Numerical analysis of flow in the hot gas manifold of the Space Shuttle main engine

This paper presents a numerical model and results of analyses carried out to characterize the flow through the two duct configuration of the Hot Gas Manifold of the Space Shuttle Main Engine. Three dimensional computations have been performed for a half-scale air test model using a nonorthogonal body-fitted coordinate system. The calculation domain is extended from the inlet of the turnaround duct to the exit of the transfer duct. Three test cases, one for laminar flow and two for turbulent flow, have been considered. For turbulent flows, constant eddy viscosity and the k-epsilon model of turbulence were employed. As expected, laminar flow calculation predicts much larger pressure drop than turbulent flow cases. The turbulent flow results are in good agreement with the available flow-visualization data. This study and experimental data indicate that the two-transfer duct design will significantly improve the flow distribution in the Hot Gas Manifold and thereby enhance the overall performance of the SSME.

Owens, S. F.↗

Analysis of Raman Lidar and radiosonde measurements from the AWEX-G field campaign and its relation to Aqua validation

Early work within the Aqua validation activity revealed there to be large differences in water vapor measurement accuracy among the various technologies in use for providing validation data. The validation measurements were made at globally distributed sites making it difficult to isolate the sources of the apparent measurement differences among the various sensors, which included both Raman lidar and radiosonde. Because of this, the AIRS Water Vapor Experiment-Ground (AWEX-G) was held in October - November, 2003 with the goal of bringing validation technologies to a common site for intercomparison and resolution of the measurement discrepancies. Using the University of Colorado Cryogenic Frostpoint Hygrometer (CFH) as the water vapor reference, the AWEX-G field campaign resulted in new correction techniques for both Raman lidar, Vaisala RS80-H and RS90/92 measurements that significantly improve the absolute accuracy of those measurement systems particularly in the upper troposphere. Mean comparisons of radiosondes and lidar are performed demonstrating agreement between corrected sensors and the CFH to generally within 5% thereby providing data of sufficient accuracy for Aqua validation purposes. Examples of the use of the correction techniques in radiance and retrieval comparisons are provided and discussed.

Whiteman, D. N.↗

Radiative Energetics of Mineral Dust Aerosols from Ground-Based Measurements

Airborne dust aerosols worldwide contribute a significant part to air quality problems and, to some extent, regional climatic issues (e.g., radiative forcing, hydrological cycle, and primary biological productivity in oceans). Evaluating the direct solar radiative effect of dust aerosols is relatively straightforward due in part to the relatively large SIN ratio in broadband irradiance measurements. The longwave (LW) impact, on the other hand, is rather difficult to ascertain since the measured dust signal level (approx.10 W/sq m) is on the same order as the instrumental uncertainties. Although the magnitude of the LW impact is much smaller than that of the shortwave (SW), it can still have a noticeable influence on the energy distribution of Earth-atmosphere system, particularly due to the strong light-absorptive properties commonly found in many terrestrial minerals. The current effort is part of an ongoing research study to perform a global assessment of dust direct aerosol radiative effects (DARE) during major field deployments of key dust source regions worldwide. In this work we present results stemming from two previous field deployments: the 2006 NASA African Monsoon Multidisciplinary Activities and the 2008 Asian Monsoon Years, both utilizing NASA Goddard's mobile ground-based facility. The former study focused on transported Saharan dust at Sal (16.73degN, 22.93degW), Cape Verde along the west coast of Africa while the latter focused on Asian dust at Zhangye (39.082degN, 100.276degE), China near the source between the Taklimakan and Gobi deserts. Due to the compelling variability in spatial and temporal scale of dust properties during field experiments, a deterministic I-D radiative transfer model constrained by local measurements (i.e., spectral photometry/interferometry and lidar for physical/microphysical, mineralogy, and single-scattering properties) is employed to evaluate dust's local instantaneous SW/LW DARE both at the surface and at the top of the atmosphere along with heating rate profiles for cloud-free atmospheres. In both dust cases the efficiency in the L W DARE is investigated and its significance is compared relative to that of diurnally SW.

