Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHECK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Study for reducing lung dose of upper thoracic esophageal cancer radiotherapy by auto-planning: volumetric-modulated arc therapy vs intensity-modulated radiation therapy

This study aimed to investigate the dosimetric differences and lung sparing between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) in the treatment of upper thoracic esophageal cancer with T3N0M0 for preoperative radiotherapy by auto-planning (AP). Sixteen patient cases diagnosed with upper thoracic esophageal cancer T3N0M0 for preoperative radiotherapy were retrospectively studied, and 3 plans were generated for each patient: full arc VMAT AP plan with double arcs, partial arc VMAT AP plan with 6 partial arcs, and conventional IMRT AP plan. A simultaneous integrated boost with 2 levels was planned in all patients. Target coverage, organ at risk sparing, treatment parameters including monitor units and treatment time (TT) were evaluated. Wilcoxon signed-rank test was used to check for significant differences (p 20 ), 25 Gy (V{sub 25}), 30 Gy (V{sub 30}), 35 Gy (V{sub 35}), 40 Gy (V{sub 40}), and without increasing the value of V{sub 10}, V{sub 13}, and V{sub 15}. For V{sub 5} of total lung value, pVMAT was similar to aIMRT, and it was better than fVMAT. Both pVMAT and fVMAT improved the target dose coverage and significantly decreased maximum dose for the spinal cord, monitor unit, and TT. No significant difference was observed with respect to V{sub 10} and V{sub 15} of body. VMAT AP plan was a good option for treating upper thoracic esophageal cancer with T3N0M0, especially partial arc VMAT AP plan. It had the potential to effectively reduce lung dose in a shorter TT and with superior target coverage and dose homogeneity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermodynamic investigation of the NaCl-KCl salt system from 25 to 950 °C

NaCl-KCl molten salt system has been proposed as a primary component of several promising heat transfer eutectics and fuel host for Generation IV molten salt reactors (MSR). In this work, several key thermodynamic parameters, including high temperature enthalpies, isobaric heat capacities (C p ) and molar enthalpies of mixing (ΔH mix ), of the NaCl -KCl system (NaCl, 75mol% NaCl – 25mol% KCl, 51mol% NaCl – 49mol% KCl, 25mol% NaCl – 75mol% KCl, and KCl) were measured by high temperature drop calorimetry (HTDC) utilizing laser sealed nickel and aluminum crucibles. Salts were checked for phase purity by X-ray diffraction (XRD), and water content by Karl Fischer coulometric titrimetry and thermogravimetric analysis (TGA). Thermo-mechanical analysis (TMA) utilizing custom-built boron nitride (BN) crucibles was employed to determine temperatures of phase transitions (solid $\rightarrow$ liquid) for the salts and plotted against the pseudobinary phase diagram for the NaCl-KCl system. Small deviations (3-10 %) were found among C p values obtained from HTDC, differential scanning calorimetry (DSC), and NIST, comparable to the average uncertainty based on two standard deviations of measured data that are ~6% for DSC and ~3% for HTDC. Additionally, the measured enthalpies and C p values of mixed NaCl-KCl salts (e.g., 51mol% NaCl – 49mol% KCl eutectic) were shown to behave as statistical mixtures of its pure endmembers, consistent with ΔH mix = ~ 0 kJ/mol at 800 °C, and a regular interaction parameter of Ω = 1.20 ± 0.76 kJ/mol. In conclusion, this study represents a step towards improved accuracy and precision in determinations of thermodynamic parameters of molten salts by using DSC, TMA, and HTDC, in completion of the Molten Salt Thermal Properties Database (MSTDB).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Atlas of Nuclear Isomers

