SEARCH · Engineering Papers
Results for “ABLATION”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Novel animal model of multiple sclerosis: The glial connexin gap junction as an environmental tuner for neuroinflammation
Abstract Connexins, which comprise gap junctions (GJs) via homotypic/heterotypic oligomerization, act as channels to connect opposing cells, mainly in solid organs such as the skin, liver, heart, and central/peripheral nervous system. Connexins are synthesized in the endoplasmic reticulum, assembled in the Golgi apparatus as hexamers, and inserted into the cell membrane as hemichannels. These hemichannels are closed under normal conditions until they combine to form clusters and connect to neighboring cells via GJs in a head‐to‐head configuration. Opening of hemichannels, which depends on the intra‐ or extracellular environment, allows various bioactive molecules to enter into or be released from the host cells. Recent pathological studies on human demyelinating diseases have revealed alterations of connexin expression patterns in demyelinating lesions. To elucidate the molecular mechanisms of connexins in the pathomechanisms of inflammatory demyelination, we induced experimental autoimmune encephalomyelitis (EAE) in connexin 30 (Cx30)‐deficient mice, oligodendroglia‐specific Cx47‐ablated mice, and astroglia‐specific Cx43‐ablated mice. We found that both astroglial‐Cx30‐deficient mice and Cx43‐ablated mice showed amelioration of the clinical course of EAE, while oligodendroglial‐Cx47‐ablated mice showed aggravation. These findings indicate the distinct role of connexins expressed in different cell types and the substantial contribution of connexin‐mediated pathology to demyelinating disorders. The imbalance in connexin expression, which is caused by the inflammatory environment, results in an increase in hemichannels in glial cells. The release of proinflammatory molecules induced by the increase in hemichannels on activated glial cells is a crucial mechanism of demyelinating disorders.
Computer modeling of electrical and thermal performance during bipolar pulsed radiofrequency for pain relief
Purpose: Pulsed RF (PRF) is a nonablative technique for treating neuropathic pain. Bipolar PRF application is currently aimed at creating a “strip lesion” to connect the electrode tips; however, the electrical and thermal performance during bipolar PRF is currently unknown. The objective of this paper was to study the temperature and electric field distributions during bipolar PRF. Methods: The authors developed computer models to study temperature and electric field distributions during bipolar PRF and to assess the possible ablative thermal effect caused by the accumulated temperature spikes, along with any possible electroporation effects caused by the electrical field. The authors also modeled the bipolar ablative mode, known as bipolar Continuous Radiofrequency (CRF), in order to compare both techniques. Results: There were important differences between CRF and PRF in terms of electrical and thermal performance. In bipolar CRF: (1) the initial temperature of the tissue impacts on temperature progress and hence on the thermal lesion dimension; and (2) at 37 °C, 6-min of bipolar CRF creates a strip thermal lesion between the electrodes when these are separated by a distance of up to 20 mm. In bipolar PRF: (1) an interelectrode distance shorter than 5 mm produces thermal damage (i.e., ablative effect) in the intervening tissue after 6 min of bipolar RF; and (2) the possible electroporation effect (electric fields higher than 150 kV m{sup −1}) would be exclusively circumscribed to a very small zone of tissue around the electrode tip. Conclusions: The results suggest that (1) the clinical parameters considered to be suitable for bipolar CRF should not necessarily be considered valid for bipolar PRF, and vice versa; and (2) the ablative effect of the CRF mode is mainly due to its much greater level of delivered energy than is the case in PRF, and therefore at same applied energy levels, CRF, and PRF are expected to result in same outcomes in terms of thermal damage zone dimension.
Experimental and numerical evaluation of laser shinethrough in polystyrene at 3 ω and 4 ω laser frequencies
In laser-direct-drive inertial confinement fusion (ICF), laser shinethrough is the process associated with laser propagation through the target plastic ablator, polystyrene is often used in ICF experiments, and leads to energy deposition in the target until the critical density is established at the ablator front surface. This process causes material modifications that may change the shock propagation and lead to density and pressure perturbations at the interface between the polystyrene and cryogenic deuterium-tritium (DT) layer. This work reports on experimental observations and numerical investigations of laser shinethrough at the third and the fourth harmonic of ICF class laser systems (1 ω corresponds to a wavelength of ∼1.06 μm ). The experiments evidence that, at 4 ω , the laser is absorbed over a distance of about a few microns and laser shinethrough is completely eliminated in contrast with the behavior at 3 ω . These experimental observations are reproduced by numerical simulations. The laser fluence required to reach the critical density at the ablator front surface is also found to be more than one order of magnitude higher at the third harmonic. Finally, modeling suggests that the back surface of the ablator exhibits ion temperatures greater than the melting temperature of cryogenic DT and electron pressure larger than the bulk and shear moduli of cryogenic DT for the case of using a 3 ω laser.
