Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

Novel calibration system with sparse wires for CMB polarization receivers

B-modes in the cosmic microwave background (CMB) polarization is a smoking gun signature of the inflationary universe. To achieve better sensitivity to this faint signal, CMB polarization experiments aim to maximize the number of detector elements, resulting in a large focal plane receiver. Detector calibration of the polarization response becomes essential. It is extremely useful to be able to calibrate 'simultaneously' all detectors on the large focal plane. We developed a novel calibration system that rotates a large 'sparse' grid of metal wires, in front of and fully covering the field of view of the focal plane receiver. Polarized radiation is created via the reflection of ambient temperature from the wire surface. Since the detector has a finite beam size, the observed signal is smeared according to the beam property. The resulting smeared polarized radiation has a reasonable intensity (a few Kelvin or less) compared to the sky temperature ({approx}10 K observing condition). The system played a successful role for receiver calibration of QUIET, a CMB polarization experiment located in the Atacama desert in Chile. The successful performance revealed that this system is applicable to other experiments based on different technologies, e.g. TES bolometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new neutron time-of-flight detector for yield and ion-temperature measurements in DT implosions on OMEGA

A new neutron time-of-flight (nTOF) detector for yield and ion-temperature measurements in deuterium–tritium (DT) implosions was designed, installed, and calibrated on the OMEGA Laser System. This detector was installed at θ = 46.8° from the vertical and φ = 84.9°, previously a region without other detectors, in order to decrease the uncertainty of low-mode asymmetry measurements by six other nTOF detectors. The new nTOF detector uses the “PMT only” concept [Glebov et al., Rev. Sci. Instrum. 92, 013509 (2021)] and consists of a Photek photomultiplier tube (PMT)-110 in a thin aluminum housing. There is no lead shielding in front of the PMT to allow measurements of the x-ray instrument response function of the detector. The detector is installed in the OMEGA H2-port line of sight at 9.3 m from the target chamber center in the OMEGA Target Bay and is called the H2 nTOF detector. The H2 nTOF measures DT yields in the 1 × 10 13 to 3 × 10 14 range and ion temperatures from 2 to 12 keV. H2 nTOF reduced the hotspot flow uncertainty in the z-direction from ±10 to ±8 km/s, and the uncertainty in the anisotropic flow axis from σ θ = ±26° to ±13° and σ φ = ±25° to ±21°. Here, the design details, performance, and calibration results of the H2 nTOF detector in DT implosions on OMEGA will be presented.

Laser fusion↗

Smoke and particle detector using tritiated semiconductor foil

A smoke and particle ionization detector using tritiated amorphous silicon film as the radiation source is demonstrated. The ion chamber design includes both bipolar and unipolar region; the unipolar region is defined as the volume space extending beyond the range of ionizing particles. Attachment of ions to particulate matter in the unipolar region considerably reduces the mobility of the carriers, thus forming a space charge cloud accompanied by a reduction in the electrical field strength, thereby enhancing the particulate detection responsivity. Tritium {beta}s have a maximum range of about 6 mm in air, which makes the detector compact. Owing to the potential of increased specific activity, it results in a gamma-free detector with improved sensitivity. The results show that this gamma-free detector is several-fold to forty-fold more responsive than traditional ionization detectors using Am-241. In addition, this ion chamber can function as a dual detector having both photoelectric and ionization detector responsivities. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Early Results From NOAA-21 (JPSS-2) VIIRS on-Orbit Calibration

Launched on November 10, 2022, the NOAA-21 (N-21) VIIRS has successfully completed its initial post-launch testing (PLT) and intensive calibration and validation (ICV) activities. It is now operated in its nominal configuration and characterized using measurements from its on-board calibrators (OBC) and lunar observations. In this paper, we provide a brief description of N-21 VIIRS on-orbit operation and calibration activities and present results derived from its early mission performance assessments, including examples of its OBC performance, spectral band responses, as well as detector signal to noise characteristics. As shown in this paper, the overall performance of N-21 VIIRS is better than that of its predecessor currently operated on the S-NPP and comparable to the one onboard the N-20, with an exception of relatively large changes in its SWIR band responses.

