Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

The human skin as a sub-THz receiver – Does 5G pose a danger to it or not?

Highlights: • The sweat duct is regarded as a helical antenna in the sub-THz band, reflectance depends on perspiration. • We outline the background for non-thermal effects based on the structure of sweat ducts. • We have introduced a realistic skin EM model and found the expected SAR for the 5G standard. In the interaction of microwave radiation and human beings, the skin is traditionally considered as just an absorbing sponge stratum filled with water. In previous works, we showed that this view is flawed when we demonstrated that the coiled portion of the sweat duct in upper skin layer is regarded as a helical antenna in the sub-THz band. Experimentally we showed that the reflectance of the human skin in the sub-THz region depends on the intensity of perspiration, i.e. sweat duct's conductivity, and correlates with levels of human stress (physical, mental and emotional). Later on, we detected circular dichroism in the reflectance from the skin, a signature of the axial mode of a helical antenna. The full ramifications of what these findings represent in the human condition are still unclear. We also revealed correlation of electrocardiography (ECG) parameters to the sub-THz reflection coefficient of human skin. In a recent work, we developed a unique simulation tool of human skin, taking into account the skin multi-layer structure together with the helical segment of the sweat duct embedded in it. The presence of the sweat duct led to a high specific absorption rate (SAR) of the skin in extremely high frequency band. In this paper, we summarize the physical evidence for this phenomenon and consider its implication for the future exploitation of the electromagnetic spectrum by wireless communication. Starting from July 2016 the US Federal Communications Commission (FCC) has adopted new rules for wireless broadband operations above 24 GHz (5 G). This trend of exploitation is predicted to expand to higher frequencies in the sub-THz region. One must consider the implications of human immersion in the electromagnetic noise, caused by devices working at the very same frequencies as those, to which the sweat duct (as a helical antenna) is most attuned. We are raising a warning flag against the unrestricted use of sub-THz technologies for communication, before the possible consequences for public health are explored.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

LLNL's Diagram of Chronological Events and B695 Weekly Inspection Reports

Activities leading to the incident were: (1) RCRA Class 2 Permit Modification granted on July 25, 2007 to install a walk-in fume hood in room 1025; (2) USQ-695-07-148 to do the work approved on 9/17; (3) ducting removed early October done by Facility Personnel under IWS 10331.09; (4) ducting swiped for 'free release' radioactivity only by team 1 personnel on 10/16; (5) all ducting and valves remained in building 695 room 1025 except for one piece delivered to building 391 (MMED shop); (6) material delivered by facility personnel to MMED shope B391 on about 10/19; (7) MMED personnel took a duct piece to B511 shop and removed the flange which went to salvage; (8) MMED personnel took the duct piece back to B391 shop and welded on a cap; (9) RHWM personnel picked up the welded duct from B391 around 10/26 and returned ti to B695 room 1025; and (10) the analysis report receive don 12/3 indicated that beryllium swipes take on 11/16, in B695 room 1025, and on ducting that did not leave the room where personnel worked, were above the release level for beryllium.

