Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “vessel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Are Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm Applicable to Other Malignancies—Assessment of Nodal Distribution in Gynecological Malignancies

Purpose: Intensity modulated radiation therapy is used to reduce dose to adjacent critical structures while maintaining adequate target coverage, but it requires precise target localization. We report the 3-dimensional distribution of para-aortic (PA) lymph nodes (LN) in pelvic malignancies. We propose a guideline to accurately define the PA LN by anatomic landmarks and compare our data with published guidelines for pancreatic cancer. Methods and Materials: A retrospective analysis was performed on 46 patients with pelvic malignancies and positive PA LNs. Positive LNs were defined based on size and morphology or fluorodeoxyglucose avidity. All PA LNs were characterized into 3 groups based on location: left PA (between aorta and left psoas muscle), aortocaval (between aorta and inferior vena cava), and right paracaval (between inferior vena cava and right psoas muscle). Patients with retrocrural LNs were also analyzed. Results: One hundred thirty-three positive PA LNs were evaluated. The majority of the PA LNs were in the left PA (59%) and aortocaval (35) regions, and only 8% were in the right paracaval region. All patients with positive right paracaval LNs also had involved left PA LNs, with only 1 exception. The highest PA LN involvement was at the level of the renal vessels and was seen in 28% of patients. Of these patients with disease extending to renal vessels, 38% had retrocrural LN involvement. Conclusions: The nodal contouring for the PA region should not be defined by a fixed circumferential margin around the vessels. The left PA and aortocaval spaces should be covered adequately because these are common locations of PA LNs. For microscopic disease superiorly, contouring should extend up to renal vessels rather than a fixed bony landmark. For patients who have nodal involvement at renal vessels, one can consider including retrocrural LNs. Radiation Therapy Oncology Group Para-aortic Contouring Guidelines for Pancreatic Neoplasm are not applicable to gynecological malignancies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cavitation-induced erosion in liquid metal spallation targets – A comparison between a predictive method and measured erosion damage to stainless steel target modules at the Spallation Neutron Source

Neutrons are produced for neutron scattering instruments at the Spallation Neutron Source by bombarding liquid mercury with a pulsed high-energy proton beam. The liquid mercury target material flows through a replaceable stainless-steel target vessel and cavitates during operation due to the extremely high heating rate caused by each proton pulse. Cavitation-induced erosion damage to the mercury-facing surfaces of target vessels is a key concern for target lifetime and has been the subject of considerable research. While numerous experiments have studied and modeled the progression of cavitation erosion damage to liquid metal target containers, direct quantitative measurements of actual erosion of a spallation target vessel were previously not available. Recently, the erosion damage to multiple target vessels operated at the Spallation Neutron Source was measured using a high-resolution laser scanning system, which provided an opportunity to study the efficacy of a cavitation damage progression model. In this paper, a cavitation progression modeling procedure developed using empirical observations is compared to measurements of samples from target vessels after operation. We discuss the strengths and limitations of the technique and propose methods for improving future modeling and predictive accuracy.

36 MATERIALS SCIENCE↗

Mechanisms of soft tissue and protein preservation in Tyrannosaurus rex

Abstract The idea that original soft tissue structures and the native structural proteins comprising them can persist across geological time is controversial, in part because rigorous and testable mechanisms that can occur under natural conditions, resulting in such preservation, have not been well defined. Here, we evaluate two non-enzymatic structural protein crosslinking mechanisms, Fenton chemistry and glycation, for their possible contribution to the preservation of blood vessel structures recovered from the cortical bone of a Tyrannosaurus rex (USNM 555000 [formerly, MOR 555]). We demonstrate the endogeneity of the fossil vessel tissues, as well as the presence of type I collagen in the outermost vessel layers, using imaging, diffraction, spectroscopy, and immunohistochemistry. Then, we use data derived from synchrotron FTIR studies of the T. rex vessels to analyse their crosslink character, with comparison against two non-enzymatic Fenton chemistry- and glycation-treated extant chicken samples. We also provide supporting X-ray microprobe analyses of the chemical state of these fossil tissues to support our conclusion that non-enzymatic crosslinking pathways likely contributed to stabilizing, and thus preserving, these T. rex vessels. Finally, we propose that these stabilizing crosslinks could play a crucial role in the preservation of other microvascular tissues in skeletal elements from the Mesozoic.

