Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ELECTROMAGNETIC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Electromagnetic momentum conservation in media

That static electric and magnetic fields can store momentum may be perplexing, but is necessary to ensure total conservation of momentum. Simple situations in which such field momentum is transferred to nearby bodies and point charges have often been considered for pedagogical purposes, normally assuming vacuum surroundings. If dielectric media are involved, however, the analysis becomes more delicate, not least since one encounters the electromagnetic energy-momentum problem in matter, the 'Abraham-Minkowski enigma', of what the momentum is of a photon in matter. We analyze the momentum balance in three nontrivial examples obeying azimuthal symmetry, showing how the momentum conservation is satisfied as the magnetic field decays and momentum is transferred to bodies present. In the last of the examples, that of point charge outside a dielectric sphere in an infinite magnetic field, we find that not all of the field momentum is transferred to the nearby bodies; a part of the momentum appears to vanish as momentum flux towards infinity. We discuss this and other surprising observations which can be attributed to the assumption of magnetic fields of infinite extent. We emphasize how formal arguments of conserved quantities cannot determine which energy-momentum tensor is more 'correct', and each of our conservation checks may be performed equally well in the Minkowski or Abraham framework.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulsed electromagnetic field induces Ca2+-dependent osteoblastogenesis in C3H10T1/2 mesenchymal cells through the Wnt-Ca2+/Wnt-β-catenin signaling pathway

Highlights: • C3H10T1/2 cell proliferation can be greatly promoted by PEMF exposure. • C3H10T1/2 cell differentiation into osteoblast can be induced upon the stimulation of PEMF. • Intracellular [Ca2+]i up-regulation was observed during the process of PEMF-induced C3H10T1/2 cell differentiation. • PEMF-induced C3H10T1/2 cell differentiation was Ca2+-dependent. • PEMF-induced [Ca2+]i elevation suggested a combination of Wnt/Ca2+ and Wnt/β-catenin signaling pathways. Pulsed electromagnetic fields (PEMFs) are effective in healing fractures and improving osteoporosis. However, their effect on mesenchymal cells remains largely unknown. In this study, the effects of PEMF on osteoblastogenesis and its underlying molecular signaling mechanisms were systematically investigated in C3H10T1/2 cells. C3H10T1/2 mesenchymal cells were exposed to 30-Hz PEMF bursts at various intensities for 3 consecutive days. The optimal PEMF exposure (30 Hz, 1 mT, 2 h/day) was applied in subsequent experiments. Our results suggest that intracellular [Ca{sup 2+}]i in C3H10T1/2 cells can be upregulated upon exposure to PEMF and that PEMF-induced C3H10T1/2 cell differentiation was Ca{sup 2+}-dependent. The pro-osteogenic effect of PEMF on Ca{sup 2+}-dependent osteoblast differentiation was then verified by alkaline phosphatase (ALP) and von Kossa staining. Furthermore, PEMF promoted the gene expression and protein synthesis of the Wnt/β-catenin pathway. Increased [Ca{sup 2+}]i in the nucleoplasm was followed by the mobilization and translocation of β-catenin into the nucleus in C3H10T1/2 cells. A model of Wnt/β-catenin signaling and the Wnt/Ca2+ signaling network is proposed. Taken together, these findings indicated for the first time that PEMF induces osteoblastogenesis through increased intracellular [Ca{sup 2+}]i and the Wnt-Ca2+/Wnt-β-catenin signaling pathway in C3H10T1/2 mesenchymal cells.