Tsay, Si-Chee↗

A Framework to Survey the Energy Efficiency of Installed Motor Systems

While motors are ubiquitous throughout the globe, there is insufficient data to properly assess their level of energy efficiency across regional boundaries. Furthermore, many of the existing data sets focus on motor efficiency and neglect the connected drive and system. Without a comprehensive survey of the installed motor system base, a baseline energy efficiency of a country or region’s motor systems cannot be developed. The lack of data impedes government agencies, utilities, manufacturers, distributers, and energy managers when identifying where to invest resources to capture potential energy savings, creating programs aimed at reducing electrical energy consumption, or quantifying the impacts of such programs. This paper will outline a data collection framework for use when conducting a survey under a variety of execution models to characterize motor system energy efficiency within a country or region. The framework is intended to standardize the data collected ensuring consistency across independently conducted surveys. Consistency allows for the surveys to be leveraged against each other enabling comparisons to motor system energy efficiencies from other regions. In creating the framework, an analysis of various motor driven systems, including compressed air, pumping, and fan systems, was conducted and relevant parameters characterizing the efficiency of these systems were identified. A database using the framework will enable policymakers and industry to better assess the improvement potential of their installed motor system base particularly with respect to other regions, assisting in efforts to promote improvements to the energy efficiency of motor driven systems.

Rao, Prakash↗

A comparative study of two-way and offline coupled WRF v3.4 and CMAQ v5.0.2 over the contiguous US: performance evaluation and impacts of chemistry–meteorology feedbacks on air quality

The two-way coupled Weather Research and Forecasting and Community Multiscale Air Quality (WRF-CMAQ) model has been developed to more realistically represent the atmosphere by accounting for complex chemistry–meteorology feedbacks. In this study, we present a comparative analysis of two-way (with consideration of both aerosol direct and indirect effects) and offline coupled WRF v3.4 and CMAQ v5.0.2 over the contiguous US. Long-term (5 years from 2008 to 2012) simulations using WRF-CMAQ with both offline and two-way coupling modes are carried out with anthropogenic emissions based on multiple years of the U.S. National Emission Inventory and chemical initial and boundary conditions derived from an advanced Earth system model (i.e., a modified version of the Community Earth System Model/Community Atmospheric Model). The comprehensive model evaluations show that both two-way WRF-CMAQ and WRF-only simulations perform well for major meteorological variables such as temperature at 2 m, relative humidity at 2 m, wind speed at 10 m, precipitation (except for against the National Climatic Data Center data), and shortwave and longwave radiation. Both two-way and offline CMAQ also show good performance for ozone (O3) and fine particulate matter (PM 2.5 ). Due to the consideration of aerosol direct and indirect effects, two-way WRF-CMAQ shows improved performance over offline coupled WRF and CMAQ in terms of spatiotemporal distributions and statistics, especially for radiation, cloud forcing, O 3 , sulfate, nitrate, ammonium, elemental carbon, tropospheric O 3 residual, and column nitrogen dioxide (NO 2 ). For example, the mean biases have been reduced by more than 10 W m –2 for shortwave radiation and cloud radiative forcing and by more than 2 ppb for max 8 h O 3 . However, relatively large biases still exist for cloud predictions, some PM 2.5 species, and PM 10 that warrant follow-up studies to better understand those issues. The impacts of chemistry–meteorological feedbacks are found to play important roles in affecting regional air quality in the US by reducing domain-average concentrations of carbon monoxide (CO), O 3 , nitrogen oxide (NO x ), volatile organic compounds (VOCs), and PM 2.5 by 3.1 % (up to 27.8 %), 4.2 % (up to 16.2 %), 6.6 % (up to 50.9 %), 5.8 % (up to 46.6 %), and 8.6 % (up to 49.1 %), respectively, mainly due to reduced radiation, temperature, and wind speed. The overall performance of the two-way coupled WRF-CMAQ model achieved in this work is generally good or satisfactory and the improved performance for two-way coupled WRF-CMAQ should be considered along with other factors in developing future model applications to inform policy making.