We present an atlas of nuclear isomers containing the experimental data for the isomers with a half-life ≥ 10 ns together with their various properties such as excitation-energy, half-life, decay mode(s), spin-parity, energies and multipolarities of emitted gamma transitions, etc. The ENSDF database complemented by the XUNDL database has been extensively used in extracting the relevant data. Recent literature from primary nuclear physics journals, and the NSR bibliographic database have been searched to ensure that the compiled data Table is as complete and current as possible. The data from NUBASE-12 have also been checked for completeness, but as far as possible original references have been cited. Many interesting systematic features of nuclear isomers emerge, some of them new; these are discussed and presented in various graphs and figures. The cutoff date for the extraction of data from the literature is August 15, 2015.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data Sheets for A = 139

The experimental nuclear spectroscopic data for known nuclides of mass number 139 (Sn, Sb, Te, I, Xe, Cs, Ba, La, Ce, Pr, Nd, Pm, Sm, Eu, Gd, Tb, Dy) have been evaluated and presented together with adopted properties for levels and gamma rays. This evaluation represents a revision of previous one (2001Bu16) by T.W. Burrows. Since then extensive new data have become available for many A=139 nuclides although, no excited state data are yet available for {sup 139}Sn, {sup 139}Sb, {sup 139}Tb, and {sup 139}Dy. The decay schemes of {sup 139}Sn, {sup 139}Sb, {sup 139}I, {sup 139}Tb and {sup 139}Dy nuclei are not known, and those for {sup 139}Gd and {sup 139}Eu are poorly known. Particle-transfer data are available for {sup 139}Ba, {sup 139}La, {sup 139}Ce and {sup 139}Pr. Limited high-spin data are available for {sup 139}Te, {sup 139}I, {sup 139}Cs, {sup 139}Ba, {sup 139}La and {sup 139}Ce, while such data are extensive for {sup 139}Pr, {sup 139}Nd, {sup 139}Pm, {sup 139}Sm, {sup 139}Eu and {sup 139}Gd. Recent {sup 139}Pm high-spin data from two independent studies using the same reaction and similar beam energy are in conflict and could be improved using state-of-the-art large gamma-detector arrays in contrast to the smaller arrays currently used. Cases for which no new experimental information are available since the last update have undergone checking resulting in some changes in the current work, but for the most part these are taken from the previous evaluations. Thus, the present work has greatly benefited from all prior NDS evaluations (2001Bu16, 1989Bu12, 1981Pe04, 1974Gr46), but at the same time data presented herein supersede those in the earlier evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The calorimeter system of the new muon g -2 experiment at Fermilab

The electromagnetic calorimeter for the new muon ( g −2) experiment at Fermilab will consist of arrays of PbF 2 Čerenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here the requirements for this system, the achieved solution and the results obtained from a test beam using 2.0–4.5 GeV electrons with a 28-element prototype array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A search for cosmogenic production of β-neutron emitting radionuclides in water

Here we present the first results of WATCHBOY, a water Cherenkov detector designed to measure the yield of β-neutron emitting radionuclides produced by cosmic ray muons in water. In addition to the β-neutron measurement, we also provide a first look at isolating single-β producing radionuclides following muon-induced hadronic showers as a check of the detection capabilities of WATCHBOY. The data taken over 207 live days indicates a 9 Li production yield upper limit of $1.9\times10^{-7}\mu^{-1}g^{-1}\mathrm{cm}^2$ at $\sim400$ meters water equivalent (m.w.e.) overburden at the 90% confidence level. In this work the 9 Li signal in WATCHBOY was used as a proxy for the combined search for 9 Li and 8 He production. This result will provide a constraint on estimates of antineutrino-like backgrounds in future water-based antineutrino detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quality Assurance methodology for the ATLAS Inner Tracker strip sensor production

