Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “validation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Clinical Validation of Atlas-Based Auto-Segmentation of Multiple Target Volumes and Normal Tissue (Swallowing/Mastication) Structures in the Head and Neck

Purpose: To validate and clinically evaluate autocontouring using atlas-based autosegmentation (ABAS) of computed tomography images. Methods and Materials: The data from 10 head-and-neck patients were selected as input for ABAS, and neck levels I-V and 20 organs at risk were manually contoured according to published guidelines. The total contouring times were recorded. Two different ABAS strategies, multiple and single subject, were evaluated, and the similarity of the autocontours with the atlas contours was assessed using Dice coefficients and the mean distances, using the leave-one-out method. For 12 clinically treated patients, 5 experienced observers edited the autosegmented contours. The editing times were recorded. The Dice coefficients and mean distances were calculated among the clinically used contours, autocontours, and edited autocontours. Finally, an expert panel scored all autocontours and the edited autocontours regarding their adequacy relative to the published atlas. Results: The time to autosegment all the structures using ABAS was 7 min/patient. No significant differences were observed in the autosegmentation accuracy for stage N0 and N+ patients. The multisubject atlas performed best, with a Dice coefficient and mean distance of 0.74 and 2 mm, 0.67 and 3 mm, 0.71 and 2 mm, 0.50 and 2 mm, and 0.78 and 2 mm for the salivary glands, neck levels, chewing muscles, swallowing muscles, and spinal cord-brainstem, respectively. The mean Dice coefficient and mean distance of the autocontours vs. the clinical contours was 0.8 and 2.4 mm for the neck levels and salivary glands, respectively. For the autocontours vs. the edited autocontours, the mean Dice coefficient and mean distance was 0.9 and 1.6 mm, respectively. The expert panel scored 100% of the autocontours as a 'minor deviation, editable' or better. The expert panel scored 88% of the edited contours as good compared with 83% of the clinical contours. The total editing time was 66 min. Conclusion: Multiple-subject ABAS of computed tomography images proved to be a useful novel tool in the rapid delineation of target and normal tissues. Although editing of the autocontours is inevitable, a substantial time reduction was achieved using editing, instead of manual contouring (180 vs. 66 min).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four-Week Neoadjuvant Intensity-Modulated Radiation Therapy With Concurrent Capecitabine and Oxaliplatin in Locally Advanced Rectal Cancer Patients: A Validation Phase II Trial

Purpose: To validate tolerance and pathological complete response rate (pCR) of a 4-week preoperative course of intensity-modulated radiation therapy (IMRT) with concurrent capecitabine and oxaliplatin (CAPOX) in patients with locally advanced rectal cancer. Methods and Materials: Patients with T3 to T4 and/or N+ rectal cancer received preoperative IMRT (47.5 Gy in 19 fractions) with concurrent capecitabine (825 mg/m{sup 2} b.i.d., Monday to Friday) and oxaliplatin (60 mg/m{sup 2} on Days 1, 8, and 15). Surgery was scheduled 4 to 6 weeks after the completion of chemoradiation. Primary end points were toxicity and pathological response rate. Local control (LC), disease-free survival (DFS), and overall survival (OS) were also analyzed. Results: A total of 100 patients were evaluated. Grade 1 to 2 proctitis was observed in 73 patients (73%). Grade 3 diarrhea occurred in 9% of the patients. Grade 3 proctitis in 18% of the first 50 patients led to reduction of the dose per fraction to 47.5 Gy in 20 treatments. The rate of Grade 3 proctitis decreased to 4% thereafter (odds ratio, 0.27). A total of 99 patients underwent surgery. A pCR was observed in 13% of the patients, major response (96-100% of histological response) in 48%, and pN downstaging in 78%. An R0 resection was performed in 97% of the patients. After a median follow-up of 55 months, the LC, DFS, and OS rates were 100%, 84%, and 87%, respectively. Conclusions: Preoperative CAPOX-IMRT therapy (47.5 Gy in 20 fractions) is feasible and safe, and produces major pathological responses in approximately 50% of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Indications for Pelvic Nodal Treatment in Prostate Cancer Should Change. Validation of the Roach Formula in a Large Extended Nodal Dissection Series

