Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Build System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Comparison of Second Wind Triton Data with Meteorological Tower Measurements

With the increased interest in remote sensing of wind information in recent years, it is important to determine the reliability and accuracy of new wind measurement technologies if they are to replace or supplement conventional tower-based measurements. In this study, we present the results of an analysis characterizing the measurement performance of a state-of-the-art SOund Detection And Ranging (sodar) device when compared to a high-quality tower measurement program. Second Wind Inc. (Somerville, MA, USA) provided NREL with more than six months of data from a measurement program conducted near an operating wind farm in western Texas.

17 WIND ENERGY↗

Nebraska Statewide Wind Integration Study: Executive Summary

Wind generation resources in Nebraska will play an increasingly important role in the environmental and energy security solutions for the state and the nation. In this context, the Nebraska Power Association conducted a state-wide wind integration study.

17 WIND ENERGY↗

Assessment of Offshore Wind Energy Resources for the United States

This report summarizes the offshore wind resource potential for the contiguous United States and Hawaii as of May 2009. The development of this assessment has evolved over multiple stages as new regional meso-scale assessments became available, new validation data was obtained, and better modeling capabilities were implemented. It is expected that further updates to the current assessment will be made in future reports.

17 WIND ENERGY↗

Parabolic Trough Reference Plant for Cost Modeling with the Solar Advisor Model (SAM)

This report describes a component-based cost model developed for parabolic trough solar power plants. The cost model was developed by the National Renewable Energy Laboratory (NREL), assisted by WorleyParsons Group Inc., for use with NREL's Solar Advisor Model (SAM). This report includes an overview and explanation of the model, two summary contract reports from WorleyParsons, and an Excel spreadsheet for use with SAM. The cost study uses a reference plant with a 100-MWe capacity and six hours of thermal energy storage. Wet-cooling and dry-cooling configurations are considered. The spreadsheet includes capital and operating cost by component to allow users to estimate the impact of changes in component costs.

14 SOLAR ENERGY↗

Building Energy Simulation Test for Existing Homes (BESTEST-EX); Phase 1 Test Procedure: Building Thermal Fabric Cases

The U.S. Department of Energy tasked NREL to develop a process for testing the reliability of models that predict retrofit energy savings, including their associated calibration methods. DOE asked NREL to conduct the work in phases so that a test procedure would be ready should DOE need it to meet legislative requirements related to residential retrofits in FY 2010. This report documents the initial 'Phase 1' test procedure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Renewable Energy Laboratory, South Table Mountain Campus, Golden, Colorado

The National Renewable Energy Laboratory (NREL) South Table Mountain campus, located in Golden, Colorado, has multiyear datasets from buildings with approximately 1,100,000 sq ft of floor area. These 16 buildings include a large office, nine laboratories, and other education or public assembly facilities such as an education center, a warehouse, quick service restaurants, two site entrance security buildings, and a parking garage—all constructed and improved from 1982 to 2014. These datasets are also available from the NREL data storage and management platform SkySparks. The datasets contain electricity meter data (poser, voltage, and current) with 1-minute resolution and building automation system (BAS) data with resolutions of 5 or 15 minutes. Some subsystems (e.g., lighting) or equipment electricity data have the same intervals as above. Some mechanical equipment state or condition data, such as flow and temperature, are captured with 5- to 15-minute intervals. The types of measurement points (i.e., electrical meter power and zone temperature) and associated data quality across the campus are typical, which helps reduce the unreliability of data quality.

STM, Systems and equipment operational, Energy use↗

Endpoint Use Efficiency Comparison for AC and DC Power Distribution in Commercial Buildings

Advances in power electronics and their use in Miscellaneous Electric Loads (MELs) in buildings have resulted in increased interest in using low-voltage direct current (DC) power distribution as a replacement for the standard alternating current (AC) power distribution in buildings. Both systems require an endpoint converter to convert the distribution system voltage to the MELs voltage requirements. This study focused on the efficiency of these endpoint converters by testing pairs of AC/DC and DC/DC power converters powering the same load profile. In contrast to prior studies, which estimated losses based on data sheet efficiency and rated loads, in this study, we used part load data derived from real-world time-series load measurements of MELs and experimentally characterized efficiency curves for all converters. The measurements performed for this study showed no systematic efficiency advantage for commercially available DC/DC endpoint converters relative to comparable, commercially available AC/DC endpoint converters. For the eight appliances analyzed with the pair of converters tested, in 50%, the weighted energy efficiency of the DC/DC converter was higher, while, for the other 50%, the AC/DC converter was. Additionally, the measurements indicated that the common assumption of using either data sheet efficiency values or efficiency at full load may result in substantial mis-estimates of the system efficiency.