OECD MCCI Project: Category 4 Integral Test to Validate Severe Accident Codes and Core-Concrete Interaction Test Six (CCI-6) (Rev. 2, Final Report)
Ex-vessel debris coolability is an important light water reactor (LWR) technical challenge. For existing plants, resolution of this challenge will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this challenge will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence and data for various cooling mechanisms through separate effect tests for severe accident model development, and ii) provide long-term 2-D coreconcrete interaction data for code assessment and improvement. In addition to the experimental work, an analysis task was defined to develop and validate coolability models to form the basis for extrapolating the experiment findings to plant conditions. In response to the PRG mandate, a summary test plan for this sixth Core-Concrete Interaction (CCI-6) experiment was prepared, reviewed by the PRG, and subsequently approved for test conduct. The experiment approach was to incorporate an array of water nozzles into the core-concrete interaction test apparatus. The test section was enlarged to incorporate a 70 cm x 70 cm basemat. The initial melt depth was increased to 28 cm, which corresponds to a thermite charge mass of 900 kg. The melt depth is noted to be slightly less than the 30 cm level requested by the PRG. The thermite charge was redesigned to include a reduced amount of concrete decomposition products (i.e., 6 wt %) relative to the previously performed CCI tests. The concrete sidewalls allow for 24 cm of lateral erosion, and the sidewall design was modified to include refractory MgO with a UO 2 pellet and U 3 O 8 powder liner to stop the ablation if the 24 cm ablation depth was reached. The basemat and sidewalls also included an array of 45 concrete nozzles that were arranged on a 14 cm lateral pitch and were located at a uniform depth of 27.5 cm below the initial concrete basemat surface elevation. The nozzles were originally sealed at the top, and were fed with water from a common water supply tank that provided a static water head of nominally 10 kPa measured at the upper surface of the nozzles. The planned operating sequence was to ignite the thermite and then provide 210 kW Direct Electrical Heating (DEH) to simulate decay heat. The concrete would then heat up and begin erosion. At this point, the cavity would be flooded from the top. If the melt did not cool, then the core-concrete interaction would continue until the 27.5 cm axial ablation depth was reached. At this point, the nozzles would open by erosion and thus initiate cooling by bottom water injection. The test would continue to operate until the melt was quenched, or the maximum axial ablation depth of 32.5 cm was reached. The experiment would then be terminated. The CCI-6 experiment was carried out on 18 March 2010. The balance of this report documents the facility, actual test operating procedure, and results from this experiment.
OECD MCCI Project: Category 4 Integral Test to Validate Severe Accident Codes: Core-Concrete Interaction Test Six (CCI-6) Test Plan (Rev. 6)
Ex-vessel debris coolability is an important light water reactor (LWR) safety issue. For existing plants, resolution of this issue will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this issue will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence and data for various cooling mechanisms through separate effect tests for severe accident model development, and ii) provide long-term 2-D core-concrete interaction data for code assessment and improvement. The PRG recommends that the OA design a 70 cm x 70 cm test, with two concrete side walls, using CEA siliceous concrete, 6 wt% concrete composition, early top flooding initiated when ablation is established and melt temperature has stabilized. The melt depth shall be 30 cm. The test will be designed for two specific phases. The first phase will provide for 30 cm for radial ablation and 25 cm for vertical ablation. In the event that the melt is not cooled down by top flooding during the first phase, a second and separate test phase will begin involving bottom flooding. This second phase will be initiated when axial ablation depth reaches 25 cm. The design should be mindful of the curing time of the concrete. The instrumentation should be refined to provide data on the water injection characteristics and melt temperature near the lateral walls. In response to this recommendation, the objective of this document is to provide a summary test plan for this sixth Core-Concrete Interaction (CCI-6) experiment for PRG review. Test specifications that were developed as part of the design work are provided.