60 APPLIED LIFE SCIENCES↗

Joint inversion of electromagnetic measurements for the determination of water saturation profiles in concrete structures

Highlights: • DC-electrical and dielectric data are combined to estimate concrete saturation degree. • A joint inversion approach of the electromagnetic measurements is proposed. • The sensitivity of the measurements to the saturation model parameters is analysed. • The new joint approach was developed and is applied to synthetic and real data. • The benefits of the joint approach over the inversion of one data type are highlighted. Water saturation profiles in concrete are essential to assess its durability and can be determined using non-destructive techniques, especially the electric and the capacitive methods. In this paper, we propose a new inversion scheme where both resistivity and permittivity measurements are inverted jointly to retrieve the saturation profile. The finite element method is used to model the measurements in 3D, the concrete having a saturation profile with depth, represented by a continuous model taking the form of a Weibull curve with four parameters. A non-linear least-squares optimization based on the Levenberg-Marquardt scheme is developed for the inversion of measurements. Results show that information gathered from both measurements enriches the reconstructed profile, leading to a more reliable estimation of saturation profiles. We believe that the joint inversion method herein developed could lead to the study of more complex phenomena, such as the coupled water-chloride ingress.

36 MATERIALS SCIENCE↗

Formulation and numerical analysis of a fully-coupled dynamically deforming electromagnetic wire

Here, an electromagnetic beam model is developed for the simulation of actuated electronic textiles. The beam is solved using a nonlinear director-based kinematic description with additional temperature and electric potential fields along its length. The three fields are fully coupled by mutual dependences on the deformation, Lorenz force, back electromotive force, temperature dependent constitutive responses, and the Seebeck effect. Instead of solving Maxwell's equations in full detail, a quasistatic approximation is used to solve the electric potential in the presence of a moving material medium. The current-carrying beam approximation is used to further simplify the solution space for the potential. While this formulation alleviates the spatial and temporal discretization restrictions, the coupled problem is an index-1 semi-explicit Differential Algebraic Equation requiring special treatment. The time dependent problem is solved using different Runge-Kutta methods. Diagonally implicit Runge-Kutta methods and explicit Runge-Kutta methods using implicit solution of the electric potential problem are explored. The finite element model is implemented using the open source package FEniCS, which is able to automatically generate the linearizations of the multiphysics equations required for the implicit solutions. A model problem is constructed with which to test and analyze the physical formulation and numerical solution techniques. The time stepping methods are verified using the convergence orders of the higher-order Runge-Kutta methods. Runtime comparisons show that the explicit methods are generally more computationally efficient than the implicit schemes used for this problem. For the implicit schemes, a staggered solution is significantly faster than a monolithic solution at most time step sizes. However, at very large time steps, such as those that would be used for dynamic relaxation, the monolithic solution can be more efficient than the staggered solution.

36 MATERIALS SCIENCE↗

Orb5: A global electromagnetic gyrokinetic code using the PIC approach in toroidal geometry

This paper presents the current state of the global gyrokinetic code Orb5 as an update of the previous reference [Jolliet et al., Comp. Phys. Commun. 177 409 (2007)]. The Orb5 code solves the electromagnetic VlasovMaxwell system of equations using a PIC scheme and also includes collisions and strong flows. The code assumes multiple gyrokinetic ion species at all wavelengths for the polarization density and drift-kinetic electrons. Variants of the physical model can be selected for electrons such as assuming an adiabatic response or a “hybrid” model in which passing electrons are assumed adiabatic and trapped electrons are drift-kinetic. A Fourier filter as well as various control variates and noise reduction techniques enable simulations with good signal-to-noise ratios at a limited numerical cost. They are completed with different momentum and zonal flow-conserving heat sources allowing for temperature-gradient and flux-driven simulations. The code, which runs on both CPUs and GPUs, is well benchmarked against other similar codes and analytical predictions, and shows good scalability up to thousands of nodes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EZ: An efficient, charge conserving current deposition algorithm for electromagnetic particle-in-cell simulations

Here, we present EZ, a novel current deposition algorithm for particle-in-cell (PIC) simulations. EZ calculates the current density on the electromagnetic grid due to macro-particle motion within a time step by solving the continuity equation of electrodynamics. Being a charge conserving hybridization of Esirkepov's method and ZigZag, we refer to it as “EZ” as shorthand for “Esirkepov meets ZigZag”. Simulations of a warm, relativistic plasma with PIConGPU show that EZ achieves the same level of charge conservation as the commonly used method by Esirkepov, yet reaches higher performance for macro-particle assignment-functions up to third-order. In addition to a detailed description of the functioning of EZ, reasons for the expected and observed performance increase are given, and guidelines for its implementation aiming at highest performance on GPUs are provided.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An unstructured body-of-revolution electromagnetic particle-in-cell algorithm with radial perfectly matched layers and dual polarizations

