Diffusion of Hydrophilic to Hydrophobic Forms of Nile Red in Aqueous C 12 EO 10 Gels by Variable Area Fluorescence Correlation Spectroscopy

In this work, solute diffusion within lyotropic liquid crystal gels prepared from a series of water and decaethylene glycol monododecyl ether (C 12 EO 10 ) mixtures was explored by variable area fluorescence correlation spectroscopy. Aqueous C 12 EO 10 gels were prepared in concentrations ranging from 55:45 to 70:30 wt% of surfactant and water. Small angle X-ray scattering revealed that these gels comprise hexagonal mesophases of cylindrical micelles. Micelle spacing was found to decrease with increasing C 12 EO 10 concentration. Three different Nile red (NR) dyes were employed as model solutes and were separately doped into the gels at nanomolar levels. These include a hydrophilic form of NR incorporating an anionic sulfonate group (NRSO 3 - ), a hydrophobic form incorporating a fourteen-carbon alkane tail (NRC 14 ), and commercial NR as an intermediate case. FCS data acquired from the gels revealed that NRSO 3 - diffused primarily in 3D. Its diffusion coefficient exhibited a monotonic decrease with increasing gel concentration and micelle packing density, consistent with confinement of its motions as a result of its exclusion from the micelle cores. NRC 14 exhibited the smallest diffusion coefficient, most likely due to its larger size and enhanced interactions with the micelle cores. NR yielded an intermediate diffusion coefficient and the most anomalous behavior of the three dyes, attributable to its facile partitioning between core and corona regions, and greater participation by 1D diffusion. The results of these studies afford an improved understanding of molecular mass transport through soft-matter nanomaterials like those being developed for use in drug delivery and membrane based chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Xenon ion laser-induced fluorescence using a visible tunable diode laser near 680 nm

Laser-induced fluorescence (LIF) measurements have been performed for the first time in a low temperature (T{sub e}{approx_equal}0.6 eV) Xe plasma using a tunable diode laser in the visible range of wavelengths. The transition in Xe II involved the ({sup 3}P{sub 1})5d[3]{sub 7/2} metastable state and the excitation wavelength was found to be 680.570{+-}0.001 nm (air). LIF measurements of I{sub 2} in a room temperature iodine gas cell were used to monitor the wavelength of the laser during the measurements.

74 ATOMIC AND MOLECULAR PHYSICS↗

Glass tube of high dielectric constant and low dielectric loss for external electrode fluorescent lamps

A glass tube of aluminosilicate glass, with high dielectric constant K{approx}6.0 and low dielectric loss tan {delta}{approx}8.0x10{sup -4}, was investigated for the external electrode fluorescent lamps (EEFLs) of a dielectric barrier discharge. Compared with conventional EEFLs made out of borosilicate glass tubes with K{approx}(4.9-5.3) and tan {delta}{approx}(2.3-2.4)x10{sup -3}, the efficiency of the aluminosilicate EEFL increases by 15%-25% even at high luminance above 20 000 cd/m{sup 2} and the pinhole stability of the aluminosilicate EEFL also improves remarkably. In a soda-lime glass EEFL with a high dielectric loss tan {delta}{approx}7.0x10{sup -3}, the luminance and pinhole stability deteriorate even with a high dielectric constant K{approx}7.2 at room temperature, because the value of tan {delta} escalates as the temperature on the external electrode increases due to the dielectric heat dissipation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron plasma wave propagation in external-electrode fluorescent lamps

The optical propagation observed along the positive column of external electrode fluorescent lamps is shown to be an electron plasma wave propagating with the electron thermal speed of (kT{sub e}/m){sup 1/2}. When the luminance of the lamp is 10 000-20 000 cd/m{sup 2}, the electron plasma temperature and the plasma density in the positive column are determined to be kT{sub e}{approx}1.26-2.12 eV and n{sub o}{approx}(1.28-1.69)x10{sup 17} m{sup -3}, respectively.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of Essential Element Distribution in the Equine Metacarpophalangeal Joint using a Synchrotron Radiation Micro X-Ray Fluorescence Technique

