Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Loop Heat Pipe with Thermal Control Valve as a Variable Thermal Link

Future lunar landers and rovers will require variable thermal links that allow for heat rejection during the lunar daytime and passively prevent heat rejection during the lunar night. During the lunar day, the thermal management system must reject the waste heat from the electronics and batteries to maintain them below the maximum acceptable temperature. During the lunar night, the heat rejection system must either be shut down or significant amounts of guard heat must be added to keep the electronics and batteries above the minimum acceptable temperature. Since guard heater power is unfavorable because it adds to system size and complexity, a variable thermal link is preferred to limit heat removal from the electronics and batteries during the long lunar night. Conventional loop heat pipes (LHPs) can provide the required variable thermal conductance, but they still consume electrical power to shut down the heat transfer. This innovation adds a thermal control valve (TCV) and a bypass line to a conventional LHP that proportionally allows vapor to flow back into the compensation chamber of the LHP. The addition of this valve can achieve completely passive thermal control of the LHP, eliminating the need for guard heaters and complex controls.

Hartenstine, John↗

Control system design for maintaining CO{sub 2} capture in IGCC power plants while loading-following

Load-following requirements for future integrated gasification combined cycle (IGCC) power plants with precombustion CO{sub 2} capture are expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. In this work, loadfollowing studies are performed using a comprehensive dynamic model of an IGCC plant with pre-combustion CO{sub 2} capture developed in Aspen Engineering Suite (AES). Considering multiple single-loop controllers for power demand load following, the preferred IGCC control strategy from the perspective of a power producer is gas turbine (GT) lead with gasifier follow. In this strategy, the GT controls the load by manipulating its firing rate while the slurry feed flow to the gasifier is manipulated to control the syngas pressure at the GT inlet. The syngas pressure control is an integrating process with significant time delay mainly because of the large piping and equipment volumes between the gasifier and the GT inlet. A modified proportional–integral–derivative (PID) control is considered for IGCC syngas pressure control. The desired CO{sub 2} capture rate must be maintained while the IGCC plant follows the load. For maintaining the desired CO{sub 2} capture rate, the control performance of PID control is compared with linear model predictive control (LMPC). The results show that the LMPC outperforms PID control for maintaining CO{sub 2} capture rates in an IGCC power plant while load following.

20 FOSSIL-FUELED POWER PLANTS↗

Optimization design of helium circulator diffuser in HTR-PM - 18488

Circulator is very important in HTR-PM. It needs to supply enough pressure rise to circulate cooled helium in the primary loop of HTR-PM to bring heat out. Its pressure rise requirement is the highest among the worldwide circulators. Diffuser is one main component to produce pressure rise for circulator. And the most particular for HTR-PM is that the helium must flow out from two round tubes after flowing through the diffuser, which is very different from other circulators. This special export structure increases flow loss and decreases diffuser efficiency. So it is necessary to optimize diffuser to satisfy high pressure rise requirement of HTR-PM circulator with the special export structure. Four geometrical variables of diffuser have been studied and optimized. Based on the flow and performance analysis, the optimum structure was chosen. Then the detailed simulation was done by combining it with impeller to obtain performance characteristics of the whole circulator. Finally, the simulation results were compared with experimental results. It was obtained that simulation pressure rise was 201 kPa and experimental result was 210 kPa, which verified that optimization design of diffuser was effective. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Aeroelastic Response of Swept Aircraft Wings in a Compressible Flow Field

The present study addresses the subcritical aeroelastic response of swept wings, in various flight speed regimes, to arbitrary time-dependent external excitations. The methodology based on the concept of indicial functions is carried out in time and frequency domains. As a result of this approach, the proper unsteady aerodynamic loads necessary to study the subcritical aeroelastic response of the open/closed loop aeroelastic systems, and of flutter instability, respectively are obtained. Validation of the aeroelastic model is provided, and applications to subcritical aeroelastic response to blast pressure signatures are illustrated. In this context, an original representation of the aeroelastic response in the phase-space is displayed, and pertinent conclusions on the implications of a number of selected parameters of the system are outlined.