59 BASIC BIOLOGICAL SCIENCES↗

Pre-ignition confinement and deflagration violence in LX-10 and PBX 9501

In thermal explosions of the nitramine octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX)-based explosives LX-10 and PBX-9501, the pre-ignition spatial and temporal heating profile defines the ignition location. The ignition location then determines the extent of inertial confinement and the violence of the resulting deflagration. In this work, we present results of experiments in which ∼23 g cylinders of LX-10 and PBX 9501 in thin-walled aluminum confinement vessels were subjected to identical heating profiles but which presented starkly different energy release signatures. Post-explosion LX-10 containment vessels were completely fragmented, while the PBX 9501 vessels were merely ruptured. Flash x-ray radiography images show that the initiation location for the LX-10 is a few mm farther from the end caps of the vessel relative to the initiation location of PBX 9501. This difference increases deflagration confinement for LX-10 at the time of ignition and extends the pressurization time during which the deflagration front propagates in the explosive. The variation in the initiation location, in turn, is determined by the thermal boundary conditions, which differ for these two explosives because of the larger coefficient of thermal expansion and greater thermal stability of the Viton binder in LX-10 relative to the estane and bis(2,2-dinitropropyl) acetal/formal binder of the PBX 9501. The thermal profile and initiation location were modeled for LX-10 using the hydrodynamics and structures code ALE3D; results indicate temperatures in the vicinity of the ignition location in excess of 274 °C near the time of ignition. The conductive burn rates for these two explosives, as determined by flash x-ray radiography, are comparable in the range 0.1–0.2 mm/μs, somewhat faster than rates observed by strand burner experiments for explosives in the temperature range 150–180 °C and pressures up to 100 MPa. The thinnest-wall aluminum containment vessels presented here rupture at lower pressures, in the range 10 MPa, suggesting that moderately higher temperatures and pressures are present near the deflagration front. For these explosives, however the most important property for determining deflagration violence is the degree of inertial confinement.

42 ENGINEERING↗

Demonstration of a two-dimensional divertor Thomson scattering system on DIII-D

Recent upgrades providing two-dimensional divertor Thomson scattering (DTS-2D) measurements of T e and n e during a DIII-D plasma shot and a thorough description of system components and their functionality are presented. This system expands the capabilities of the existing single divertor Floor measurement location by introducing seven additional laser beam path options in the poloidal plane, spanning major radii from 1.062 to 1.335 m. The system redirects ~1 J, 50 Hz Nd:YAG laser pulses to the new beam paths within 20 ms, stepping through each path on the divertor Floor every 200 ms during a plasma shot. The laser is redirected using an ex-vessel, fast-steering mirror to one of eight in-vessel beam paths oriented underneath the vessel tiles. Up to eleven measurement positions per beam path, from –1.35 to –1.13 m below the machine midplane, are available by dynamically refocusing the ex-vessel collection fiber array using a high-speed linear stage. As a result, current measurement positions above the divertor Shelf are retained via a hole in the fixed, in-vessel mirror, allowing laser pass through.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conceptual Design of the Transformational Challenge Reactor

The Transformational Challenge Reactor is a 3-MW(thermal) helium-cooled experimental nuclear reactor designed using an additive manufacturing–informed agile design process. This design process leverages rapid prototyping and advanced materials from emerging additive manufacturing technologies, key characteristics that enable rapid design maturation. The resulting core design incorporates a blend of advanced reactor technologies into an intermediate-spectrum microreactor, including conventionally manufactured tristructural isotropic (TRISO) fuel particles in an advanced manufactured SiC fuel element and a solid yttrium hydride moderator encapsulated in steel. Matured during the design effort, these technologies are incorporated with additively manufactured steel support and fluidic structures to form a 75-cm-outer-diameter cylindrical active core region. Below and above the active core region are axial SiC reflectors, which are housed inside the reactor pressure vessel. The reactor is controlled with an annular shroud actuated external to the pressure vessel in the gap between the pressure vessel and a steel radial reflector. A safety rod is at the center of the core to shut down the reactor when necessary. Helium pressurized at 5 MPa is forced into the pressure vessel below the core and around the core to the top plenum before it is forced down through the axial reflectors and the active core region. The primary pressurized helium loop is operated up to 500°C and includes the pressure vessel, the circulator, and the hot side of a helium-to-air heat exchanger. The secondary loop rejects all heat from the primary loop to ambient air through a heat exchanger. A vented temporary confinement building contains the entire primary loop, with penetrations for a stack, cooling, and the secondary ambient air loop. Finally, this is the first advanced nuclear microreactor designed using additive manufacturing technologies, demonstrating their applicability in an accelerated advanced design process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mass Optimization of a Multilayered Shield for Transportable Microreactors