Purpose: Previous studies have criticized the predicting ability of the Roach formula in assessing the risk of lymph node invasion (LNI) in contemporary patients with prostate cancer (PCa) due to a significant overestimation of LNI rates. However, all those studies included patients treated with limited pelvic lymph node dissection (PLND), which is associated with high rates of false negative findings. We hypothesized that the Roach formula is still an accurate tool for LNI predictions if an extended PLND (ePLND) is performed. Methods and Materials: We included 3,115 consecutive patients treated with radical prostatectomy and ePLND between 2000 and 2010 at a single tertiary referral center. Extended PLND consisted of removal of obturator, external iliac, and hypogastric lymph nodes. We externally validated the Roach formula by using the area under the receiver operating characteristics curve and calibration plot method. Moreover, we tested the performance characteristics of different formula-generated cutoff values ranging from 1% to 20%. Results: The accuracy of the Roach formula was 80.3%. The calibration showed only a minor underestimation of the LNI risk in high-risk patients (6.7%). According to the Roach formula, the use of 15% cut off would have allowed 74.2% (2,311/3,115) of patients to avoid nodal irradiation, while up to 32.7% (111/336) of all patients with LNI would have been missed. When the cut off was lowered to 6%, nodal treatment would have been spared in 1,541 (49.5%) patients while missing 41 LNI patients. The sensitivity, specificity, and negative predictive values associated with the 6% cut off were 87.9%, 54%, and 97.3%, respectively. Conclusions: The Roach formula is still accurate and does not overestimate the rate of LNI in contemporary prostate cancer patients if they are treated with ePLND. However, the recommended cut off of 15% would miss approximately one-third of patients with LNI. Based on our results, the cut off should be lowered to 6%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

External Validation and Optimization of International Consensus Clinical Target Volumes for Adjuvant Radiation Therapy in Bladder Cancer

Purpose: International consensus (IC) clinical target volumes (CTVs) have been proposed to standardize radiation field design in the treatment of patients at high risk of locoregional failure (LRF) after radical cystectomy. The purpose of this study was to externally validate the IC CTVs in a cohort of postsurgical patients followed up for LRF and identify revisions that might improve the IC CTVs' performance. Methods and Materials: Among 334 patients with pT3 to pT4 bladder cancer treated with radical cystectomy, LRF developed in 58 (17%), of whom 52 had computed tomography scans available for review. Images with LRF were exported into a treatment planning system, and IC CTVs were contoured and evaluated for adequacy of coverage of each LRF with respect to both the patient and each of 6 pelvic subsites: common iliac (CI) region, obturator region (OR), external and internal iliac region, presacral region, cystectomy bed, or other pelvic site. Revisions to the IC contours were proposed based on the findings. Results: Of the 52 patients with documented LRF, 13 (25%) had LRFs that were outside of the IC CTV involving 17 pelvic subsites: 5 near the CI CTV, 5 near the OR CTV, 1 near the external and internal iliac region, and 6 near the cystectomy bed. The 5 CI failures were located superior to the CTV, and the 5 OR failures were located medial to the CTV. Increasing the superior boundary of the CI to a vessel-based definition of the aortic bifurcation, as well as increasing the medial extension of the OR by an additional 9 mm, decreased the number of patients with LRF outside of the IC CTV to 7 (13%). Conclusions: Modified IC CTVs inclusive of a slight adjustment superiorly for the CI region and medially for the OR may reduce the risk of pelvic failure in patients treated with adjuvant radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MR-OPERA: A Multicenter/Multivendor Validation of Magnetic Resonance Imaging–Only Prostate Treatment Planning Using Synthetic Computed Tomography Images

