Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ac”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,513 records · Page 84

Investigation of HTS Twisted Stacked-Tape Cable (TSTC) Conductor for High-Field, High-Current Fusion Magnets

The critical currents of a twisted single-tape were measured at 4.2 K in fields up to 17 T. It was confirmed that the critical current of a twisted-tape was similar to that of a flat tape in c-axis fields. Based on the single-tape critical-currents, a 40-tape (4-mm width) twisted stacked-tape cable (TSTC) conductor was experimentally evaluated at fields up to 17 T at 4.2 K. It was found that the Lorentz load degradation of the TSTC conductor was negligible at the end of a cyclic test. The TSTC cabling method has been considered to be suitable for developing a high-field high-current REBCO conductor for magnet applications as well as power transmission cables. A method to fabricate the inner legs of a D-shape toroidal field coil using a TSTC conductor has been discussed. This method allows the conductor to properly resist the transverse Lorentz load and mitigate ac loss issues by adopting a parallel-HTS-tape flat cable configuration where necessary.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-Frequency, Multiclass Nonintrusive Load Monitoring for Grid-Interactive Residential Buildings

Smart buildings with net-load metering and control capabilities can provide valuable flexibility to grid operators. This article develops a novel approach for high-frequency, multiclass nonintrusive load monitoring (NILM) that enables effective net-load monitoring capabilities with minimal additional equipment and cost. Relative to existing NILM work, the proposed solution operates at a faster timescale, providing accurate multiclass state predictions for each 60-Hz ac cycle without relying on event-detection techniques. The approach is validated using a test bed with residential appliances and shown to have high accuracy, good generalization properties, and sufficient response time to support building grid-interactive control at fast timescales relevant to the provision of grid frequency support services.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Remotely powered line monitor

Improved devices, apparatuses, systems, and methods involving the use of field probes with voltage-controlled variable impedance elements and surface-launched acoustic wave devices, including surface acoustic wave (SAW) devices and SAW sensor-tag wireless interface devices to measure voltage and current in current carrying conductors (CCCs) via measurement of the electric fields and magnetic fields around said CCCs are disclosed. The devices, apparatuses, systems, and methods taught in the present invention include a remotely powered line-mounted measurement unit that requires no connection to electrical ground for operation, and that has no internal energy source, no energy harvesting or power conditioning circuitry, no discrete energy storage components, and no radio. The devices, apparatuses, systems, and methods taught in the present invention also provide for determining the phase (leading or lagging) of the current relative to the voltage in AC power systems, and also provide for measurement of temperature of the conductor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systems, methods and patches for monitoring a structural health of a connector in overhead transmission lines

Systems, methods and piezoelectric patches are provided for monitoring the structural health of connectors in overhead transmission lines. A plurality of piezoelectric patches is mounted to different locations on the connector. At least one of the patches is actuated using an AC voltage and certain electrical properties either from the same patch or of a different patch are evaluated over time to determine the structural health of the connectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nonlinear power flow control for networked AC/DC microgrids

A method for designing feedforward and feedback controllers for integration of stochastic sources and loads into a nonlinear networked AC/DC microgrid system is provided. A reduced order model for general networked AC/DC microgrid systems is suitable for HSSPFC control design. A simple feedforward steady state solution is utilized for the feedforward controls block. Feedback control laws are provided for the energy storage systems. A HSSPFC controller design is implemented that incorporates energy storage systems that provides static and dynamic stability conditions for both the DC random stochastic input side and the AC random stochastic load side. Transient performance was investigated for the feedforward/feedback control case. Numerical simulations were performed and provided power and energy storage profile requirements for the networked AC/DC microgrid system overall performance. The HSSPFC design can be implemented in the Matlab/Simulink environment that is compatible with real time simulation/controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scalable Stochastic Transmission Expansion: A Use Case for ExaSGD

The intermittent nature of renewable energy poses new challenges for power grids due to its variable and un- certain power output. These features of renewable generation are becoming more relevant to transmission planning as grids reach higher penetration levels of renewable energy. In this paper we present an approach for transmission planning based on scalable computational approaches which enable the explicit consideration of operational uncertainties in the planning process. Using three-stage stochastic programming and the progressive hedging algorithm, we compute transmission expansion decisions on a modified RTS-GMLC test system. We augment the grid with large amounts of wind generation and consider many operational scenarios subject to wind uncertainty. This is an example of a possible use of the ExaSGD security constrained AC optimal power flow solver.

