Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Leachate Treatment for Radioactive Waste Containment Mound: Pilot Test and Design - 19098

Canadian Nuclear Laboratories plans to construct an engineered containment mound (ECM) at its Chalk River Laboratories site in Ontario for safe management of radioactive and mixed waste at the facility. The ECM is designed for containment of 1,000,000 cubic meters of waste, and will be operated over a period of 50 years. Contact storm water, leachate, and other wastewater will be generated during operation of the ECM, and must be treated prior to discharge to the environment. The wastewater is projected to contain low concentrations of radionuclides and metals, as well as other cations and anions, and low concentrations of organic chemicals. Through comparison with surface water discharge criteria, radionuclides cesium-137 and strontium-90, and metals including aluminum, barium, copper, iron, lead, and manganese were projected to be present in the wastewater at concentrations that may exceed surface water discharge criteria, and were therefore targeted for treatment. Several technologies, including chemical precipitation, membrane filtration, ion exchange, and reverse osmosis were reviewed and tested on a laboratory scale using simulated wastewater prepared to replicate the concentrations of both target and non-target constituents. Based upon the results of the laboratory-scale tests, a six-week pilot test was conducted to simulate the performance of the technologies under continuous-flow conditions and determine full-scale design criteria. This paper describes the methodology and results of the six-week pilot test, and how the test results were used to inform the full-scale wastewater treatment system design. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Predictions of the AGR-3/4 Experiment With Time-Varying Gas Gaps

In this paper, a thermal analysis was performed for the Advanced Gas Reactor test experiment (AGR-3/4) with time-varying gas gaps. The experiment was irradiated at the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL). Several fuel irradiation experiments are planned for the AGR Fuel Development and Qualification Program that supports the development of the Very-High-Temperature Gas-Cooled Reactor (VHTR) under the Next-Generation Nuclear Plant (NGNP) project. AGR-3/4 combines two tests in a series of planned AGR experiments to test tristructural-isotropic (TRISO)-coated, low-enriched uranium oxy-carbide fuel. Forty-eight TRISO-fueled compacts were inserted into 12 separate capsules for the experiment (four compacts per capsule). The purpose of this analysis was to calculate the temperatures of each compact and graphite layer to obtain daily average temperatures using time (fast neutron fluence)-varying gas gaps and to compare with experimentally measured thermocouple data. A finite-element heat transfer model was created for each capsule using the commercial code ABAQUS. Finally, model results are compared to thermocouple data taken during the experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Pressurized Slot Testing to Determine Thermo-Mechanical Properties of Lithophysal Tuff at Yucca Mountain Nevada.

The study described in this report involves heated and unheated pressurized slot testing to determine thermo-mechanical properties of the Tptpll (Tertiary, Paintbrush, Topopah Spring Tuff Formation, crystal poor, lower lithophysal) and Tptpul (upper lithophysal) lithostratigraphic units at Yucca Mountain, Nevada. A large volume fraction of the proposed repository at Yucca Mountain may reside in the Tptpll lithostratigraphic unit. This unit is characterized by voids, or lithophysae, which range in size from centimeters to meters, making a field program an effective method of measuring bulk thermal-mechanical rock properties (thermal expansion, rock mass modulus, compressive strength, time-dependent deformation) over a range of temperature and rock conditions. The field tests outlined in this report provide data for the determination of thermo-mechanical properties of this unit. Rock-mass response data collected during this field test will reduce the uncertainty in key thermal-mechanical modeling parameters (rock-mass modulus, strength and thermal expansion) for the Tptpll lithostratigraphic unit, and provide a basis for understanding thermal-mechanical behavior of this unit. The measurements will be used to evaluate numerical models of the thermal-mechanical response of the repository. These numerical models are then used to predict pre- and post-closure repository response. ACKNOWLEDGEMENTS The authors would like to thank David Bronowski, Ronnie Taylor, Ray E. Finley, Cliff Howard, Michael Schuhen (all SNL) and Fred Homuth (LANL) for their work in the planning and implementation of the tests described in this report. This is a reprint of SAND2004-2703, which was originally printed in July 2004. At that time, it was printed for a restricted audience. It has now been approved for unlimited release.