In articular cartilage, Ca, P, K and S are among some of the well known co-factors of the metalloproteinases enzymatic family, the latter playing a pivotal role in the growth and degeneration of the collagenous bone-cartilage interface of articulating joints. Current study forms part of a larger investigation concerning the distribution of these and other key elements in such media. For the purpose of evaluating these low atomic number elements (Z{<=}20), use was made of the capabilities of the LUCIA Station, located at the synchrotron facility of the Paul Scherrer Institute (PSI). Using an incident radiation energy of 4.06 keV, a synchrotron radiation micro x-ray fluorescence (SR-{mu}XRF) technique was applied in examining the distribution of the essential elements Ca, P, K and S in the bone-cartilage interface of both healthy and diseased (osteoarthritic) areas of an equine metacarpophalangeal joint. The SR-{mu}XRF mappings and line profile patterns have revealed remarkable changes in both the pattern and absolute distributions of these elements, agreeing with the findings of others. The elemental presence shown in the individual area scans encompassing the lesion each reflect the visibly abraded outer surface of the cartilage and change in shape of the bone surface. One of the area scans for the bone-cartilage interface shows a marked change in both the pattern and absolute elemental presence for all three elements compared to that observed at two other scan sites. The observation of change in bone cartilage composition around the surface of the articulating joint is thought to be novel, the variation being almost certainly due to the differing weight-bearing role of the subchondral bone at each locati0008.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of gridded energy analyzer and laser induced fluorescence measurements of a two-component ion distribution

We present ion velocity distribution function (IVDF) measurements obtained with a five grid retarding field energy analyzer (RFEA) and IVDF measurements obtained with laser induced fluorescence (LIF) for an expanding helicon plasma. The ion population consists of a background population and an energetic ion beam. When the RFEA measurements are corrected for acceleration due to the electric potential difference across the plasma sheath, we find that the RFEA measurements indicate a smaller background to beam density ratio and a much larger parallel ion temperature than the LIF. The energy of the ion beam is the same in both measurements. These results suggest that ion heating occurs during the transit of the background ions through the sheath and that LIF cannot detect the fraction of the ion beam whose metastable population has been eliminated by collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantifying the number of color centers in single fluorescent nanodiamonds by photon correlation spectroscopy and Monte Carlo simulation

The number of negatively charged nitrogen-vacancy centers (N-V){sup -} in fluorescent nanodiamond (FND) has been determined by photon correlation spectroscopy and Monte Carlo simulations at the single particle level. By taking account of the random dipole orientation of the multiple (N-V){sup -} fluorophores and simulating the probability distribution of their effective numbers (N{sub e}), we found that the actual number (N{sub a}) of the fluorophores is in linear correlation with N{sub e}, with correction factors of 1.8 and 1.2 in measurements using linearly and circularly polarized lights, respectively. We determined N{sub a}=8{+-}1 for 28 nm FND particles prepared by 3 MeV proton irradiation.

36 MATERIALS SCIENCE↗

Fluorescence decay-time constants in organic liquid scintillators

The fluorescence decay-time constants have been measured for several scintillator mixtures based on phenyl-o-xylylethane (PXE) and linear alkylbenzene (LAB) solvents. The resulting values are of relevance for the physics performance of the proposed large-volume liquid scintillator detector Low Energy Neutrino Astronomy (LENA). In particular, the impact of the measured values to the search for proton decay via p{yields}K{sup +}{nu} is evaluated in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging and Radiography with Nuclear Resonance Fluorescence and Effective-Z (EZ-3D) Determination; SNM Detection Using Prompt Neutrons from Photon Induced Fission

Four new technologies have been developed for use in non-intrusive inspection systems to detect nuclear materials, explosives and contraband. Nuclear Resonance Fluorescence (NRF) provides a three dimensional image of the isotopic content of a container. NRF determines the isotopic composition of a region and specifies the isotopic structure of the neighboring regions, thus providing the detailed isotopic composition of any threat. In transmission mode, NRF provides a two dimensional projection of the isotopic content of a container, much as standard X-ray radiography provides for density. The effective-Z method (EZ-3D) uses electromagnetic scattering processes to yield a three-dimensional map of the effective-Z and the density in a container. The EZ-3D method allows for a rapid discrimination based on effective Z and mass of materials such as those with high Z, as well as specifying regions of interest for other contraband. The energy spectrum of prompt neutrons from photon induced fission (PNPF) provides a unique identification of the presence of actinides and SNM. These four new technologies can be used independently or together to automatically determine the presence of hazardous materials or contraband. They can also be combined with other technologies to provide added specificity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray Fluorescence (XRF) Assay Using Laser Compton Scattered (LCS) X-rays