58 GEOSCIENCES↗

Investigation of Process Emissions during Thermal Cutting of Clad Metals from the Nuclear Sector - 20183

Typically, reactor pressure vessels as well as steam generators comprising low alloyed steel with a cladding of stainless steel. Recently the permissible values for Cr (VI) in the air of the working areas have been reduced in Germany from 100 μg/m{sup 3} to 1 μg/m{sup 3} air. This results in the danger that even with low-alloy steel with claddings these limit values would be exceeded when using flame cutting technologies. In order to ensure compliance with the permissible limit values, exhaust gas systems with gas cleaning measures are provided. The process emission test shall replace the assumptions required for the design of these systems with measured values. NUKEM Technologies Engineering Services GmbH (NUKEM) has chosen autogenous flame cutting as an example of a thermal cutting system for process emission testing, as there are no proven values in the literature for the Cr (VI) and NiOx emissions produced. The autogenous flame cutting can be used for a variety of cutting tasks within decommissioning projects. In order to simulate the material to be cut, mock ups were generated and cut from information about the material specification for the reactor pressure vessel from existing nuclear power plants including possible claddings. The cutting length needed for analysis in the test will be maximum 100 mm. The airborne emissions from the thermal cutting process will be captured and analyzed as follows: - Dust emission: The generated particles will be collected by a hood equipped with strong suction device and suitable filter elements. The resulting filter is gravimetrically measured before and after the tests. - Particle Size Distribution: The airborne particle size distribution measurement will result in figures for the size and number of particles arising from the thermal cutting process. - Gas Analysis: The gas analysis enables the determination of e.g. CO{sub 2}, CO, O{sub 3}, NO, NO{sub 2}. - Cr (VI) and NiOx Analysis: For the Cr (VI) and NiOx analysis, samples of the filter residue will be taken. As a result Cr (VI) in relation to total Cr as well as the Ni content will be determined by ICP-optically emission spectroscopy and put in relation to the total dust amount. The process emissions test itself as well as the necessary gas analyses and spectroscopic analyses were carried out at the Institute of Materials Science (IW) of Leibniz Universitaet Hannover (LUH). The results of the process emission tests are used to confirm the design of the gas cleaning systems. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-T-546: Modeling and Validation of the a New Proton Therapy System Using a Monte-Carlo Environment Optimized for Protons

8 particle histories were run. Results: Range measurements of the Monte-Carlo simulations matched the measured data within 1mm. Distal fall-off of the simulated fields matched within <1mm. Lateral penumbra and field size measurements of the standard-sized square and half-beam blocked fields matched within 1mm at all three planes compared. A small difference was seen in the in-air profiles at doses <0%. The suspected cause of the difference was the aperture shape. The measured data utilized a divergent aperture. The Monte-Carlo calculation used a non-divergent aperture. Conclusion: The validation measurements indicate that we were able to accurately model the MEVION s250 Proton therapy system using Monte-Carlo Calculations. This may reduce the commissioning time for future users. Purpose: Monte-Carlo modeling is an important tool for understanding the behavior of therapeutic proton beams in a heterogeneous media such as the patient. To gain confidence that a Monte-Carlo model is accurate in complex geometries and media, it must first be compared with measurement in simple situations. This study documents the validation of our Monte-Carlo Model. Methods: A model of the MEVION s250 Proton therapy system was created in the TOPAS Monte-Carlo environment using machine geometry and field shaping system information provided by the vendor. For each of 24 options, validation of the TOPAS model was performed by comparing the dose scored by TOPAS to the dose measurements obtained during the commissioning of the treatment planning system. The measurements compared consisted of: pristine peak depth-dose profiles, in-air profiles for a standard-sized square field (20cm×20cm or 10cm×10cm depending on the maximum field size for each option) at isocenter and at 20cm upstream and downstream of isocenter, and in-air profiles with a half-beam blocked aperture at isocenter and at 20cm upstream and downstream of isocenter. For all Monte-Carlo simulations,.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of wettability alteration on 3D nonwetting phase trapping and transport