Exascale Computing Project↗

Preface

Crystallization via nonclassical pathways is important during the formation of minerals in nature and has become a popular method to synthesize advanced materials on both laboratory and industrial scales. Unlike classical crystal growth pathways via monomer-by-monomer addition, crystallization via nonclassical pathways such as particle-by-particle attachment can form bigger crystals more quickly. Many materials prepared via non-classical crystallization have been applied in various fields such as energy, catalysis, environment, biomedicine, optics, electrics, and magnetics. Understanding nonclassical crystallization pathways could provide new insights on design and synthesize novel materials. This ACS Book series aims to provide updated information on fundamental nonclassical crystallization research, including theory and experiments. It’s also designed for experienced researchers to reinforce their knowledge on the scopes of development of new techniques, especially state-of-the-art in situ characterization tools, to understand mechanisms of crystallization via nonclassical pathways. Topics that would be covered in this book series include: (1) nonclassical nucleation; (2) cluster assembly; (3) particlebased crystallization; (4) crystal formation from amorphous intermedium phases; (5) biomineralization via nonclassical pathways; (6) theoretical developments to simulate nonclassical crystallization; (7) observation of the nonclassical crystallization pathways via various characterization techniques; and (8) the application of nonclassical crystallization. Volume I of the Nonclassical Crystallization Book Series will cover a broad range of topics about nucleation, assembly, observation, and applications of nonclassical crystallization.

Zhang, Xin↗

Pulsed start-up system for electrostatic generators

A new rotor start-up system is provided for application to rotating systems such as stationary or vehicular electromechanical battery systems. An embodiment of the system consists of a “locator” that includes a stationary permanent-magnet pole above which is a circular ferromagnetic (e.g., iron) strip embedded in the lower, inner edge of the flywheel rotor. The lower edge of this strip is wave-like so that the magnet can pull the rotor around to a position where the position relative to the minimum capacity between the rotor and stator electrodes is such as to launch the rotor in a chosen direction, i.e., either clock-wise or counter-clockwise. Startup from rest is then accomplished by applying a short high-voltage ac or dc pulse to the EMB capacitor.

42 ENGINEERING↗

Evaluation of Contact Resistance and Fin Effectiveness of Enhanced, Brazed "Dogbone" Fin and Serpentine Tube Heat Exchangers for Air Conditioning and Heat Pump Applications

The energy consumption due to air conditioning is projected to increase by 1.3 and 4.5 times by 2050 compared to 2010 for members and non-members of the Organization of Economic Coordination and Development (OECD), respectively. Greenhouse Gas (GHG) emissions must be carefully managed to minimize their hazardous contribution to climate change. Air conditioners (AC) and heat pumps (HP) contribute with direct GHG emissions through systemic refrigerant leakage, which consequently degrades the system’s performance and therefore increases its indirect GHG emissions as well. To address this issue, the goals of new systems include minimizing leakage risk, using low global warming potential (GWP) refrigerants such as natural refrigerants, and increasing system efficiency. This paper presents part of the efforts in the development of a brazed “dogbone” fin to continuous serpentine tube heat exchanger (HX) for AC/HP applications. The main advantages of such technology are: 1) The potential to reduce 90% or more of the tube return-bends brazed joints compared to conventional tube-fin heat exchangers, thus minimizing leakage vulnerability, enabling the use of natural refrigerants like Propane and Ammonia that carry other concerning risks of flammability and toxicity ; and 2) The brazed fin to the tube joints should yield very low contact resistance. In order to quantify and estimate the impacts of contact resistance and fin effectiveness, a numerical-experimental study is investigated. The novel enhanced brazed “dog-bone” fin is compared to an equivalent pressure expanded fin. The results showed that the expanded fin has consistently greater effective heat transfer but greater contact resistance as well. Furthermore, the brazed fins have up to 20% lower pressure drop. The trade-off comparison shows that the thermal-hydraulic ratio between the two fins is equivalent for air velocities below 2m/s; for greater velocities, however, the expanded fin is favored since it has less fin efficiency penalty. For HVAC&R applications, the air velocities are typically low which makes the proposed technology competitive and a viable option in the pursuit of refrigerant leakage reduction.

30 DIRECT ENERGY CONVERSION↗

A Robust Yule-Walker Method for Online Monitoring of Power System Electromechanical Modes of Oscillation

Reliable power system operation requires that system operators maintain a satisfactory small-signal stability margin at all times. Mode meters allow system operators to continuously monitor the stability margin by analyzing synchrophasor measurements. Experience with mode meters at the Bonneville Power Administration (BPA) has revealed that mode meters sometimes suffer severe bias following transient disturbances. In this paper, a robust version of the Yule-Walker mode meter algorithm is proposed to mitigate this bias. The robust capability is introduced by modifying the estimator of the autocovariance sequence (ACS) on which the algorithm depends. Tests with field-measured data demonstrate that the robust Yule-Walker (RYW) algorithm significantly outperforms its conventional counterpart and is better able to provide system operators with accurate information about the system's stability margin.