54 ENVIRONMENTAL SCIENCES↗

Demonstration of An Integrated Approach to Mercury Control at Lee Station

General Electric (GE) has developed an approach whereby native mercury reduction on fly ash can be improved by optimizing the combustion system. This approach eliminates carbon-rich areas in the combustion zone, making the combustion process more uniform, and allows increasing carbon content in fly ash without significant increase in CO emissions. Since boiler excess O{sub 2} can be also reduced as a result of optimized combustion, this process reduces NO{sub x} emissions. Because combustion optimization improves native mercury reduction on fly ash, it can reduce requirements for activated carbon injection (ACI) when integrated with sorbent injection for more efficient mercury control. The approach can be tailored to specific unit configurations and coal types for optimal performance. This report describes results of a U.S. DOE sponsored project designed to evaluate the effect of combustion conditions on 'native' mercury capture on fly ash and integrate combustion optimization for improved mercury and NO{sub x} reduction with ACI. The technology evaluation took place in Lee Station Unit 3 located in Goldsboro, NC and operated by Progress Energy. Unit 3 burns a low-sulfur Eastern bituminous coal and is a 250 MW opposed-wall fired unit equipped with an ESP with a specific collection area of 249 ft{sup 2}/kacfm. Unit 3 is equipped with SO{sub 3} injection for ESP conditioning. The technical goal of the project was to evaluate the technology's ability to achieve 70% mercury reduction below the baseline emission value of 2.9 lb/TBtu, which was equivalent to 80% mercury reduction relative to the mercury concentration in the coal. The strategy to achieve the 70% incremental improvement in mercury removal in Unit 3 was (1) to enhance 'naturally' occurring fly ash mercury capture by optimizing the combustion process and using duct humidification to reduce flue gas temperatures at the ESP inlet, and (2) to use ACI in front of the ESP to further reduce mercury emissions. The program was comprised of field and pilot-scale tests, engineering studies and consisted of eight tasks. As part of the program, GE conducted pilot-scale evaluation of sorbent effect on mercury reduction, supplied and installed adjustable riffle boxes to assist in combustion optimization, performed combustion optimization, supplied mobile sorbent injection and flue gas humidification systems, conducted CFD modeling of sorbent injection and flue gas humidification, and performed mercury testing including a continuous 30-day sorbent injection trial. Combustion optimization was the first step in reduction of mercury emissions. Goals of combustion optimization activities were to improve 'native' mercury capture on fly ash and reduce NO{sub x}. Combustion optimization included balancing of coal flow through individual burners to eliminate zones of carbon-rich combustion, air flow balancing, and burner adjustments. As part of the project, the original riffle boxes were replaced with Foster-Wheeler's adjustable riffle boxes to allow for biasing the coal flow between the coal pipes. A 10-point CO/O{sub 2}/NO{sub x} grid was installed in the primary superheater region of the back pass to assist in these activities. Testing of mercury emissions before and after combustion optimization demonstrated that mercury emissions were reduced from 2.9 lb/TBtu to 1.8 lb/TBtu due to boiler operation differences in conjunction with combustion optimization, a 38% improvement in 'native' mercury capture on fly ash. Native mercury reduction from coal was {approx}42% at baseline conditions and 64% at optimized combustion conditions. As a result of combustion optimization NO{sub x} emissions were reduced by 18%. A three-dimensional CFD model was developed to study the flow distribution and sorbent injection in the post air heater duct in Lee Station Unit 3. Modeling of the flow pattern exiting the air pre-heater demonstrated that because of the duct transition from a circular opening at the exit of air-pre-heater to a rectangular ESP inlet duct, flow separation occurred at the corners after the transition. Modeling also demonstrated that the flow was severely biased from the South side to the North side due to the bend of the duct. Results of CFD modeling were used to design lances for better sorbent distribution across the ESP inlet duct. Modeling of water injection demonstrated that because of flue gas temperature biasing, the droplet evaporation rate was slower on the North side than that on the South side of the duct. Modeling suggested that an improvement of water droplet evaporation could be achieved by closing the lance on the North side where flue gas temperatures were lower. Preliminary evaluation of the effect of carbon-based sorbents on mercury reduction took place in a 1 MBtu/hr (300 kW) Boiler Simulator Facility using the same coal as fired at Lee Station.

01 COAL, LIGNITE, AND PEAT↗

The research progress of some key problems about the protection of industrial electron irradiation accelerator - Paper 9