We investigate capillary trapping and fluid migration via x-ray computed microtomography (x-ray CMT) of nonwetting phase (air) and wetting phase (brine) in Bentheimer sandstone cores which have been treated to exhibit different degrees of uniform wettability. x-Ray CMT scans were acquired at multiple steps during drainage and imbibition processes, as well as at the endpoints; allowing for assessment of the impact of wettability on nonwetting phase saturation and cluster size distribution, connectivity, topology and efficiency of trapping. Compared with untreated (water-wet) Bentheimer sandstone, cores treated with tetramethoxylsilane (TMS) were rendered weakly water-wet, and cores treated with octadecyltrichlorosilane (OTS) demonstrate intermediate-wet characteristics. As apparent contact angle increases, drainage flow patterns deviate from those derived for water-wet systems, total residual trapping and trapping efficiency decrease, and buoyancy plays a larger role during nonwetting phase mobilization; this has significant implications for CO 2 migration and trapping during CO 2 sequestration operations.

54 ENVIRONMENTAL SCIENCES↗

Stochastic simulation of pulverized coal (PC) processes

An increasing population and electricity demand in the U.S. require capacity expansion of power systems. The National Energy Technology Laboratory (NETL), U.S. Department of Energy (DOE), has invested considerable efforts on research and development to improve the design and simulation of these power plants. Incorporation of novel process synthesis techniques and realistic simulation methodologies yield optimal flowsheet configurations and accurate estimation of their performance parameters. To provide a better estimation of such performance indicators, simulation models should predict the process behavior based on not only deterministic values of well-known input parameters but also uncertain variables associated with simulation assumptions. In this work, the stochastic simulation of a load-following pulverized coal (PC) power plant takes into account the variation of three input variables, namely, atmospheric air temperature, atmospheric air humidity, and generation load. These uncertain variables are characterized with probability density functions (pdfs) obtained from available atmospheric and electrical energy generation data. The stochastic simulation is carried out by obtaining a sample of values from the pdfs that generates a set of scenarios under which the model is run. An efficient sampling technique [Hammersley sequence sampling (HSS)] guarantees a set of scenarios uniformly distributed throughout the uncertain variable range. Then, each model run generates results on performance parameters as cycle efficiency, carbon emissions, sulfur emissions, and water consumption that are statistically analyzed after all runs are completed. Among these parameters, water consumption is of importance because an increasing demand has been observed mostly in arid regions of the country and, therefore, constrains the operability of the processes. This water consumption is significantly affected by atmospheric uncertainties. The original deterministic process model simulation was designed in Aspen Plus, and a CAPE-OPEN compliant stochastic simulation capability is employed to run the uncertainty analysis. Initially, the influences of atmospheric conditions and load change on the performance parameters are analyzed separately to understand their individual influences on the process, and then their simultaneous variation is analyzed to generate more realistic estimations of the process performance.

97 MATHEMATICS AND COMPUTING↗

Ford Thermoelectric HVAC Project (Final Report)

