Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Optical Navigation Attitude Estimation and Calibration Performance Improvement using Outlier Rejection

Spacecraft optical navigation (OpNav) systems process a sequence of images of celestial bodies against a starfield background to estimate the position and velocity of the vehicle. While attitude is sometimes available from an onboard star tracker, it is often desirable to recognize the background stars in the OpNav images to better align the image. While many image processing algorithms exist for finding stars, efficiency and reliability remain key issues in the presence of extended bodies(e.g. the Moon, Earth), especially when attempting to solve the full lost-in-space problem. Some star outliers(stars identified with high residuals)could appear in the camera field of view, however using them in the attitude estimation or camera calibration would lead to less accurate results. Therefore, we require new and robust approaches to remove these outliers before any further processing. The emphasis of the work is on developing a simple and robust iterative technique to detect and reject the outliers which could be found in any frame during the lost in space attitude determination or during the camera calibration. These outliers are determined based on the residuals of the centroids of the detected stars and the corresponding location using the star catalog. If the residuals exceed a predetermined threshold value, the object will be detected as an outlier and will be removed before another attitude determination and calibration iteration is performed. The performance for both attitude determination and on-orbit camera calibration are improved by an almost two-fold increase in accuracy when applying this outlier rejection technique.

OpNav↗

Vicarious Calibration of the Long Near Infrared Band: Cross-Sensor Differences in Sensitivity

Numerous assumptions and approximations are employed when translating satellite-derived radiance to surface remote sensing reflectance (RRS) for ocean color applications. Among these is the vicarious calibration coefficient (g) of the ‘long’ near infrared band (NIRL) used for atmospheric correction. For this band, the pre-launch calibration has always been deemed sufficient [thus g(NIRL) = 1.00] as long as other bands are vicariously calibrated. Recent research, however, suggests that MODIS/Aqua RRS time series are quite sensitive to g(NIRL) (and associated vicarious gains in other bands). In this work, we assessed the sensitivity of VIIRS/SNPP RRS to NIRL calibration, and compared our results to previous MODIS/Aqua and SeaWiFS/OrbView2 analysis. In doing so, we note g(NIRL) sensitivities of mission-averaged RRS timeseries are lower for VIIRS and SeaWiFS, relative to MODIS. At the scale of monthly climatologies, however, all sensors show prominent g(NIRL) sensitivity, with that of SeaWiFS being the most substantial. These findings informed simulation analyses, whereby we identified signal-to-noise ratio (SNR) and radiant path geometry, as well as their interaction, as having notable impacts on g(NIRL) sensitivity. As such, g(NIRL) sensitivity is a necessary consideration for reflectance uncertainty budgets, especially for sensors with higher NIR SNR or particular prevailing radiant path geometries. Given the geometry components embedded within g(NIRL) sensitivity, such studies should be coupled with cross-sensor intercalibrations (e.g., using simultaneous same view measurements) toward minimizing NIRL errors between satellite instruments, but such efforts will not completely remediate remaining cross-sensor biases in RRS.

Brian B Barnes↗

Using DSCOVR EPIC as a Transfer Radiometer to Scale Leo Imagers to the Same Calibration Reference

The NASA CERES project provides climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 low earth orbiting (LEO) satellites, where they are used in tandem with the MODIS and VIIRS instruments to retrieve cloud properties required for converting CERES radiance observations into fluxes. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua-MODIS reference to retrieve consistent imager cloud properties between sensors. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun-synchronous orbit but spaced equally apart, allowing for no simultaneous nadir overpasses (SNO) to inter-calibrate the VIIRS imagers to each other. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between neither MODIS nor VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers. The study will demonstrate the use of EPIC to radiometrically scale VIIRS and MODIS imagers to the same Aqua-MODIS calibration reference. The EPIC-based NPP and N20-VIIRS scaling factors will be compared with the Aqua-MODIS based NPP and N20-VIIRS scaling factors.