New approaches for metabolomics by mass spectrometry
Small molecules constitute a large part of the world around us, including fossil and some renewable energy sources. Solar energy harvested by plants and bacteria is converted into energy rich small molecules on a massive scale. Some of the worst contaminants of the environment and compounds of interest for national security also fall in the category of small molecules. The development of large scale metabolomic analysis methods lags behind the state of the art established for genomics and proteomics. This is commonly attributed to the diversity of molecular classes included in a metabolome. Unlike nucleic acids and proteins, metabolites do not have standard building blocks, and, as a result, their molecular properties exhibit a wide spectrum. This impedes the development of dedicated separation and spectroscopic methods. Mass spectrometry (MS) is a strong contender in the quest for a quantitative analytical tool with extensive metabolite coverage. Although various MS-based techniques are emerging for metabolomics, many of these approaches include extensive sample preparation that make large scale studies resource intensive and slow. New ionization methods are redefining the range of analytical problems that can be solved using MS. This project developed new approaches for the direct analysis of small molecules in unprocessed samples, as well as pushed the limits of ultratrace analysis in volume limited complex samples. The projects resulted in techniques that enabled metabolomics investigations with enhanced molecular coverage, as well as the study of cellular response to stimuli on a single cell level. Effectively individual cells became reaction vessels, where we followed the response of a complex biological system to external perturbation. We established two new analytical platforms for the direct study of metabolic changes in cells and tissues following external perturbation. For this purpose we developed a novel technique, laser ablation electrospray ionization (LAESI), for metabolite profiling of functioning cells and tissues. The technique was based on microscopic sampling of biological specimens by mid-infrared laser ablation followed by electrospray ionization of the plume and MS analysis. The two main shortcomings of this technique had been limited specificity due to the lack of a separation step, and limited molecular coverage, especially for nonpolar chemical species. To improve specificity and the coverage of the metabolome, we implemented the LAESI ion source on a mass spectrometer with ion mobility separation (IMS). In this system, the gas phase ions produced by the LAESI source were first sorted according to their collisional cross sections in a mobility cell. These separated ion packets were then subjected to MS analysis. By combining the atmospheric pressure ionization with IMS, we improved the metabolite coverage. Further enhancement of the non-polar metabolite coverage resulted from the combination of laser ablation with vacuum UV irradiation of the ablation plume. Our results indicated that this new ionization modality provided improved detection for neutral and non-polar compounds. Based on rapid progress in photonics, we had introduced another novel ion source that utilized the interaction of a laser pulse with silicon nanopost arrays (NAPA). In these nanophotonic ion sources, the structural features were commensurate with the wavelength of the laser light. The enhanced interaction resulted in high ion yields. This ultrasensitive analytical platform enabled the MS analysis of single yeast cells. We extended these NAPA studies from yeast to other microorganisms, including green algae (Chlamydomonas reinhardtii) that captured energy from sunlight on a massive scale. Combining cellular perturbations, e.g., through environmental changes, with the newly developed single cell analysis methods enabled us to follow dynamic changes induced in the cells. In effect, we were able to use individual cells as a “laboratory,” and approached the long-standing goal of establishing a “lab-in-a-cell.” Model systems for these studies included cells of cyanobacteria (Anabaena), yeast (Saccharomyces cerevisiae), green algae (C. reinhardtii) and Arabidopsis thaliana.
Maximum credibly yield for deuteriuim-filled double shell imaging targets meeting requirements for yield bin Category A
We are anticipating our first NIF double shell shot using an aluminum ablator and a glass inner shell filled with deuterium shown in figure 1. The expected yield is between a few 10 10 to a few 10 11 dd neutrons. The maximum credible yield is 5e+13. This memo describes why, and what would be expected with variations on the target. This memo evaluates the maximum credible yield for deuterium filled double shell capsule targets with an aluminum ablator shell and a glass inner shell in yield Category A (< 10 14 neutrons). It also pertains to fills of gas diluted with hydrogen, helium ( 3 He or 4 He), or any other fuel except tritium. This memo does not apply to lower z ablator dopants, such as beryllium, as this would increase the ablation efficiency. This evaluation is for 5.75 scale hohlraum targets of either gold or uranium with helium gas fills with density between 0 and 1.6 mg/cc. It could be extended to other hohlraum sizes and shapes with slight modifications. At present only laser pulse energies up to 1.5 MJ were considered with a single step laser pulse of arbitrary shape. Since yield decreases with laser energy for this target, the memo could be extended to higher laser energies if desired. These maximum laser parameters of pulses addressed here are near the edge of NIF’s capability, and constitute the operating envelope for experiments covered by this memo. We have not considered multiple step pulses, would probably create no advantages in performance, and are not planned for double shell capsules. The main target variables are summarized in Table 1 and explained in detail in the memo. Predicted neutron yields are based on 1D and 2D clean simulations.