36 MATERIALS SCIENCE↗

SU-E-T-27: A Tool for Routine Quality Assurance of Radiotherapy Dose Calculation Software

Purpose: Dose calculation software is thoroughly evaluated when it is commissioned; however, evaluation of periodic software updates is typically limited in scope due to staffing constraints and the need to quickly return the treatment planning system to clinical service. We developed a tool for quickly and comprehensively testing and documenting dose calculation software against measured data. Methods: A tool was developed using MatLab (The MathWorks, Natick, MA) for evaluation of dose calculation algorithms against measured data. Inputs to the tool are measured data, reference DICOM RT PLAN files describing the measurements, and dose calculations in DICOM format. The tool consists of a collection of extensible modules that can perform analysis of point dose, depth dose curves, and profiles using dose difference, distance-to-agreement, and the gamma-index. Each module generates a report subsection that is incorporated into a master template, which is converted to final form in portable document format (PDF). Results: After each change to the treatment planning system, a report can be generated in approximately 90 minutes. The tool has been in use for more than 5 years, spanning 5 versions of the eMC and 4 versions of the AAA. We have detected changes to the algorithms that affected clinical practice once during this period. Conclusion: Our tool provides an efficient method for quality assurance of dose calculation software, providing a complete set of tests for an update. Future work includes the addition of plan level tests, allowing incorporation of, for example, the TG-119 test suite for IMRT, and integration with the treatment planning system via an application programming interface. Integration with the planning system will permit fully-automated testing and reporting at scheduled intervals.

07 ISOTOPE AND RADIATION SOURCES↗

Feasibility of an image planning system for kilovoltage image-guided radiation therapy

Purpose: Image guidance has become a standard of care for many treatment scenarios in radiation therapy. This is most typically accomplished by use of kV x-ray devices mounted onto the linear accelerator (Linac) gantry that yield planar, fluoroscopic, and cone-beam computed tomography (CBCT) images. Image acquisition parameters are chosen via preset techniques that rely on broad categorizations in patient anatomy and imaging goal. However, the optimal imaging technique results in detectability of the features of interest while exposing the patient to minimum dose. Herein, the authors present an investigation into the feasibility of developing an image planning system (IPS) for radiotherapy.Methods: In this first phase, the authors focused on developing an algorithm to predict tissue contrast produced by a common radiotherapy planar imaging chain. Input parameters include a CT dataset and simulated planar imaging technique settings that include kV and mAs. Energy-specific attenuation through each voxel of the CT dataset was calculated in the algorithm to derive a net transmitted intensity. The response of the flat panel detector was integrated into the image simulation algorithm. Verification was conducted by comparing simulated and measured images using four phantoms. Comparisons were made in both high and low contrast settings, as well as changes in the geometric appearance due to image saturation. Results: The authors studied a lung nodule test object to assess the planning system's ability to predict object contrast and detectability. Verification demonstrated that the slope of the pixel intensities is similar, the presence of the nodule is evident, and image saturation at high mAs values is evident in both images. The appearance of the lung nodule is a function of the image detector saturation. The authors assessed the dimensions of the lung nodule in measured and simulated images. Good quantitative agreement affirmed the algorithm's predictive capabilities. The invariance of contrast with kVp and mAs prior to saturation was predicted, as well as the gradual loss of object detectability as saturation was approached. Small changes in soft tissue density were studied using a mammography step wedge phantom. Data were acquired at beam qualities of 80 and 120 kVp and over exposure values ranging from 0.04 to 500 mAs. The data showed good agreement in terms of the absolute value of pixel intensities predicted, as well as small variations across the step wedge pattern. The saturation pixel intensity was consistent between the two beam qualities studied. Boney tissue contrast was assessed using two abdominal phantoms. Measured and calculated values agree in terms of predicting the mAs value at which detector saturation, and subsequent loss of contrast occurs. The lack of variation in contrast over mAs values lower than 10 suggests that there is wide latitude for minimizing patient dose. Conclusions: The authors developed and tested an algorithm that can be used to assist in kV imaging technique selection during localization for radiotherapy. Phantom testing demonstrated the algorithm's predictive accuracy for both low and high contrast imaging scenarios. Detector saturation with subsequent loss of imaging detail, both in terms of object size and contrast were accurately predicted by the algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-514: Evaluation of the Accuracy of Free-Breathing and Deep Inspiration Breath-Hold Gated Beam Delivery Using An Elekta Linac