The production of the strip sensors for the ATLAS Inner Tracker (ITk) will start in 2020. Nearly 22,000 large area sensors will be produced over a period of about five years by Hamamatsu Photonics K.K. (HPK). The institutes involved in the sensor development and production are committed to deliver and maintain the highest quality sensors for the experiment. A Quality Assurance (QA) strategy has been prepared to be carried out during the whole production period. Once the process has been characterized as providing the required pre-irradiation specifications and the proper radiation hardness, the onus is on the manufacturer to rigidly stick to that qualified process. Still, sample testing with specific device-element structures and irradiation of devices should be implemented by the ITk sensor collaboration. A detailed irradiation and testing plan has been prepared by the ATLAS-ITk Collaboration, together with a newly designed test chip with specific structures to monitor different key technological and device parameters during the whole production. The tests and irradiations will be carried out on a sample basis. In order to have a practical methodology, samples from alternating batches will be sent for irradiations with protons, neutrons and gammas, and then tested in order to check that the characteristics remain within specifications. Here we present the detailed plan and the design and test methods for the structures in the test chip.

47 OTHER INSTRUMENTATION↗

Confirming the absence of nuclear warheads via passive gamma-ray measurements

Arms-control agreements between the United States and Russia negotiated after the end of the Cold War have imposed limits on the number of deployed strategic nuclear weapons. Verification of these agreements has relied on onsite inspections, sometimes supported by radiation detection techniques to confirm the absence of a nuclear warhead when ambiguities arise. So far, these measurements have sought to detect neutron emissions associated with the presence of plutonium, but they would be inadequate for uranium devices. In an effort to offer instruments that could be used to confirm the absence of both plutonium and uranium weapons, here we propose an inspection system that uses only passive gamma radiation detection techniques. Such a system would be particularly valuable for next-generation arms-control agreements that limit total numbers of weapons and would involve containerized items in storage. We conducted extensive Monte Carlo simulations to support the development of a verification protocol and detection algorithm. Here, we demonstrate the viability of the technique using standard laboratory check sources and MCNP simulations for simplified configurations of special nuclear material.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Gaussian mixture model clustering algorithms for the analysis of high-precision mass measurements

The development of the phase-imaging ion-cyclotron resonance (PI-ICR) technique for use in Penning trap mass spectrometry (PTMS) increased the speed and precision with which PTMS experiments can be carried out. In PI-ICR, data sets of the locations of individual ion hits on a detector are created showing how ions cluster together into spots according to their cyclotron frequency. Ideal data sets would consist of a single, 2D-spherical spot with no other noise, but in practice data sets typically contain multiple spots, non-spherical spots, or significant noise, all of which can make determining the locations of spot centers non-trivial. A method for assigning groups of ions to their respective spots and determining the spot centers is therefore essential for further improving precision and confidence in PI-ICR experiments. Here, we present the class of Gaussian mixture model (GMM) clustering algorithms as an optimal solution. We show that on simulated PI-ICR data, several types of GMM clustering algorithms perform better than other clustering algorithms over a variety of typical scenarios encountered in PI-ICR. The mass spectra of 163Gd, 163 mGd, 162 Tb, and 162 mTb measured using PI-ICR at the Canadian Penning trap mass spectrometer were checked using GMMs, producing results that were in close agreement with the previously published values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A stilbene–strontium iodide based radioxenon detection system for monitoring nuclear explosions

Atmospheric measurement of noble gases has been extensively used for monitoring clandestine nuclear weapon explosions for many years. The ratios of four xenon isotopes of interest ( 131 mXe, 133 mXe, 133 Xe, and 135 Xe) help in discriminating regular reactor operations from nuclear tests. A new coincidence-based detection system using stilbene and strontium iodide [SrI 2 (Eu)] for electron and photon detection respectively was developed at Oregon State University to address some of the challenges of the radioxenon systems deployed in the field such as memory effect, and poor energy resolution. Silicon photomultipliers (SiPMs) were used for sensing optical photons from all scintillation media. Real-time coincidence identification was achieved using the eight-channel digital pulse processor. The detection system was evaluated using lab check sources and Oregon State TRIGA reactor irradiated radioxenon samples. A 48-hour background coincidence spectrum was collected yielding a coincidence count rate and background rejection rate of 0.0174 ± 0.0003 counts per second (cps) and 98.9% respectively. The minimum detectable concentration (MDC) of the system was evaluated to be 0.11 ± 0.01, 0.13 ± 0.02, 0.20 ± 0.02, and 0.73 ± 0.08 for 131 mXe, 133 mXe, 133 Xe, and 135 Xe respectively. The memory effect of the detection system was found to be 0.069 ± 0.015%, which is almost a 70-fold reduction compared to traditional plastic scintillators. Here, the detection elements, custom-designed electronics, and the detector response to radioxenon are detailed in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Broadband impedance modeling and single bunch instabilities estimations of the advanced light source upgrade project