Marzocca, Piergiovanni↗

Active learning for the design of polycrystalline textures using conditional normalizing flows

Generative modeling has opened new avenues for solving previously intractable materials design problems. However, these new opportunities are accompanied by a drastic increase in the required amount of training data. This is in stark juxtaposition to the high expense and difficulty in curating such large materials datasets. In this work, we propose a novel framework for integrating generative models within an active learning loop. Further, this enables the training of generative models with datasets significantly smaller than what has previously been demonstrated, providing a direct route for their application in data constrained environments. The functionality of this framework is then demonstrated by addressing the challenge of designing polycrystalline textures associated with target anisotropic mechanical properties. The developed protocol exhibited a cost reduction between 14 to 18 times over a randomly sampled experimental design.

36 MATERIALS SCIENCE↗

Large-scale structure from cosmic-string loops in a baryon-dominated universe

The results are presented of a numerical simulation of the formation of large-scale structure in a universe with Omega(0) = 0.2 and h = 0.5 dominated by baryons in which cosmic strings provide the initial density perturbations. The numerical model yields a power spectrum. Nonlinear evolution confirms that the model can account for 700 km/s bulk flows and a strong cluster-cluster correlation, but does rather poorly on smaller scales. There is no visual 'filamentary' structure, and the two-point correlation has too steep a logarithmic slope. The value of G mu = 4 x 10 to the -6th is significantly lower than previous estimates for the value of G mu in baryon-dominated cosmic string models.

Melott, Adrian L.↗

Multiphysics Time-Integration for Turbulent Combustion at the Exascale

Turbulent reacting flow systems are often modeled with coupled time-dependent partial differential equations (PDEs). Solving such equations can easily tax the world's largest supercomputers. One pragmatic strategy for attacking such problems is to split the PDEs into components that can more easily be solved in isolation. This generic operator-splitting strategy leads to a set of ordinary differential equations (ODEs) that need to be solved as part of an "outer-loop" time-stepping approach. In many combustion applications, the ODEs to be solved can be very stiff, exhibiting timescales that span many orders of magnitude. The SUNDIALS library provides a plethora of robust time integration algorithms for solving these ODEs on exascale-capable computing hardware, yet for many complex applications (such multicomponent fuels or emissions predictions), the chemical models remain too complex to solve using reasonable resources. The Quasi-Steady State Approximation (QSSA) can be an effective tool for reducing the size and stiffness of the simulations. In this talk, I will discuss the use of the SUDIALS library of ODE solvers together with automatic code generation tools to solve complex turbulent reacting flow problems using QSSA models.

chemistry↗

Salt Vessel-Sample Generator Interface

The goal of the salt sampling program at Argonne is to develop and deploy automated molten salt sampling approaches for interfacing relevant unit operations with salt analysis to improve the timeliness and accuracy of sampling-based accountancy measurements. One technology under development is a vacuum sampler loop module. In this system, molten salt is drawn from a process vessel through a heated sampling line and into a charge vessel. Next, one or more samples are split from the volume in the charge vessel and the remaining salt is returned to the process. The vacuum sampler loop module is being developed to interface with other sample processing and analysis modules to enable rapid at-line sample characterization. The main purpose of the vacuum sampling loop module is to enable the collection of samples that are more representative of the bulk salt by replacing traditional point samplers (i.e., dip probes) with a sampling approach that captures a larger cross section of salt. Additionally, the vacuum sampling approach eliminates the risk of dross contamination of samples and avoids the use of moving parts in the salt. Two methods of interfacing the vacuum sampling loop with a precision pneumatic sample generator were investigated in FY21. This report covers the testing of fluidic coupling between the two modules. Two iterations of the fluidically coupled modules were tested. The first iteration system coupled the two modules using a freeze valve to seal the vacuum sampler during filling and to control flow into the pneumatic sample generator. While this integrated system functioned as intended, some changes were implemented to make the system more robust and better suited to remote deployment. Specifically, the system was made to be more modular and active control of the vacuum filling operation was replaced with a passive control mechanism. For passive filling, the salt charge vessel was vented to a small gas tank that was at negative pressure, causing salt to be drawn into the vessel until the force of the fluid head was in equilibrium with the gas pressure. The passive control system performed well and will be used in future iterations. Another change in the second system was a newly configured pneumatic sample generator in which sample ejection occurred through a hole in the reservoir’s stainless-steel side wall instead of through a non-wetted sapphire orifice on the bottom. This alternate configuration may be better suited for near-process deployment because it enables on-line orifice maintenance and an orifice bypass drain back to the process. A third change in the second iteration system was the transition to a two-chamber charge vessel which split off a fraction of the sampled salt as a liquid aliquot. The goal was to create a buffer mechanism that would allow reproducible aliquoting of samples, independently of variability in the charge vessel fill height. While the two-chamber design was functional, the sample size reproducibility was below target values. To improve reproducibility and overcome many of the impediments to remote deployment of the vacuum sampling loop module, separate work was conducted to replace the two-chamber liquid aliquoting mechanism with aliquoting into single-use sample tubes. Solid salt transfer in the sample tubes will replace fluidic coupling for integrating the vacuum sampler with downstream modules. Because the proposed operations can all be executed with simple overhead actuation mechanisms or other existing hot-cell technology, there will be no need for large investments in novel hot cell sample handling technologies using this alternate approach. As such, near-term deployment of the vacuum sampling technology will be achievable. This new approach for automated coupling of sample tubes with down-stream modules is covered in a separate FY21 report, and a remotely operated version of the vacuum sampler loop module with the tube aliquoting feature is planned for FY22.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influence of Reservoir Convection on Heat Extraction with Closed-Loop Geothermal Systems