In the last decades, electronic irradiation accelerator has made great progress and been widely used in fields. Because of its distinguishing feature of reliability and safety, electronic irradiation accelerator has attracted more attention of the investors, and created a huge economic value and social benefits. It will become the mainstream equipment of irradiation processing industry in future. So the further study of the shielding design around irradiation accelerator is of great significance. Different designs of ventilation duct will greatly influence dose rate of the exit. Because of the high dose rate under the target, it is suitable to use multi-tortuous duct when duct locating under target. It will reduce the dose rate about 3 orders of magnitude at the exit that add one backscattering interface in duct. Choose reasonable diameter and angle of embedded duct so that photons scatter as much as possible. We can use multiple small diameter ducts to replace large diameter duct. The system of Mini-DDL, Gamma detector and PC give a better reflection on the running statue of accelerator, its perfect usability can produce intuitive images for analyzed, it is important and helpful for workers and researchers to know about the radiation level of machine and environment. The measured results along the maze show that the maze must be long enough in order to achieve the desired shielding thickness. In future, we will combine the different kinds and motor patterns of body models, Monte Carlo programs, real time monitoring system with theoretical calculations to explore how the radiation field around accelerator has impact on human organs, get the dose distribution of body models so that improve the radiation protection to electron accelerator. (authors)

43 PARTICLE ACCELERATORS↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Argon/UF6 plasma exhaust gas reconstitution experiments using preheated fluorine and on-line diagnostics

The feasibility of employing a flowing, high-temperature, pure fluorine/UF6 regeneration system to efficiently convert a large fraction of the effluent plasma exhaust back to pure UF6 was demonstrated. The custom built T.O.F. mass spectrometer sampling system permitted on-line measurements of the UF6 concentration at different locations in the exhaust system. Negligible amounts ( 100 ppm) of UF6 were detected in the axial bypass exhaust duct and the exhaust ducts downstream of the cryogenic trap system used to collect the UF6, thus verifying the overall system efficiency over a range of operating conditions. Use of a porous Monel duct as part of the exhaust duct system, including provision for injection of pure fluorine, provided a viable technique to eliminate uranium compound residue on the inside surface of the exhaust ducts. Typical uranium compound mass deposition per unit area of duct was 2 micron g/sq cm. This porous duct technique is directly applicable to future uranium compound transfer exhaust systems. Throughout these experiments, additional basic data on the corrosion aspects of hot, pressurized UF6/fluorine were also accumulated.

Roman, W. C.↗

Effects of interstage diffuser flow distortion on the performance of a 15.41-centimeter tip diameter axial power turbine

The performance of a variable-area stator, axial flow power turbine was determined in a cold-air component research rig for two inlet duct configurations. The two ducts were an interstage diffuser duct and an accelerated-flow inlet duct which produced stator inlet boundary layer flow blockages of 11 percent and 3 percent, respectively. Turbine blade total efficiency at design point was measured to be 5.3 percent greater with the accelerated-flow inlet duct installed due to the reduction in inlet blockage. Blade component measurements show that of this performance improvement, 35 percent occurred in the stator and 65 percent occurred in the rotor. Analysis of inlet duct internal flow using an Axisymmetric Diffuser Duct Code (ADD Code) were in substantial agreement with the test data.

Mclallin, K. L.↗

Effects of interstage diffuser flow distortion on the performance of a 15.41-centimeter tip diameter axial power turbine

The performance of a variable-area stator, axial flow power turbine was determined in a cold-air component research rig for two inlet duct configurations. The two ducts were an interstage diffuser duct and an accelerated-flow inlet duct which produced stator inlet boundary layer flow blockages of 11 percent and 3 percent, respectively. Turbine blade total efficiency at design point was measured to be 5.3 percent greater with the accelerated-flow inlet duct installed due to the reduction in inlet blockage. Blade component measurements show that of this performance improvement, 35 percent occurred in the stator and 65 percent occurred in the rotor. Analysis of inlet duct internal flow using an Axisymmetric Diffuser Duct Code (ADD Code) were in substantial agreement with the test data.