A novel electromagnetic particle-in-cell algorithm has been developed for fully kinetic plasma simulations on unstructured (irregular) meshes in complex body-of-revolution geometries. The algorithm, implemented in the BORPIC++ code, utilizes a set of field scalings and a coordinate mapping, reducing the Maxwell field problem in a cylindrical system to a Cartesian finite element Maxwell solver in the meridian plane. The latter obviates the cylindrical coordinate singularity in the symmetry axis. The choice of an unstructured finite element discretization enhances the geometrical flexibility of the BORPIC++ solver compared to the more traditional finite difference solvers. Symmetries in Maxwell’s equations are explored to decompose the problem into two dual polarization states with isomorphic representations that enable code reuse. The particle-in-cell scatter and gather steps preserve charge conservation at the discrete level. Our previous algorithm (BORPIC+) discretized the E and B field components of TE Φ and TM Φ polarizations on the finite element (primal) mesh. Here, we employ a new field-update scheme. Using the same finite element (primal) mesh, this scheme advances two sets of field components independently: (1) E and B of TE Φ polarized fields, (E z , E ρ , B Φ ) and (2) D and H of TM Φ polarized fields, (D Φ , H z , H ρ ). Since these field updates are not explicitly coupled, the new field solver obviates the coordinate singularity, which otherwise arises at the cylindrical symmetric axis, ρ = 0 when defining the discrete Hodge matrices (generalized finite element mass matrices). Here, a cylindrical perfectly matched layer is implemented as a boundary condition in the radial direction to simulate open space problems, with periodic boundary conditions in the axial direction. We investigate effects of charged particles moving next to the cylindrical perfectly matched layer. We model azimuthal currents arising from rotational motion of charged rings, which produce TMΦ polarized fields. Several numerical examples are provided to illustrate the first application of the algorithm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization using pathwise algorithmic derivatives of electromagnetic shower simulations

Among the well-known methods to approximate derivatives of expectancies computed by Monte-Carlo simulations, averages of pathwise derivatives are often the easiest one to apply. Computing them via algorithmic differentiation typically does not require major manual analysis and rewriting of the code, even for very complex programs like simulations of particle-detector interactions in high-energy physics. However, the pathwise derivative estimator can be biased if there are discontinuities in the program, which may diminish its value for applications. This work integrates algorithmic differentiation into the electromagnetic shower simulation code HepEmShow based on G4HepEm, allowing us to study how well pathwise derivatives approximate derivatives of energy depositions in a sampling calorimeter with respect to parameters of the beam and geometry. We found that when multiple scattering is disabled in the simulation, means of pathwise derivatives converge quickly to their expected values, and these are close to the actual derivatives of the energy deposition. Additionally, we demonstrate the applicability of this novel gradient estimator for stochastic gradient-based optimization in a model example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Outdoor characterization of radio frequency electromagnetic fields in a Spanish birth cohort