C. O. Haney↗

SMAP Calibration Using Cold Sky Observations

Cold Sky Calibration is an important tool in the calibration of the SMAP radiometer. It is used to assess the absolute calibration and its temporal drift. We will present the results of 7 years of cold sky observations and the latest improvements they provide to the analysis of the SMAP radiometer calibration performances.

Emmanuel P Dinnat↗

In Pursuit of CFD-based Wind Tunnel Calibrations

Computational fluid dynamic simulations of models tested in wind tunnels require a high level of fidelity and accuracy, particularly for the purposes of CFD validation efforts. Considerable effort is required to ensure a sufficient characterization of both the physical geometry of the wind tunnel, the thermodynamics of the tunnel, and flow conditions in the test section. The condition setting process among subsonic wind tunnels, closed or open throat, is generally the same, though they can differ in specific details of the thermodynamics. The derivation, application, and error estimation of condition setting and calibration is discussed. Computational flow solutions of the high-speed leg of the NASA Langley Research Center 14- by 22-Foot Subsonic Tunnel are used to evaluate the calibration process and discuss calibration curve sensitivities. Duplicating the characteristics of a particular wind tunnel is difficult at best. A calibration curve derived from the computational method is the most consistent method to use for tunnel condition setting.

wind tunnel↗

Consistent Pixel Resolution Characterization of Deep Convective Clouds for Calibration

The NASA CERES project provides global TOA shortwave and longwave fluxes for climate monitoring and validation that spans over 20 years. CERES utilizes broadband fluxes derived from geostationary (GEO) imagers to estimate broadband fluxes between the CERES observations. In order for these fluxes to be viable, the GEO imager calibration must be stable over time. One such calibration method used by CERES is to evaluate ensemble sets of deep convective clouds (DCC) as invariant targets (IT) over time. DCC targets can also provide radiometric scaling between sensors. An international collaboration through GSICS is also evaluating the DCC-IT calibration methodology to provide consistent calibration coefficients across geostationary sensors. Tropical DCC are the coldest, brightest, and most Lambertian TOA Earth targets identified using a window channel brightness temperature threshold. The DCC-IT technique involves a large ensemble of TOA pixel-level reflectances, which are binned into probability density functions (PDF). The PDF structure dependency on sensor pixel resolution, which can vary greatly among sensors, is not well known. This study will identify the impact of pixel resolution on the DCC PDFs by aggregating VIIRS and Landsat OLI/TIRS pixel resolutions into various coarser pixel resolutions and comparing the shape and statistics of the resulting PDFs. This study should assist in mitigating the pixel resolution dependency in the DCC-IT approach for providing scaling factors between sensors.

Conor Haney↗

PACE OCI Calibration and Geolocation Operational Algorithm Description

This technical report describes the software implementation of the calibration and geolocation processing algorithms for the Ocean Color Instrument (OCI) on the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission. PACE was launched on February 8, 2024. The first Earth-viewing data were collected on February 25, and commissioning was completed on April 5. All PACE science data are acquired and processed by the Science Data Segment (SDS). The first processing stages are Level 0-to-1A and Level 1A-to-1B. The calibration and geolocation processing is performed during the latter stage. The L1B products are the inputs for geophysical retrieval processing (Level 2). This report is organized as follows. The pertinent characteristics of OCI for calibration and geolocation processing are described in Section II. Section III describes the implementation of the geolocation processing algorithms, and the calibration processing is described in Section IV. The Level 1B product format is described in Section V.

