Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Characterization of tunable electromagnetic band gap material with disordered cavity resonator for X band imaging applications by resistive devices

Electromagnetic band gap (EBG) integrated monopole antenna is investigated in deformed cavity resonator in this study. The operation frequency is chosen as X band frequency regime and designs are completed for this frequency. Firstly, a square grounded monopole antenna is designed and analytically examined, then EBG grounded monopole is designed and tested. After that operation, an 8 cm × 8 cm × 8 cm cubic cavity resonator designed and antennas are examined in it. Moreover, a cuboid deformation is added in one corner of metallic cavity resonator to perturb rectangular eigenmodes. Also, tunability of this structure is tested by various resistive lumped elements, and according to results, resonance shifting and magnitude changes are obtained. This suggested structure is also an adjustable impedance surface and can be used in sensing, detection and microwave imaging applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A proposal for the realization of universal quantum gates via superconducting qubits inside a cavity

A family of quantum logic gates is proposed via superconducting (SC) qubits coupled to a SC-cavity. The Hamiltonian for SC-charge qubits inside a single mode cavity is considered. Three- and two-qubit operations are generated by applying a classical magnetic field with the flux. Therefore, a number of quantum logic gates are realized. Numerical simulations and calculation of the fidelity are used to prove the success of these operations for these gates. -- Highlights: •A family of quantum logic gates is proposed via SC-qubits coupled to a cavity. •Three- and two-qubit operations are generated via a classical field with the flux. •Numerical simulations and calculation of the fidelity are used to prove the success of these operations for these gates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling and Experimental Demonstration of Flux Spreading in Light Trapping Planar-Cavity Solar Enclosed Particle Receivers

This study experimentally validates and numerically models the flux-spreading effect in a light-trapping planar-cavity solar receiver) for particle-based concentrating solar power systems. The receiver's shallow cavity with vertical planar walls redistributes concentrated solar flux, reducing peak intensity and achieving uniform heat flux. On-sun tests at National Renewable Energy Laboratory's High-Flux Solar Furnace under flux up to 1500 kW/m2 measured cavity wall temperatures, which were compared with Monte Carlo ray-tracing (SolTrace) and computational numerical simulations. Three angular absorptance models were evaluated: constant absorptance, a Pyromark-based directional model, and a Fresnel-based Cr2O3 model. The Fresnel-derived model showed the best agreement with experiments, achieving high correlation (PC > 0.85), structural similarity (SSIM > 0.98), and signal-to-noise ratios (PSNR > 40 dB), with temperature prediction errors of 1-11%. Results confirm that flux spreading mitigates local overheating and validate the integrated modeling approach, supporting the solar receiver scalability for high-efficiency, high-temperature concentrating solar power applications.

14 SOLAR ENERGY↗

A novel approach to characterizing the surface topography of niobium superconducting radio frequency (SRF) accelerator cavities

As superconducting niobium radio-frequency (SRF) cavities approach fundamental material limits, there is increased interest in understanding the details of topographical influences on realized performance limitations. Micro- and nano-roughness are implicated in both direct geometrical field enhancements as well as complications of the composition of the 50 nm surface layer in which the super-currents typically flow. Interior surface chemical treatments such as buffered chemical polishing (BCP) and electropolishing (EP) used to remove mechanical damage leave surface topography, including pits and protrusions of varying sharpness. These may promote RF magnetic field entry, locally quenching superconductivity, so as to degrade cavity performance. A more incisive analysis of surface topography than the widely used average roughness is needed. In this study, a power spectral density (PSD) approach based on Fourier analysis of surface topography data acquired by both stylus profilometry and atomic force microscopy (AFM) is introduced to distinguish the scale-dependent smoothing effects, resulting in a novel qualitative and quantitative description of Nb surface topography. The topographical evolution of the Nb surface as a function of different steps of well-controlled EP is discussed. This study will greatly help to identify optimum EP parameter sets for controlled and reproducible surface levelling of Nb for cavity production.