There is considerable public concern in many countries about the possible adverse effects of exposure to non-ionizing radiation electromagnetic fields, especially in vulnerable populations such as children. The aim of this study was to characterize environmental exposure profiles within the frequency range 100 kHz–6 GHz in the immediate surrounds of the dwellings of 123 families from the INMA-Granada birth cohort in Southern Spain, using spot measurements. The arithmetic mean root mean-square electric field (E{sub RMS}) and power density (S{sub RMS}) values were, respectively, 195.79 mV/m (42.3% of data were above this mean) and 799.01 µW/m{sup 2} (30% of values were above this mean); median values were 148.80 mV/m and 285.94 µW/m{sup 2}, respectively. Exposure levels below the quantification limit were assigned a value of 0.01 V/m. Incident field strength levels varied widely among different areas or towns/villages, demonstrating spatial variability in the distribution of exposure values related to the surface area population size and also among seasons. Although recorded values were well below International Commission for Non-Ionizing Radiation Protection reference levels, there is a particular need to characterize incident field strength levels in vulnerable populations (e.g., children) because of their chronic and ever-increasing exposure. The effects of incident field strength have not been fully elucidated; however, it may be appropriate to apply the precautionary principle in order to reduce exposure in susceptible groups. - Highlights: • Spot measurements were performed in the immediate surrounds of children's dwellings. • Mean root mean-square electric field and power density values were calculated. • Most recorded values were far below international standard guideline limits. • Data demonstrate spatial variability in the distribution of exposure levels. • While adverse effects are proven, application of the precautionary principle may be appropriate.

54 ENVIRONMENTAL SCIENCES↗

Modeling of Inductive Constant Power Load for Electromagnetic-Transient Simulations-Part II

This paper improves the dynamic constant power (CP) load model that was published in Part I, which is appropriate for electromagnetic-transient (EMT). The improved model conserves all features of its predecessor. For instance, it maintains a fixed power consumption (both active and reactive parts) and a fixed power factor for loads that are predominantly inductive. Furthermore, as the proposed model is a time-dependent system, it is applicable to both sinusoidal and non-sinusoidal case studies. However, the previous model cannot be easily integrated with numeric solvers because it simulated load data over one cycle all together, not sequentially in a time-step manner, due to the limitation involved with the power factor. The improved version, on the contrary, allows the load to be simulated at every time step, which would facilitate its integration with numeric solvers. The model's validity is confirmed by comparing its response with data that is synthesized from constant impedance load, and the result is satisfactory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electromagnetic Transponders Indicate Prostate Size Increase Followed by Decrease During the Course of External Beam Radiation Therapy

Purpose: Real-time image guidance enables more accurate radiation therapy by tracking target movement. This study used transponder positions to monitor changes in prostate volume that may be a source of dosimetric and target inaccuracy. Methods and Materials: Twenty-four men with biopsy-proven T1c-T3a prostate cancer each had three electromagnetic transponders implanted transperineally. Their coordinates were recorded by the Calypso system, and the perimeter of the triangle formed by the transponders was used to calculate prostate volumes at sequential time points throughout the course of radiation therapy to a dose of 81 Gy in 1.8-Gy fractions. Results: There was a significant decrease in mean prostate volume of 10.9% from the first to the final day of radiation therapy. The volume loss did not occur monotonically but increased in most patients (75%) during the first several weeks to a median maximum on Day 7. The volume increased by a mean of 6.1% before decreasing by a mean maximum difference of 18.4% to nadir (p < 0.001 for both increase and decrease). Glandular shrinkage was asymmetric, with the apex to right base dimension varying more than twice that of the lateral dimension. For all dimensions, the mean change was <0.5 cm. Conclusion: Real-time transponder positions indicated a volume increase during the initial days of radiation therapy and then significant and asymmetric shrinkage by the final day. Understanding and tracking volume fluctuations of the prostate during radiation therapy can help real-time imaging technology perform to its fullest potential.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electromagnetic Real-Time Tumor Position Monitoring and Dynamic Multileaf Collimator Tracking Using a Siemens 160 MLC: Geometric and Dosimetric Accuracy of an Integrated System