Current light-duty vehicles provide passenger thermal comfort primarily through the use of a centralized HVAC (Heating, Ventilation, and Air Conditioning) unit that distributes conditioned air to vent locations throughout the vehicle. A substantial portion of the air energy content is spent conditioning various elements of the vehicle's interior structures. This is not an overwhelming issue in today’s vehicles, but as pressure builds to improve powertrain efficiency, the energy available to provide occupant comfort will decrease. Thermoelectric devices were identified by the US Department of Energy as one method to potentially reduce HVAC-related energy consumption in vehicles. The objective of the Ford Thermoelectric HVAC Project was to identify a technical and business approach to accelerate research and development of light-duty automotive thermoelectric HVAC technology. A zonal HVAC system was developed to provide thermal comfort to each occupant, with the objective of reducing the overall power consumed by the HVAC system compared with a baseline system. The system was designed to provide a basis for a down-sized central HVAC unit, while providing equivalent comfort and equivalent heating/cooling time-to-comfort at startup, and reduce the energy consumed to provide these functions. Project success was evaluated using occupant comfort and energy consumption metrics, based on a novel thermal comfort-modeling approach, and empirical testing. The ability to produce and market the thermoelectric devices developed in this program was assessed by a business analysis that outlined key steps required for thermoelectric HVAC devices to come to market. Key hardware and controls attribute requirements were identified to determine how they contribute to the commercialization potential of the technology. Final testing and analysis showed that use of thermal comfort and zonal design criteria reduced the energy consumption of the climate control system in both heating and cooling tests, and were significantly better in low vehicle occupancy cases where zonal strategies could be employed. Thermoelectric devices were utilized in the vehicle design to support achieving the technical performance goals of the project. It was found that these devices need additional development in order to address commercial issues, due to their cost and performance limitations.

99 GENERAL AND MISCELLANEOUS↗

Pathway to Zero Energy Windows: Advancing Technologies and Market Adoption

As of 2021, buildings account for 39.1% of total U.S. primary energy use and 75% of total U.S. electricity use. Much of this energy is used to maintain a comfortable indoor environment. The building envelope consists of transparent and opaque elements that serve as a controllable barrier to help maintain the indoor environment regardless of external conditions. The envelope also allows the exchange of light and air, as well as other transfers with the external environment when it is beneficial for the building occupants. By leveraging desirable external environmental conditions (e.g., fresh air and natural light) and mitigating the influence of undesirable conditions (e.g., moisture, hot or cold temperatures, wind), the building envelope can reduce the need for space conditioning and electric light, and thus reduce energy use associated with lighting and heating, cooling, and ventilation equipment. In turn, high-performance building envelopes can reduce the substantial CO 2 emissions associated with energy use to satisfy heating, cooling, and lighting needs in buildings. The U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) Emerging Technologies program supports R&D for technologies, systems, and software tools that can contribute to reductions in building energy use. Emerging Technologies funding is distributed competitively through solicitations (e.g., Funding Opportunity Announcements and National Lab Calls, which in general are open to applications from industry, academia, national laboratories, and other entities) and other mechanisms. This document focuses on R&D for windows and window system technologies and will provide guidance for BTO's investments in developing the next generation of high-performance, affordable, cost competitive windows, as well as integrated daylighting and shading technologies in partnership with industry and researchers. This document also addresses areas where DOE invests in software and design tools that translate sophisticated and complex physics into easy-to-use energy performance and optimization methods used by industry and other stakeholders for implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Illustrated structural application of universal first-order reliability method

The general application of the proposed first-order reliability method was achieved through the universal normalization of engineering probability distribution data. The method superimposes prevailing deterministic techniques and practices on the first-order reliability method to surmount deficiencies of the deterministic method and provide benefits of reliability techniques and predictions. A reliability design factor is derived from the reliability criterion to satisfy a specified reliability and is analogous to the deterministic safety factor. Its application is numerically illustrated on several practical structural design and verification cases with interesting results and insights. Two concepts of reliability selection criteria are suggested. Though the method was developed to support affordable structures for access to space, the method should also be applicable for most high-performance air and surface transportation systems.