We report the Advanced Light Source Upgrade (ALS-U) is a 4th generation diffraction-limited soft x-ray radiation source, consisting of a new accumulator ring (AR) and a new storage ring (SR). In both rings coupling-impedance driven instabilities need careful evaluation to ensure meeting the machine’s high-performance goals. This paper presents the workflow followed in building the impedance models and the beam-stability analysis based on those models. We follow the commonly accepted approach of separating the resistive-wall and the geometric parts of the impedance; the former is obtained by analytical formulas, the latter by numerical electro-magnetic codes (primarily CST Studio software) with perfectly-conducting boundary conditions. Impedance budgets are established and pseudo-Green functions calculated to be used in beam dynamics studies. We also present various ways to cross-check simulation results for reliable impedance modeling. Finally, the crucial single-bunch instability current thresholds for various operation modes are determined and discussed.

07 ISOTOPE AND RADIATION SOURCES↗

Novel X-ray scanning technique for in-situ alignment of photo-detectors in the MEGII calorimeter

Here, we describe and show results of a novel technique to measure with high precision the positions of photodetectors installed in the upgraded liquid xenon calorimeter of the MEG II experiment. The measurement was done by detecting the signal in individual photo-detectors as the front surface of the calorimeter was scanned in axial (Z) and azimuthal (Φ) directions with a precisely controlled, thin, collimated beam of X-rays obtained from a 57 CoX-ray source. The measurements were made when the calorimeter was cold and operational, under which conditions they could not otherwise be made. This technique is used to check for changes in the photodetector positions due to the effects of cooling and thermal cycling of the support structure and to provide a reference between the positions of the operational photodetectors and alignment markers on the cryostat exterior. The use of an essentially monochromatic X-ray source allowed ancillary measurements of photodetector properties, including pulse shape, relative gain, and variation in response over the photodetector surface. Measurement uncertainties below 0.6mm in Z and 0.7 mrad in Φ have been achieved, well within the requirements for the MEG II performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Realistic application of short-lived fission product delayed neutron, gamma-ray analysis for simultaneous nondestructive trace quantification of U, Pu mixtures on cellulose swipes

Detection and characterization of fissile traces are of interest to the international nuclear nonproliferation community, including the International Atomic Energy Agency. Pre-inspection check samples are analyzed by neutron activation analysis at the High Flux Isotope Reactor operated by the Oak Ridge National Laboratory under the umbrella of the IAEA Network of Analytical Laboratories. The simultaneous quantification of U and Pu mixtures was accomplished using the combined delayed neutron (DN) delayed gamma-ray (DG) method to analyze cellulose swipes with actinide loading <1ng in a blind field trial. The total fissile quantity was measured by the DN counts and the relative proportions of U, Pu were determined by calibration of the 104 Tc / 141 Ba fission product count ratio using known mixtures. The DNDG method demonstrated high accuracy in flagging the presence of 239 Pu in uranium down to <100 pg mass loading. In conclusion, peak significance tests helped to control false positive Pu flagging and simultaneous quantification of U and Pu loading was accomplished on samples that passed the significance tests.