NOAA-21↗

Measurement of Neutron Reaction Cross Sections in Carbon using a Single Crystal Diamond Detector

A single crystal diamond detector was exposed to the quasi mono-energetic neutron fields in the energy range from 7 MeV to 20.5 MeV produced by the Van de Graaff neutron generator of the EC-JRC-IRMM. Pulse Height Spectra (PHS) of the neutron interaction with the diamond (carbon) were recorded in order to derive the experimental response function of this detector to neutrons in view of its use as a compact fast neutron spectrometer. Several peaks produced by outgoing charged particles produced when neutrons interact with carbon were identified using the reaction Q-values. The corresponding nuclear reactions, such as (n,{alpha}), (n,p), (n,d) for different excitation states were identified in the PHS. The analysis of the peaks allows the derivation of some neutron reaction cross sections in carbon. The results are presented in this paper together with the associated uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of ATS-5 data

Data from the particle detectors on ATS-5 in synchronous orbit and from the meridian line of magnetometers at a ground station are correlated for periods of well defined substorm activity. Specific substorm events are presented whose region of maximum perturbation can be accurately identified using current systems modelling techniques. It was found that the impulsive particle response at ATS-5 is correlated with changes in the auroral electrojet structure during the development of the substorm expansive phase. The response of the particle detectors appears to differ from event to event depending on the geometry of the disturbed region of the magnetosphere. It is concluded that the substorm disturbance typically begins at low latitude and propagates poleward in impulsive steps and that energetic electron enhancements are observed at ATS-5 when the poleward border of the electrojet intensifies in the latitude range of the ATS-5 field line.

Sharp, R. D.↗

Accurate Holdup Calculations with Predictive Modeling & Data Integration

In facilities that process special nuclear material (SNM) it is important to account accurately for the fissile material that enters and leaves the plant. Although there are many stages and processes through which materials must be traced and measured, the focus of this project is material that is “held-up” in equipment, pipes, and ducts during normal operation and that can accumulate over time into significant quantities. Accurately estimating the holdup is essential for proper SNM accounting (vis-à-vis nuclear non-proliferation), criticality and radiation safety, waste management, and efficient plant operation. Usually it is not possible to directly measure the holdup quantity and location, so these must be inferred from measured radiation fields, primarily gamma and less frequently neutrons. Current methods to quantify holdup, i.e. Generalized Geometry Holdup (GGH), primarily rely on simple source configurations and crude radiation transport models aided by ad hoc correction factors. This project seeks an alternate method of performing measurement-based holdup calculations using a predictive model that employs state-of-the-art radiation transport codes capable of accurately simulating such situations. Inverse and data assimilation methods use the forward transport model to search for a source configuration that best matches the measured data and simultaneously provide an estimate of the level of confidence in the correctness of such configuration. In this work the holdup problem is re-interpreted as an inverse problem that is under-determined, hence may permit multiple solutions. A probabilistic approach is applied to solving the resulting inverse problem. This approach rates possible solutions according to their plausibility given the measurements and initial information. This is accomplished through the use of Bayes’ Theorem that resolves the issue of multiple solutions by giving an estimate of the probability of observing each possible solution. To use Bayes’ Theorem, one must have a model y(x) that maps the state variables x (the solution in this case) to the measurements y. In this case, the unknown state variables are the configuration and composition of the heldup SNM. The measurements are the detector readings. Thus, the natural model is neutral-particle radiation transport where a wealth of computational tools exists for performing these simulations accurately and efficiently. The combination of predictive model and Bayesian inference forms the Data Integration with Modeled Predictions (DIMP) method that serves as foundation for this project. The cost functional describing the model-to-data misfit is computed via a norm created by the inverse of the covariance matrix of the model parameters and responses. Since the model y(x) for the holdup problem is nonlinear, a nonlinear optimization on Q is conducted via Newton-type iterative methods to find the optimal values of the model parameters x. This project comprised a collaboration between NC State University (NCSU), the University of South Carolina (USC), and Oak Ridge National Laboratory (ORNL). The project was originally proposed in seven main tasks with an eighth contingency task to be performed if time and funding permitted; in fact time did not permit commencement of the contingency task and it was not performed. The remaining tasks involved holdup analysis with gamma detection strategies and separately with neutrons based on coincidence counting. Early in the project, and upon consultation with experts in coincidence counting it became evident that this approach is not viable for holdup applications and this task was replaced with an alternative, but valuable investigation that was carried out by the USC partner. Nevertheless, the experimental 4 measurements at ORNL of both gamma and neutron sources for the purpose of constructing Detector Response Functions (DRFs) with the associated uncertainties were indeed completed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computer simulation of the CSPAD, ePix10k, and RayonixMX170HS X-ray detectors

The invention of free-electron lasers (FELs) has opened a door to an entirely new level of scientific research. The Linac Coherent Light Source (LCLS) at SLAC National Accelerator Laboratory is an X-ray FEL that houses several instruments, each with its own unique X-ray applications. This light source is revolutionary in that while its properties allow for a whole new range of scientific opportunities, it also poses numerous challenges. For example, the intensity of a focused X-ray beam is enough to damage a sample in one mere pulse; however, the pulse speed and extreme brightness of the source together are enough to obtain enough information about that sample, so that no further measurements are necessary. An important device in the radiation detection process, particularly for X-ray imaging, is the detector. The power of the LCLS X-rays has instigated a need for better performing detectors. The research conducted for this project consisted of the study of X-ray detectors to imitate their behaviors in a computer program. The analysis of the Rayonix MX170-HS, CSPAD, and ePix10k in particular helped to understand their properties. This program simulated the interaction of X-ray photons with these detectors to discern the patterns of their responses. A scientist’s selection process of a detector for a specific experiment is simplified from the characterization of the detectors in the program.