Purpose: To validate the dosimetric accuracy and clinical robustness of a commercially available software for magnetic resonance (MR) to synthetic computed tomography (sCT) conversion, in an MR imaging–only workflow for 170 prostate cancer patients. Methods and Materials: The 4 participating centers had MriPlanner (Spectronic Medical), an atlas-based sCT generation software, installed as a cloud-based service. A T2-weighted MR sequence, covering the body contour, was added to the clinical protocol. The MR images were sent from the MR scanner workstation to the MriPlanner platform. The sCT was automatically returned to the treatment planning system. Four MR scanners and 2 magnetic field strengths were included in the study. For each patient, a CT-treatment plan was created and approved according to clinical practice. The sCT was rigidly registered to the CT, and the clinical treatment plan was recalculated on the sCT. The dose distributions from the CT plan and the sCT plan were compared according to a set of dose-volume histogram parameters and gamma evaluation. Treatment techniques included volumetric modulated arc therapy, intensity modulated radiation therapy, and conventional treatment using 2 treatment planning systems and different dose calculation algorithms. Results: The overall (multicenter/multivendor) mean dose differences between sCT and CT dose distributions were below 0.3% for all evaluated organs and targets. Gamma evaluation showed a mean pass rate of 99.12% (0.63%, 1 SD) in the complete body volume and 99.97% (0.13%, 1 SD) in the planning target volume using a 2%/2-mm global gamma criteria. Conclusions: Results of the study show that the sCT conversion method can be used clinically, with minimal differences between sCT and CT dose distributions for target and relevant organs at risk. The small differences seen are consistent between centers, indicating that an MR imaging–only workflow using MriPlanner is robust for a variety of field strengths, vendors, and treatment techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for bounding high-order finite element functions: Applications to mesh validity and bounds-preserving limiters

We introduce a novel method for bounding high-order multi-dimensional polynomials in finite element approximations. The method involves precomputing optimal piecewise-linear bounding boxes for polynomial basis functions, which can then be used to locally bound any combination of these basis functions. This approach can be applied to any element/basis type at any approximation order, can provide local (i.e., subcell) extremum bounds to a desired level of accuracy, and can be evaluated efficiently on-the-fly in simulations. Furthermore, we show that this approach generally yields more accurate bounds in comparison to traditional methods based on convex hull properties (e.g., Bernstein polynomials). Furthermore, the efficacy of this technique is shown in applications such as mesh validity checks and optimization for high-order curved meshes, where positivity of the element Jacobian determinant can be ensured throughout the entire element, and continuously bounds-preserving limiters for hyperbolic systems, which can enforce maximum principle bounds across the entire solution polynomial.

Bounding box↗

Thermal-shock experiments for separate-effects validation of UO 2 fuel fracture models

Because of the important role that fracture plays in the behavior of ceramic UO2 fuel in a nuclear reactor environment, fracture models are a major component of fuel performance codes. As with any aspect of fuel performance, it is crucial to validate these fracture models against experimental data; however, obtaining well-controlled data for conditions representative of a reactor environment is difficult. Quenching is proposed here as a relatively simple approach for using a laboratory environment to achieve conditions that approximate those of a reactor environment. In this paper, an experimental apparatus containing a single instrumented fuel pellet in a sealed section of copper tubing is developed. It is then applied to a series of seven experiments in which the apparatus is first heated to a high temperature (580-680°C) by immersion in a molten salt bath, then quenched in a cold bath (-10-4 °C). Development of these experiments was guided by numerical simulations, and post-test simulations were performed to aid in understanding the experimental behavior and assessing the accuracy of the predictions of fracture initiation and propagation. In addition, similar experiments were performed on solid copper rods to provide temperature-dependent heat transfer coefficients for use in simulations of these experiments. Here, this study demonstrates that quenching is a viable approach for generating thermal gradients representative of those in prototypical light-water reactor conditions at powers of about 5–10 kW/m. Fracture is expected to begin at these power levels, and moderate amounts of radial and axial cracking was observed in these quenching tests.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Scalable phononic metamaterials: Tunable bandgap design and multi-scale experimental validation