Mclallin, K. L.↗

Detonation wave compression in gas turbines

A study was made of the concept of augmenting the performance of low pressure ratio gas turbines by detonation wave compression of part of the flow. The concept exploits the constant volume heat release of detonation waves to increase the efficiency of the Brayton cycle. In the models studied, a fraction of the compressor output was channeled into detonation ducts where it was processed by transient transverse detonation waves. Gas dynamic studies determined the maximum cycling frequency of detonation ducts, proved that upstream propagation of pressure pulses represented no problems and determined the variations of detonation duct output with time. Mixing and wave compression were used to recombine the combustor and detonation duct flows and a concept for a spiral collector to further smooth the pressure and temperature pulses was presented as an optional component. The best performance was obtained with a single firing of the ducts so that the flow could be re-established before the next detonation was initiated. At the optimum conditions of maximum frequency of the detonation ducts, the gas turbine efficiency was found to be 45 percent while that of a corresponding pressure ratio 5 conventional gas turbine was only 26%. Comparable improvements in specific fuel consumption data were found for gas turbines operating as jet engines, turbofans, and shaft output machines. Direct use of the detonation duct output for jet propulsion proved unsatisfactory. Careful analysis of the models of the fluid flow phenomena led to the conclusion that even more elaborate calculations would not diminish the uncertainties in the analysis of the system. Feasibility of the concept to work as an engine now requires validation in an engineering laboratory experiment.

Wortman, A.↗

Flow in out-of-plane double S-bends

An experimental investigation of developing flows through a combination of out-of-plane S-bend ducts was conducted to gain insight into the redirection of flow in geometries similar to those encountered in practical aircraft wing-root intake ducts. The present double S-bend was fabricated by placing previously investigated S-ducts and S-diffusers in series and with perpendicular planes of symmetry. Laser-Doppler anemometry was employed to measure the three components of mean velocity, the corresponding rms quantities, and Reynolds stresses in the rectangular cross-section ducts. Due to limited optical access, only two mean and rms velocity components were resolved in the circular cross-section ducts. The velocity measurements were complemented by wall static pressure measurements. The data indicates that the flows at the exit are complex and asymmetric. Secondary flows generated by the pressure field in the first S-duct are complemented or counteracted by the secondary flows produced by the area expansion and the curvature of the S-diffuser. The results indicate the dominance of the inlet conditions and geometry upon the development of secondary flows and demonstrate that the flows are predominantly pressure-controlled. The pressure distribution caused by the duct geometry determines the direction and magnitude of the bulk flow while the turbulence dictates the mixing characteristics and profiles in the near wall region.

Schmidt, M. C.↗

Active Control of Fan-Generated Tone Noise

This paper reports on an experiment to control the noise radiated from the inlet of a ducted fan using a time domain active adaptive system. The control ,sound source consists of loudspeakers arranged in a ring around the fan duct. The error sensor location is in the fan duct. The purpose of this experiment is to demonstrate that the in-duct error sensor reduces the mode spillover in the far field, thereby increasing the efficiency of the control system. The control system is found to reduce the blade passage frequency tone significantly in the acoustic far field when the mode orders of the noise source and of the control source are the same, when the dominant wave in the duct is a plane wave. The presence of higher order modes in the duct reduces the noise reduction efficiency, particularly near the mode cut-on where the standing wave component is strong, but the control system converges stably. The control system is stable and converges when the first circumferential mode is generated in the duct. The control system is found to reduce the fan noise in the far field on an arc around the fan inlet by as much as 20 dB with none of the sound amplification associated with mode spillover.