Path Integral Monte Carlo Simulations of Iron Plasmas (Final Technical Report)
This documents is the final technical report for our grant entitled "Path Integral Monte Carlo Simulations of Iron Plasmas" that focused on developing path integral Monte Carlo (PIMC) computer simulations. This techniques will be developed to study plasmas composed of heavier elements including iron and other third row elements. Equations of state (EOS) and transport properties will be derived in the regime of warm dense matter (WDM) and dense plasmas where existing first-principles methods cannot be applied. While standard density functional theory (DFT) has been used to accurately predict the structure of many solids and liquids up to temperatures on the order of 100,000 K, this method is not applicable at much higher temperature because the number of partially occupied electronic orbitals reaches intractably large numbers or the use of finite-temperature free energy functionals in orbital-free DFT introduces an uncontrolled approximation. Here we focus on PIMC methods that become more and more efficient with increasing temperatures and still include all electronic correlation effects. In this approach, electronic excitations increase the efficiency rather than reduce it. While it had commonly been assumed this method could only be applied to elements without core electrons, we showed that PIMC with free-particle nodes works well for first-row elements (PRL 108 (2012) 115502). Most recently, we extended the applicability range of all-electron PIMC to second-row elements by adopting localized nodal surfaces (PRL 115 (2015) 176403). To simulate third-row elements efficiently under WDM conditions, we propose a new method to remove core electrons by introducing pseudo-nodes. We explain our approach step by step and present preliminary results. We focus our method development on getting PIMC simulations of iron to work because of its fundamental importance for WDM and astrophysics. Then we move on to krypton and copper-doped beryllium, a ICF ablator material. We plan to continue working on key second-row material such as Na, Mg, MgO, Al, silica, and silicon-doped plastic ablators. Our collaborators at LLNL, will use our PIMC EOS data both as comparisons to existing semi-empirical, EOS-generating schemes, and as input for continuum radiation hydrodynamics simulations. We will establish an efficient pipeline from PIMC to macroscopic continuum studies of materials response. An emphasis will be placed on benchmarking such methods for plasmas of heavy elements at the very high temperatures (~100 eV) and low densities that are generated when Hohlraum radiation heats the ablator material in indirect drive laser experiments. Results from changes to the EOS will be of immeasurable importance to the designers at the National Ignition Facility (NIF) and at other facilities. Starting with our EOS of Cu-doped Be, our second collaborator at LLE, will perform real-time simulations of laser fusion experiments at the Omega laser and at the NIF to determine how sensitive the compression path depends on the ablator EOS. Since our collaborator also has experience in performing orbital-free DFT calculations, we propose to compare predictions from this method with PIMC results. In joint publications, we plan to analyze the accuracy of different free-energy functionals in order to understand why existing orbital-free DFT calculations do not predict compression peaks along the shock Hugoniot curve that we see with PIMC. The peaks are caused by the ionization of various electron shells. Their accurate characterization is important to compare with experimental results. We will break new ground by developing PIMC techniques that can simulate iron and all other third row elements in the plasma and WDM regimes. We introduce the concept of pseudo-nodes for the efficient treatment of the core-electrons. The EOS and transport properties will be derived and published online in the form of a new WDM database. Our PIMC EOS calculations will benchmark and possibly replace semi-analytical EOS tables like QEOS or SESAME, which will impact the hydrocode simulation community and will affect the design of NIF targets. Our PIMC results will help to improve the accuracy of orbital-free DFT simulations.