Phononic metamaterials offer unprecedented control over wave propagation, making them essential for applications such as vibration isolation, waveguiding, and acoustic filtering. However, achieving scalable and precisely tunable bandgap properties across different length scales remains challenging. This study presents a user-friendly design framework for phononic metamaterials, enabling ultra-wide bandgap tunability (B/ω c ratios up to 172 %) across multiple frequency ranges and scales. Using finite element simulations of a Yablonovite-inspired unit cell, we establish a comprehensive parametric design space that illustrates how geometric parameters, such as sphere size and beam diameter, controls bandgap width and frequency. The scalability and robustness of the framework are validated through experimental testing on additively manufactured structures at both macro (10 mm) and micro (80 µm) scales, fabricated using Stereolithography and Two-Photon Polymerization. Transmission loss measurements, conducted with piezoelectric transducers and laser vibrometry, closely match simulations in the kHz and MHz frequency ranges, confirming the reliability and consistency of the bandgap behavior across scales. This work bridges theory and experiments at multiple scales, offering a practical methodology for the rapid design of phononic metamaterials and expanding their potential for diverse applications across a broad range of frequencies.

36 MATERIALS SCIENCE↗

Thermodynamic modeling and experimental validation of the Fe-Al-Ni-Cr-Mo alloy system

NiAl-type precipitate-strengthened ferritic steels have been known as potential materials for the steam turbine applications. In this study, thermodynamic descriptions of the B2-NiAl type nano-scaled precipitates and body-centered-cubic (BCC) Fe matrix phase for four alloys based on the Fe-Al-Ni-Cr-Mo system were developed as a function of the alloy composition at the aging temperature. The calculated phase structure, composition, and volume fraction were validated by the experimental investigations using synchrotron X-ray diffraction and atom probe tomography. With the ability to accurately predict the key microstructural features related to the mechanical properties in a given alloy system, the established thermodynamic model in the current study may significantly accelerate the alloy design process of the NiAl-strengthened ferritic steels.

36 MATERIALS SCIENCE↗

Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors

The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos (t) with a constant respiration period of 4.0 sec along the longitudinal axis of the CT couch. The extent of motion (A{sub 1}) was set in the range of 0.0-12.0 mm at 3.0-mm intervals. Treatment planning with the heterogeneity-corrected dose-volume prescription was designed on RACT images. A new commercially available Monte Carlo algorithm of well-commissioned 6-MV photon beam was used for dose calculation. Dosimetric effects of intrafractional tumor motion were then investigated experimentally under the same conditions as 4D CT simulation using the dynamic anthropomorphic thorax phantom, films, and an ionization chamber. The passing rate of {gamma} index was 98.18%, with the criteria of 3 mm/3%. The dose error between the planned and the measured isocenter dose in moving condition was within {+-} 0.7%. From the dose area histograms on the film, the mean {+-} standard deviation of the dose covering 100% of the cross section of the target was 102.32 {+-} 1.20% (range, 100.59-103.49%). By contrast, the irradiated areas receiving more than 95% dose for A{sub 1} = 12 mm were 1.46 and 1.33 times larger than those for A{sub 1} = 0 mm in the coronal and sagittal planes, respectively. This phantom study demonstrated that the cross section of the target received 100% dose under moving conditions in both the coronal and sagittal planes, suggesting that the heterogeneity-corrected dose-volume prescription on RACT images is acceptable in SBRT for moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Validation of the two-region Rossi-alpha model for reflected assemblies

Nuclear criticality safety, nonproliferation and safeguards, emergency response, and stockpile stewardship utilize estimates of the k eff multiplication factor. The value of k eff cannot be directly measured, but it can be inferred from the prompt neutron period. One modality of measuring the prompt neutron period is the Rossi-alpha method, which is predicated on fitting a histogram of detection time differences due to the nonrandom temporal distribution of same-fission-chain neutrons. Recent works have developed the motivation and theory to expand traditional one-region point kinetic models resulting in one-exponential histogram fits to two-region models that result in two-exponential fits. This paper validates the new two-region model using organic scintillator measurements of copper-reflected weapons-grade plutonium (0:83 ≤ k eff ≤ 0:94) and high-density- polyethylene-reflected highly enriched uranium (0:73 ≤ k eff ≤ 0:95). Furthermore, the results show that more thermal systems have shorter prompt neutron periods in the core region due to increased induced-fission probabilities for moderated neutrons. Here, a new parameter introduced by the two- region model is also shown to be correlated to the amount of reflection, and may be used to infer assembly properties such as type and amount of reflector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Jacobian-free Newton–Krylov method in implicitly solving two-fluid six-equation two-phase flow problems: Implementation, validation and benchmark