Gerhold, Carl H.↗

Simulation System for Training in Laparoscopic Surgery

A computer-based simulation system creates a visual and haptic virtual environment for training a medical practitioner in laparoscopic surgery. Heretofore, it has been common practice to perform training in partial laparoscopic surgical procedures by use of a laparoscopic training box that encloses a pair of laparoscopic tools, objects to be manipulated by the tools, and an endoscopic video camera. However, the surgical procedures simulated by use of a training box are usually poor imitations of the actual ones. The present computer-based system improves training by presenting a more realistic simulated environment to the trainee. The system includes a computer monitor that displays a real-time image of the affected interior region of the patient, showing laparoscopic instruments interacting with organs and tissues, as would be viewed by use of an endoscopic video camera and displayed to a surgeon during a laparoscopic operation. The system also includes laparoscopic tools that the trainee manipulates while observing the image on the computer monitor (see figure). The instrumentation on the tools consists of (1) position and orientation sensors that provide input data for the simulation and (2) actuators that provide force feedback to simulate the contact forces between the tools and tissues. The simulation software includes components that model the geometries of surgical tools, components that model the geometries and physical behaviors of soft tissues, and components that detect collisions between them. Using the measured positions and orientations of the tools, the software detects whether they are in contact with tissues. In the event of contact, the deformations of the tissues and contact forces are computed by use of the geometric and physical models. The image on the computer screen shows tissues deformed accordingly, while the actuators apply the corresponding forces to the distal ends of the tools. For the purpose of demonstration, the system has been set up to simulate the insertion of a flexible catheter in a bile duct. [As thus configured, the system can also be used to simulate other endoscopic procedures (e.g., bronchoscopy and colonoscopy) that include the insertion of flexible tubes into flexible ducts.] A hybrid approach has been followed in developing the software for real-time simulation of the visual and haptic interactions (1) between forceps and the catheter, (2) between the forceps and the duct, and (3) between the catheter and the duct. The deformations of the duct are simulated by finite-element and modalanalysis procedures, using only the most significant vibration modes of the duct for computing deformations and interaction forces. The catheter is modeled as a set of virtual particles uniformly distributed along the center line of the catheter and connected to each other via linear and torsional springs and damping elements. The interactions between the forceps and the duct as well as the catheter are simulated by use of a ray-based haptic-interaction- simulating technique in which the forceps are modeled as connected line segments.

Basdogan, Cagatay↗

Configuration Effects on Liner Performance

The acoustic performance of a duct liner depends not only on the intrinsic properties of the liner but also on the configuration of the duct in which it is used. A series of experiments is performed in the NASA Langley Research Center Curved Duct Test Rig (at Mach 0.275) to evaluate the effect of duct configuration on the acoustic performance of single degree of freedom perforate-over-honeycomb liners. The liners form the sidewalls of the duct's test section. Variations of duct configuration include: asymmetric (liner on one side and hard wall opposite) and symmetric (liner on both sides) wall treatment; inlet and exhaust orientation, in which the sound propagates either against or with the flow; and straight and curved flow path. The effect that duct configuration has on the overall acoustic performance, particularly the shift in frequency and magnitude of peak attenuation, is quantified. The redistribution of incident mode content is shown. The liners constitute the side walls of the liner test section and the scatter of incident horizontal order 1 mode by the asymmetric treatment and order 2 mode by the symmetric treatment into order 0 mode is shown. Scatter of order 0 incident modes into higher order modes is also shown. This redistribution of mode content is significant because it indicates that the liner design can be manipulated such that energy is scattered into more highly attenuated modes, thus enhancing liner performance.

Gerhold, Carl H.↗

Further Development of Rotating Rake Mode Measurement Data Analysis

The Rotating Rake mode measurement system was designed to measure acoustic duct modes generated by a fan stage. After analysis of the measured data, the mode amplitudes and phases were quantified. For low-speed fans within axisymmetric ducts, mode power levels computed from rotating rake measured data would agree with the far-field power levels on a tone by tone basis. However, this agreement required that the sound from the noise sources within the duct propagated outward from the duct exit without reflection at the exit and previous studies suggested conditions could exist where significant reflections could occur. To directly measure the modes propagating in both directions within a duct, a second rake was mounted to the rotating system with an offset in both the axial and the azimuthal directions. The rotating rake data analysis technique was extended to include the data measured by the second rake. The analysis resulted in a set of circumferential mode levels at each of the two rake microphone locations. Radial basis functions were then least-squares fit to this data to obtain the radial mode amplitudes for the modes propagating in both directions within the duct. The fit equations were also modified to allow evanescent mode amplitudes to be computed. This extension of the rotating rake data analysis technique was tested using simulated data, numerical code produced data, and preliminary in-duct measured data.