Verderaime, V.↗

STXM-C-XANES, IR Microspectroscopy, and Raman Microspectroscopy Analysis of Organic Matter in the Chwichiya 002 C3.00-Ungrouped Chondrite

Chwichiya 002 is a C3.00-ungrouped carbonaceous chondrite discovered in Western Sahara in 2018. The presence of hydrated phases in Chwichiya 002 was not confirmed by XRD analysis, and only a faint water and Si-O band attributed to phyllosilicate were observed by infrared transmission spectroscopy, indicating a very low degree of aqueous alteration (Meteoritical Bulletin, 2020). The structural order of polycyclic aromatic hydrocarbons evaluated by Raman spectroscopy indicates that the effect of thermal metamorphism is less severe than in the Semarkona meteorite, an LL3.00 ordinary chondrite (Meteoritical Bulletin, 2020). Chiwichiya 002 is a very primitive carbonaceous chondrite and an important information source for the early stage of the evolution of organic matter in the solar system. In this study, we investigated the molecular structure and distribution of organic matter in Chiwichiya 002 by Carbon X-ray Absorption Near Edge Structure (C-XANES) analysis using a Scanning Transmission X-ray Microscope (STXM). The STXM-C-XANES analysis has a spatial resolution of 20~100 nm and can observe the spatial distribution of organic materials in microstructures. In addition, to investigate the degree of thermal metamorphism of the organic matter, micro-IR, and micro-Raman spectroscopic analyses were performed. In addition, the Murchison CM2 chondrite was also analyzed for comparison. To evaluate contamination during analytical procedures, antigorite, which was heated in air at 500°C for 5 hours to eliminate organic matter was also analyzed in the same manner. The samples were milled into 100 nm-thick, thin sections using a Focused Ion Beam (FIB), and C-XANES spectra were obtained using the STXM at the High Energy Accelerator Research Organization, Photon Factory (PF), BL-19B. The obtained C-XANES spectra were smoothed and then fitted with Gaussian functions using the method of Le Guillou et al. (2018). The C-XANES showed that the ratio of oxygenated functional group (ketone, phenolic) carbons in Chwichiya 002 was lower than in Murchison, whereas the ratio of aliphatic carbons was almost the same. This may reflect the low degree of aqueous alteration of Chwichiya 002. In addition, contamination peaks were detected at 287.3-287.7 eV and 288.3-288.7 eV in the C-XANES spectra of some of the antigorite samples. The source of these peaks is under investigation. Raman spectroscopic analysis showed that the intensity ratio of the D band to the G band of Chwichiya 002 was slightly higher than that of Murchison. IR absorption spectra showed aromatic absorption at 1630 cm -1 , but there was little absorption due to aliphatic C-H around 2900 cm -1 . These results suggest that the organic matter in Chwichiya 002 may be more heated than in Murchison.

Chwichiya 002↗

Air-To-Water Heat Pumps with Radiant Delivery in Low Load Homes: Tucson, Arizona and Chico, California (Fact Sheet)

Space conditioning represents nearly 50% of average residential household energy consumption, highlighting the need to identify alternative cost-effective, energy-efficient cooling and heating strategies. As homes are better built, there is an increasing need for strategies that are particularly well suited for high performance, low load homes. ARBI researchers worked with two test homes in hot-dry climates to evaluate the in-situ performance of air-to-water heat pump (AWHP) systems, an energy efficient space conditioning solution designed to cost-effectively provide comfort in homes with efficient, safe, and durable operation. Two monitoring projects of test houses in hot-dry climates were initiated in 2010 to test this system. Both systems were fully instrumented and have been monitored over one year to capture complete performance data over the cooling and heating seasons. Results are used to quantify energy savings, cost-effectiveness, and system performance using different operating modes and strategies. A calibrated TRNSYS model was developed and used to evaluate performance in various climate regions. This strategy is most effective in tight, insulated homes with high levels of thermal mass (i.e. exposed slab floors).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar plus: Optimization of distributed solar PV through battery storage and dispatchable load in residential buildings