NucD-24 Nuclear Diagnostics Development: Time resolved 12 C-rhoR on GCD and NIS technology development for polar LOS and data quality [Slides]
The Neutron Imaging team is readying for the NIS2 polar LOS development and future improvements to data quality on all LOS given consistently higher yields at NIF. Next-gen nano guide scintillators for NIS2 and CMOS cameras to replace outdated CCDs will be studied. Digital image plates will be tested for better data quality on passive imaging systems. The transition into the ignition regime is expected to show a significant signature in the ablator areal density. In the marginal ignition regime, a decrease of 12C-rhoR (ablator areal density) is expected but once the burn propagation produces a shock and compresses the ablator the trend reverses. GCD with the PD-PMT can resolve this effect in the ablator areal density by a temporal shift in the carbon signal. To give quantitative results a calibration of the detector for the Hohlraum/TMP signal is needed. Shots using Al, Si, and Au pucks will yield the needed information to move forward with this project.
Towards Portable Laser Desorption Postionization Mass Spectrometry Utilizing Microchip Laser Pulses
A 355 nm, 1.5 ns, up to 1 kHz microchip laser system has been tested to both yield ablation spots and postionize material within a plasma plume. A 30 µJ pulse energy microchip laser successfully ablated all samples: 6601 aluminum, 316 and 304 stainless steel, and Mo metal. While visible ablation craters were observed on all samples mentioned above, the stainless-steel samples displayed visible color changes in the resolidified iron, indicating ionization with the 355 nm pulses during ablation. Additionally, when used to intercept a plasma plume of Cs 2 CO 3 made with a separate laser system, the microchip laser pulses yielded Cs + emission signal otherwise not observed. With these experiments completed, the microchip laser has been successfully verified for readiness to be integrated into the front end of a mass spectrometer system as the ion source.
Assessment of tissue or lesion depth using temporally resolved light scattering spectroscopy
A method is described to enhance the ability to evaluate the depth of a tissue component or a lesion having optical properties different from a surrounding tissue using time resolved optical methods. This invention may be particularly suitable for the evaluation of lesion depth during RF ablation (irreversible tissue modification/damage) using specially designed devises (catheters) that deliver heat in a localized region for therapeutic reasons. The technique allows for increased ability to evaluate the depth of the ablated lesion or detect the presence of other processes such as micro-bubble formation and coagulation with higher sensitivity compared to that offered by steady state spectroscopy. The method can be used for in-vivo, real-time monitoring during tissue ablation or other procedures where information on the depth of a lesion or tissue is needed. Exemplary uses are found in tissue ablation, tissue thermal damage, lesion and tissue depth assessment in medical applications.
LASER-BASED MEASUREMENT TOOLS FOR FUTURE ENRICHMENT PLANT SAFEGUARDS
The International Atomic Energy Agency (IAEA) has a long history of testing and using laser-based technologies for a variety of safeguards applications. Notable laser-based on-site applications include: 3-dimensional laser range (3DLR) instruments, used for facility design information and verification (DIV); laser measurements to verify unique labels and detect signs of tampering; and laser spectroscopy, for non-contact process monitoring. The IAEA is also evaluating analytical laboratory instruments, such as laser-ablation inductively-coupled plasma mass spectrometry (LA-ICP-MS) for interrogating individual particles to determine uranium isotopic ratios in collected environment samples. Recent laser technology advancements will likely continue to fuel future IAEA adoption of new and novel laser-based safeguards tools. The Pacific Northwest National Laboratory (PNNL) is currently developing one such tool, called laser ablation, absorption ratio spectrometry (LAARS), for quantitative measurements of uranium material. LAARS uses three tunable diode lasers to simultaneously measure atomic 235U and 238U absorption in an ablation plume created by a fourth pulsed laser. Commercial availability of compact pulsed ablation lasers and the extreme wavelength accuracy and stability of PNNL’s tunable diode laser architecture play a pivotal role in achieving high fidelity LAARS assay measurements. The LAARS method is ultimately targeted for either on-site or laboratory-based 235U relative abundance measurements of destructive assay (DA) samples in support of uranium enrichment plant safeguards. DA samples are currently collected on-site, and then shipped to an analytical laboratory for mass spectrometric assay, because the measurement uncertainty requirements for this application are quite challenging. This paper will present the key elements of the LAARS laser system design, recent assay results on collected uranium hexafluoride (UF6) DA samples, and future operational configurations that may provide immediate on-site DA inspection results or rapid laboratory DA sample screening to prioritize further analysis by mass spectrometry.
