Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

The LASSO experiment

An international coordinated experimental assessment of a system which promises to provide a synchronization of clocks bound to time and frequency standard laboratories, with an accuracy of one nanosecond using existing or near ground-based laser stations via a geostationary satellite (SIRIO-2) is detailed. The system performance and the technical details concerning the on-board equiment, the ground segment, and the operational configuration are discussed. Finally, the future prospects of the LASSO experiment and possible implementations are examined together.

Serene, B.↗

Time dissemination: An update

A brief description of some of the improvements in the generation and dissemination of precise time and time interval at the U.S. Naval Observation are described. Details on some of the newer hardware developed for this purpose are presented. Data from tests of two of the more significant items, a small portable clock with performance approaching that of larger units and a GPS Time Transfer Unit capable of time transfer to an accuracy of less than 100 nanoseconds, are also given.

Putkovich, K.↗

T and F comparisons via broadcasting satellite and navigation technology satellite

The preliminary time/frequency dissemination experiments were made using the BSE. In order to establish the technique of the doppler shift canceling, the phase control servo including the satellite link and the precompensating frequency control using the measured values or using the orbital data of the satellite are tested. The amount of the residual doppler shift at the control station can be reduced to the order of 1 part in 10 to the 12th power or less by use of the first and the second methods. The method using the orbit data is expected to give a control capability of a few parts in 10 to 11th power. Thus, the maximum value of the doppler shift at the farther most place of the country is estimated to be + or - 2 x 10 to the -10 power without any correction. The experiment of the international time comparison via the NTS 1 was made for about one year since October 1978. The data of time difference between UTC(USNO) and UTC(RRL) are in good agreement with those via the portable clock of the USNO. By applying the correction for ionospheric delay the standard deviation of the data can be reduced to about one-half.

Saburi, Y.↗

One way time transfer via Meteosat capable of 30 (ns accuracy

The METEOSAT ranging signal's available every 3 hours for about 1.5 minutes, its phase is measured against the second pulses of the station clocks. A system study shows that the accuracy obtainable could be in the order of 30 ns. The receiver unit consists of a 2 m diameter fixed antenna, a low noise broadband receiver, and a phase tracker and demodulator. The overall costs will be less than $20.000 US.

Nottarp, K.↗

Time coded distribution via broadcasting stations

The distribution of standard time signals via AM and FM broadcasting stations presents the distinct advantages to offer a wide area coverage and to allow the use of inexpensive receivers, but the signals are radiated a limited number of times per day, are not usually available during the night, and no full and automatic synchronization of a remote clock is possible. As an attempt to overcome some of these problems, a time coded signal with a complete date information is diffused by the IEN via the national broadcasting networks in Italy. These signals are radiated by some 120 AM and about 3000 FM and TV transmitters around the country. In such a way, a time ordered system with an accuracy of a couple of milliseconds is easily achieved.

Leschiutta, S.↗

A study of time dissemination via satellite in India

A simultaneous two way clock synchronization experiment between three Earth stations, was performed and improvements over the technique earlier attempted in which transmit/receive roles of the two stations were alternated at regular intervals, were studied. Time signals via two modes high frequency and satellite were critically monitored and analyzed. This time format was modified to include the additional information about time of the day in year, month, day, hour, minute and second as well as DUT1 in BCD code and was disseminated via the satellite. These signals were decoded, displayed and studied. Some preliminary work on time transfer via TV using direct satellite broadcast, was also conducted.

Mathur, B. S.↗

Two-Way Time Transfer via Geostationary Satellites NRC/NBS, NRC/USNO and NBS/USNO via Hermes and NRC/LPTF (France) via Symphonie

In most of the experiments, 1 pps pulses of the station atomic clocks were exchanged between the partners, and a cubic equation was fitted to the 1000 to 2000 second measurements. The equations were exchanged and substracted to obtain the time difference of the stations. The standard deviation in the fit of the equations varied, depending on conditions, from 1.5 ns to 16 ns. For the last month of the Hermes experiment, a 1 MHz signal was used, giving a standard deviation of 0.18 ns. The comparison of the time scales via satellite and via Loran-C (BIH Circular D) show clearly that some Loran-C links are very good, but that the NBS link varies by 1 micron s. Via the satellite the frequencies of the time scales can be compared with an accuracy of 2 x 10 to the minus 14 power.

