oxide with 0.25 cm-i resolution, under quasi-static conditions, when the sample gas was passed through tubings of aluminum, copper, stainless steel and teflon. The absorbance was measured for the rotational lines of the fundamental bands of (1)H(35)Cl and (1)H(37)Cl for pressures in the range 100-1000 Torr and for the (14)N(16)O molecule in the range 100-300 Torr. The absorbance was also measured for individual rotational lines corresponding to the three modes of vibrations (upsilon(sub 1) - symmetric stretch, upsilon(sub 2) - symmetric bend, upsilon(sub 3) - anti-symmetric stretch) of the SO2 molecule in the pressure range 25-150 Torr. A graph of absorbance versus pressure was plotted for the observed rotational transitions of the three atmospherically significant molecules, and it was found that the absorbance was linearly proportional to the pressure range chosen, thereby validating Beer's law. The absorption cross-sections were determined from the graphical slopes for each rotational transition recorded for the HCl, NO and SO2 species. Qualitative and quantitative spectral changes in the FT-IR data will be discussed to identify and characterize various tubing materials with respect to their absorption features.

Haridass, C.↗

Remote Sensing of Volcanic Clouds: Sulfur Gases and Plume Top Topography

New absorption line parameters for H2S were published and submitted to the Gestion et Etude des Informations Spectroscopiques Atmospheriques (GEISA) and high resolution transmission molecular absorption (HITRAN) databases. These new absorption line parameters will make it possible to use observations from the future Tropospheric Emission Spectrometer (TES) instrument [Earth Observing System (EOS) Chemistry Mission (CHEM) platform] to make more accurate H2S measurements if it observes an H2S-rich volcanic cloud. H2S is the second most abundant volcanic sulfur gas, and like SO2, it also converts to H2SO4 aerosols and can have a climate impact. A paper on the Moderate-resolution Imaging-Spectroradiometer (MODIS) SO2 alert is being revised. New aspects in the revision include verification of the SO2 alert during the EOS mission; factors affecting SO2 detection at thermal infrared, ultraviolet, and microwave wavelengths; radiative transfer tests; more description of satellite instruments; and thermal surface alert installed for MODIS. Her research involves the use of remote sensing to generate maps of plume top altitude. This parameter is important for models of volcanic eruption, aircraft hazards, and climate impact. The topographic shape of the top surface of a volcanic plume can provide information necessary to understand the physics controlling the injection and dispersal of a volcanic plume in the atmosphere. Glaze et al. describe the application of a photoclinometric technique to volcanic plumes. The software algorithm has been improved to account for more general plume and illumination geometries and for easily extracting position information directly from Advanced Very High-Resolution Radiometer (AVHRR) level 1B data. Testing of the algorithm has focused on acquiring AVHRR data for a variety of volcanic plumes in an effort to identify problems with the software as well as model sensitivities. The plumes chosen were erupted from volcanoes at a variety of latitudes, at different times of day, and in different seasons. Another important issue that is being investigated is the importance of plume opacity. A diagram illustrates the method for deriving phi, the angle a wind-blown plume makes with the horizontal, in the direction perpendicular to the remote sensing scan. A figure shows a sample output of the algorithm, a wire mesh map of plume top topography. Additional information is contained in the original.

Crisp, Joy A.↗

Measurement of HO2 And Other Trace Gases in The Stratosphere Using a High Resolution Far-Infrared Spectrometer

This report covers the time period 1 April 1999 to 31 March 2000. During this period we continued analyzing data from past flights, exploring issues such as radical partitioning, stratospheric transport, and stratosphere-troposphere exchange. With funding from Smithsonian we have also completed a preliminarY design for a compact, lightweight, next-generation Fourier-transform spectrometer.

Traub, Wesley A.↗

Isentropic Compression of Multicomponent Mixtures of Fuels and Inert Gases

In selected aerospace applications of the fuels hydrazine and monomethythydrazine, there occur conditions which can result in the isentropic compression of a multicomponent mixture of fuel and inert gas. One such example is when a driver gas such as helium comes out of solution and mixes with the fuel vapor, which is being compressed. A second example is when product gas from an energetic device mixes with the fuel vapor which is being compressed. Thermodynamic analysis has shown that under isentropic compression, the fuels hydrazine and monomethylhydrazine must be treated as real fluids using appropriate equations of state. The appropriate equations of state are the Peng-Robinson equation of state for hydrazine and the Redlich-Kwong-Soave equation of state for monomethylhydrazine. The addition of an inert gas of variable quantity and input temperature and pressure to the fuel compounds the problem for safety design or analysis. This work provides the appropriate thermodynamic analysis of isentropic compression of the two examples cited. In addition to an entropy balance describing the change of state, an enthalpy balance is required. The presence of multicomponents in the system requires that appropriate mixing rules are identified and applied to the analysis. This analysis is not currently available.