43 PARTICLE ACCELERATORS↗

Tas2r125 functions as the main receptor for detecting bitterness of tea catechins in the oral cavity of mice

Highlights: • We identified mouse 5 bitter taste receptors (Tas2rs) which respond to tea catechin. • Among these receptors, Tas2r125 showed the strongest response to catechins. • The response profiles of Tas2r125 were consistent with the behavior profiles. • Tas2r125 expression was not observed in the tested tissues except the taste papillae. • Tas2r125 plays as the catechin receptor in the oral cavity. We attempted to identify mouse bitter taste receptors, Tas2rs, that respond to tea catechins. Among representative tea catechins, avoidance behavior of mice to (−)–epicatechin gallate (ECg) was the strongest, followed by (−)–epigallocatechin gallate (EGCg). Therefore, we measured ECg response using Tas2rs-expressing cells. Among the 35 members of Tas2r family, Tas2r108, 110, 113, 125, and 144 responded to ECg. Among these receptors, Tas2r113 and 125 also responded to EGCg. Because the response profiles of Tas2r125 were consistent with the results of the behavior assays, it was considered that Tas2r125 functions as the main receptor for detecting bitterness of tea catechins in the oral cavity. To determine the involvement of Tas2rs in the physiological action of catechins, mRNA expression of 5 Tas2rs was investigated in various tissues. Because mRNA expression of Tas2r108 was observed in some tissues including the gastrointestinal tract, it may be envisaged that Tas2r108 plays a part in exerting the physiological action of ECg. Tas2r125 expression was not observed in any of the tested tissues except the circumvallate papillae. Therefore, Tas2r125 was considered to mainly function in the events of catechin reception in the oral cavity.

60 APPLIED LIFE SCIENCES↗

Changes in Excision Cavity Volume: Prediction of the Reduction in Absolute Volume During Breast Irradiation

Purpose: The aim of this study was to determine the changes in the excision cavity volume due to the resolution of the surgical effects during the whole breast treatment. Materials and Methods: Seventy-seven patients with early-stage (T1-2 N0) breast cancer treated with breast-conserving therapy were included for this study. All patients underwent a standard planning computed tomography (CT) scan before irradiation treatment. A second CT scan was performed in the week before the start of the boost. Excision cavity volumes were delineated based on the surgical clips and the (surrounding) seroma or hematoma or other surgical changes on both scans by an experienced physician. This resulted in the gross tumor volumes GTV1 and GTV2. Results: The delineated volumes of the GTVs were on average 78.7 cm{sup 3} (range, 1.1-236.0 cm{sup 3}) and 29.7 cm{sup 3} (range, 1.3-123.6 cm{sup 3}) for, respectively, GTV1 and GTV2. The time between the CT scans was on average 37 days (range, 29-74 days). This resulted in a reduction of on average 62%. The absolute reduction per day of the GTV1 was -1.3 cm{sup 3}/day (range, 0.3 to -5.4 cm{sup 3}/day). A linear correlation (correlation coefficient r{sup 2} = 0.81) was observed between the absolute volume of GTV1 and the absolute reduction per day. Conclusion: A significant reduction in excision cavity volume during whole breast irradiation was shown. The observed correlation might be helpful in the decision to perform a second CT scan to adapt the treatment plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Repeat Computed Tomography Simulation to Assess Lumpectomy Cavity Volume During Whole-Breast Irradiation

Purpose: To determine whether the lumpectomy cavity (LPC) decreases in volume during whole-breast radiotherapy (RT) and what factors influence the decrease. Patients and Methods: Forty-three women with 44 breast lesions were prospectively enrolled. Eligible patients underwent lumpectomy followed by a CT simulation (CT1) within 60 days of surgery. Patients were treated to the entire breast to a dose of 45-50.4 Gy. After 21-23 treatments, a second planning CT simulation (CT2) was done. The LPC was contoured on CT2, and the volumes (LCV) were compared between CT1 and CT2. Results: The median LCV on CT1 and CT2 was 38.2 cm{sup 3} and 21.7 cm{sup 3}, respectively. The median percent change and volume decrease between CT1 and CT2 was -32.0% and 11.2 cm{sup 3}, respectively (n = 44). The LCV decreased in 38 of 44 patients (86%). There was a significant correlation between initial LCV and decrease in volume (p = 0.001) and initial LCV and percent decrease in volume (p < 0.001). There was no correlation between time from surgery to CT1, to start of RT, or to CT2 and change in volume. Conclusions: Patients who undergo lumpectomy almost always have a decrease in their LCV during whole-breast RT. There was a correlation between the initial LCV and decrease in volume on repeat CT simulation. Evaluating patients for this change can potentially lead to decreased doses of radiation to the remaining breast and other critical structures when delivering a small-field boost. Repeat CT simulation should be considered in patients with larger cavities or cavities near critical structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Number of Pathologically Positive Lymph Nodes and Pathological Tumor Depth Predicts Prognosis in Patients With Poorly Differentiated Squamous Cell Carcinoma of the Oral Cavity