This work represents a first-of-its-kind successful application to employ advanced numerical methods in solving realistic two-phase flow problems with two-fluid six-equation two-phase flow model. These advanced numerical methods include high-resolution spatial discretization scheme with staggered grids (high-order) fully implicit time integration schemes, and Jacobian-free Newton–Krylov (JFNK) method as the nonlinear solver. The computer code developed in this work has been extensively validated with existing experimental flow boiling data in vertical pipes and rod bundles, which cover wide ranges of experimental conditions, such as pressure, inlet mass flux, wall heat flux and exit void fraction. Additional code-to-code benchmark with the RELAP5-3D code further verifies the correct code implementation. The combined methods employed in this work exhibit strong robustness in solving two-phase flow problems even when phase appearance (boiling) and realistic discrete flow regimes are considered. Transitional flow regimes used in existing system analysis codes, normally introduced to overcome numerical difficulty, were completely removed in this work. As a result, this in turn provides the possibility to utilize more sophisticated flow regime maps in the future to further improve simulation accuracy.

42 ENGINEERING↗

Validation of a 2.5D CFD model for cylindrical gas–solids fluidized beds

The 2.5D model recently proposed by Li et al. (Li, T., Benyahia, S., Dietiker, J., Musser, J., and Sun, X., 2015. A 2.5D computational method to simulate cylindrical fluidized beds. Chemical Engineering Science. 123, 236-246.) was validated for two cylindrical gas-solids bubbling fluidized bed systems. Different types of particles tested under various flow conditions were simulated using the traditional 2D model and the 2.5D model. Detailed comparison against the experimental measurements on solid concentration and velocity were conducted. Comparing to the traditional Cartesian 2D flow simulation, the 2.5D model yielded better agreement with the experimental data especially for the solid velocity prediction in the column wall region.

Numerical simulation↗

A comparison of model validation approaches for echo state networks using climate model replicates

As global temperatures continue to rise, climate mitigation strategies such as stratospheric aerosol injections (SAI) are increasingly discussed, but the downstream effects of these strategies are not well understood. As such, there is interest in developing statistical methods to quantify the evolution of climate variable relationships during the time period surrounding an SAI. Feature importance applied to echo state network (ESN) models has been proposed as a way to understand the effects of SAI using a data-driven model. This approach depends on the ESN fitting the data well. If not, the feature importance may place importance on features that are not representative of the underlying relationships. Typically, time series prediction models such as ESNs are assessed using out-of-sample performance metrics that divide the times series into separate training and testing sets. However, this model assessment approach is geared towards forecasting applications and not scenarios such as the motivating SAI example where the objective is using a data driven model to capture variable relationships. Here, in this paper, we demonstrate a novel use of climate model replicates to investigate the applicability of the commonly used repeated hold-out model assessment approach for the SAI application. Simulations of an SAI are generated using a simplified climate model, and different initialization conditions are used to provide independent training and testing sets containing the same SAI event. The climate model replicates enable out-of-sample measures of model performance, which are compared to the single time series hold-out validation approach. For our case study, it is found that the repeated hold-out sample performance is comparable, but conservative, to the replicate out-of-sample performance when the training set contains enough time after the aerosol injection.

