Structural Analysis Findings of Open Spelter Socket Cable Terminations

A three-dimensional nonlinear finite element model of a representative open spelter socket termination was developed to examine the underlying mechanics of load transfer from a structural cable through the termination, the sensitivity of the joint design to wire brooming, zinc material nonlinearity, contact friction between the zinc and socket, voids within the zinc, and, finally, the effects of repeated loading on the joint. Primary factors affecting open spelter socket design are cast zinc plastic flow, depth of zinc slug seating, and quality of wire brooming. Zinc plasticity and proper brooming allows for efficient load transfer by developing confining pressure on the broomed wires in the narrow part of the socket, which keep the wires from pulling out of the zinc and shift failure to occur outside the socket. Highest wire stresses in the cable occur in the outer ring adjacent to the termination. While industry use of stay cables are typically designed to carry less than half the rated breaking force in aggregate, the constituent stresses within the zinc and the wires have the potential to exceed their respective allowable in operation and should be evaluated for fatigue- and creep-critical applications.

Pavel Babuska↗

Multi-core high-temperature, irradiation-resistant thermocouple, and related methods

A multi-core thermocouple includes a plurality of wires, an insulation core surrounding the plurality of wires, a sheath surrounding the insulation core, and a plurality of electrical junctions. The plurality of electrical junctions may include a first electrical junction formed between a first wire of the plurality of wires and the sheath at a first axial mid-section of the multi-core thermocouple, the first electrical junction including a first swaged axial mid-section of the sheath and a second electrical junction formed between a second wire of the plurality of wires and the sheath at a second, different axial mid-section of the multi-core thermocouple, the second electrical junction including a second swaged axial mid-section of the sheath.

Skifton, Richard S.↗

Iron nitride permanent magnet and technique for forming iron nitride permanent magnet

A permanent magnet may include a Fe 16 N 2 phase constitution. In some examples, the permanent magnet may be formed by a technique that includes straining an iron wire or sheet comprising at least one iron crystal in a direction substantially parallel to a <001> crystal axis of the iron crystal; nitridizing the iron wire or sheet to form a nitridized iron wire or sheet; annealing the nitridized iron wire or sheet to form a Fe 16 N 2 phase constitution in at least a portion of the nitridized iron wire or sheet; and pressing the nitridized iron wires and sheets to form bulk permanent magnet.

Wang, Jian-Ping↗

Irradiation effects in tungsten—From surface effects to bulk mechanical properties

Advanced materials such as tungsten fibre-reinforced composites allow to overcome severe weaknesses of the baseline materials for plasma-facing components — copper and tungsten. The effect of the fusion environment on the mechanical properties of these materials, e.g. the embrittlement by neutron irradiation, plays a key role for the development of future fusion reactors. To simulate this effect, high-energy ions are used as a substitute for the displacement damage by neutrons. We propose the use of very fine tungsten wire as a possibility of studying the influence of irradiation damage on the mechanical properties. This is possible as they allow full-depth irradiation of almost the entire volume despite the limited penetration depth of ions. Geometrical size effects are mitigated due to the nanoscale microstructure of the wire. In addition, similar wire is used in tungsten fibre-reinforced composites. Thus, the investigation of irradiated wire can directly be used for the prediction of the bulk composite properties. For the proof of this concept tungsten wire with a diameter of 16 μm was electrochemically thinned to 5 μm and irradiated with 20.5 MeV W 6+ ions. The mechanical properties were subsequently determined by macroscopic tensile testing. Irradiation to 0.3, 1 and 9 dpa did not lead to a change of the mechanical behaviour. Both strength and ductility, the latter indicated by the reduction of area, were similar to the as-fabricated state.