Dahl, Milo D.↗

Multiphysics Demonstration of Temperature-Driven Assembly Bowing in SFRs using MOOSE-Based Codes

Core bowing is an important passive safety mechanism in liquid metal cooled fast reactors. When the core restraint system is properly designed, temperature and flux gradients influence assemblies in the core to bow into less reactive configurations during accident scenarios, resulting in negative reactivity feedback. Prediction of core bowing involves complex interplay of radiation transport, impacts of fluid flow and heat transfer on duct temperature, and mechanical responses to the induced temperature and flux gradients. Under the U.S. Department of Energy Office of Nuclear Energy’s Advanced Modeling and Simulation (NEAMS) Program [1], an integrated multiphysics approach is being developed to model the core bowing phenomena in liquid metal-cooled fast reactors with the Multiphysics Object Oriented Simulation Environment (MOOSE) [2]. In this methodology, the MOOSE-based reactor physics code Griffin [3] will solve the neutron transport equation and determine the power distribution. With the detailed power distribution from Griffin, the subchannel analysis codes MOOSE-Subchannel [4] and Pronghorn [5] are utilized to calculate the assembly temperature distribution. MOOSE’s Solid Mechanics [6] and Contact [7] Modules are leveraged to calculate the thermal expansion and duct bowing displacement with the duct wall temperature from thermal hydraulics calculation. In this work, an initial one-way coupling demonstration of the integrated multiphysics approach has been performed on a seven-assembly problem based on the sodium-cooled fast reactor ABR-1000 design [8]. The neutronics calculation with Griffin is not yet involved in the current simulation. MOOSE-Subchannel and Pronghorn evaluate fluid and solid temperature based on a fixed power distribution. In addition, one-way coupling is utilized in this coupled calculation, via Pronghorn passing the duct temperature data to the MOOSE Solid Mechanics calculation. An assessment of the Solid Mechanics module was performed in parallel to verify duct bowing behavior with duct-to-duct contact phenomenon [9]. The displacement from MOOSE Solid Mechanics is not yet transferred back and utilized in the Pronghorn and MOOSE-Subchannel calculation. This model will be available on the National Reactor Innovation Center (NRIC) Virtual Test Bed (VTB) repository [10]. Future stages of this work will involve solving problems of increasing complexity as well as adding more physics (e.g. reactor physics) to the integrated workflow to reach the end goal of modeling the core bowing phenomenon with an integrated multiphysics workflow.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Conceptual Design of a Tiltduct Reference Vehicle for Urban Air Mobility

NASA is establishing a fleet of conceptual air vehicle designs to support research and development for Urban Air Mobility (UAM). This fleet of vehicles will enable examination of the sensitivity of UAM vehicle designs to technology assumptions, identify key research and development needs for UAM aircraft, and provide the UAM community with reference vehicles that are publicly available and based upon known assumptions. To date, five six-passenger reference vehicles have been published: a quadrotor, a side-by-side, a lift-plus-cruise, a single-main-rotor helicopter, and a tiltwing. To increase the breadth of vehicle technologies encapsulated in the fleet of NASA UAM reference vehicles, this paper establishes a tiltduct vehicle as an addition to the fleet. The fleet will continue to evolve as future analyses and trade studies are performed. The tiltduct reference vehicle has six tilting ducted proprotors. This paper describes the initial configuration downselection; discusses ducted proprotor design rules of thumb as they applied to the conceptual design of the reference vehicle; describes the vehicle sizing, trade studies, and tuning of models performed; and finally, compares the resulting tiltduct vehicle against the other six-passenger NASA UAM reference vehicles. The high-level analyses performed for this study did not indicate significant differences in performance between the tiltduct and tiltwing reference vehicles, and so vehicle performance alone may not be a key driver in the selection of a tiltduct vehicle over a tiltwing vehicle. However, if ducts are found to have significant acoustical benefits, then acoustical priorities may provide a compelling reason to incorporate ducted proprotors. One significant limitation of the design presented in this paper is that the ducted proprotor performance was tuned based upon performance characteristics observed during historical tests with disk loadings (defined as thrust divided by proprotor disk area) of 125-250 lb/ft^2. The tiltduct vehicle designed in this study has a disk loading of 30 lb/ft^2, to be more representative of UAM vehicles; further studies to understand performance of ducted proprotors at representative disk loadings are warranted.