Purpose: Dynamic multileaf collimator tracking represents a promising method for high-precision radiotherapy to moving tumors. In the present study, we report on the integration of electromagnetic real-time tumor position monitoring into a multileaf collimator-based tracking system. Methods and Materials: The integrated system was characterized in terms of its geometric and radiologic accuracy. The former was assessed from portal images acquired during radiation delivery to a phantom in tracking mode. The tracking errors were calculated from the positions of the tracking field and of the phantom as extracted from the portal images. Radiologic accuracy was evaluated from film dosimetry performed for conformal and intensity-modulated radiotherapy applied to different phantoms moving on sinusoidal trajectories. A static radiation delivery to the nonmoving target served as a reference for the delivery to the moving phantom with and without tracking applied. Results: Submillimeter tracking accuracy was observed for two-dimensional target motion despite the relatively large system latency of 500 ms. Film dosimetry yielded almost complete recovery of a circular dose distribution with tracking in two dimensions applied: 2%/2 mm gamma-failure rates could be reduced from 59.7% to 3.3%. For single-beam intensity-modulated radiotherapy delivery, accuracy was limited by the finite leaf width. A 2%/2 mm gamma-failure rate of 15.6% remained with tracking applied. Conclusion: The integrated system we have presented marks a major step toward the clinical implementation of high-precision dynamic multileaf collimator tracking. However, several challenges such as irregular motion traces or a thorough quality assurance still need to be addressed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electromagnetic Detection and Real-Time DMLC Adaptation to Target Rotation During Radiotherapy

Purpose: Intrafraction rotation of more than 45 Degree-Sign and 25 Degree-Sign has been observed for lung and prostate tumors, respectively. Such rotation is not routinely adapted to during current radiotherapy, which may compromise tumor dose coverage. The aim of the study was to investigate the geometric and dosimetric performance of an electromagnetically guided real-time dynamic multileaf collimator (DMLC) tracking system to adapt to intrafractional tumor rotation. Materials/Methods: Target rotation was provided by changing the treatment couch angle. The target rotation was measured by a research Calypso system integrated with a real-time DMLC tracking system employed on a Varian linac. The geometric beam-target rotational alignment difference was measured using electronic portal images. The dosimetric accuracy was quantified using a two-dimensional ion chamber array. For each beam, the following five delivery modes were tested: 1) nonrotated target (reference); 2) fixed rotated target with tracking; 3) fixed rotated target without tracking; 4) actively rotating target with tracking; and 5) actively rotating target without tracking. Dosimetric performance of the latter four modes was measured and compared to the reference dose distribution using a 3 mm/3% {gamma}-test. Results: Geometrically, the beam-target rotational alignment difference was 0.3 Degree-Sign {+-} 0.6 Degree-Sign for fixed rotation and 0.3 Degree-Sign {+-} 1.3 Degree-Sign for active rotation. Dosimetrically, the average failure rate for the {gamma}-test for a fixed rotated target was 11% with tracking and 36% without tracking. The average failure rate for an actively rotating target was 9% with tracking and 35% without tracking. Conclusions: For the first time, real-time target rotation has been accurately detected and adapted to during radiation delivery via DMLC tracking. The beam-target rotational alignment difference was mostly within 1 Degree-Sign . Dose distributions to fixed and actively rotating targets with DMLC tracking were significantly superior to those without tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adaptive Radiation Therapy for Postprostatectomy Patients Using Real-Time Electromagnetic Target Motion Tracking During External Beam Radiation Therapy

Purpose: Using real-time electromagnetic (EM) transponder tracking data recorded by the Calypso 4D Localization System, we report inter- and intrafractional target motion of the prostate bed, describe a strategy to evaluate treatment adequacy in postprostatectomy patients receiving intensity modulated radiation therapy (IMRT), and propose an adaptive workflow. Methods and Materials: Tracking data recorded by Calypso EM transponders was analyzed for postprostatectomy patients that underwent step-and-shoot IMRT. Rigid target motion parameters during beam delivery were calculated from recorded transponder positions in 16 patients with rigid transponder geometry. The delivered doses to the clinical target volume (CTV) were estimated from the planned dose matrix and the target motion for the first 3, 5, 10, and all fractions. Treatment adequacy was determined by comparing the delivered minimum dose (D{sub min}) with the planned D{sub min} to the CTV. Treatments were considered adequate if the delivered CTV D{sub min} is at least 95% of the planned CTV D{sub min}. Results: Translational target motion was minimal for all 16 patients (mean: 0.02 cm; range: −0.12 cm to 0.07 cm). Rotational motion was patient-specific, and maximum pitch, yaw, and roll were 12.2, 4.1, and 10.5°, respectively. We observed inadequate treatments in 5 patients. In these treatments, we observed greater target rotations along with large distances between the CTV centroid and transponder centroid. The treatment adequacy from the initial 10 fractions successfully predicted the overall adequacy in 4 of 5 inadequate treatments and 10 of 11 adequate treatments. Conclusion: Target rotational motion could cause underdosage to partial volume of the postprostatectomy targets. Our adaptive treatment strategy is applicable to post-prostatectomy patients receiving IMRT to evaluate and improve radiation therapy delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory-Induced Prostate Motion Using Wavelet Decomposition of the Real-Time Electromagnetic Tracking Signal