Over the past few years, advancements in closed-loop geothermal systems (CLGS), also called advanced geothermal systems (AGS), have sparked a renewed interest in these types of designs. CLGS have certain advantages over traditional and enhanced geothermal systems (EGS), including not requiring in-situ reservoir permeability, conservation of the circulating fluid, and allowing for different fluids, including working fluids directly driving a turbine at the surface. CLGS may be attractive in environments where water resources are limited, rock contaminants must be avoided, and stimulation treatments are not available (e.g., due to regulatory or technical reasons). Despite these advantages, CLGS have some challenges, including limited surface area for heat transfer and requiring long wellbores and laterals to obtain multi-MW output in conduction-only reservoirs. CLGS have been investigated in conduction-only systems. In this paper, we explore the impact of both forced and natural convection on the levels of heat extraction with a CLGS deployed in a hot wet rock reservoir. We bound potential benefits of convection by investigating liquid reservoirs over a range of natural and forced convective coefficients. Additionally, we investigate the effects of permeability, porosity, and geothermal temperature gradient in the reservoir on CLGS outputs. Reservoir simulations indicate that reservoir permeabilities of at least ~100 mD are required for natural convection to increase the heat output with respect to a conduction-only scenario. The impact increases with increasing reservoir temperature. When subject to a forced convection flow field, Darcy velocities of at least 10-7 m/s are required to obtain an increase in heat output.

advanced geothermal systems↗

Demonstration of an All-Refractory Corrosion-Resistant Molten Salt Pumping and Storage Infrastructure Up to 950 degrees C

Concentrating solar power (CSP) with thermal energy storage (TES) has an estimated cost similar to solar photovoltaics (PV) with lithium-ion batteries (LIB), but CSP + TES has the potential for significantly reduced cost by operating above 700 degrees C. However, this requires a TES medium and containment infrastructure which are chemically compatible and do not degrade above 700 degrees C. MgCl2-KCl-NaCl (MKN) salt is a promising medium, but when MKN salt has small amounts of water and oxygen dissolved in it, it excessively corrodes conventional commercial alloys. Here, we consider refractory materials including graphite, carbon-carbon composite (C/C), and molybdenum because they maintain high mechanical strength at elevated temperatures and are expected to resist corrosion by MKN salt. While selection of refractory materials is often constrained by the need to remain chemically stable in air, this work uses an enclosure filled with inert gas to allow the use of materials like graphite and molybdenum. Notably, graphite components can seal against liquids unlike many brittle refractory materials. We demonstrate a centrifugal pump and mechanical seals made of refractory materials in a laboratory-scale circulation loop, which successfully operated continuously for more than 49 h at temperatures ranging from 750 degrees C to 950 degrees C with no mechanical failures or chemical degradation of the refractory materials. To the best of our knowledge, this is the highest temperature molten salt circulation loop that has been successfully developed, and this refractory infrastructure allows for operation at even much higher temperatures (<1600 degrees C) if a storage medium with a lower vapor pressure is used. The principles of this architecture are relevant to other applications with high temperature flowing metals and salts including Generation IV nuclear fission reactors for power production and molten salt electrolysis reactors for metallurgical processing.