Follum, James D.↗

Ferromagnetic particles as ultra-sensitive non-linear response labels for magnetic particles imaging (MPI) and sensing applications

A significant enhancement of detection capabilities of the room temperature MPQ is seen using optical lithography-defined, ferromagnetic iron-nickel alloy microdisks. Irreversible transitions between strongly non-collinear (vortex) and a collinear single domain states, driven by an ac magnetic field, translate into a nonlinear magnetic response that enables ultrasensitive detection of material at relatively small magnetic fields.

Novosad, Valentine↗

Silicon carbide power inverter/rectifier for electric machines

The present disclosure involves a two stage inverter, a system for electrical power conversation, and a method of converting electrical power using silicon carbide (SiC) metal-oxide-semiconductor field-effect transistors (MOSFETs). One example implementation includes using two or more SiC MOSFETs in series with each MOSFET having a gate terminal for triggering a state switch between an on (conducting) and off (non-conducting) state of the MOSFET. An AC terminal is connected between the series SiC MOSFETS, and the series SiC MOSFETs are connected across a DC bus and in parallel with one or more capacitors.

Shenoy, Suratkal P.↗

Dimming LED circuit augmenting DC/DC controller integrated circuit

Embodiments include systems, methods, and apparatuses for providing a dimming function in a single stage AC input light emitting diode (LED) driver with a controller that contains an on-chip error amplifier and an on-chip fixed reference voltage source coupled to a first input of the error amplifier. The controller controls a duty cycle of a switching transistor to cause a feedback voltage, applied to a first package input terminal, to match the reference voltage. To achieve a dimming function, a voltage across a current sense resistor in series with the LEDs is applied to a first input of a high gain differential amplifier, and a variable dimming control voltage is applied to a second input of the differential amplifier. The output of the differential amplifier is coupled to the first package input terminal. The differential amplifier input signals will be matched at the target LED current level.

Song, Zhengrong↗

Methods for Evaluating DC Arc Incident Energy in PV Systems: Preprint

Renewable energy systems continue to be one of the fastest growing segments of the energy industry. This paper focuses on the understanding of how photovoltaic (PV) technology behaves under dc arc conditions. Emphasis is placed on the electrical safety aspect of DC arc flash incident energy evaluation. Because of the fast proliferation of PV systems and the lack of formal equivalent calculation guidelines such as IEEE 1584 for AC systems, it has been necessary to rely on different equations and models presented by various researchers over the last few years. This paper discusses the behavior of PV systems under arc conditions and presents the results of available methods to estimate the dc arc flash incident energy. This paper provides a comparative analysis of a proposed arc-flash incident energy calculation method against different laboratory tests including those performed by NREL. Detailed explanations are provided regarding the effect of PV module I-V and P-V curves under arcing conditions. Examples of the application of the proposed calculation method to the test measurements are included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Integrated High-performance Computing and Digital Real-time Simulation Testbed to Benchmark Closed-loop Load Shedding Algorithms in Power Systems

An integrated testbed using digital real-time simulator (DRTS) and a high-performance computing (HPC) cluster is presented here to compare speed and performance of computational schemes to mitigate time-critical issues in electric power systems. The first approach in this testbed validation is taken by running a set of closed-loop load shedding algorithms to compare and contrast two paradigms of arresting cascading failure propagation. Two algorithms involve solving DC and AC power flow model-based optimization problems to compute load shedding at different buses, while a model-based stochastic search using parallel computing provides a viable alternative. The algorithms are implemented in the DRTS-HPC testbed for the IEEE 14-bus benchmark transmission system. As a proof of the concept, simulation results are presented for implementation of closed-loop load-shedding algorithms for cascading failures in the DRTS-HPC testbed

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Computationally Improved Heuristic Algorithm for Transmission Switching Using Line Flow Thresholds for Load Shed Reduction

We present a computationally improved heuristic algorithm for transmission switching (TS) to recover load shed. Research from the past showed that changing power system topology may control power flows and remove line congestion. Hence, TS may reduce the required load shed. One of the main challenges is to find a potential TS candidate in a suitable time. Here, we propose a novel heuristic method that is capable of finding the potential TS candidate faster than existing algorithms in literature. The proposed method is compatible with both the AC and DC optimal power flows (OPF). Three metrics are used to compare the proposed algorithm with the state-of-the-art from literature to show the speedup and accuracy achieved. The proposed method is implemented on the IEEE 30-bus system, PEGASE 89-bus system, IEEE 118-bus system, and Polish 2383- bus system. The results on the large-scale Polish 2383-bus system shows that the proposed algorithm is scalable to large real-world systems. Parallel computing is implemented to further improve the computational performance of the proposed algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