43 PARTICLE ACCELERATORS↗

Deep Learning enabled spectral energy conversion for in situ exposure measurements

A detector-specific deep learning (DL) approach is presented for spectra-to-exposure conversion using large-format sodium iodide (NaI(Tl)) detectors deployed for in situ environmental radiation measurements in emergency response scenarios. Accurate determination of exposure from NaI spectra is challenging due to poor energy resolution, partial energy absorption, and the strong sensitivity of traditionally deployed analytical conversion methods to calibrated source geometry and pre-deployment assumptions. Here, to address these limitations, a multi-layer perceptron model was trained on a hybrid in situ /Monte Carlo dataset constructed to span a broad range of photon energies, spatial extents, and realistic deployment variability, representative of general in situ emergency response conditions. The DL model was evaluated against commonly fielded analytical approaches under matched simulation conditions, including a single-factor method, a G-function method, and a modeled pressurized ion chamber (PIC) baseline. This study was intentionally computational in scope to enable controlled, like-for-like comparisons between conversion techniques while minimizing confounding real-world variability. Comparison to the modeled PIC provides contextual benchmarking and is not intended as a field inter-comparison with deployed instruments. Across the evaluated 20 keV to 3 MeV energy range, the DL approach consistently exhibited higher accuracy and reduced variance relative to the analytical methods against a deterministically calculated exposure. This may indicate improved robustness to spectral complexity without reliance on source-, geometric-, or spectral region-specific optimization. While results do not represent real-world validation, the presented work demonstrates that deep learning may effectively learn the nonlinear detector response-to-exposure relationship for asymmetric NaI(Tl) detectors and offers a promising pathway for improving in situ exposure estimation using spectroscopic systems already integrated into initial real-time emergency response operations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization and Analysis of InGaAsSb Detectors

Profiling of atmospheric CO2 at 2 micron wavelength using the LIDAR technique, has recently gained interest. Although several detectors might be suitable for this application, an ideal device would have high gain, low noise and narrow spectral response peaking around the wavelength of interest. This increases the detector signal-to-noise ratio and minimizes the background signal, thereby increasing the device sensitivity and dynamic range. Detectors meeting the above idealized criteria are commercially unavailable for this particular wavelength. In this paper, the characterization and analysis of Sb-based detectors for 2 micron lidar applications are presented. The detectors were manufactured by AstroPower, Inc., with an InGaAsSb absorbing layer and AlGaAsSb passivating layer. The characterization experiments included spectral response, current versus voltage and noise measurements. The effect of the detectors bias voltage and temperature on its performance, have been investigated as well. The detectors peak responsivity is located at the 2 micron wavelength. Comparing three detector samples, an optimization of the spectral response around the 2 micron wavelength, through a narrower spectral period was observed. Increasing the detector bias voltage enhances the device gain at the narrow spectral range, while cooling the device reduces the cut-off wavelength and lowers its noise. Noise-equivalent-power analysis results in a value as low as 4 x 10(exp -12) W/Hz(exp 1/2) corresponding to D* of 1 x 10(exp 10) cmHz(exp 1/2)/W, at -1 V and 20 C. Discussions also include device operational physics and optimization guidelines, taking into account peculiarity of the Type II heterointerface and transport mechanisms under these conditions.

Abedin, M. Nurul↗

Numerical convergence and validation of the DIMP inverse particle transport model

The data integration with modeled predictions (DIMP) model is a promising inverse radiation transport method for solving the special nuclear material (SNM) holdup problem. Unlike previous methods, DIMP is a completely passive nondestructive assay technique that requires no initial assumptions regarding the source distribution or active measurement time. DIMP predicts the most probable source location and distribution through Bayesian inference and quasi-Newtonian optimization of predicted detector re-sponses (using the adjoint transport solution) with measured responses. DIMP performs well with for-ward hemispherical collimation and unshielded measurements, but several considerations are required when using narrow-view collimated detectors. DIMP converged well to the correct source distribution as the number of synthetic responses increased. DIMP also performed well for the first experimental validation exercise after applying a collimation factor, and sufficiently reducing the source search vol-ume's extent to prevent the optimizer from getting stuck in local minima. DIMP's simple point detector response function (DRF) is being improved to address coplanar false positive/negative responses, and an angular DRF is being considered for integration with the next version of DIMP to account for highly collimated responses. Overall, DIMP shows promise for solving the SNM holdup inverse problem, especially once an improved optimization algorithm is implemented.