The ability to easily transport microreactors is a major selling point for deploying microreactors to remote areas. However, this creates a unique shielding challenge, especially when the microreactor is being shipped after irradiation. A traditional reactor configuration utilizes a separate biological shield and pressure vessel to meet radiological shielding and pressure needs. The limited space available for transportable microreactors for both shielding and pressure vessels requires a revised assessment of separating out the biological shield and pressure vessel. To address these concerns, we examine a nuclear-grade sandwich composite (NGSC) that combines the reactor pressure vessel and biological shielding functions into a single component. Through a series of optimization problems for both transportation and operational use cases, the NGSC is able to minimize dose, minimize the vessel cost, and ensure that weight requirements are met for transportation. Initial results show that using a tungsten-tetraboride cermet in the first two layers of a six-layer NGSC provides adequate shielding for both use cases. These results show promise that an NGSC has enough overlap between operational and transportation cases to help reduce the design space for future analysis and assessment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Integral analysis of the effect of material dimension and composition on tokamak neutronics *

Abstract The neutronics performance of a tokamak has been identified as an important factor in designing a fusion power plant. The design of the tokamak should not only meet operational parameters such as sufficient tritium breeding, but also safety parameters such as low structural material activation. This paper investigates the impacts of the neutronics metrics for the ARC-class tokamak, a compact tokamak with an immersion blanket, by perturbing the first five layers of structural material—first wall, inner vacuum vessel, coolant salt channel, neutron multiplier, and outer vacuum vessel. The goal of this work is to provide insight into shaping and scaling the flux on each layer to obtain optimized operational and safety metrics through quantification of the responses from each perturbation. Results show that increased first wall thickness can increase the tritium breeding ratio (TBR) in specific configurations with high 6 Li enrichments and that vacuum vessels decrease TBR for low- 6 Li enrichment configurations. It was also found that the neutron multiplier can either increase or decrease TBR depending on the configuration. The response of metrics to the change in layer thickness and enrichment also varies depending on the vacuum vessel material. The integral impacts of 6 Li enrichment, layer thicknesses, and vacuum vessel material choice are investigated and presented in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

Purpose: The buildup of noncalcified plaques (NCPs) that are vulnerable to rupture in coronary arteries is a risk for myocardial infarction. Interpretation of coronary CT angiography (cCTA) to search for NCP is a challenging task for radiologists due to the low CT number of NCP, the large number of coronary arteries, and multiple phase CT acquisition. The authors conducted a preliminary study to develop machine learning method for automated detection of NCPs in cCTA. Methods: With IRB approval, a data set of 83 ECG-gated contrast enhanced cCTA scans with 120 NCPs was collected retrospectively from patient files. A multiscale coronary artery response and rolling balloon region growing (MSCAR-RBG) method was applied to each cCTA volume to extract the coronary arterial trees. Each extracted vessel was reformatted to a straightened volume composed of cCTA slices perpendicular to the vessel centerline. A topological soft-gradient (TSG) detection method was developed to prescreen for NCP candidates by analyzing the 2D topological features of the radial gradient field surface along the vessel wall. The NCP candidates were then characterized by a luminal analysis that used 3D geometric features to quantify the shape information and gray-level features to evaluate the density of the NCP candidates. With machine learning techniques, useful features were identified and combined into an NCP score to differentiate true NCPs from false positives (FPs). To evaluate the effectiveness of the image analysis methods, the authors performed tenfold cross-validation with the available data set. Receiver operating characteristic (ROC) analysis was used to assess the classification performance of individual features and the NCP score. The overall detection performance was estimated by free response ROC (FROC) analysis. Results: With our TSG prescreening method, a prescreening sensitivity of 92.5% (111/120) was achieved with a total of 1181 FPs (14.2 FPs/scan). On average, six features were selected during the tenfold cross-validation training. The average area under the ROC curve (AUC) value for training was 0.87 ± 0.01 and the AUC value for validation was 0.85 ± 0.01. Using the NCP score, FROC analysis of the validation set showed that the FP rates were reduced to 3.16, 1.90, and 1.39 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively. Conclusions: The topological soft-gradient prescreening method in combination with the luminal analysis for FP reduction was effective for detection of NCPs in cCTA, including NCPs causing positive or negative vessel remodeling. The accuracy of vessel segmentation, tracking, and centerline identification has a strong impact on NCP detection. Studies are underway to further improve these techniques and reduce the FPs of the CADe system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-E-17A-01: Characterization of An Imaging-Based Model of Tumor Angiogenesis