36 MATERIALS SCIENCE↗

Simulation of two nanoparticle melting to understand the conductivity drop of 3D-printed silver nanowires

The future flexible sensor technology will require low-temperature, fast processing 3D printing techniques that will rely heavily on the quality of nanoparticle (NP) Ink. Electrical conductivity has been found to decrease in majority of the 3D printed electronic wires. Herein we report a fundamental understanding in drop of electrical conductivity in processed silver (Ag) line wire, generally found in Ag-nanoparticle Ink, using large-scale atomistic molecular dynamics (MD) simulations of sintering of five different sizes of Ag NPs. To preserve the high conductivity of pure silver wires, the integrity of the pristine face-centered cubic (FCC) crystalline structure must be retained in the processed line wires. Simulations show that the pristine Ag FCC structures of the nanoparticles are not recovered after melting and resolidification, instead, the resolidified material is paracrystaline. The breakdown of pristine FCC structures might be the cause of the drop in conductivity of processed Ag wires. Simulation results suggest that the intermediate size nanoparticles retain highest percentage of the pristine silver face-centered cubic (FCC) structure after pulse treatments. Our results show that the most promising Ag-Ink should contain smaller to medium size silver NPs that can retain FCC structure after 3D printing of the Ag-Ink.

42 ENGINEERING↗

APC Nb 3 Sn superconductors based on internal oxidation of Nb–Ta–Hf alloys

In the last few years, a new type of Nb 3 Sn superconducting composite, containing a high density of artificial pinning centers (APC) generated via an internal oxidation approach, has demonstrated a significantly superior performance relative to present, state-of-the-art commercial Nb3Sn conductors. This was achieved via the internal oxidation of Nb-4at.%Ta-1at.%Zr alloy. On the other hand, our recent studies have shown that internal oxidation of Nb–Ta–Hf alloys can also lead to dramatic improvements in Nb 3 Sn performance. Here in this work we follow up on this latter approach, fabricating a 61-stack APC wire based on the internal oxidation of Nb-4at.%Ta-1at.%Hf alloy, and compare its critical current density (J c ) and irreversibility field with APC wires made using Nb-4at.%Ta-1at.%Zr. A second goal of this work was to improve the filamentary design of APC wires in order to improve their wire quality and electromagnetic stability. Our new modifications have led to significantly improved residual resistivity ratio and stability in the conductors, while still keeping non-Cu J c at or above the conductor J c specification required by the proposed Future Circular Collider. Further improvement via optimization of the wire recipe and design is ongoing. Finally, additional work needed to make APC conductors ready for applications in magnets is discussed.

43 PARTICLE ACCELERATORS↗

Evidence of Kramer extrapolation inaccuracy for predicting high field Nb 3 Sn properties

Future applications requiring high magnetic fields, such as the proposed Future Circular Collider, demand a substantially higher critical current density, J c , at fields ≥16 T than is presently available in any commercial strand, so there is a strong effort to develop new routes to higher J c Nb 3 Sn. As a consequence, evaluating the irreversibility field (H irr ) of any new conductor to ensure reliable performance at these higher magnetic fields becomes essential. To predict the irreversibility field for Nb 3 Sn wires, critical current measurements, I c , are commonly performed in the 12-15 T range and the Kramer extrapolation is used to predict higher field properties. Here, the Kramer extrapolation typically models the contribution only for sparse grain boundary pinning, yet Nb 3 Sn wires rely on a high density of grain boundaries to provide the flux pinning that enables their high critical current density. However, whole-field range VSM measurements up to 30 T recently showed for Nb 3 Sn RRP® wires that the field dependence of the pinning force curve significantly deviates from the typical grain boundary shape, leading to a 1-2 T overestimation of Hirr when extrapolated from the typical mid-field data taken only up to about 15 T. In this work we characterized a variety of both RRP® and PIT Nb 3 Sn wires by transport measurements up to 29 T at the Laboratoire National des Champs Magnétiques Intenses (LNCMI), part of the European Magnetic Field Laboratory in Grenoble, to verify whether or not such overestimation is related to the measurement technique and whether or not it is a common feature across different designs. Indeed we also found that when measured in transport the 12-15 T Kramer extrapolation overestimates the actual H irr in both types of conductor with an inaccuracy of up to 1.6 T, confirming that high field characterization is a necessary tool to evaluate the actual high field performance of each Nb 3 Sn wire.