AC/DC converters↗

Data-driven Identification of Occupant Thermostat-Behavior Dynamics

Building occupant behavior drives significant differences in building energy use, even in automated buildings. Users’ distrust in the automation causes them to override settings. This results in responses that fail to satisfy both the occupants’ and/or the building automation’s objectives. The transition toward grid-interactive efficient buildings will make this evermore important as complex building control systems optimize not only for comfort, but also changing electricity costs. This paper presents a data-driven approach to study thermal comfort behavior dynamics which are not captured by standard steady-state comfort models such as predicted mean vote. The proposed model captures the time it takes for a user to override a thermostat setpoint change as a function of the manual setpoint change magnitude. The model was trained with the ecobee Donate Your Data dataset of 5 min. resolution data from 27,764 smart thermostats and occupancy sensors. The resulting population-level model shows that, on average, a 2°F override will occur after ~30 mins. and an 8°F override will occur in only ~15 mins., indicating the magnitude of discomfort as a key driver to the swiftness of an override. Such models could improve demand response programs through personalized controls.

Kane, Michael↗

The MESSy aerosol submodel MADE3 (v2.0b): description and a box model test

We introduce MADE3 (Modal Aerosol Dynamics model for Europe, adapted for global applications, 3rd generation; version: MADE3v2.0b), an aerosol dynamics submodel for application within the MESSy framework (Modular Earth Submodel System). MADE3 builds on the predecessor aerosol submodels MADE and MADE-in. Its main new features are the explicit representation of coarse mode particle interactions both with other particles and with condensable gases, and the inclusion of hydrochloric acid (HCl) / chloride (Cl) partitioning between the gas and condensed phases. The aerosol size distribution is represented in the new submodel as a superposition of nine lognormal modes: one for fully soluble particles, one for insoluble particles, and one for mixed particles in each of three size ranges (Aitken, accumulation, and coarse mode size ranges). In order to assess the performance of MADE3 we compare it to its predecessor MADE and to the much more detailed particle-resolved aerosol model PartMC-MOSAIC in a box model simulation of an idealised marine boundary layer test case. MADE3 and MADE results are very similar, except in the coarse mode, where the aerosol is dominated by sea spray particles. Cl is reduced in MADE3 with respect to MADE due to the HCl / Cl partitioning that leads to Cl removal from the sea spray aerosol in our test case. Additionally, the aerosol nitrate concentration is higher in MADE3 due to the condensation of nitric acid on coarse mode particles. MADE3 and PartMC-MOSAIC show substantial differences in the fine particle size distributions (sizes ≲ 2 μm) that could be relevant when simulating climate effects on a global scale. Nevertheless, the agreement between MADE3 and PartMC-MOSAIC is very good when it comes to coarse particle size distributions (sizes ≳ 2 μm), and also in terms of aerosol composition. Finally, considering these results and the well-established ability of MADE in reproducing observed aerosol loadings and composition, MADE3 seems suitable for application within a global model.

Kaiser, J. C.↗

OccuTherm: Occupant Thermal Comfort Inference using Body Shape Information

This repository contains the official data from a USDOE-funded project at Carnegie Mellon University and Bosch Research Pittsburgh. The primary goal of the project was to investigate the relationship between indoor commercial building occupant thermal comfort and various biometric and environmental predictors. We performed 77 individual comfort experiments, approved by our Institutional Review Board (IRB) and in satisfaction of participant consent guidelines. Our goal was to generate a dataset than enables comprehensive study of human thermal comfort preferences, in a commercial building environment, across a wide range of indoor environmental conditions. The data is comprised of the following feature groups: depth camera frames, biometrics sensor data, body shape information, subjective comfort data from the mobile device application, environmental sensor data from the commercial building HVAC system, and outdoor weather station data.

47 OTHER INSTRUMENTATION↗