Purpose: Understanding the transient dynamics of tumor oxygenation is important when evaluating tumor-vasculature response to anti-angiogenic therapies. An imaging-based tumor-vasculature model was used to elucidate factors that affect these dynamics. Methods: Tumor growth depends on its doubling time (Td). Hypoxia increases pro-angiogenic factor (VEGF) concentration which is modeled to reduce vessel perfusion, attributing to its effect of increasing vascular permeability. Perfused vessel recruitment depends on the existing perfused vasculature, VEGF concentration and maximum VEGF concentration (VEGFmax) for vessel dysfunction. A convolution-based algorithm couples the tumor to the normal tissue vessel density (VD-nt). The parameters are benchmarked to published pre-clinical data and a sensitivity study evaluating the changes in the peak and time to peak tumor oxygenation characterizes them. The model is used to simulate changes in hypoxia and proliferation PET imaging data obtained using [Cu- 61]Cu-ATSM and [F-18]FLT respectively. Results: Td and VD-nt were found to be the most influential on peak tumor pO2 while VEGFmax was marginally influential. A +20 % change in Td, VD-nt and VEGFmax resulted in +50%, +25% and +5% increase in peak pO2. In contrast, Td was the most influential on the time to peak oxygenation with VD-nt and VEGFmax playing marginal roles. A +20% change in Td, VD-nt and VEGFmax increased the time to peak pO2 by +50%, +5% and +0%. A −20% change in the above parameters resulted in comparable decreases in the peak and time to peak pO2. Model application to the PET data was able to demonstrate the voxel-specific changes in hypoxia of the imaged tumor. Conclusion: Tumor-specific doubling time and vessel density are important parameters to be considered when evaluating hypoxia transients. While the current model simulates the oxygen dynamics of an untreated tumor, incorporation of therapeutic effects can make the model a potent tool for analyzing anti-angiogenic therapies.

60 APPLIED LIFE SCIENCES↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 09: Stability of a water calorimetry system as a primary standard for absorbed dose to water

Purpose: To investigate the stability of a water calorimetry system as a primary standard for absorbed dose to water using measurements performed in cobalt-60 and high-energy linac photon beams over a span of more than a decade. Methods: Calorimetry measures adsorbed dose directly by recording the amount of heat created when ionizing radiation passes through matter. The radiation-induced temperature rise was measured using two thermistors calibrated against the NRC temperature primary standard, using an AC bridge with lock-in amplifier for precise measurement. The calorimeter system was operated under thermal equilibrium at 4 °C (to eliminate convection) with drifts in water temperature less than 0.1 mK/min. Seven water vessels of various designs were used to make repeated measurements over the course of 17 years. Results: The standard uncertainty achieved for a set of ten calorimeter measurements (4 Gy delivered) was generally well below 0.15 % while the variation between multiple sets for a given vessel was consistent with this value. The long-term stability of the system combined with inter-vessel variations indicated that there was good control of the radiochemistry (chemical heat defect). Conclusions: The measurements performed over a period of several years showed that the combined water calorimeters showed stability at +/− 0.25 % level. Thus, rather than relying on a particular vessel as an artifact one can realize the Gray through the more generalized method of combining a glass vessel, high-purity water and thermistor probes. This provides increased robustness in the dissemination of absorbed dose to Canadian users.