54 ENVIRONMENTAL SCIENCES↗

The validation of an invitro colonic motility assay as a biomarker for gastrointestinal adverse drug reactions

Motility-related gastrointestinal adverse drug reactions (GADRs), such as constipation and diarrhea, are some of the most frequently reported adverse events associated with the clinical development of new chemical entities, and for marketed drugs. However, biomarkers capable of detecting such GADRs are lacking. Here, we describe an in vitro assay developed to detect and quantify changes in intestinal motility as a surrogate biomarker for constipation/diarrhea-type GADRs. In vitro recordings of intraluminal pressure were used to monitor the presence of colonic peristaltic motor complexes (CPMCs) in mouse colonic segments. CPMC frequency, contractile and total mechanical activity were assessed. To validate the assay, two experimental protocols were conducted. Initially, five drugs with known gastrointestinal effects were tested to determine optimal parameters describing excitation and inhibition as markers for disturbances in colonic motility. This was followed by a 'blinded' evaluation of nine drugs associated with or without clinically identified constipation/diarrhea-type GADRs. Concentration-response relationships were determined for these drugs and the effects were compared with their maximal free therapeutic plasma concentration in humans. The assay detected stimulatory and inhibitory responses, likely correlating to the occurrence of diarrhea or constipation. Concentration-related effects were identified and potential mechanisms of action were inferred for several drugs. Based on the results from the fourteen drugs assessed, the sensitivity of the assay was calculated at 90%, with a specificity of 75% and predictive capacity of 86%. These results support the potential use of this assay in screening for motility-related GADRs during early discovery phase, safety pharmacology assessment.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Model calibration and validation for OFMSW and sewage sludge co-digestion reactors

Highlights: > Disintegration is the limiting step of the anaerobic co-digestion process. > Disintegration kinetic constant does not depend on the waste particle size. > Disintegration kinetic constant depends only on the waste nature and composition. > The model calibration can be performed on organic waste of any particle size. - Abstract: A mathematical model has recently been proposed by the authors to simulate the biochemical processes that prevail in a co-digestion reactor fed with sewage sludge and the organic fraction of municipal solid waste. This model is based on the Anaerobic Digestion Model no. 1 of the International Water Association, which has been extended to include the co-digestion processes, using surface-based kinetics to model the organic waste disintegration and conversion to carbohydrates, proteins and lipids. When organic waste solids are present in the reactor influent, the disintegration process is the rate-limiting step of the overall co-digestion process. The main advantage of the proposed modeling approach is that the kinetic constant of such a process does not depend on the waste particle size distribution (PSD) and rather depends only on the nature and composition of the waste particles. The model calibration aimed to assess the kinetic constant of the disintegration process can therefore be conducted using organic waste samples of any PSD, and the resulting value will be suitable for all the organic wastes of the same nature as the investigated samples, independently of their PSD. This assumption was proven in this study by biomethane potential experiments that were conducted on organic waste samples with different particle sizes. The results of these experiments were used to calibrate and validate the mathematical model, resulting in a good agreement between the simulated and observed data for any investigated particle size of the solid waste. This study confirms the strength of the proposed model and calibration procedure, which can thus be used to assess the treatment efficiency and predict the methane production of full-scale digesters.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Validation of Sandwich ELISA Microarrays with Minimal Assay Interference

Sandwich enzyme-linked immunosorbent assay (ELISA) microarrays are emerging as a strong candidate platform for multiplex biomarker analysis because of the ELISA’s ability to quantitatively measure rare proteins in complex biological fluids. Advantages of this platform are high-throughput potential, assay sensitivity and stringency, and the similarity to the standard ELISA test, which facilitates assay transfer from a research setting to a clinical laboratory. However, a major concern with the multiplexing of ELISAs is maintaining high assay specificity. In this study, we systematically determine the amount of assay interference and noise contributed by individual components of the multiplexed 24-assay system. We find that non-specific reagent cross-reactivity problems are relatively rare. We did identify the presence of contaminant antigens in a “purified antigen”. We tested the validated ELISA microarray chip using paired serum samples that had been collected from four women at a 6-month interval. This analysis demonstrated that protein levels typically vary much more between individuals then within an individual over time, a result which suggests that longitudinal studies may be useful in controlling for biomarker variability across a population. Overall, this research demonstrates the importance of a stringent screening protocol and the value of optimizing the antibody and antigen concentrations when designing chips for ELISA microarrays.

59 BASIC BIOLOGICAL SCIENCES↗