Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

A lab-based ambient pressure x-ray photoelectron spectrometer with exchangeable analysis chambers

Ambient pressure X-ray photoelectron spectroscopy (APXPS) is a powerful spectroscopy tool that is inherently surface sensitive, elemental, and chemical specific, with the ability to probe sample surfaces under Torr level pressures. Herein, we describe the design of a new lab-based APXPS system with the ability to swap small volume analysis chambers. Ag 3d(5/2) analyses of a silver foil were carried out at room temperature to determine the optimal sample-to-aperture distance, x-ray photoelectron spectroscopy analysis spot size, relative peak intensities, and peak full width at half maximum of three different electrostatic lens modes: acceleration, transmission, and angular. Ag 3d(5/2) peak areas, differential pumping pressures, and pump performance were assessed under varying N{sub 2}(g) analysis chamber pressures up to 20 Torr. The commissioning of this instrument allows for the investigation of molecular level interfacial processes under ambient vapor conditions in energy and environmental research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ATCA/muTCA for Physics

ATCA/{mu}TCA platforms are attractive because of the modern serial link architecture, high availability features and many packaging options. Less-demanding availability applications can be met economically by scaling back speed and redundancy. The ATCA specification was originally targeted for the Telecom industry but has gained recently a much wider user audience. The purpose of this paper is to report on present hardware and software R and D efforts where ATCA and {mu}TCA are planned, already being used or in development using selected examples for accelerator and detectors in the Physics community. It will present also the status of a proposal for physics extensions to ATCA/{mu}TCA specifications to promote inter-operability of laboratory and industry designs for physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NACA Three Component Accelerometer

A new instrument known as the NACA three component accelerometer is described in this note. This instrument was designed by the technical staff of the NACA for recording accelerations along three mutually perpendicular axes, and is of the same type as the NACA single component accelerometer with the addition of two springs and a few minor improvements such as a pump for filling the dash-pots and a convenient method for aligning the springs. This note includes a few records as well as photographs of the instrument itself.

Reid, H J E↗

A simple gating technique for high-average-current photo-injectors

This paper describes a simple method that substantially improves the production of gated electron bunch trains by totally suppressing undesired background photoemission between the trains. A device has been designed and tested with a drive laser for proof-of-principle demonstration. The predicted functionality and performance are verified on an Energy-Recovery-Linac (ERL) electron accelerator. The method can find applications whenever the laser pulse repetition rate and length need to be tailored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Autonomous closed-loop mechanistic investigation of molecular electrochemistry via automation

Abstract Electrochemical research often requires stringent combinations of experimental parameters that are demanding to manually locate. Recent advances in automated instrumentation and machine-learning algorithms unlock the possibility for accelerated studies of electrochemical fundamentals via high-throughput, online decision-making. Here we report an autonomous electrochemical platform that implements an adaptive, closed-loop workflow for mechanistic investigation of molecular electrochemistry. As a proof-of-concept, this platform autonomously identifies and investigates an EC mechanism, an interfacial electron transfer ( E step) followed by a solution reaction ( C step), for cobalt tetraphenylporphyrin exposed to a library of organohalide electrophiles. The generally applicable workflow accurately discerns the EC mechanism’s presence amid negative controls and outliers, adaptively designs desired experimental conditions, and quantitatively extracts kinetic information of the C step spanning over 7 orders of magnitude, from which mechanistic insights into oxidative addition pathways are gained. This work opens opportunities for autonomous mechanistic discoveries in self-driving electrochemistry laboratories without manual intervention.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The RHIC p-Carbon CNI Polarimeter Upgrade For The Beam Polarization And Intensity Measurements

Proton polarization measurements in the AGS and RHIC (Relativistic Heavy Ion Collider at the beam energies 24-250 GeV) are based on proton-carbon and proton-proton elastic scattering in the Coulomb Nuclear Interference (CNI) region. Polarimeter operation in the scanning mode also gives polarization profile and beam intensity profile (beam emittance) measurements. Bunch by bunch emittance measurement is a very powerful tool for machine setup. Presently, the polarization and beam intensity profile measurements (in both vertical and horizontal planes) are restricted by the long target switching time and possible target destruction during this complicated motion. The RHIC polarimeters were operated near the limit of the counting rate for present silicon strip detectors. The ongoing polarimeter upgrade for the 2009 run will address all these problems. The upgrade should allow significant reduction of the polarization measurement errors by making feasible the complete polarization measurements, which includes polarization profiles in both the horizontal and vertical planes.