60 APPLIED LIFE SCIENCES↗

DOSE ASSESSMENT OF THE FINAL INVENTORIES IN CENTER SLIT TRENCHES ONE THROUGH FIVE

In response to a request from Solid Waste Management (SWM), this study evaluates the performance of waste disposed in Slit Trenches 1-5 by calculating exposure doses and concentrations. As of 8/19/2010, Slit Trenches 1-5 have been filled and are closed to future waste disposal in support of an ARRA-funded interim operational cover project. Slit Trenches 6 and 7 are currently in operation and are not addressed within this analysis. Their current inventory limits are based on the 2008 SA and are not being impacted by this study. This analysis considers the location and the timing of waste disposal in Slit Trenches 1-5 throughout their operational life. In addition, the following improvements to the modeling approach have been incorporated into this analysis: (1) Final waste inventories from WITS are used for the base case analysis where variance in the reported final disposal inventories is addressed through a sensitivity analysis; (2) Updated K{sub d} values are used; (3) Area percentages of non-crushable containers are used in the analysis to determine expected infiltration flows for cases that consider collapse of these containers; (4) An updated representation of ETF carbon column vessels disposed in SLIT3-Unit F is used. Preliminary analyses indicated a problem meeting the groundwater beta-gamma dose limit because of high H-3 and I-129 release from the ETF vessels. The updated model uses results from a recent structural analysis of the ETF vessels indicating that water does not penetrate the vessels for about 130 years and that the vessels remain structurally intact throughout the 1130-year period of assessment; and (5) Operational covers are included with revised installation dates and sets of Slit Trenches that have a common cover. With the exception of the modeling enhancements noted above, the analysis follows the same methodology used in the 2008 PA (WSRC, 2008) and the 2008 SA (Collard and Hamm, 2008). Infiltration flows through the vadose zone are identical to the flows used in the 2008 PA, except for flows during the operational cover time period. The physical (i.e., non-geochemical) models of the vadose zone and aquifer are identical in most cases to the models used in the 2008 PA. However, the 2008 PA assumed a uniform distribution of waste within each Slit Trench (WITS Location) and assumed that the entire inventory of each trench was disposed of at the time the first Slit Trench was opened. The current analysis considers individual trench excavations (i.e., segments) and groups of segments (i.e., Inventory Groups also known as WITS Units) within Slit Trenches. Waste disposal is assumed to be spatially uniform in each Inventory Group and is distributed in time increments of six months or less between the time the Inventory Group was opened and closed.

54 ENVIRONMENTAL SCIENCES↗

Comparison of High Pressure Transient PVT Measurements and Model Predictions – Part I

A series of experiments consisting of vessel-to-vessel transfers of pressurized gas using Transient PVT methodology have been conducted to provide a data set for optimizing heat transfer correlations in high pressure flow systems. In rapid expansions such as these, the heat transfer conditions are neither adiabatic nor isothermal. Compressible flow tools exist, such as NETFLOW that can accurately calculate the pressure and other dynamical mechanical properties of such a system as a function of time. However to properly evaluate the mass that has transferred as a function of time these computational tools rely on heat transfer correlations that must be confirmed experimentally. In this work new data sets using helium gas are used to evaluate the accuracy of these correlations for receiver vessel sizes ranging from 0.090 L to 13 L and initial supply pressures ranging from 2 MPa to 40 MPa. The comparisons show that the correlations developed in the 1980s from sparse data sets perform well for the supply vessels but are not accurate for the receivers, particularly at early time during the transfers. This report focuses on the experiments used to obtain high quality data sets that can be used to validate computational models. Part II of this report discusses how these data were used to gain insight into the physics of gas transfer and to improve vessel heat transfer correlations. Network flow modeling and CFD modeling is also discussed.

99 GENERAL AND MISCELLANEOUS↗

CMR Shuffler System: Passive Mode Calibration and Certification Report

Los Alamos National Laboratory has a number of spherical confinement vessels (CVs) remaining from tests involving nuclear materials. These vessels have an inner diameter of 6 feet with 1 to 2 inch thick steel walls. The goal of the Confinement Vessel Disposition (CVD) project is to remove debris and reduce contamination inside the vessels. As debris is removed from the vessels, material will be placed in waste drums. Far-field gamma ray assay will be used to determine when a drum is nearing a 239 Pu equivalent mass of less than 200 g. The drum will then be assayed using a waste drum shuffler operated in passive mode using a neutron coincidence counting method for accountability. This report focuses on the testing and calibration of the CMR waste drum shuffler in passive mode operation. Initial testing was performed to confirm previously accepted measurement parameters. The system was then calibrated using a set of weapons grade Pu (WGPu, 239 Pu > 93%) oxide standards placed inside a 55 gallon drum. The calibration data ranges from Pu mass of 0.5 g to 188.9 g. The CMR waste drum shuffler has been tested and calibrated in passive mode in preparation for safeguards accountability measurements of waste drums containing material removed from CVs for the CVD project.