Purpose: The objective of this retrospective study was twofold: (1) to investigate prognostic factors for clinical outcomes in patients with poorly differentiated oral cavity squamous cell carcinoma and (2) to identify specific prognostic subgroups that may help to guide treatment decisions. Methods and Materials: We examined 102 patients with poorly differentiated oral cavity squamous cell carcinoma. All patients were followed for at least 24 months after surgery or until death. The 5-year rates of local control, neck control, distant metastasis, disease-free, disease-specific, and overall survival served as main outcome measures. Results: The 5-year rates were as follows: local control (79%), neck control (64%), distant metastases (27%), disease-free survival (48%), disease-specific survival (52%), and overall survival (42%). Multivariable analysis showed that the number of pathologically positive nodes ({>=}4 vs. {<=}3) was a significant predictor of neck control, distant metastasis, and disease-free, disease-specific, and overall survival rates. In addition, the presence of tumor depth of {>=}11 mm (vs. <11 mm) was a significant predictor of distant metastasis, disease-specific survival, and overall survival rates. The combination of the two predictors (26.5%, 27/102) was independently associated with poorer neck control (p = 0.0319), distant metastasis (p < 0.0001), and disease-free (p < 0.0001), disease-specific (p < 0.0001), and overall survival (p < 0.0001) rates. Conclusions: In patients with poorly differentiated oral cavity squamous cell carcinoma, the presence of at least 4 pathologically positive lymph nodes and of a pathological tumor depth {>=}11 mm identifies a subset of subjects with poor clinical outcomes. Patients carrying both risk factors are suitable candidates for the development of novel therapeutic approaches.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patterns of Care in Adjuvant Therapy for Resected Oral Cavity Squamous Cell Cancer in Elderly Patients

Purpose: To characterize the patterns of care and potential barriers to access to care for elderly patients with oral cavity cancer in the adjuvant setting. Methods and Materials: We performed a retrospective cohort study using the National Cancer Data Base and identified patients with resected oral cavity squamous cell carcinoma diagnosed between 2004 and 2012, who survived for ≥3 months after surgery. We used logistic regression models to assess the association between age (<70, 70-79, and ≥80 years) and the receipt of adjuvant therapy within 3 months of surgery. We additionally assessed the association between patient and tumor characteristics and the receipt of adjuvant therapy among those aged ≥70 years. Results: A total of 25,829 patients were included in the study. Compared with those aged <70 years, older patients were more likely to have no neck dissection or have fewer lymph nodes dissected and were less likely to receive adjuvant therapy than younger patients. Among our cohort, 11,361 patients (44%) had pathologic T3-T4 disease or N2-N3 disease, and 4185 patients (16%) had extracapsular nodal extension or positive surgical margins. In multivariate analyses controlling for comorbidity and demographic characteristics, older age was independently associated with lower odds of receiving adjuvant radiation therapy in the subgroup with T3 or T4 disease or N2 or N3 disease and adjuvant chemoradiation therapy in the positive extracapsular nodal extension or positive surgical margin subgroup. Among elderly patients, both greater patient distance from reporting facility and older age were associated with lower odds of receiving both adjuvant radiation therapy (odds ratio 0.66; 95% confidence interval, 0.55-0.81) and chemoradiation therapy (odds ratio 0.56; 95% confidence interval, 0.40-0.79). Conclusions: In a national hospital-based cohort of patients with oral cavity cancer, elderly patients were less likely to receive adjuvant radiation or chemoradiation therapy. Greater patient distance from reporting facility, in addition to older age, was associated with lower odds of receiving both adjuvant radiation therapy and adjuvant chemoradiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing the Risk of Xerostomia and Mandibular Osteoradionecrosis: The Potential Benefits of Intensity Modulated Radiotherapy in Advanced Oral Cavity Carcinoma