36 MATERIALS SCIENCE↗

Use of machine learning for a helium line intensity ratio method in Magnum-PSI

Optical emission spectroscopy (OES) of helium (He) line intensities has been used to measure the electron density, ne, and temperature, Te, in various plasma devices. In this study, a neural network with five hidden layers is introduced to model the relation between the OES data and ne/Te from laser Thomson scattering in the linear plasma device Magnum-PSI and compared to multiple regression analysis. It is shown that the neural network reduces the residual errors of prediction values (ne and Te) less than half those of the multiple regression analysis. We checked two different data splitting methods for training and validation data, i.e., with and without considering the unit of discharge. A comparison of the splitting methods suggests that the residual error will decrease to ~10% even for a new discharge data when accumulating a sufficient data set.

Kajita, Shin↗

A framework for assessment of predictive capability maturity and its application in nuclear thermal hydraulics

Here this work presents a formalized and computerized framework for the assessment of decision regarding the adequacy of a simulation tool for a nuclear reactor application. The decision regarding a code’s adequacy for an application is dependent on the assessment of different attributes that govern verification, validation, and uncertainty quantification of the code. In this work, the focus is on code validation. Therefore, the framework is developed and illustrated from the perspective of decision regarding the validation assessment of a code. Code validation assessment is performed based on the validation test results, data applicability, and process quality assurance factors. The process quality assurance factors warrant the trustworthiness of the evidence and help in checking people and process compliance with respect to the standard requirements. The proposed framework is developed using an argument modeling technique called Goal Structuring Notation (GSN). Goal structuring notation facilitates structural knowledge representation, information abstraction, evidence incorporation, and provides a skeletal structure for quantitative maturity assessment. The decision schema for the development of the decision model is based on the Predictive Capability Maturity Model (PCMM) and Analytic Hierarchy Process (AHP) and formalized using Goal structuring notation. Each decision attribute is formulated as a claim, where the degree of validity of the claim (attribute’s assessment) is expressed using different maturity levels. The GSN representation of the decision model is transformed into a confidence network to provide evidence-based quantitative maturity assessment using the Bayesian network. A metric based on the expected utility of maturity levels, called expected distance metric, is proposed to measure the distance between target maturity and achieved maturity on a scale of zero to one. Expected distance metric helps in comparing the assessment of different attributes and identification of major areas of concern in terms of modeling capability, data needs, and quality of assessment process. The practical application of the framework is demonstrated by a case study on validation assessment of a thermal-hydraulic code for a challenge problem called Departure from Nucleate Boiling (DNB).

42 ENGINEERING↗

Cold nuclear matter effects on J/ψ and Y production in p + Pb collisions at 5 TeV and Pb + Pb collisions at 5.1 TeV

We make a systematic study of the modifications of and production in p+Pb collisions at $\sqrt{s}$$_ {NN}$ = 5 TeV at the LHC. Here, we compare the uncertainties in the EPS09 shadowing parameterization to the calculated mass and scale uncertainties obtained employing the EPS09 NLO central set. We study the dependence of the results on the proton parton density and the choice of the nuclear modifications. We check whether the results obtained are consistent at leading and next-to-leading order. The calculations are compared to the available ALICE and LHCb data on the nuclear modification factors, R pA (y) and R pA (p T ) , as well as the forward-backward asymmetries, R FB (y) and R FB (p T ) . Finally, we make predictions for the next Pb+Pb run at $\sqrt{s}$$_ {NN}$ = 5.1 TeV in Run 2 of the LHC.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A quenched study of the Schroedinger functional with chirally rotated boundary conditions: non-perturbative tuning

The use of chirally rotated boundary conditions provides a formulation of the Schroedinger functional that is compatible with automatic O(a) improvement of Wilson fermions up to O(a) boundary contributions. The elimination of bulk O(a) effects requires the non-perturbative tuning of the critical mass and one additional boundary counterterm. We present the results of such a tuning in a quenched setup for several values of the renormalized gauge coupling, from perturbative to non-perturbative regimes, and for a range of lattice spacings. We also check that the correct boundary conditions and symmetries are restored in the continuum limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