43 PARTICLE ACCELERATORS↗

Measurements of the Influence of Thermoplastic Mask in High Energy Photon Beams: Gel Dosimeter or Ionizing Chamber?

The influence of the immobilization mask material on the absorbed dose distribution in patients exposed to radiotherapy treatment with photon beams has been investigated for photons from a 60Co source and a 6 MV Linac. Absorbed dose values have been inferred at different depths and in the build-up region. Dose measurements were obtained using Fricke Xylenol Gel dosimeter and the cylindrical PTW Freiburg TM 31016-0.016 cc ionizing micro chamber; their discrepancies are discussed. The affinities of FXG and PTW ICMicro for measurements with high energy photons and the difference in the effective atomic numbers due to their compositions are most likely the most important factors that contribute to the measured dose in the build-up region. The measured values show that the use of the mask material contributes to increase the absorbed doses near the surface of the tissue. The result also shows that the build-up effect for {sup 60}Co is significantly smaller than that for 6 MV photons; however, the variations noted in the final doses of the radiotherapic treatments with photons of high energy do not represent alterations in the total doses received by the patients submitted to the radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of Patient Doses from Verification Techniques in Image-Guided Radiotherapy (IGRT)

The purpose of this work was an evaluation of organ doses and effective doses from kilovoltage (kV) cone-beam CT (CBCT) scans and from pairs of orthogonal kV image projections for two different treatment sites (a head and a pelvis). Measurements of organ doses were performed in an anthropomorphic rando phantom by means of thermoluminescent dosimeters (TLDs). Irradiations were performed using on-board imager (OBI) and X-ray volume imaging (XVI) systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Experimental Background Studies in the Two Photon Exchange (TPE) Experiment at Jefferson Lab

This work is based on the improvement of an existing simulation for the two photon exchange (TPE) experiment at Jefferson Lab developed within the GEANT4 framework. This experiment will determine the ratio of the positron-proton elastic scattering cross section and the electron-proton elastic scattering cross section with high precision. To accomplish this measurement requires the use of a variety of devices and complex arrangements, creating background particles that manage to reach the detector system (CLAS). A number of test runs have identified the sources of background in the detector guided by previous simulations. Even so, the remaining background can be reduced considerably by the microscopic identification and locating of the background sources performed by our new simulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hadron Spectroscopy in Double Pomeron Exchange Processes with the STAR Detector at RHIC

A new hadron spectroscopy program to study particle production at the central region through diffractive processes in polarized p+p collisions at {radical}(s) = 200-500 GeV has been initiated with the STAR detector at RHIC. Staged implementation of multiple Roman Pot stations for tagging forward protons in diffractive processes allows studying for the first time the dynamics of the particle production in the diffractive processes systematically at the RHIC energy regime. The STAR detector system with complete azimuthal coverage at the central region equipped with excellent particle reconstruction capabilities enables studies of the constituent gluonic degree of freedom in double Pomeron exchange processes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of the Polarization Observables I{sup s} and I{sup c} for {gamma}{sup {yields}p{yields}}p{pi}{sup +{pi}-} using the CLAS Spectrometer

Model predictions regarding the excited baryon spectrum provided by Constituent Quark Models show good agreement with experimental measurements in the low-energy region less than {approx_equal}1.8 GeV. The mass region above {approx_equal}1.8 GeV, however, contains many resonances which are predicted to exist by these models but have not been experimentally verified. The analysis of a double meson final state using linearly polarized photoproduction data allows access to two polarization observables, I{sup s} and I{sup c}(also known as the beam asymmetry {Sigma} for a single meson final state). It has been shown that measurements of these polarizaton observables can provide insight into this missing resonance problem. This analysis was carried out on data taken from the CLAS-g8b data run period conducted at Jefferson Lab in Newport News, Virginia. The analysis of this data and preliminary measurements of these obsevables will be dicussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of two-photon exchange effect with CLAS