14 SOLAR ENERGY↗

Segmented Energy Routing for a Modular AC/DC Hybrid System

This article presents a modular ac/dc system with both distributed and centralized power ports for energy router (ER) applications. In each module of the described system, photovoltaic (PV) power generation units, battery-type energy storage (ES) units, and critical loads are connected to the cascaded H-bridge (CHB)-organized medium-voltage (MV) dc links, with fully distributed low-voltage (LV) dc power ports. Copies of modules share the centralized load bus and interact with an MV ac grid in parallel. Hybrid power port (HPO) assigns flexibility to the system but makes energy routings a necessity for stable operation. In this article, a segmented energy management strategy for the HPO-ER is proposed. In terms of the grid-side power transferring, the system ratings are intentionally designed to match significant power imbalance. Focally, a segmented energy management strategy is proposed to realize fully autonomous energy routing involving MV ac grid, distributed PV generations, distributed battery storages, and LV load. The system is proven to be stable using the derived impedance-based model considering the interaction between power blocks. The feasibility of the topology and control strategy is also verified through software simulation, laboratorial hardware prototype experiment, and hardware-in-the-loop (HIL) emulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

HTGR Multiphysics Application Drivers FY26 Updates

This report summarizes FY26 progress under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program's high-temperature gas-cooled reactor (HTGR) application driver work, covering a wide range of activities such as code validation and multi-physics code assessment. 1) A detailed SAM model of the High-Temperature Engineering Test Reactor (HTTR) was developed using a unique-block grouping approach, with an extended parallel thermal network method to capture block-to-block conduction and radiation heat transfer, and applied to steady-state simulations of the HTTR 30~MW and 9~MW cases. 2) In another activity, SAM's newly implemented multi-component gas flow model was validated against the Natural convection Shutdown heat removal Test Facility (NSTF) argon ingress experiment, correctly capturing the density-driven suppression and thermal recovery of natural circulation observed when argon is introduced into the air-cooled Reactor Cavity Cooling System (RCCS) loop. 3) For the OECD/NEA High Temperature Test Facility (HTTF) benchmark, we co-led the international benchmark activities as well as the OECD/NEA final benchmark report to be released at the end of this year. 4) Finally, the coupled Griffin-SAM modeling capability for pebble-bed HTGRs was advanced by verifying the Griffin neutronics solution against Serpent Monte Carlo for a realistic non-uniform temperature distribution, resolving several deficiencies in the SAM-to-Griffin temperature transfer scheme, and enabling distinct fuel kernel, moderator, and coolant temperatures for cross section feedback. These new features were demonstrated in a PBR load-following transient.

Lee, Alvin↗

The development of a microprocessor-controlled linearly-actuated valve assembly

The development of a proportional fluid control valve assembly is presented. This electromechanical system is needed for space applications to replace the current proportional flow controllers. The flow is controlled by a microprocessor system that monitors the control parameters of upstream pressure and requested volumetric flow rate. The microprocessor achieves the proper valve stem displacement by means of a digital linear actuator. A linear displacement sensor is used to measure the valve stem position. This displacement is monitored by the microprocessor system as a feedback signal to close the control loop. With an upstream pressure between 15 and 47 psig, the developed system operates between 779 standard CU cm/sec (SCCS) and 1543 SCCS.