Purpose: The objective of this work is to characterize and quantify the impact of respiratory-induced prostate motion. Methods and Materials: Real-time intrafraction motion is observed with the Calypso 4-dimensional nonradioactive electromagnetic tracking system (Calypso Medical Technologies, Inc. Seattle, Washington). We report the results from a total of 1024 fractions from 31 prostate cancer patients. Wavelet transform was used to decompose the signal to extract and isolate the respiratory-induced prostate motion from the total prostate displacement. Results: Our results show that the average respiratory motion larger than 0.5 mm can be observed in 68% of the fractions. Fewer than 1% of the patients showed average respiratory motion of less than 0.2 mm, whereas 99% of the patients showed average respiratory-induced motion ranging between 0.2 and 2 mm. The maximum respiratory range of motion of 3 mm or greater was seen in only 25% of the fractions. In addition, about 2% patients showed anxiety, indicated by a breathing frequency above 24 times per minute. Conclusions: Prostate motion is influenced by respiration in most fractions. Real-time intrafraction data are sensitive enough to measure the impact of respiration by use of wavelet decomposition methods. Although the average respiratory amplitude observed in this study is small, this technique provides a tool that can be useful if one moves to smaller treatment margins (≤5 mm). This also opens ups the possibility of being able to develop patient specific margins, knowing that prostate motion is not unpredictable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Prospective Cohort Study of Gated Stereotactic Liver Radiation Therapy Using Continuous Internal Electromagnetic Motion Monitoring

Intrafraction motion can compromise the treatment accuracy in liver stereotactic body radiation therapy (SBRT). Respiratory gating can improve treatment delivery; however, gating based on external motion surrogates is inaccurate. The present study reports the use of Calypso-based internal electromagnetic motion monitoring for gated liver SBRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulating the effects of warm O + ions on the growth of electromagnetic ion cyclotron (EMIC) waves

Electromagnetic ion cyclotron (EMIC) waves are believed to play a crucial role in the dynamics of the Earth’s magnetosphere. It has been widely accepted that plasma compositions can influence the growth rate of EMIC waves in the inner magnetosphere, but how warm O + ions change the wave growth rate is not well known. In this study, we investigate the impact of ring current O + concentration on the EMIC growth rate during a specific storm when the O + ion flux significantly increases. We calculate the growth rate of EMIC waves by using physics-based ion distributions output from the Ring current–Atmosphere interactions Model with Self-Consistent magnetic (B) and Electric (E) fields (RAM-SCBE) model. The percentage of warm O + is parametrically varied to examine how the maximum EMIC growth rate changes over time and how the global distribution of the maximum EMIC growth rate is affected. We found that the maximum growth rate of H-band appears in the dusk-to-midnight sector near the plasmapause, while O-band is excited at a slightly outer region. The maximum growth rate of He-band is closely related to the cold plasma density. With the increase of warm O + density, the maximum growth rate of H-band and He-band EMIC wave is reduced, while that of O-band EMIC wave is increased, and the region with this wave excitation is widened. Furthermore, such variation in the maximum EMIC growth rate implies a potential impact on the associated wave–particle interactions and change of the decay rate in the ring current.

79 ASTRONOMY AND ASTROPHYSICS↗