Costain, C.↗

The frequency and time standard and activities at the Beijing Institute of Radio Metrology and Measurements

Three kinds of frequency measuring systems are described: frequency comparison, phase comparison, and time comparison. With the help of the portable cesium clock in determining the time delay between two stations, a time synchronization, experiment was conducted using the Symphonie satellite. A result with an accuracy of 30 ns and an uncertainty of about 10 ns was obtained. Another experiment, applying the television pulse technique for time synchronization, yielded a result with an error of about 0.5 mu s in 24 hours. In order to measure the short term frequency stability of crystal oscillators or other frequency sources, a rubidium maser atomic frequency standard was developed as well as a short term stability measuring system.

Wang, H. T.↗

Recent progress of the research work on frequency and time at the NIM

Chinese activities reported include (1) research and development on the primary cesium beam standard and the high precision crystal oscillator; (2) keeping the atomic time and calibrating frequency standards; (3) determining methods for transferring the standard frequency at the highest precision. The primary beam installation gives an accuracy of 1.2 x 10 to the minus 12 power (1 sigma). Improvements are being made to attain an uncertainity goal of the order of 10 to the minus 13 power. Two experiments conducted are described. One involved standard frequency transfer via TV color subcarrier; the other involved time synchronization via Symphonie satellite. The best results are the random fluctuation of direct measurement data is 1 sigma sub r (RMS) 10 ns, and the absolute error of clock synchronization is 1 sigma sub A (RMS) 30 ns.

Bingying, H.↗

Progress report on the Block 1 VLBI correlator implementation

The Block 1 VLBI Processor Subsystem (VPS) of the Very Long Baseline Interferometry (VLBI) System for the determination of station clock-sync parameters, UT1 and polar motion, and station platform parameters and for use in spacecraft tracking is discussed. The Block 1 VPS performs three basic functions: it receives the 500 kbit/sec video data over the GCF wideband data lines from each of the three DSN 64 m antennas; it cross correlates data; and it performs several postcorrelation data reduction operations on the correlated data including calibration, editing, and parameter estimation.

Peterson, J. C.↗

Block 1, phase 1 very long baseline interferometry implementation

The Block 1, phase 1 VBLI System, implemented in the Deep Space Network and currently undergoing system testing, is discussed. The system can be characterized as the modification of existing equipment and the addition of new software in the 64 m subnet and the addition of new hardware and software in the Network Operations and Control Center. It is to be operational to support Voyager project navigation requirements and is to provide, on a weekly basis, the information related to station clock synchronization, UT1, and polar motion.

Wilcher, J. H.↗

A review of satellite time transfer technology - Accomplishments and future applications

A brief review of the research accomplishments by NASA in meeting the needs of the space program for precise time in satellite tracking is presented. As a major user of precise time signals for clock synchronization of NASA's worldwide satellite tracking networks, the agency provided much of the necessary impetus for the development of stable frequency sources and time synchronization technology. The precision in time required for both satellite tracking and space science experiments has increased at a rate of about 1 order of magnitude per decade from 1 ms in the 1950's to 100 microsec during the Apollo era in the 1960's to 10 microsec in the 1970's. In the 1980's, when the Tracking and Data Relay Satellite System (TDRSS) comes into operation, satellite timing requirements will be extended to 1 microsec and below. These requirements are needed for spacecraft autonomy and data packeting which are now in active planning stages.