36 MATERIALS SCIENCE↗

Advanced High-Temperature Reactor Dynamic System Model Development: April 2012 Status

The Advanced High-Temperature Reactor (AHTR) is a large-output fluoride-salt-cooled high-temperature reactor (FHR). An early-phase preconceptual design of a 1500 MW(e) power plant was developed in 2011 [Refs. 1 and 2]. An updated version of this plant is shown as Fig. 1. FHRs feature low-pressure liquid fluoride salt cooling, coated-particle fuel, a high-temperature power cycle, and fully passive decay heat rejection. The AHTR is designed to be a “walk away” reactor that requires no action to prevent large off-site releases following even severe reactor accidents. This report describes the development of dynamic system models used to further the AHTR design toward that goal. These models predict system response during warmup, startup, normal operation, and limited off-normal operating conditions. Severe accidents that include a loss-of-fluid inventory are not currently modeled. The scope of the models is limited to the plant power system, including the reactor, the primary and intermediate heat transport systems, the power conversion system, and safety-related or auxiliary heat removal systems. The primary coolant system, the intermediate heat transport system and the reactor building structure surrounding them are shown in Fig. 2. These systems are modeled in the most detail because the passive interaction of the primary system with the surrounding structure and heat removal systems, and ultimately the environment, protects the reactor fuel and the vessel from damage during severe reactor transients. The reactor silo also plays an important role during system warmup. The dynamic system modeling tools predict system performance and response. The goal is to accurately predict temperatures and pressures within the primary, intermediate, and power conversion systems and to study the impacts of design changes on those responses. The models are design tools and are not intended to be used in reactor qualification. The important details to capture in the primary system relate to flows within the reactor vessel during severe events and the resulting temperature profiles (temperature and duration) for major components. Critical components include the fuel, reactor vessel, primary piping, and the primary-to-intermediate heat exchangers (P-IHXs). The major AHTR power system loops are shown in Fig. 3. The intermediate heat transfer system is a group of three pumped salt loops that transports the energy produced in the primary system to the power conversion system. Two dynamic system models are used to analyze the AHTR. A Matlab/Simulink-based model initiated in 2011 has been updated to reflect the evolving design parameters related to the heat flows associated with the reactor vessel. The Matlab model utilizes simplified flow assumptions within the vessel and incorporates an empirical representation of the Direct Reactor Auxiliary Cooling System (DRACS). A Dymola/Modelica model incorporates a more sophisticated representation of primary coolant flow and a physics-based representation of the three-loop DRACS thermal hydraulics. This model is not currently operating in a fully integrated mode. The Matlab model serves as a prototype and provides verification for the Dymola model, and its use will be phased out as the Dymola model nears completion. The heat exchangers in the system are sized using spreadsheet-based, steady-state calculations. The detail features of the heat exchangers are programmed into the dynamic models, and the overall dimensions are used to generate realistic plant designs. For the modeling cases where the emphasis is on understanding responses within the intermediate and primary systems, the power conversion system may be modeled as a simple boundary condition at the intermediate-to-power conversion system heat exchangers.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary of the Preliminary Optical ICHMI Design Study: A Preliminary Engineering Design Study for a Standpipe Viewport