Laser Compton Scattered (LCS) X-rays are produced as a result of the interaction between accelerated electrons and a laser beam. The yield of LCS X-rays is dependent on the laser power, angle of collision between interacting particles, and the electron linear accelerator's (linac) electron beam energy and its current. One of our research goals at the Idaho Accelerator Center (IAC) focuses on applications such as detection and imaging of fissionable isotopes for nuclear non-proliferation, safeguards and homeland security. Quasi monochromatic LCS X-rays offer much better signal-to-noise ratios for such applications. The energy of LCS X-rays is tunable, that enable element-specific analysis. Two sharp 36.5 keV and 98.4 keV LCS peaks were observed in two separate experiments based on electron beams tuned at 32 MeV and 37 MeV, that were brought in collision with the (Power){sub peak} = 4 GW Nd.YAG laser operating at 532 nm and 266 nm wavelengths. The linac was operating at 60 Hz with an electron beam pulse length of about 50 ps and a peak current of about 7 A. We exploited X-ray fluorescence (XRF) techniques to identify elemental K{alpha}{sub 1}, K{alpha}{sub 2}, and K{beta}{sub 1} lines in a high-purity germanium (HPGe) detector, with a 0.5 mm thick Beryllium (Be) absorbing layer, emitted from tin (Sn), cadmium (Cd), silver (Ag), gold (Au), and lead (Pb) foils with thicknesses ranging from 25-500 {mu}m, following absorption of 36.1 keV and 98.4 keV LCS X-rays. These reference foils were used for the proof of principle, and some have atomic numbers near to that of relevant fission products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescent X-Ray Computed Tomography towards Molecular Imaging: Proof-of-Concept Experiments

By means of fluorescent x-ray computed tomography (FXCT) one can detect and image a distribution of non-radioactive imaging agent, e.g., iodine, in a biomedical subject at a high spatial resolution, so it can be a novel molecular imaging modality. We have been studying an FXCT system using synchrotron radiation for in-vivo imaging brains of small animals such as mouse, or rat. For the purpose, we propose a fast FXCT imaging method based on the novel geometry. In this study, we prove the feasibility of this concept and investigate its imaging properties, including spatial and contrast resolutions and quantitativeness, by imaging an acrylic phantom and a normal mouse brain using a preliminary imaging system with monochromatic synchrotron x rays.

60 APPLIED LIFE SCIENCES↗

High resolution laser induced fluorescence Doppler velocimetry utilizing saturated absorption spectroscopy

A high resolution laser induced fluorescence (LIF) system has been developed to measure the flow velocity field of neutral particles in an electron-cyclotron-resonance argon plasma. The flow velocity has been determined by the Doppler shift of the LIF spectrum, which is proportional to the velocity distribution function. Very high accuracy in velocity determination has been achieved by installing a saturated absorption spectroscopy unit into the LIF system, where the absolute value and scale of laser wavelength are determined by using the Lamb dip and the fringes of a Fabry-Perot interferometer. The minimum detectable flow velocity of a newly developed LIF system is {+-}2 m/s, and this performance remains unchanged in a long-time experiment. From the radial measurements of LIF spectra of argon metastable atoms, it is found that there exists an inward flow of neutral particles associated with neutral depletion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser induced fluorescence of the ferroelectric plasma source assisted hollow anode discharge

Parameters of the plasma produced by a ferroelectric plasma source (FPS) assisted high-current ({approx}1 kA), hollow anode (HA), low-pressure (10{sup -4} Torr) Ar gas discharge were studied using a time- and space-resolved laser induced fluorescence (LIF) diagnostic technique. It was shown that the plasma filling of the HA cavity occurs due to the expansion of the plasma flows generated by the FPSs with a gradual time-dependent increase in the plasma density along the length of the HA cavity. These data were verified by the results of one-dimensional modeling of the plasma expansion in vacuum and time-dependent collisional-radiative modeling. Also, LIF diagnostics, which was tested on the saturation effect both experimentally and numerically, showed that the plasma ion temperature gradually increases during the discharge reaching {approx}9 eV at its end. Various phenomena (plasma kinetic instabilities, charge-exchange processes during the plasma ion interaction with the HA walls, and the model of neutral atoms ionization inside the Debay's sphere), which could be responsible for such ion temperature, were considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Subwavenumber charge-coupled device spectrometer calibration using molecular iodine laser-induced fluorescence