Barragan, Michelle↗

Evaluating Mass Analyzers as Candidates for Small, Portable, Rugged Single Point Mass Spectrometers for Analysis of Permanent Gases

For Space Shuttle launch safety, there is a need to monitor the concentration Of H2, He, O2, and Ar around the launch vehicle. Currently a large mass spectrometry system performs this task, using long transport lines to draw in samples. There is great interest in replacing this stationary system with several miniature, portable, rugged mass spectrometers which act as point sensors which can be placed at the sampling point. Five commercial and two non-commercial analyzers are evaluated. The five commercial systems include the Leybold Inficon XPR-2 linear quadrupole, the Stanford Research (SRS-100) linear quadrupole, the Ferran linear quadrupole array, the ThermoQuest Polaris-Q quadrupole ion trap, and the IonWerks Time-of-Flight (TOF). The non-commercial systems include a compact double focusing sector (CDFMS) developed at the University of Minnesota, and a quadrupole ion trap (UF-IT) developed at the University of Florida.

Arkin, C. Richard↗

Radiative Interaction Between Driver and Driven Gases in an Arc-Driven Shock Tube

An electric-arc driven shock tube was operated with hydrogen as the driven gas and either hydrogen or helium as the driver gas. Electron density was measured behind the primary shock wave spectroscopically from the width of the Beta line of hydrogen. The measured electron density values were many times greater than the values calculated by the Rankine - Hugoniot relations. By accounting for the radiative transfer from the driver gas to the driven gas, the measured electron density values were numerically recreated.

Bogdanoff, David W.↗

Separation and Conditioning of Mars Atmospheric Gases via TSA

Space and planetary exploration almost always presents interesting and unusual engineering challenges. Separations engineering for chemical processes that are critical to humans working in space is no exception. The challenges are becoming clearer as we make the transition from concepts and planning to hardware development, and as we understand better the constraints and environments in which the processes must perform. The coming decade will see a robotic Mars exploration program that has recovered from recent setbacks and is building a knowledge and technology base for human exploration. One of the missions will carry a small chemical pilot plant for demonstrating the manufacture of rocket propellants and life support consumables from the low-pressure (0.01 atm) Martian atmosphere. By manufacturing and storing the fuel and consumables needed for human-return missions in situ, launch mass and landed mass are reduced by tons and missions become far less expensive. The front-end to the pilot plant is a solid-state atmosphere acquisition and separation unit based on temperature-swing adsorption (TSA). The unit produces purified and pressurized (to 1.0 atm) carbon dioxide to downstream reactors that will make methane and oxygen. The unit also produces a nitrogen-argon mixture as a valuable by-product for life support, inflatable structures, and propellant pressurization. With nighttime temperatures falling to -100 degrees C, power availability restricted to a few watts, and flawless operation critical to success, the dusty Martian surface is a difficult place to operate a remote plant. This talk will focus on how this TSA separation process is designed and implemented for this application, and how it might be used in the more distant future for human exploration.

Finn, John E.↗

Evaluating Mass Analyzers as Candidates for Small, Portable, Rugged Single Point Mass Spectrometers for Analysis of Permanent Gases

For Space Shuttle launch safety, there is a need to monitor the concentration of H2, He, O2 and Ar around the launch vehicle. Currently a large mass spectrometry system performs this task, using long transport lines to draw in samples. There is great interest in replacing this stationary system with several miniature, portable, rugged mass spectrometers which act as point sensors which can be placed at the sampling point. Five commercial and two non-commercial analyzers are evaluated. The five commercial systems include the Leybold Inficon XPR-2 linear quadrupole, the Stanford Research (SRS-100) linear quadrupole, the Ferran linear quadrupole array, the ThermoQuest Polaris-Q quadrupole ion trap, and the IonWerks Time-of-Flight (TOF). The non-commercial systems include a compact double focusing sector (CDFMS) developed at the University of Minnesota, and a quadrupole ion trap (UF-IT) developed at the University of Florida. The System Volume is determined by measuring the entire system volume including the mass analyzer, its associated electronics, the associated vacuum system, the high vacuum pump and rough pump. Also measured are any ion gauge controllers or other required equipment. Computers are not included. Scan Time is the time required for one scan to be acquired and the data to be transferred. It is determined by measuring the time required acquiring a known number of scans and dividing by said number of scans. Limit of Detection is determined first by performing a zero-span calibration (using a 10-point data set). Then the limit of detection (LOD) is defined as 3 times the standard deviation of the zero data set. (An LOD of 10 ppm or less is considered acceptable.)

Arkin, C. Richard↗

Submillimeter Spectra of Low Temperature Gases and Mixtures

Submillimeter absorption spectra of nitrogen, nitrogen-argon mixtures, and methane have been measured using temperatures and pressures near to those found in the atmospheres of Titan and Saturn. The experiments show the spectral signature of dimers which will likely appear in far-infrared spectra of Titan that will be obtained by the Composite Infrared Spectrometer (CIS) onboard the Cassini spacecraft. The recent CIRS spectrum of Jupiter shows far-infrared spectral lines of methane and the corresponding lines are observed in the laboratory. We are extending this work to lower frequencies using a new differential Michelson interferometer that operates over the frequency region 3-30 1/cm..

Wishnow, E. H.↗

Investigations of Compression Shocks and Boundary Layers in Gases Moving at High Speed

The mutual influences of compression shocks and friction boundary layers were investigated by means of high speed wind tunnels.Schlieren optics provided a clear picture of the flow phenomena and were used for determining the location of the compression shocks, measurement of shock angles, and also for Mach angles. Pressure measurement and humidity measurements were also taken into consideration.Results along with a mathematical model are described.

Ackeret, J.↗