Tiltduct↗

Core materials development for the fuel cycle R&D program

The Fuel Cycle Research and Development program is investigating methods of burning minor actinides in a transmutation fuel. One of the challenges of achieving this goal is to develop fuels capable of reaching extreme burnup levels (e.g. 40%). To achieve such high burnup levels’ fast reactor core materials (cladding and duct) must be able to withstand very high doses (>300 dpa design goal) while in contact with the coolant and the fuel. Thus, these materials must withstand radiation effects that promote low temperature embrittlement, radiation induced segregation, high temperature helium embrittlement, swelling, accelerated creep, corrosion with the coolant, and chemical interaction with the fuel (FCCI). To develop and qualify materials to a total fluence greater than 200 dpa requires development of advanced alloys and irradiations in fast reactors to test these alloys. Test specimens of ferritic/martensitic alloys (T91/HT-9) previously irradiated in the FFTF reactor up to 210 dpa at a temperature range of 350– 750 °C are presently being tested. This includes analysis of a duct made of HT-9 after irradiation to a total dose of 155 dpa at temperatures from 370 to 510 °C. Compact tension, charpy and tensile specimens have been machined from this duct and mechanical testing as well as SANS and Mossbauer spectroscopy are currently being performed. Initial results from compression testing and Charpy testing reveal a strong increase in yield stress (~400 MPa) and a large increase in DBTT (up to 230 °C) for specimens irradiated at 383 °C to a dose of 28 dpa. Less hardening and a smaller increase in DBTT was observed for specimens irradiated at higher temperatures up to 500 °C. Advanced radiation tolerant materials are also being developed to enable the desired extreme fuel burnup levels. Specifically, coatings are being developed to minimize FCCI, and research is underway to fabricate large heats of radiation tolerant oxide dispersion steels with homogeneous oxide dispersions.

Maloy, S. A.↗

Conceptual Design of a Tiltduct Reference Vehicle for Urban Air Mobility

NASA is establishing a fleet of conceptual air vehicle designs to support research and development for Urban Air Mobility (UAM). This fleet of vehicles will enable examination of the sensitivity of UAM vehicle designs to technology assumptions, identify key research and development needs for UAM aircraft, and provide the UAM community with reference vehicles that are publicly available and based upon known assumptions. To date, five six-passenger UAM reference vehicles have been published: a single-main-rotor helicopter, a side-by-side helicopter, a quadrotor, a lift-plus-cruise, and a tiltwing. To increase the breadth of vehicle technologies encapsulated in the fleet of NASA UAM reference vehicles, this paper establishes a tiltduct vehicle as an addition to the fleet. The fleet will continue to evolve as future analyses and trade studies are performed. The tiltduct UAM reference vehicle has six tilting ducted proprotors. This paper describes the initial configuration downselection; discusses ducted proprotor design rules of thumb as they applied to the conceptual design of the reference vehicle; describes the vehicle sizing, trade studies, and tuning of models performed; and finally, compares the resulting tiltduct vehicle against the other six-passenger NASA UAM reference vehicles. The high-level analyses performed for this study did not indicate significant differences in performance between the tiltduct and tiltwing reference vehicles, and so vehicle performance alone may not be a key driver in the selection of a tiltduct vehicle over a tiltwing vehicle. However, if ducts are found to have significant acoustical benefits, then acoustical priorities may provide a compelling reason to incorporate ducted proprotors. One significant limitation of the design presented in this paper is that the ducted proprotor performance was tuned based upon performance characteristics observed during historical tests with disk loadings (defined as thrust divided by proprotor disk area) of 125-250 lb/ft$^2$. The tiltduct vehicle designed in this study has a disk loading of 30 lb/ft$^2$, to be more representative of UAM vehicles; further studies to understand performance of ducted proprotors at representative disk loadings are warranted.

Tiltduct↗