Near‐UV laser treatment of extrinsic dental enamel stains
Abstract Background and Objectives The selective ablation of extrinsic dental enamel stains using a 400‐nm laser is evaluated at several fluences for completely removing stains with minimal damage to the underlying enamel. Study Design/Materials and Methods A frequency‐doubled Ti:sapphire laser (400‐nm wavelength, 60‐nanosecond pulse duration, 10‐Hz repetition rate) was used to treat 10 extracted human teeth with extrinsic enamel staining. Each tooth was irradiated perpendicular to the surface in a back‐and‐forth motion over a 1‐mm length using an ∼300‐µm‐diam 10th‐order super‐Gaussian beam with fluences ranging from 0.8 to 6.4 J/cm 2 . Laser triangulation determined stain depth and volume removed by measuring 3D surface images before and after irradiation. Scanning electron microscopy evaluated the surface roughness of enamel following stain removal. Fluorescence spectroscopy measured spectra of unbleached and photobleached stains in the spectral range of 600–800 nm. Results Extrinsic enamel stains are removed with laser fluences between 0.8 and 6.4 J/cm 2 . Stains removed on sound enamel leave behind a smooth enamel surface. Stain removal in areas with signs of earlier cariogenic acid attacks resulted in isolated and randomly located laser‐induced, 50‐µm‐diam enamel pits. These pits contain 0.5‐µm diam, smooth craters indicative of heat transfer from the stain to the enamel and subsequent melting and water droplet ejection. Ablation stalling of enamel stains is typically observed at low fluences (<3 J/cm 2 ) and is accompanied by a drastic reduction in porphyrin fluorescence from the Soret band. Conclusion Laser ablation of extrinsic enamel stains at 400 nm is observed to be most efficient above 3 J/cm 2 with minimal damage to the underlying enamel. Unsound underlying enamel is also observed to be selectively removed after irradiation. Lasers Surg. Med. 44:339–345, 2012. © 2012 Wiley Periodicals, Inc.
Bland Embolization of Hepatocellular Carcinoma Using Superabsorbent Polymer Microspheres
The purpose of this study was to investigate the clinical outcomes of bland embolization using superabsorbent polymer microspheres (SAP-TAE) as an initial therapeutic option for previously untreated hepatocellular carcinoma (HCC) ineligible for resection or ablation. Fifty-nine patients with previously untreated HCC unamenable to surgery or ablation underwent bland embolization using 100- to 200-{mu}m reconstituted SAP particles (SAP-TAE) as the initial treatment. SAP-TAE was repeated as needed based on tumor response but was switched to chemoembolization when necessary to control residual or progressive tumor. Early tumor response was assessed by contrast-enhanced CT according to RECIST and EASL criteria 1 month after the initial SAP-TAE. The overall survival was calculated using the Kaplan-Meier method. The overall mean follow-up period was 30.6 months (range, 7-59 months). A total of 121 sessions of SAP-TAE were performed, with 1-5 sessions per patient (mean, 2.1 sessions). The mean period of repeated SAP-TAE was 15.6 months (range, 1-51 months), and it exceeded 1 and 2 years in 32 (54%) and 15 (25%) patients, respectively. Thirteen (22%) patients underwent repeated SAP-TAE alone, and the remaining 46 (78%) patients underwent subsequent chemoembolization. No major complication was observed and postembolization syndrome was minimal after SAP-TAE in all patients. Response rate was 14% and 66% by RECIST and EASL criteria, respectively. Overall survival rates were 100% and 83% at 1 and 2 years, respectively, and median survival time was 30 months. In conclusion, SAP-TAE was a safe and repeatable option as the induction therapy for HCC unamenable to surgery or ablation, despite the high incidence of converting to TACE during the total course.