36 MATERIALS SCIENCE↗

Studies and optimization of hybrid X-pinches

Studies were carried out on the hybrid X-pinch (HXP) configuration for several wire materials using a 40ns risetime, 300-kA pulsed-power generator with the goal of optimizing the HXP X-ray burst parameters for different applications. The gap distance between the conical electrodes of the hybrid X-pinch was varied from 0.5 to 5 mm for Al, Ag, Ti, and Mo using different wire diameters to maintain a consistent mass per unit length from one material to the next. It was found that 0.5 - 1 mm gap spacing was optimal to obtain a single X-ray burst, while the number of X-ray bursts increased with gap spacing for all materials at a rate of 1-2/mm. Time consistency studies of the first X-ray burst were carried out for Ti wire by changing the gap distance and wire diameter while observing the time of occurrence of the X-ray bursts. Here, it was found that a 40μm Ti wire load with a 3mm electrode gap spacing had the highest probability to have the first X-ray burst reproducibly within a 2 ns time window. Time-resolved and time-integrated diagnostics provided information about the source size, time of occurrence, intensity, and the number of the X-ray bursts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Low Loss, Fast Ramp HTS Solenoid Prototype for Compact Spherical Tokamaks

To explore AC loss characteristics of commercial Bi-2212 conductors made in the USA, a small ohmic heating (OH) prototype coil is being developed for compact tokamaks using high performance Bi-2212 wires newly manufactured by Bruker EST. Here, the goal is to build and test Bi-2212 prototype coils for fast ramp central solenoid (CS) operation of spherical tokamaks (ST). For a ST pilot plant, one of the key challenges is the tight space available for CS in a center column where in-board legs of the toroidal field (TF) and OH coils are assembled into a cryostat with a few millimeters clearance. A high current density Rutherford cable consisting of 17 legacy Bi-2212 wires, a contribution of the US Magnet Development Program (MDP), was fabricated at the Lawrence Berkeley National Laboratory (LBNL) for the development of fast ramp CS magnets in the ST Advanced Reactor (STAR) designed by PPPL. Characterization of the new and legacy HTS wires is presented, along with the coil design wound directly with new wire, and a Rutherford cable-wound solenoid using the legacy wire. A comparison of AC losses is made based on expected performance for a fast ramp ST operation. The HTS cable and cabled coil fabrication issues such as the heat treatment, coil mandrel design, assembly and 2212 quench characteristics are discussed, along with a test plan for CS design validation.

Zhai, Yuhu [Princeton Plasma Physics Laboratory (P↗

Lightning Current Propagation in Electrical Conduit

Investigation of lightning strikes to conductors ran through long spans of rigid steel conduit was performed. An overdamped-exponential current waveform with controlled peaks and rise rates was used to inject simulated lightning strikes. The impact of the length of wire, length of conduit, grounding location/s, and load type was investigated. Breakdown of 600 V, 12 AWG, THHN insulated wire (3.23 mm OD, 2 mm conductor diameter) was observed for voltages above 45 kV. The presence of resistive loads (between wire and ground) in excess of 20 ohms, or current rise times in excess of 5 kA/μs were found to consistently produce breakdown between wire and conduit. Practical power circuit elements such as outlets and splices were found to breakdown at voltage levels much below the wire insulation failure threshold.

47 OTHER INSTRUMENTATION↗

Effects of delta ray electrons on measurement uncertainties of harp system

A harp system, which is a multi-wire beam profile monitoring (MWPM) system, is planned upstream of the spallation target to make in situ calibration of beam current density configuration on the target along with beam imaging from luminescent coating on the beam entrance window at the Second Target Station (STS) of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). This beam interception-based beam diagnostics system on the target will be used to ensure that the maximum beam loads on the target are within the design range during neutron production. Current design of the harp consists of three layers of measurement wires each of which is sandwiched between voltage biasing wire planes. The signal obtained from each measurement wire layer is disturbed by secondary electrons (SE) and delta rays produced by beam-matter interactions in neighboring wires and ionization of residual gases in accelerator vacuum. While the backgrounds from SE can be suppressed by voltage biasing, the delta-ray electrons with kinetic energies above keV ranges overcome the electric potential bias. In this paper, we study the effects of delta-rays on the measurement uncertainties of MWPM using the particle transport simulation code FLUKA. Furthermore, the cases where the harp system is installed in the proximity of a large delta ray sources such as proton beam window or in the core vessel filled with sub-atmospheric gas have been studied.