As utility electricity rates evolve, pairing solar photovoltaic (PV) systems with battery storage has potential to ensure the value proposition of residential solar by mitigating economic uncertainty. In addition to batteries, load control technologies can reshape customer load profiles to optimize PV system use. The combination of PV, energy storage, and load control provides an integrated approach to PV deployment, which we call 'solar plus'. The U.S. National Renewable Energy Laboratory's Renewable Energy Optimization (REopt) model is utilized to evaluate cost-optimal technology selection, sizing, and dispatch in residential buildings under a variety of rate structures and locations. The REopt model is extended to include a controllable or 'smart' domestic hot water heater model and smart air conditioner model. We find that the solar plus approach improves end user economics across a variety of rate structures - especially those that are challenging for PV - including lower grid export rates, non-coincident time-of-use structures, and demand charges.

14 SOLAR ENERGY↗

Thermal and electric multidomain dynamic model for integration of power grid distribution with behind-the-meter devices

As renewable energy sources like solar and wind power become more integrated into the grid, coordinated control of behind-the-meter devices is crucial for enhancing grid flexibility and reliability and for meeting cost targets, with standardized models being developed to support this transition. The increasing flexibility and uncertainty of integrated renewable energy grids, along with interactions between various subsystems, make traditional steady-state modeling insufficient to capture transient and dynamic behaviors. Current models (e.g., composite load and battery equivalent models) focus on thermodynamic or electrical characteristics but overlook critical electromechanical interactions. This limits the ability to share performance information for grid services and hampers fast dynamic simulations. In addition, motor stalling is usually triggered by a fault event and attributed to the characteristics of the mechanical torque of the motor, resulting in absorption of a large amount of reactive power during the stalling period. Further, this significant withdrawal of reactive power will deteriorate the dynamic voltage stability of power grids and cause delayed voltage recovery. Therefore, an in-depth modeling of the thermodynamics or mechanical torque is essential to study the impacts of the realistic torque characteristics of those behind-the-meter devices on power system voltage stability. This study developed a dynamic multidomain model for building HVAC systems, such as air-source heat pumps, to simulate their thermal and electrical responses to grid transients. The model can accurately predict power metrics with a mean absolute percentage error of 10%, by validating against with power system computer-aided design performance data. Case studies demonstrate the model capability of capturing the transient response to sudden voltage changes, rapid load fluctuations, and system shutdowns respectively. During a sudden voltage drop (30% for 0.1s), a fully loaded heat pump’s motor speed dropped, continued declining, and shut down after 3.6s, with severe power oscillations and a torque spike. A partially loaded unit experienced temporary oscillations but stabilized. Under higher building loads, compressor speed increased from 64% to 100%, with power and torque rising before stabilizing. In safety-triggered shutdowns, power decreased after minor fluctuations, and torque briefly spiked before dropping to zero.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Novel dense membrane for hydrogen separation for energy applications