Radiation therapy for squamous cell carcinoma of the oral cavity may be curative, but carries a risk of permanent damage to bone, salivary glands, and other soft tissues. We studied the potential of intensity modulated radiotherapy (IMRT) to improve target volume coverage, and normal tissue sparing for advanced oral cavity carcinoma (OCC). Six patients with advanced OCC requiring bilateral irradiation to the oral cavity and neck were studied. Standard 3D conformal radiotherapy (3DCRT) and inverse-planned IMRT dose distributions were compared by using dose-volume histograms. Doses to organs at risk, including spinal cord, parotid glands, and mandible, were assessed as surrogates of radiation toxicity. PTV1 mean dose was 60.8 {+-} 0.8 Gy for 3DCRT and 59.8 {+-} 0.1 Gy for IMRT (p = 0.04). PTV1 dose range was 24.7 {+-} 6 Gy for 3DCRT and 15.3 {+-} 4 Gy for IMRT (p = 0.001). PTV2 mean dose was 54.5 {+-} 0.8 Gy for 3DCRT and for IMRT was 54.2 {+-} 0.2 Gy (p = 0.34). PTV2 dose range was improved by IMRT (7.8 {+-} 3.2 Gy vs. 30.7 {+-} 12.8 Gy, p = 0.006). Homogeneity index (HI) values for PTV2 were closer to unity using IMRT (p = 0.0003). Mean parotid doses were 25.6 {+-} 2.7 Gy for IMRT and 42.0 {+-} 8.8 Gy with 3DCRT (p = 0.002). The parotid V30 in all IMRT plans was <45%. The mandible V50, V55, and V60 were significantly lower for the IMRT plans. Maximum spinal cord and brain stem doses were similar for the 2 techniques. IMRT provided superior target volume dose homogeneity and sparing of organs at risk. The magnitude of reductions in dose to the salivary glands and mandible are likely to translate into reduced incidence of xerostomia and osteoradionecrosis for patients with OCC.

61 RADIATION PROTECTION AND DOSIMETRY↗

HOM identification by bead pulling in the Brookhaven ERL cavity

Several past measurements of the Brookhaven ERL at superconducting temperature produced a long list of higher order modes (HOMs). The Niobium 5-cell cavity is terminated with HOM ferrite dampers that successfully reduce the Q-factors to tolerable levels. However, a number of undamped resonances with Q {ge} 10{sup 6} were found at 4 K and their mode identification remained as a goal for this paper. The approach taken here consists in taking different S{sub 21} measurements on a copper cavity replica of the ERL which can be compared with the actual data and also with Microwave Studio computer simulations. Several different S{sub 21} transmission measurements are used, including those taken from the fundamental input coupler to the pick-up probe across the cavity, between probes in a single cell, and between beam-position monitor probes in the beam tubes. Mode identification is supported by bead pulling with a metallic needle or a dielectric sphere that are calibrated in the fundamental mode. This paper presents results for HOMs in the first two dipole bands with the prototypical 958 MHz trapped mode, the lowest beam tube resonances, and high-Q modes in the first quadrupole band and beyond.

36 MATERIALS SCIENCE↗

A high-finesse Fabry-Perot cavity with a frequency-doubled green laser for precision Compton polarimetry at Jefferson Lab

Here, a high-finesse Fabry-Perot cavity with a frequency-doubled continuous wave green laser (532 nm) has been built and installed in Hall A of Jefferson Lab for high precision Compton polarimetry. The infrared (1064 nm) beam from a ytterbium-doped fiber amplifier seeded by a Nd:YAG nonplanar ring oscillator laser is frequency doubled in a single-pass periodically poled MgO:LiNbO 3 crystal. The maximum achieved green power at 5 W infrared pump power is 1.74 W with a total conversion efficiency of 34.8%. The green beam is injected into the optical resonant cavity and enhanced up to 3.7 kW with a corresponding enhancement of 3800. The polarization transfer function has been measured in order to determine the intra-cavity circular laser polarization within a measurement uncertainty of 0.7%. The PREx experiment at Jefferson Lab used this system for the first time and achieved 1.0% precision in polarization measurements of an electron beam with energy and current of 1.0 GeV and 50 μA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extreme diffusion limited electropolishing of niobium radiofrequency cavities

In this study, a deeply modulated, regular, continuous, oscillating current waveform is reliably and repeatably achieved during electropolishing of niobium single-cell elliptical radiofrequency cavities. Details of the technique and cavity test results are reported here. The method is applicable for cavity frequencies in the range 500 MHz to 3.9 GHz and can be extended to multicell structures.