Ivona Cetinic↗

Pre-Launch Calibration and Validation of the Airborne Hyper-Angular Rainbow Polarimeter (AirHARP) Instrument

The Airborne Hyper-Angular Rainbow Polarimeter (AirHARP) is a new imaging polarimeter instrument capable of sampling a single Earth target from up to 120 viewing angles, in four spectral channels, and in three linear polarization states across a 114° field of view (FOV). AirHARP is telecentric in the image space and simultaneously images three linear polarization states with no moving parts. These two aspects of the design allow for a simple and efficient quantitative calibration. Using coefficients derived at the center of the lens and the detector flatfields, we can calibrate the entire AirHARP sensor in a variety of laboratory, field, and space environments. We show that this telecentric calibration technique yields a 1σ absolute uncertainty of 0.25 % in degree of linear polarization (DOLP) in the laboratory for all channels and for pixels around the optical axis. To validate across the FOV, we compare our multi-angle reflectance and polarization data with the Research Scanning Polarimeter (RSP) over targets sampled during the NASA Aerosol Characterization from Polarimeter and Lidar (ACEPOL) campaign. We use the error-normalized difference technique to estimate how well the instruments compare relative to their error models. We find that AirHARP and the RSP reasonably agree for reflectance and DOLP within 2 standard deviations of their mutual uncertainty at 550, 670, and 870 nm and over a limited set of ocean and desert scenes. This calibration technique makes the Hyper-Angular Rainbow Polarimeter (HARP) design attractive for new spaceborne climate missions: HARP CubeSat (2020–2022), HARP2 (2024–) on the NASA Plankton, Aerosol, Cloud, ocean Ecosystem (PACE), and beyond.

Airborne Hyper-Angular Rainbow Polarimeter↗

Experimental Calibration of Flow Rule Coefficients for LS-Dyna Mat_213

Composite materials have become a popular choice in aerospace engineering applications due to their low weight, high specific stiffness, high specific energy absorption, and economic synthesis. As use of composite materials has proliferated, the need for accurate simulation under extreme loading conditions is of increasing importance. *MAT_213 is a tabulated plasticity and damage material model in LS-DYNA designed for such use cases. To account for the nonlinear material response, a plasticity algorithm is used, which employs a non-associative flow rule with coefficients requiring experimental calibration. This work outlines an experimental methodology for calibrating these coefficients using the macroscopic stress-strain response and microscopic in-plane strain measurements from coupon scale experiments. The model material used for the development and demonstration of this methodology is a plain weave woven fabric with T300 carbon fiber tows in the warp direction and Kevlar© 49 fiber tows in the weft direction, and an Epon© 828/Epikure© 3223 thermoset epoxy matrix. Coupon-scale tensile testing performed at multiple fiber angles (carbon fibers oriented 0º, 22.5º, 45º, 67.5º, and 90º relative to the loading axis) provides data for multiple calibration processes. The measured plastic strain increments in the principal material coordinate are used to set limits for ratios between flow rule coefficients. The identified ranges are used to bound the search for a set of coefficients, leading to convergence of different coupon responses in the effective stress – effective plastic strain space. Flow rule coefficients found by this methodology are then used as (i) input for LS-DYNA simulations of uniaxial tension coupon tests at varying fiber angles, and (ii) comparison of predicted values for the plastic Poisson’s ratio in global coordinates with the experimentally measured one for all off-axis orientations. These results are quantitatively and qualitatively compared to macroscopic stress-strain curves and experimental strain components. The conformity of the experimentally measured quantities with those derived from the simulations provide a means for assessing the quality of calibrated coefficients.

Polymer Matrix Composites↗

Camera Calibration and Alignment Metrology at Johnson Space Center’s Electro-Optics Laboratory

It is increasingly common to see spacecraft equipped with cameras for the purpose of navigation. Images are either sent to Earth or processed autonomously on-board to provide information about the vehicle’s position, velocity, and/or attitude. These can be images of stars or celestial bodies for absolute navigation, or images of another spacecraft for relative navigation. While monocular cameras do not provide range information, the images they capture can be processed to determine bearing vectors to target objects within the camera’s field of view. For a camera to be effective in navigation, it must be carefully calibrated and aligned. This involves accurately modeling the optical effects that govern the projection of line-of-sight directions onto the camera’s pixels and determining the camera’s orientation relative to the spacecraft’s reference frame. Engineers at Johnson Space Center’s Electro-Optics Lab regularly perform camera inspection, calibration, and alignment metrology. This was done for the Orion Optical Navigation (OpNav) Camera, the Orion Docking Camera (DCAM), and for numerous cameras belonging to commercial partners. The nature of optical navigation means that cameras must be well-calibrated and their attitude well understood to provide high accuracy bearing measurements to the navigation filter. The stringent accuracy requirements for Orion could not have been met using traditional checkerboard camera calibration or by simply relying on design drawings. This paper details the hardware, software, techniques, and algorithms used by the EOL team to achieve this level of accuracy.