The main objectives of this project are: (1) Characterization of the thermo mechanical properties of the novel dense HTM bulk sample; (2) Development of a correlation among the intrinsic factors (such as grain size and phase distribution), and the extrinsic factors (such as temperature and atmosphere) and the thermo-mechanical properties (such as strengths and stress) to predict the performance of a HTM system (HTM membrane and porous substrate) ; and (3) Evaluation of the stability of the novel HTM membrane and its property correlations after thermal cycling. Based on all results and analysis of the thermo mechanical properties for the HTM cermet bulk samples, several important conclusions were made. The mean σfs at room temperature is approximately 356 MPa for the HTM cermet. The mean σfs value decreases to 284 MPa as the temperature increases to 850?C. The Difference difference in atmosphere, such as air or N2, had an insignificant effect on the flexural strength values at 850?C for the HTM cermet. The HTM cermet samples at room temperature and at 500?C fractured without any significant plastic deformation. Whereas, at 850?C, the HTM cermet samples fractured, preceded by an extensive plastic deformation. It seems that the HTM cermet behaves more like an elastic material such as a nonmetal ceramic at the room temperature, and more like a ductile material at increased temperature (850?C). The exothermic peak during the TG/DTA tests centered at 600?C is most likely associated with both the enthalpy change of transformation from the amorphous phase into crystalline zirconia and the oxidation of Pd phase in HTM cermet in air. The endothermic peak centered at 800?C is associated with the dissociation of PdO to Pd for the HTM cermet sample in both inert N2 environment and air. There is a corresponding weight gain as oxidation occurs for palladium (Pd) phase to form palladium oxide (PdO) and there is a weight loss as the unstable PdO is dissociated back to Pd and oxygen. The normal stress and shear stresses from the Mohr?s circle indicate that the residual stress in the HTM cermet sample is mainly as compressive residual stress in the magnitude of -135 to -155 MP, and with very little shear stress (in the magnitude of 10 MPa). The magnitude of change in the normal stress and the shear stress is insignificant in the HTM after 120 thermal cycles. However, the principle normal stress changes from compressive to tensile residual stress and there is a significant increase in the shear stress after 500 thermal cycles. The calculated value based on the equation and the Mohr?s circle is found to be consistent with the experimental value for the as-received HTM cermet samples. At some rotation (φ) angle, the residual stress was found to be as tensile stress. Most ceramic material is weak in tension, and develops microscopic cracks. With treatment of 120 thermal cycles between 50?850?C, the HTM- sample exhibited thermally-induced cracks on the surface. Visually observable cracks appeared on the surface of HTM cermet with continuous thermal cycling, after 500 thermal cycles. The XRD powder diffraction analysis indicated an increased amount of crystalline PdO crystalline in HTM cermet after 120 and 500 thermal cycles as compare to the as-received samples. The Pd crystalline peaks were found to significantly decrease in peak intensity with thermal cycling. Higher peak intensity for PdO phase was observed with increased number of thermal cycles. A Monoclinic monoclinic zirconia phase was first identified in the as-received HTM as-received sample. However, with thermal cycling treatment of both 120 and 500 thermal cycles, the M-ZrO2 phase is transformed to the tetragonal YSZ, which is consistent with the thermal analysis results by TG/DTA. Correlations of the microstructural and thermo-mechanical properties of both selected reference material and ANL-3e HTM cermet bulk sample are affected mainly by porosity and microstructural features, such as grain size and pore size/distribution. The Young?s Modulus (E-value), especially, is positively proportional to the flexural strength for materials with similar crystallographic structure. For different crystallographic materials, physical properties such as E and density are independent of mechanical properties, such as flexural strength.. Microstructural properties, particularly, grain size and crystallographic structure, and thermodynamic properties are the main factors affecting the mechanical properties at both room and high temperatures. The oxidation and the plasticity of Pd phase mainly affect the mechanical properties of HTM cermet at high temperature or with thermal cycling treatment. Changes in the residual stress and microstructure affect the mechanical properties of HTM when subjected to high temperature or thermal cycling treatment.

08 HYDROGEN↗

Pressure distributions on a 0.04-scale model of the Space Shuttle Orbiter's forward fuselage in the Langley unitary plan wind tunnel

Pressure distribution tests on a 0.04-scale model of the forward fuselage of the Space Shuttle Orbiter are presented without analysis. The tests were completed in the Langley Unitary Plan Wind Tunnel (UPWT). The UPWT has two different test sections operating in the continuous mode. Each test section has its own Mach number range. The model was tested at angles of attack from -2.5 deg to 30 deg and angles of sideslip from -5 deg to 5 deg in both test sections. The test Reynolds number was 6.6 x 10 to the 6th power per meter. The tests were conducted in support of the development of the Shuttle Entry Air Data System (SEADS). In addition to modeling the 20 SEADS pressure orifices, the wind-tunnel model was also instrumented with orifices to match Development Flight Instrumentation (DFI) port locations currently existing on the Space Shuttle Orbiter Columbia (OV-102). This DFI simulation has provided a means for comparisons between reentry flight pressure data and wind-tunnel data.