This summary report examines an in-vessel optical access concept intended to support standoff optical instrumentation, control and human-machine interface (ICHMI) systems for future advanced small modular reactor (AdvSMR) applications. Optical-based measurement and sensing systems for AdvSMR applications have several key benefits over traditional instrumentation and control systems used to monitor reactor process parameters, such as temperature, flow rate, pressure, and coolant chemistry (Anheier et al. 2013). Direct and continuous visualization of the in-vessel components can be maintained using external cameras. Many optical sensing techniques can be performed remotely using open optical beam path configurations. Not only are in-vessel cables eliminated by these configurations, but also sensitive optical monitoring components (e.g., electronics, lasers, detectors, and cameras) can be placed outside the reactor vessel in the instrument vault, containment building, or other locations where temperatures and radiation levels are much lower. However, the extreme AdvSMR environment present challenges for optical access designs and optical materials. Optical access is not provided in any commercial nuclear power plant or featured in any reactor design, although successful implementation of optical access has been demonstrated in test reactors (Arkani and Gharib 2009). This report outlines the key engineering considerations for an AdvSMR optical access concept. Strict American Society of Mechanical Engineers (ASME) construction codes must be followed for any U.S. nuclear facility component (ASME 2013); however, the scope of this study is to evaluate the preliminary engineering issues for this concept, rather than developing a nuclear-qualified design. In addition, this study does not consider accident design requirements. In-vessel optical access using a standpipe viewport concept serves as a test case to explore the engineering challenges and performance requirements for sodium fast reactor (SFR) and high-temperature gas reactor (HTGR) AdvSMR applications. The expected environmental conditions for deployment are reviewed for both AdvSMR designs. Optical and mechanical materials that maximize component lifetime are evaluated for the standpipe viewport design under these conditions. Optical components and opto-mechanical designs that provide robust optical-to-metal seals and stress-free optical component mounting are identified, and then key performance specifications are developed for a sapphire optical viewport concept. Design strategies are examined that protect the internal optical surfaces from liquid-coolant condensation and impurity deposits. Finally, a conceptual standpipe viewport design that is suggestive of how this concept could be assembled using standard nuclear-qualified pipe components, is presented.

42 ENGINEERING↗

Corrosion impact of reductant on DWPF and downstream facilities

Glycolic acid is being evaluated as an alternate reductant in the preparation of high level waste for the Defense Waste Processing Facility (DWPF) at the Savannah River Site (SRS). During processing, the glycolic acid is not completely consumed and small quantities of the glycolate anion are carried forward to other high level waste (HLW) facilities. The impact of the glycolate anion on the corrosion of the materials of construction throughout the waste processing system has not been previously evaluated. A literature review had revealed that corrosion data in glycolate-bearing solution applicable to SRS systems were not available. Therefore, testing was recommended to evaluate the materials of construction of vessels, piping and components within DWPF and downstream facilities. The testing, conducted in non-radioactive simulants, consisted of both accelerated tests (electrochemical and hot-wall) with coupons in laboratory vessels and prototypical tests with coupons immersed in scale-up and mock-up test systems. Eight waste or process streams were identified in which the glycolate anion might impact the performance of the materials of construction. These streams were 70% glycolic acid (DWPF feed vessels and piping), SRAT/SME supernate (Chemical Processing Cell (CPC) vessels and piping), DWPF acidic recycle (DWPF condenser and recycle tanks and piping), basic concentrated recycle (HLW tanks, evaporators, and transfer lines), salt processing (ARP, MCU, and Saltstone tanks and piping), boric acid (MCU separators), and dilute waste (HLW evaporator condensate tanks and transfer line and ETF components). For each stream, high temperature limits and worst-case glycolate concentrations were identified for performing the recommended tests. Test solution chemistries were generally based on analytical results of actual waste samples taken from the various process facilities or of prototypical simulants produced in the laboratory. The materials of construction for most vessels, components and piping were not impacted with the presence of glycolic acid or the impact is not expected to affect the service life. However, the presence of the glycolate anion was found to affect corrosion susceptibility of some materials of construction in the DWPF and downstream facilities, especially at elevated temperatures. The following table summarizes the results of the electrochemical and hot wall testing and indicates expected performance in service with the glycolate anion present.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Optimization of Zero Emission Hydrogen Fuel Cell Ferry Design, With Comparisons to the SF-BREEZE

Zero emission hydrogen fuel cell technology has the potential to drastically reduce total “well-to-waves” maritime emissions. Through realistic design studies of five commercially-relevant passenger vessels, this study examines the most cost-effective entry points in the US fleet for deploying today’s available technology, and includes analysis of resulting well-to-waves emission profiles. The results show that per-passenger mile vessel energy use is directly correlated to increased emissions, capital costs, and operating costs. As a consequence, low speed, large capacity vessels offer a cost-effective starting place today. Increases in vessel efficiency through such measures as hull design and light-weighting can have large impacts in reducing cost and emissions of these systems. Overall this work showed all five vessel types to be feasible with today’s hydrogen fuel cell technology and presents more options to fleets that are committed to reducing maritime emissions in cost effective ways.

08 HYDROGEN↗