Paul D Mckee↗

Camera Calibration and Alignment Metrology at Johnson Space Center’s Electro-Optics Laboratory

It is increasingly common to see spacecraft equipped with cameras for the purpose of navigation. Images are either sent to Earth or processed autonomously on-board to provide information about the vehicle’s position, velocity, and/or attitude. These can be images of stars or celestial bodies for absolute navigation, or images of another spacecraft for relative navigation. While monocular cameras do not provide range information, the images they capture can be processed to determine bearing vectors to target objects within the camera’s field of view. For a camera to be effective in navigation, it must be carefully calibrated and aligned. This involves accurately modeling the optical effects that govern the projection of line-of-sight directions onto the camera’s pixels and determining the camera’s orientation relative to the spacecraft’s reference frame. Engineers at Johnson Space Center’s Electro-Optics Lab regularly perform camera inspection, calibration, and alignment metrology. This was done for the Orion Optical Navigation (OpNav) Camera, the Orion Docking Camera (DCAM), and for numerous cameras belonging to commercial partners. The nature of optical navigation means that cameras must be well-calibrated and their attitude well understood to provide high accuracy bearing measurements to the navigation filter. The stringent accuracy requirements for Orion could not have been met using traditional checkerboard camera calibration or by simply relying on design drawings. This paper details the hardware, software, techniques, and algorithms used by the EOL team to achieve this level of accuracy.

Paul McKee↗

An Eigenvector-based Method of Radio Array Calibration and Its Application to the Tianlai Cylinder Pathfinder

We propose an eigenvector-based formalism for the calibration of radio interferometer arrays. In the presence of a strong dominant point source, the complex gains of the array can be obtained by taking the first eigenvector of the visibility matrix. We use the stable principle component analysis (SPCA) method to help separate outliers and noise from the calibrator signal to improve the performance of the method. This method can be applied with poorly known beam model of the antenna, and is insensitive to outliers or imperfections in the data, and has low computational complexity. It thus is particularly suitable for the initial calibration of the array, which can serve as the initial point for more accurate calibrations. We demonstrate this method by applying it to the cylinder pathfinder of the Tianlai experiment, which aims to measure the dark energy equation of state using the baryon acoustic oscillation (BAO) features in the large scale structure by making intensity mapping observation of the redshifted 21~cm emission of the neutral hydrogen (HI). The complex gain of the array elements and the beam profile in the East-West direction (short axis of the cylinder) are successfully obtained by applying this method to the transit data of bright radio sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method and system for calibrating gamma radiation flux levels in a solid state gamma radiation detection system

One aspect of the present disclosure comprises a method for calibrating a drive level of a non-radioactive calibration source. Another aspect of the present disclosure comprises a method for using a non-radioactive calibration source to verify correct operation of a radiation detector. Another aspect of the present disclosure comprises a radiation detection system that comprises a radiation detector and a non-radioactive calibration source that is used to verify correct operation of the radiation detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of temperature adaptive calibration methods for laser induced fluorescence based fuel-in-oil instrument