Spectrometers configured with charge-coupled devices (CCD) or other array-based detectors require calibration to convert from the pixel coordinate to a spectral coordinate. A CCD calibration method well suited for Raman spectroscopy has been developed based on the 514.5 nm Ar{sup +} laser-induced fluorescence (LIF) spectrum of room-temperature molecular iodine vapor. Over 360 primary and secondary I{sub 2} LIF calibration lines spanning 510-645 nm were identified as calibrant peaks using an instrumental resolution of 1 cm{sup -1}. Two instrument calibration functions were evaluated with these peaks: a second-order polynomial and a function derived from simple optomechanical considerations. The latter function provided better fitting characteristics. Calibration using I{sub 2} LIF was tested with measurements of both laser light scattering and Raman spectra. The I{sub 2} LIF reference spectra and the signal spectra were recorded simultaneously, with no cross talk, by separating the two signals spatially along the vertical axis of the CCD imager. In this way, every CCD image could be independently calibrated. An accuracy and a precision of {+-}0.05 cm{sup -1} were achieved with this calibration technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intense 1.54 {mu}m fluorescence of Er{sup 3+}/Yb{sup 3+} codoped phosphate glass and the three-photon phenomenon of near infrared upconversion luminescence

Transparent P{sub 2}O{sub 5}-CaO-Na{sub 2}O glasses codoped with Er{sup 3+} and Yb{sup 3+} ions were fabricated by high-temperature melting technique. Strong near infrared and visible upconversion luminescence were observed under 975 nm laser diode excitation, and the luminescence processes were explained in details. For 1.54 {mu}m band, the calculated peak emission cross sections is 1.04x10{sup -20} cm{sup 2}, and it is better than that in germinate, tellurite, silicate, and other phosphate glasses. The near infrared upconversion emission around 828 nm contains two-photon and three-photon processes, and it is attributed to the transition {sup 4}S{sub 3/2}{yields}{sup 4}I{sub 13/2}, which enhances the population of the upper level for 1.54 {mu}m laser emission and reduces the energy loss due to upconversion. Efficient near infrared fluorescence indicates Er{sup 3+}/Yb{sup 3+} codoped phosphate glass is a promising laser and amplifier material.

36 MATERIALS SCIENCE↗

Quantitative Elemental Microanalysis Of Individual Particles With Use Of X-Ray Fluorescence Method And Monte Carlo Simulation

Recently a considerable interest has been triggered in the investigation of the composition of individual particles by X-ray fluorescence microanalysis. The sources of these micro-samples are mostly diversified. These samples come from space dust, air and ash, soil as well as environment and take the shape of a sphere or an oval. In analysis this kind of samples the geometrical effects caused by different sizes and shapes influence on accuracy of results. This fact arises from the matrix effect. For these samples it is not possible to find analytically a solution of equation taking into account an absorption of X-rays. Hence, a way out is to approximate the real sample shape with the other one or to use Monte Carlo (MC) simulation method. In current work authors utilized the iterative MC simulation to assess an elemental percentage of individual particles. The set of glass micro-spheres, made of NIST K3089 material of known chemical composition, with diameters in the range between 25 and 45 {mu}m was investigated. The microspheres were scanned with X-ray tube primary radiation. Results of MC simulation were compared with these of some analytical approaches based on particle shape approximation. An investigation showed that the low-Z elements (Si, Ca, Ti) were the most sensitive on changes of particle shape and sizes. For high-Z elements (Fe--Pb) concentrations were nearly equal regardless of method used. However, for the all elements considered, results of MC simulation were more accurate then these of analytical relationships taken into comparison.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous Flow Cryostat for X-Ray Fluorescence

A continuous Helium flow cryostat was designed and built by Cryovac GMbH to specifications given by ESRF beamline ID26. The beamline has constructed a high energy resolution X-ray emission spectrometer using multiple spherically bent analyser crystals, together with the sample and detector on a vertical Rowland circle. The double shrouded cryostat has a low profile designed to fit into the spectrometer setup, the lowest detector position allows for a Bragg angle of 85 degrees with a 1 meter diameter Rowland circle. The cryostat has a temperature range of 5 to 300 Kelvin on the sample holder which is cooled by static Helium exchange gas. The cryostat has triple windows for beam entrance, transmission and fluorescence; the latter offers an opening angle of 80 degrees horizontally and 50 degrees vertically. The cryostat can be configured to work in two different operation modes: translation or rotation. The translation mode offers a displacement of 50 mm to accommodate multiple samples on the sample holder. The rotation mode is used for polarisation studies on single crystals.We show recent results obtained on Chromium containing molecular complexes; data collection was done at a temperature of 10 Kelvin to avoid radiation damage.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