43 PARTICLE ACCELERATORS↗

Design and operational experience of a microwave cavity axion detector for the 20 – 100 μ eV range

We describe a dark matter axion detector designed, constructed, and operated both as an innovation platform for new cavity and amplifier technologies and as a data pathfinder in the 5-25 GHz range (~20-100 eV). The platform is small but flexible to facilitate the development of new microwave cavity and amplifier concepts in an operational environment. The experiment has recently completed its first data production; it is the first microwave cavity axion search to deploy a Josephson parametric amplifier and a dilution refrigerator to achieve near-quantum limited performance.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RF design of APEX2 two-cell continuous-wave normal conducting photoelectron gun cavity based on multi-objective genetic algorithm

High brightness, high repetition rate electron beams are key components for optimizing the performance of next generation scientific instruments, such as MHz-class X-ray Free Electron Laser (XFEL) and Ultra-fast Electron Diffraction/Microscopy (UED/UEM). In the Advanced Photo-injector EXperiment (APEX)at Berkeley Lab, a photoelectron gun based on a 185.7 MHz normal conducting re-entrant RF cavity, has been proven to be a feasible solution to provide high brightness, high repetition rate electron beam for both XFEL and UED/UEM. Based on the success of APEX, a new electron gun system, named APEX2, has been under development to further improve the electron beam brightness. For APEX2, we have designed a new 162.5 MHz two-cell photoelectron gun and achieved a significant increase on the cathode launching field and the beam exit energy. For a fixed charge per bunch, these improvements will allow for the emittance reduction and hence to an increased beam brightness. The design of APEX2 gun cavity is a complex problem with multiple design goals and restrictions, some even competing each other. In conclusion, for a systematic and comprehensive search for the optimized cavity geometry, we have developed and implemented a novel optimization method based on the Multi-Objective Genetic Algorithm (MOGA).

47 OTHER INSTRUMENTATION↗

Distinctive Trend of Metal Binding Affinity via Hydration Shell Breakage in Nanoconfined Cavity

Here, we report a distinctive trend in the binding affinity of metal cations when they interact with lacunary Keggin-type polyoxometalate K 7 [α-PW 11 O 39 ] clusters in aqueous media. The binding affinity of metal cations follows the special trends of Li + > Na + > K + for monovalent cations and Mg 2+ > Ca 2+ > Sr 2+ > Ba 2+ for divalent cations, completely reversed from the common trends of Li + < Na + < K + and Mg 2+ < Ca 2+ < Sr 2+ < Ba 2+ for macroion–counterion ion-pair formation in dilution solution. Isothermal titration calorimetry and NMR measurements confirm that the hydration shells of metal cations are significantly broken during the interaction in the nanoscale cavity, making the binding affinity stronger for the cations with smaller ionic sizes instead of hydrated sizes. Furthermore, the same phenomenon is observed for the lacunary Dawson-type clusters, which contain well-defined cavity in their structures as well, demonstrating the universality of this reverse trend and its connection to nanoconfinement effect in small submolecular cavities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Resonant Cavity in a Nanotaper

The present study describes an optical resonant cavity in a nanotaper with scale reduction from micro to several nanometers. Both experimental results and a finite-difference time-domain (FDTD)-based simulation suggested that the nanometer-scale taper with a diameter similar to the wavelength of light acted as a mirror, which facilitated the formation of a laser cavity and caused lasing in ZnO nanotapers. As the light inside the nanotaper propagated toward the apex, the lateral mode was reduced and reflection occurred. This report suggests that use of the resonant optical cavities in nanotapers might result in novel active and passive optical components, which will broaden the horizons of photonic technology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Tunneling study of cavity grade Nb : possible magnetic scattering at the surface.

Tunneling spectroscopy was performed on Nb pieces prepared by the same processes used to etch and clean superconducting radio frequency (SRF) cavities. Air exposed, electropolished Nb exhibited a surface superconducting gap {Delta} = 1.55 meV, which is characteristic of a clean, bulk Nb. However, the tunneling density of states (DOS) was significantly broadened. The Nb pieces, which were treated with the same mild baking used to improve the Q slope in SRF cavities, reveal a sharper DOS. Good fits to the DOS were obtained by using the Shiba theory, suggesting that magnetic scattering of quasiparticles is the origin of the gapless surface superconductivity and a heretofore unrecognized contributor to the Q-slope problem of Nb SRF cavities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