The structure of the proton is one the most important and most studied topics in nuclear physics. However, discrepant measurements of the proton's electromagnetic form factor ratio, G{sub E}/G{sub M}, seriously jeopardize a definitive understanding of the proton's structure. Measurements of G{sub E}G{sub M} using the Rosenbluth separation technique disagree with those using polarization transfer methods by about a factor of three at Q{sup 2{approx}}5.6 GeV{sup 2}. It has been hypothesized that this discrepancy is due to two-photon exchange (TPE) effects that are not part of the usual radiative corrections. Theoretical corrections for the TPE effect are difficult due to the fact that a large number of excited nucleon states can contribute to the process. However, the TPE effect can be directly determined by measuring the ratio of the positron-proton to electron-proton elastic scattering cross sections, R = {sigma}(e{sup +})/{sigma}(e{sup -}), as the TPE effect changes sign with respect to the charge of the incident particle. A brief test run of a modified beamline and the CLAS detector at Jefferson Lab has resulted in the most precise measurements of the R to date. We will present results from the test run covering Q{sup 2}<0.8 GeV{sup 2} and 0.78{<=}{epsilon}{<=}0.97. In addition, the test run demonstrated the feasibility of producing a mixed electron/positron beam of good quality so that the measurements can be extended up to Q{sup 2{approx}}3.0 GeV{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The In-medium Mass and Widths of Light Vector Mesons

Partial restoration of chiral symmetry in ordinary nuclear matter suggests the modification of properties of vector mesons, such as a shift in mass and/or a change of width. Photoproduction of vector mesons off nuclei were performed at Jefferson Lab using the CEBAF Large Acceptance Spectrometer (CLAS). The properties of the {rho}, {omega} and {phi} mesons were investigated via their rare leptonic decay to e+e-. This decay channel has an advantage over hadronic modes as it eliminates final state interactions in the nuclear matter. After subtracting the combinatorial background, the meson mass distributions were extracted for each of the nuclear targets. No significant mass shift is observed, however substantial increase in the widths of the mesons is reported.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New Generation of Nuclear Physics at RIKEN

I report present status and perspectives of RIBF ''RI Beam Factory (RIBF)'' at RIKEN. RIBF is a top world-class in-flight RIB facility. Emphasis is given to on-going and future programs at the new facility through introducing experimental devices and recent highlights.

43 PARTICLE ACCELERATORS↗

Development of FPGA-based multi-sensor excitation low voltage (MSELV) chassis at Jefferson Lab

The design and development of the sensor excitation and read back chassis was driven by the requirements for the monitoring and control of two conduction-cooled superconducting magnets in Hall B for the 12 GeV accelerator upgrade. The torus and solenoid superconducting magnets require extensive instrumentation. Sensor selection was accomplished by applying Jefferson Lab’s (JLab) risk mitigation process, which employed a failure modes and effects analysis approach. The goal was to accommodate all sensor types for monitoring and control and to develop a generic multisensor excitation low voltage chassis that would be used across both magnet systems with a reduced set of functions. As a result, the chassis has been deployed in experimental Hall B at JLab and has been performing successfully since July 2016.

47 OTHER INSTRUMENTATION↗

Bond Wire Damage Detection and SOH Estimation of a Dual Pack IGBT Power Module using Active Power Cycling and Reflectometry

High thermal and electrical stress, over a period of time tends to cause deterioration of the health of power electronic switches. A huge fraction of research efforts involves the study of power electronic device reliability and development of novel techniques with higher accuracy in health estimation of such devices. Until today, no other existing techniques can determine the number of lifted bond wires and their locations in a live IGBT module. Through this paper, a new method for online condition monitoring of IGBTs and IGBT modules using SSTDR has been proposed. Unlike traditional methods, this research work concentrates at the gate terminals of the device instead of looking at the collector side. In addition, the RL-equivalent circuit to represent a bond wire has been developed for the DUT and simulated in CST Studio Suite to measure the reflection amplitudes. Both the experimental and simulation results have been compared. These results prove that a single measurement is sufficient to predict the failure of the device instead of looking at the traditional precursor parameter. With only two sets of measurements, it is possible to locate the aged device inside a module and detect the number of bond wire lift offs associated to that device.

30 DIRECT ENERGY CONVERSION↗

Selecting 1D projections for 2D tomography reconstruction

Previous works on reconstructing the 4D phase space using tomography require optimal selection of projection views to achieve accurate reconstruction. In 2D reconstruction, the process is straightforward, as an object can be evenly sampled by dividing the angles evenly. However, extending this concept from 2D to 4D is not intuitive. This work demonstrates that quaternions can be used to more effectively describe views in 4D and introduces the Fibonacci Flower algorithm and repulsive force algorithm to evenly space views in 4D space in order to achieve higher reconstruction accuracy.

Accelerator Physics↗