42 ENGINEERING↗

Xenon doping of liquid argon in ProtoDUNE single phase

The Deep Underground Neutrino Experiment (DUNE) will be the next generation long-baseline neutrino experiment. The far detector is designed as a complex of four LAr-TPC (Liquid Argon Time Projection Chamber) modules with 17 kt of liquid argon each. The development and validation of the first far detector technology is pursued through ProtoDUNE Single Phase (ProtoDUNE-SP), a 770 t LAr-TPC at CERN Neutrino Platform. Crucial in DUNE is the photon detection system that will ensure the trigger of non-beam events — proton decay, supernova neutrino burst and BSM searches — and will improve the timing and calorimetry for neutrino beam events. Doping liquid argon with xenon is a known technique to shift the light emitted by argon (128 nm) to a longer wavelength (178 nm) to ease its detection. The largest xenon doping test ever performed in a LAr-TPC was carried out in ProtoDUNE-SP. From February to May 2020, a gradually increasing amount of xenon was injected to also compensate for the light loss due to air contamination. The response of such a large TPC has been studied using the ProtoDUNE-SP Photon Detection System (PDS) and a dedicated setup installed before the run. With the first it was possible to study the light collection efficiency with respect to the track position, while with the second it was possible to distinguish the xenon light (178 nm) from the LAr light (128 nm). The light shifting mechanism proved to be highly efficient even at small xenon concentrations (<20 ppm in mass) furthermore it allowed recovering the light quenched by pollutants. The light collection improved far from the detection plane, enhancing the photon detector response uniformity along the drift direction and confirming a longer Rayleigh scattering length for 178 nm photons, with respect to 128 nm ones. The charge collection by the TPC was monitored proving that xenon up to 20 ppm does not impact its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of MODIS Thermal Emissive Bands On-orbit Calibration Algorithms

Two nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODIS) are currently operated on-board the Terra and Aqua spacecrafts, launched in December 1999 and May 2002, respectively. Together, they have produced an unprecedented amount of science data products, which are widely used for the studies of changes in the Earth's system of land, oceans, and atmosphere. MODIS is a cross-track scanning radiometer, which uses a two-sided scan mirror and collects data continuously over a wide scan angle range (+/-55 degree relative to the instrument nadir) each scan of 1.47 seconds. It has 36 spectral bands with wavelengths ranging from visible (VIS) to long-wave infrared (LWIR). MODIS bands 1-19 and 26 are the reflective solar bands (RSB) and bands 20-25 and 27-36 are the thermal emissive bands (TEB). MODIS was developed and designed with improvements made over its heritage sensors (such as AVHRR and Landsat) and, in particular, with more stringent calibration requirements. Because of this, MODIS was built with a set of state-of-art on-board calibrators (OBC), which include a solar diffuser (SD), a solar diffuser stability monitor (SDSM), a blackbody (BB), a spectroradiometric calibration assembly (SRCA), and a space view (SV) port. With the exception of view angle differences, MODIS OBC measurements and the Earth View (EV) observations are made via the same optical path. MODIS TEB have a total of 160 individual TEB detectors (10 per band), which are located on two cold focal plane assemblies (CFPA). For nominal on-orbit operation, the CFPA temperature is controlled at 83K via a passive radiative cooler. For the TEB, the calibration requirements at specified typical scene radiances are less than or equal to 1% with an exception for the fire detection (low gain) band. MODIS TEB on-orbit calibration is performed on a scan-by-scan basis using a quadratic calibration algorithm, and data collected from sensor responses to the onboard BB and SV. The BB serves as the thermal calibration source and the SV provides measurements for the sensor's background and offsets. MODIS on-board BB is a v-grooved plate with its temperature measured using 12 platinum resistive thermistors (PRT) uniformly embedded in the BB substrate. All the BB thermistors were characterized pre-launch with reference to the NIST temperature standards. Unlike typical BB operations in many heritage sensors, which have no temperature control capability, the MODIS on-board BB can be operated at any temperatures between instrument ambient (about 270K) and 315K and can also be varied continuously within this range. This feature has significantly enhanced the MODIS' capability of tracking and updating the TEB nonlinear calibration coefficients over its entire mission. Following a brief description of MODIS TEB on-orbit calibration methodologies and its onboard BB operational activities, this paper provides a comprehensive performance assessment of MODIS TEB quadratic calibration algorithm. It examines the scan-by-scan, orbit-by-orbit, daily, and seasonal variations of detector responses and associated impact due changes in the CFPA and instrument temperatures. Specifically, this paper will analyze the contribution by each individual thermal emissive source term (BB, scan cavity, and scan mirror), the impact on the Level 1 B data product quality due to pre-launch and on-orbit calibration uncertainties. A comparison of Terra and Aqua TEB on-orbit performance, lessons learned, and suggestions for future improvements will also be made.