Fuel dilution of engine oil (or fuel-in-oil, FiO) is an important issue as multiple and late-cycle fuel injection, integral to many combustion efficiency and emissions improvements (e.g., downsized boosted gasoline engines and catalyst thermal management) increases FiO rate. In addition to causing general wear and corrosion in engine due to decreased oil viscosity and pH buffering, FiO is also believed to cause destructive low speed pre-ignition (or super knock) in boosted SI engines. To understand the effects of engine operating conditions on the FiO rate, an optical diagnostic capable of measuring transient FiO on minute timescales was recently developed and demonstrated on a modified GM Ecotech engine system (Neupane et al., Applied Spectroscopy 2021). The measurement is based on adding a dye to the fuel and monitoring for its presence in oil via laser-induced fluorescence (LIF). The measured LIF signal is related to FiO concentration via pre-determined calibration factors using a multivariate classical least square (CLS) method.Since fluorescence quantum yield is a function of temperature, measured LIF intensity not only depends on FiO concentration but also oil temperature. To expand the applicability of the FiO diagnostic to transient oil-temperature conditions (e.g., cold start in practical engines), this study develops a method to account for oil-temperature variations. The effect of oil temperature (20°C - 95°C) on the LIF spectra of eight FiO samples ranging from ~0.8-15% was investigated. LIF intensities of the FiO samples decreased linearly with increasing temperature; the reductions being more significant at dye peaks. We develop a new calibration model (T-adaptive CLS) incorporating the temperature (T) effects on LIF intensity that enables simultaneous calculation of FiO and oil temperature. The improved FiO diagnostic with T-adaptive calibration is more robust, and applicable to varying oil-temperature conditions. For example, when strategies such as multiple/late fuel injections are applied to overcome cold-start instability due to use of low vaporization bio-based fuels such as ethanol, FiO rate is expected to be very high; the improved T-adaptive FiO diagnostic is hence relevant for engine- and fuel-system calibration and optimization. The diagnostic could also provide validation data for flow-field and spray interaction CFD models, further broadening the diagnostic’s utility for advancing engine technology and efficiency.

Neupane, Sneha↗

Calibration method for a spectral computerized tomography system

A calibration method for an x-ray computerized tomography system and a method of tomographic reconstruction are provided. The calibration method includes steps of measuring at least one point spread function (PSF) at each of a plurality of points, compressing each PSF, and in one or more storing operations, storing the compressed PSFs in a computer-accessible storage medium. The PSF measurements are made in a grid of calibration points in a field of view (FOV) of the system. In the measuring step, an absorber is positioned at each of the calibration points, and an x-ray projection is taken at least once at each of those absorber positions. In the method of tomographic image reconstruction, projection data from an x-ray tomographic projection system are input to an iterative image reconstruction algorithm. The algorithm retrieves and utilizes a priori system information (APSI) The APSI comprises comprising point spread functions (PSFs) of all voxels in a voxelization of the field of view that are compressed in the form of vectors of parameters. For utilization, each retrieved vector of parameters is decompressed so as to generate a discretized PSF.

Jimenez, Jr., Edward Steven↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 w/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 w/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky night monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs and CG4 was calculated using NREL equation. The calculated uncertainty (U95) of the PIRs varied from 2.43 w/m2 to 2.67 w/m2 , and for the CG4 equals 1.97 w/m2 with respect to SI.

absolute cavity pyrgeometer↗

QCalEval: Benchmarking Vision-Language Models for Quantum Calibration Plot Understanding

Quantum computing calibration depends on interpreting experimental data, and calibration plots provide the most universal human-readable representation for this task, yet no systematic evaluation exists of how well vision-language models (VLMs) interpret them. We introduce QCalEval, the first VLM benchmark for quantum calibration plots: 243 samples across 87 scenario types from 22 experiment families, spanning superconducting qubits and neutral atoms, evaluated on six question types in both zero-shot and in-context learning settings. The best general-purpose zero-shot model reaches a mean score of 72.3, and many open-weight models degrade under multi-image in-context learning, whereas frontier closed models improve substantially. A supervised fine-tuning ablation at the 9-billion-parameter scale shows that SFT improves zero-shot performance but cannot close the multimodal in-context learning gap. As a reference case study, we release NVIDIA Ising Calibration 1, an open-weight model based on Qwen3.5-35B-A3B that reaches 74.7 zero-shot average score.

Cao, Shuxiang↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