Prospective Analysis of the Safety and Efficacy of Percutaneous Cryoablation for pT1NxMx Biopsy-Proven Renal Cell Carcinoma
Purpose: Our objective was to determine the efficacy and safety of image-guided, percutaneous cryoablation for American Joint Committee on Cancer pT1ANxMx and pT1BNxMx biopsy-proven renal cell carcinoma (RCC). Materials and Methods: Computed tomography (CT)-guided, percutaneous cryoablation was used to treat 117 renal lesions in 113 consecutive patients with pT1NxMx RCC. All 117 ablations were included in the safety analysis, and complications were categorized according to Common Terminology Criteria for Adverse Events version 3.0 (CTCAE v3.0). Eighty-one lesions were biopsy-proven RCC and were included in the efficacy analysis. Technical success was defined as the 'ice-ball' covering the entire lesion plus a minimum 5-mm margin. Efficacy was defined as complete lack of enhancement and continuous decrease in size on subsequent follow-up imaging studies. Results: Technical success was 100%, with 15% of ablations requiring air or saline injection to prevent nontarget ablation. We recorded a 7% rate of clinically significant complications (CTCAE category {>=}2) and 0% mortality. Renal function was not adversely affected. Seventy percent of patients were discharged to home on the same day. Efficacy was 98.7% for a median follow-up of 67 weeks (range 7-172). For the subgroup of patients that reached a median follow-up of 2 (n = 59) and 3 years (n = 13), efficacy was 98.3 and 92.3%, respectively. Cancer specific survival was 100%. Conclusions: CT-guided, percutaneous cryoablation has an excellent safety and efficacy profile for stage T1A and T1B RCC; however, longer follow-up is needed to compare it with other nephron-sparing surgical treatments. It is a great option for nonsurgical patients, those in whom renal function cannot be further sacrificed, and those at risk for metachronous lesions.
Irreversible Electroporation of Renal Cell Carcinoma: A First-in-Man Phase I Clinical Study
Purpose: Irreversible electroporation (IRE) is a newly developed nonthermal tissue-ablation technique in which high-voltage electrical pulses of microsecond duration are applied to induce irreversible permeabilisation of the cell membrane, presumably through nanoscale defects in the lipid bilayer, leading to apoptosis. The purpose of this study was to assess the feasibility and safety of ablating renal cell carcinoma (RCC) tissue by IRE. Methods: Six patients scheduled for curative resection of RCC were included. IRE was performed during anaesthesia immediately before the resection with electrographic synchronisation. Central haemodynamics were recorded before and 5 min after electroporation. Five-channel electrocardiography (ECG) was used for detailed analysis of ST waveforms. Blood sampling and 12-lead ECG were performed before, during, and at scheduled intervals after the intervention. Results: Analysis of ST waveforms and axis deviations showed no relevant changes during the entire study period. No changes in central haemodynamics were seen 5 min after IRE. Similarly, haematological, serum biochemical, and ECG variables showed no relevant differences during the investigation period. No changes in cardiac function after IRE therapy were found. One case of supraventricular extrasystole was encountered. Initial histopathologic examination showed no immediate adverse effects of IRE (observation of delayed effects will require a different study design). Conclusion: IRE seems to offer a feasible and safe technique by which to treat patients with kidney tumours and could offer some potential advantages over current thermal ablative techniques.
Urinary Tract Effects After Multifocal Nonthermal Irreversible Electroporation of the Kidney: Acute and Chronic Monitoring by Magnetic Resonance Imaging, Intravenous Urography and Urinary Cytology
Purpose: The nonthermal irreversible electroporation (NTIRE) is a novel potential ablation modality for renal masses. The aim of this study was the first evaluation of NTIRE's effects on the renal urine-collecting system using intravenous urography (IVU) and urinary cytology in addition to histology and magnetic resonance imaging (MRI). Methods: Eight percutaneous NTIRE ablations of the renal parenchyma, including the calyxes or pelvis, were performed in three male swine. MRI, IVU, histology, and urinary cytology follow-ups were performed within the first 28 days after treatment. Results: MRI and histological analysis demonstrated a localized necrosis 7 days and a localized scarification of the renal parenchyma with complete destruction 28 days after NTIRE. The urine-collecting system was preserved and showed urothelial regeneration. IVU and MRI showed an unaltered normal morphology of the renal calyxes, pelvis, and ureter. A new urinary cytology phenomenon featured a temporary degeneration by individual vacuolization of detached transitional epithelium cells within the first 3 days after NTIRE. Conclusions: This first urographical, urine-cytological, and MRI evaluation after porcine kidney NTIRE shows multifocal parenchyma destruction while protecting the involved urine-collecting system with regenerated urothelial tissue. NTIRE could be used as a targeted ablation method of centrally located renal masses.