Wall, R. H.↗

Field Study and Energy-Plus Benchmarks for Energy Saver Homes having Different Envelope Designs

An alliance to maximize energy efficiency and cost-effective residential construction (ZEBRAlliance) built and field tested four homes that are 50 percent more energy efficient than a code compliant home. The homes are unoccupied for the duration of a two-year field study, thereby eliminating the confounding issue of occupancy habits. All homes have about the same consistent and scheduled internal load. Each home showcases a unique envelope strategy: 1) structural insulated panel (SIP), 2) optimal value wall framing (OVF), 3) advanced framing featuring the benefits of insulations mixed with phase change materials (PCM), and 4) an exterior insulation and finish system (EIFS). All homes have different weather resistive barriers (WRBs) and/or air barriers to limit air and moisture infiltration. Three homes provide space conditioning and water heating via a ground loop heat exchanger, while the fourth home uses a high efficiency air-to-air heat pump and heat pump water heater. Field performance and results of EnergyPlus V7.0 benchmarks were made for roof and attics as compared to cathedral design and for wall heat flows to validate models. The moisture content of the wall sheathing is shown to prove the protecting effectiveness of WRBs. Temperature distributions through insulations in the wall and ceiling with and without PCMs are described to characterize the performance of the PCM building envelopes.

Attic↗

System for the highly autonomous operation of a modular liquid-metal reactor with steam cycle

The invention relates to a nuclear plant in which the power of a nuclear reactor is controlled via demand of a connected electric grid. A naturally circulating nuclear reactor coolant loop is linked to a water/steam loop by means of a steam generator. The water/steam loop consists of an electric power generating unit and a water recirculating and steam control system. The generator is coupled to an external power grid. As power requirements of the grid change, a controller linked to the generator and a three way valve divides steam flow between the expansion turbine and a feedwater heater to boost or retard the power output. Altering the steam flow changes the pressure and temperature in the water/steam system and thus the coolant flow rate. The change in coolant flow allows the reactor core to regulate its reactivity to reach a state of equilibrium to the demand for electric power.

Vilim, Richard B.↗

Evaluation of the energy balance of chemical looping combustion of solid fuels using CuO-based oxygen carriers

Chemical looping combustion (CLC) can inherently capture the CO2 generated during thermal energy production. When using CuO-based oxygen carriers, the reactions in both the fuel reactor (FR) and air reactor (AR) are exothermic, facilitating autothermal operation. To prevent the oxygen carrier from becoming agglomerated while ensuring a sufficient oxygen release rate, it is necessary to predict the FR temperature and remove an appropriate amount of heat from the AR when burning high-rank fuels. Here in this work, the energy balance of a CuO-based CLC system firing various solid fuels (biomass, coal, and petroleum coke) was investigated by establishing a thermodynamic model using FactSage. The energy distribution characteristics of the FR were quantified based on a virtual five-step thermodynamic sequence. The effects of fuel properties, oxygen carrier properties, and operating conditions on the energy balance were evaluated systematically. The results indicate that the temperature difference between the FR and AR is not very sensitive to the heating value of the fuel, while the CuO loading of the oxygen carrier, the heat capacity of the support material, and the flow rate of the fluidizing gas have significant impact. The insights obtained in this work will help improve the design and heat management of CLC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Digital twin framework for PIP-II linac: AI-driven multi-scale modeling from ion source to 800 MeV

The PIP-II superconducting linac at Fermilab is designed to deliver multi-megawatt proton beams for neutrino physics and other high-intensity applications. To expedite commissioning and enhance operational reliability, we have developed an EPICS-based data flow framework that seamlessly integrates digital twins (DT) with physical twins (PT). These digital twins comprise high-fidelity beam dynamics models or data-driven surrogate models connected to their physical counterparts through real-time diagnostics and advanced machine-learning algorithms.Central to this framework is Linac_Gen, an accelerated simulation tool that incorporates convolutional neural networks, random forests, and genetic algorithms to provide up to a tenfold speedup in optimizing the accelerator geometry model. An EPICS translator layer ensures interoperability by efficiently mapping lattice parameters across diverse simulation platforms.Our EPICS-based framework supports multiple operational modes—monitoring, passive learning, closed-loop control, and online learning—covering the entire machine lifecycle. By leveraging HPC resources and multi-objective optimization techniques, the digital twin enables adaptive trajectory correction, real-time fault detection, and predictive modeling of beam stability. This comprehensive approach paves the way for robust, high-intensity operation and data-driven accelerator R&D at Fermilab.

Pathak, Abhishek [Fermilab]↗