Xiong, Xiaoxiong↗

Nonproportional scintillation response of NaI:Tl to low energy x-ray photons and electrons

Nonproportional response of the scintillation yield of NaI:Tl was measured using highly monochromatic synchrotron irradiation ranging from 9-100 keV. Special attention is paid to the x-ray escape peaks. They provide us additional information about photon response in the range 0.9-12 keV. A rapid variation in the photon response curve is observed near the iodine K-electron binding energy. A dense sampling of data is performed around this energy and that data are used to apply a method, which we call K-dip spectroscopy. This method allows us to derive the electron response curve of NaI:Tl down to energies as low as 30 eV. A comparison of our data with data of others employing different methods is made. Advantages, limitations, and peculiarities of presented techniques and methods are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new neutron time-of-flight detector for yield and ion-temperature measurements at the OMEGA Laser Facility

A new neutron time-of-flight (nTOF) detector for deuterium–deuterium (DD)-fusion yield and ion-temperature measurements was designed, installed, and calibrated for the OMEGA Laser Facility. This detector provides an additional line of sight for DD neutron yield and ion-temperature measurements for yields exceeding 1 × 10 10 with higher precision than existing detectors. The nTOF detector consists of a 90-mm-diam, 20-mm-thick BC-422 scintillator and a gated Photek photomultiplier tube (PMT240). The PMT collects scintillating light through the 20-mm side of the scintillator without the use of a light guide. There is no lead shielding from hard x rays in order to allow the x-ray instrument response function of the detector to be measured easily. Instead, hard x-ray signals generated in implosion experiments are gated out by the PMT. The design provides a place for glass neutral-density filters between the scintillator and the PMT to avoid PMT saturation at high yields. The nTOF detector is installed in the OMEGA Target Bay along the P8A sub-port line of sight at a distance of 5.3 m from the target chamber center. In addition to DD measurements, the same detector can be used to measure the neutron yield and ion temperature from deuterium–tritium (DT) implosion targets in the 5 × 10 10 to 2 × 10 12 yield range. Here, the design details and the calibration results of this nTOF detector for both D 2 and DT implosions on OMEGA will be presented.

47 OTHER INSTRUMENTATION↗

Design Studies for a Far Infrared Absolute Spectrometer for the Cosmic Background Explorer

Unrelenting symmetry of design is required to assure the thermal balance of a cryogenically cooled, rapid scan interferometer spectrometer to be mounted in vacuum with the Cosmic Background Explorer liquid helium dewar. The instrument receives inputs from Winston cone optical flux collectors, one open to space and a second coupled to a black body reference source. A differential instrument, the spectrometer produces outputs corresponding to the Fourier transform of the spectral radiance difference between the two inputs. The two outputs are sensed by four detectors, two optimized for shorter wavelength response, and two optimized for longer wavelengths. The optical design, detector and signal channel, system sensitivity, mechanics, thermal control and cryogenics, electronics and power systems, command and control, calibration, system test requirements, and the instrument interface are discussed. Recommendations for continued work are indicated for the superconducting reflective horns, the motor bearing and drive, and design detail.

Johnson, N. J. E.↗

Calibration of a liquid xenon detector with {sup 83}Kr{sup m}

We report the preparation of a {sup 83}Kr{sup m} source and its use in calibrating a liquid xenon detector. {sup 83}Kr{sup m} atoms were produced through the decay of {sup 83}Rb and introduced into liquid xenon. Decaying {sup 83}Kr{sup m} nuclei were detected through liquid xenon scintillation. Conversion electrons with energies of 9.4 and 32.1 keV from the decay of {sup 83}Kr{sup m} were observed. This calibration source will allow the characterization of the response of noble liquid detectors at low energies. {sup 83}Kr{sup m} may also be useful for measuring fluid flow dynamics, both to understand purification in noble liquid-based particle detectors, as well as for studies of classical and quantum turbulence in superfluid helium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