Lee, Yong Joong↗

Physics Considerations for a Harp System Design at the Second Target Station of the Spallation Neutron Source

A harp system is being developed for monitoring proton beam profile direct upstream of the proton beam window at the Second Target Station of the Spallation Neutron Source, Oak Ridge National Laboratory. It consists of two sensor planes which have arrays of thin conducting wires aligned vertically and horizontally, respectively. It monitors beam profiles in two transverse directions to the beam axis by measuring the net-charge depositions in the sensor wires, which are caused by ejection of secondary electrons and delta rays driven by electromagnetic interactions with high energy protons. The net charge deposition in a sensing wire linearly correlates with the number of incident protons on it. This correlation is perturbed when the wire interacts with secondary electrons and delta rays originating from beam matter interactions in neighboring wires, PBW and residual gases. In this paper, we analyze the physical phenomena that affects the measurement uncertainties of the harp using particle transport simulations.

Lee, Yong Joong [ORNL] (ORCID:0000000298381723)↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Aluminum 4047 Vendor Review [Slides]

The selected filler wire manufacturer should have full control of the filler wire manufacturing process (i.e. ingot metal, green rod, filler wire manufacturing and packaging). LANL would like to purchase filler wire as an off-the-shelf product in small quantities over time to maintain a fresh stock and eliminate issues related to long-term storage of aluminum. The filler wire would be purchased in 0.047” dia. on small (ideally 5 lb.) spools, but no larger than 16 lbs.

36 MATERIALS SCIENCE↗

Development of automatic through-insulation welding for microelectric interconnections

The capability to automatically route, remove insulation from, and weld small-diameter solid conductor wire is presented. This would facilitate the economical small-quantity production of complex miniature electronic assemblies. An engineering model of equipment having this capability was developed and evaluated. Whereas early work in the use of welded magnet wire interconnections was concentrated on opposed electrode systems, and generally used heat to melt the wire insulation, the present method is based on a concentric electrode system and a wire feed system which splits the insulation by application of pressure prior to welding. The work deals with the design, fabrication, and evaluation testing of an improved version of this concentric electrode system. Two different approaches to feeding the wire to the concentric electrodes were investigated. It was concluded that the process is feasible for the interconnection of complex miniature electronic assemblies.

Arnett, J. C.↗

Miniature sheathed thermocouples for turbine blade temperature measurement

An investigation was made of sheathed thermocouples for turbine blade temperature measurements. Tests were performed on the Chromel-Alumel sheathed thermocouples with both two-wire and single-wire configurations. Sheath diameters ranged from 0.25 to 0.76 mm, and temperatures ranged from 1080 to 1250 K. Both steady-state and thermal cycling tests were performed for times up to 450 hr. Special-order and commercial-grade thermocouples were tested. The tests showed that special-order single-wire sheathed thermocouples can be obtained that are reliable and accurate with diameters as small as 0.25 mm. However, all samples of 0.25-mm-diameter sheathed commercial-grade two-wire and single-wire thermocouples that were tested showed unacceptable drift rates for long-duration engine testing programs. The drift rates were about 1 percent in 10 hr. A thermocouple drift test is recommended in addition to the normal acceptance tests in order to select reliable miniature sheathed thermocouples for turbine blade applications.

Holanda, R.↗

Electrodynamics of long conducting tethers in the near-earth environment

An analytical approach was developed to evaluate the electrodynamic interactions affecting a thin, bare metallic wire moving in the ionosphere. The wire's diameter was smaller than the Debye length; therefore, the plasma sheath around the wire was taken into account in computing inducing drag force and torque. Computer programs were prepared for the numerical evaluation of mathematical functions that were required to compute the distribution of the potential along the wire and of the current in the wire. Numerical calculations based on this software are shown.