Cooper, R. S.↗

Ramp time synchronization

A new method of intercontinental clock synchronization has been developed and proposed for possible use by NASA's Deep Space Network (DSN), using a two-way/three-way radio link with a spacecraft. Analysis of preliminary data indicates that the real-time method has an uncertainty of 0.6 microsec, and it is very likely that further work will decrease the uncertainty. Also, the method is compatible with a variety of nonreal-time analysis techniques, which may reduce the uncertainty down to the tens of nanosecond range.

Hietzke, W.↗

The phase of the ten-hour modulation in the Jovian magnetosphere /Pioneers 10 and 11/

The paper describes the study of the phase of the 10-hour modulation of energetic electrons seen by Pioneers 10 and 11 in the Jovian magnetosphere. Attention is given to the peaks rather than the valleys of each cycle because the peaks are where physically interesting features occur, such as particle acceleration, current sheets, etc. To identify the peaks, it is required that the instantaneous intensity be higher than the 5-hour running average and the 5-hour running average be greater than the 10-hour running average. These criteria select an interval rather than a point and it is determined that this interval is an appropriate estimate of the experimental uncertainty. When the phases of the peaks are plotted together, they create patterns which are discussed in terms of disk-like, clock-like, and rotating anomaly models of the magnetosphere. Each model fits some of the data, but no model explains all of the data convincingly. It is concluded that there is still no understanding of the configuration of the outer Jovian magnetosphere.

Fillius, W.↗

UHF coplanar-slot antenna for aircraft-to-satellite data communications

The initiative for starting the Aircraft-to-Satellite Data Relay (ASDAR) Program came from a recognition that much of the world's weather originates in the data sparse area of the tropics which are primarily ocean. The ASDAR system consists of (1) a data acquisition and control unit to acquire, store and format these data; (2) a clock to time the data sampling and transmission periods; and (3) a transmitter and low-profile upper hemisphere coverage antenna to relay the formatted data via satellite to the National Weather Service ground stations, as shown schematically. The low-profile antenna is a conformal antenna based on the coplanar-slot approach. The antenna is circular polarized and has an on-axis gain of nearly 2.5 dB and a HPBW greater than 90 deg. The discussion covers antenna design, radiation characteristics, flight testing, and system performance.

Myhre, R. W.↗

On the design of a postprocessor for a search for extraterrestrial intelligence /SETI/ system

The design of an on-line postprocessor for a search for extraterrestrial intelligence (SETI) system is described. Signal processing tasks of the postprocessor include: (1) analysis of power level, phase coherence, and state of polarization of single-channel signals in a search for significant signals; (2) grouping or aggregation of adjacent channel data, time averaging of data; and (3) the detection of drifting and modulated signals. Control functions include multichannel spectrum analyzer frequency and clock control, system calibration and selfdiagnostic, control of data flow to and from short-term and long-term (archival) memories, and operation of detection subsystems, such as a visual display and a tunable receiver.

Healy, T. J.↗

Space applications of superconductivity

Some potential applications of superconductivity in space are summarized, e.g., the use of high field magnets for cosmic ray analysis or energy storage and generation, space applications of digital superconducting devices, such as the Josephson switch and, in the future, a superconducting computer. Other superconducting instrumentation which could be used in space includes: low frequency superconducting sensors, microwave and infrared detectors, instruments for gravitational studies, and high-Q cavities for use as stabilizing elements in clocks and oscillators.

Sullivan, D. B.↗

An ultrasonic plethysmograph for space flight applications

The development of an ultrasonic plethysmograph based on the transit time measurement principle is reported, which meets the space-imposed requirements for evaluating cardiovascular deconditioning. It consists of a pulse generator, pulse receiver amplifier, voltage comparator, synchronous pulse generator, elapsed time counter, and transmit and receive piezoelectric crystals resonant at 2 MHz and of 3 mm diameter. The transit time for an ultrasonic pulse to propagate across a limb cross section is computed in a digital fashion using a 32 MHz clock, and resolution is 0.049 mm with the range being approximately 200 mm. Experimental results regarding dynamic system response were found comparable in both accuracy and sensitivity to those of a Whitney strain gage using a 50 torr venous occlusion.

Bhagat, P. K.↗