Purpose: In this study, we evaluated the performance of an Elekta linac in the delivery of gated radiotherapy. We examined whether the use of either a short gating window or a long beam hold impacts the accuracy of the delivery Methods: The performance of an Elekta linac in the delivery of gated radiotherapy was assessed using a 20cmX 20cm open field with the radiation delivered using a range of beam-on and beam-off time periods. Two SBRT plans were used to examine the accuracy of gated beam delivery for clinical treatment plans. For the SBRT cases, tests were performed for both free-breathing based gating and for gated delivery with a simulated breath-hold. A MatriXX 2D ion chamber array was used for data collection, and the gating accuracy was evaluated using gamma score. Results: For the 20cmX20cm open field, the gated beam delivery agreed closely with the non-gated delivery results. Discrepancies in the agreement, however, began to appear with a 5-to-1 ratio of the beam-off to beam-on. For these tight gating windows, each beam-on segment delivered a small number of monitor units. This finding was confirmed with dose distribution analysis from the delivery of the two VMAT plans where the gamma score(±1%,2%/1mm) showed passing rates in the range of 95% to 100% for gating windows of 25%, 38%, 50%, 63%, 75%, and 83%. Using a simulated sinusoidal breathing signal with a 4 second period, the gamma score of freebreathing gating and breath-hold gating deliveries were measured in the range of 95.7% to 100%. Conclusion: The results demonstrate that Elekta linacs can be used to accurately deliver respiratory gated treatments for both free-breathing and breath-hold patients. The accuracy of beams delivered in a gated delivery mode at low small MU proved higher than similar deliveries performed in a non-gated (manually interrupted) fashion.

60 APPLIED LIFE SCIENCES↗

Preliminary Project Execution Plan for the TREAT LEU Fuel Conversion Project

This project execution plan for the Transient Reactor Test (TREAT) facility Low Enriched Uranium (LEU) Fuel Conversion Project informs the reader of a high-level path forward for conversion of TREAT facilities at Idaho National Laboratory and provides guidance for INL personnel regarding the TREAT LEU Fuel Conversion Project. This project is part of the National Nuclear Security Administration’s Global Threat Reduction Initiative Reactor Conversion Program.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-T-194: Analyzing the Effect of Range Shifter Air Gap On TPS Dose Modeling Accuracy in Superficial PBS Proton Therapy

Purpose: Treatment planning systems (TPS) may not accurately model superficial dose distributions of range shifted proton pencil beam scanning (PBS) treatments. Numerous patient-specific QA tests performed on superficially treated PBS plans have shown a consistent overestimate of dose by the TPS. This study quantifies variations between TPS planned dose and measured dose as a function of range shifter air gap and treatment depths up to 5 cm. Methods: PBS treatment plans were created in the TPS to uniformly irradiate a volume of solid water. One plan was created for each range shifter position analyzed, and all plans utilized identical dose optimization parameters. Each optimized plan was analyzed in the TPS to determine the planned dose at varying depths. A PBS proton therapy system with a 3.5 cm lucite range shifter delivered the treatment plans, and a parallel plate chamber embedded in RW3 solid water measured dose at shallow depths for each air gap. Differences between measured and planned doses were plotted and analyzed. Results: The data show that the TPS more accurately models superficial dose as the air gap between the range shifter and patient surface decreases. Air gaps less than 10 cm have an average dose difference of only 1.6%, whereas air gaps between 10 and 20 cm differ by 3.0% and gaps greater than 20 cm differ by 4.4%. Conclusion: This study has shown that the TPS is unable to accurately model superficial dose with a large range shifter air gap. Dose differences greater than 3% will likely cause QA failure, as many institutions analyze patient QA with a 3%/3mm gamma analysis. For superficial PBS therapy, range shifter positions should be chosen to keep the air gap less then 10 cm when patient setup and gantry geometry allow.

60 APPLIED LIFE SCIENCES↗

Lawrence Livermore National Laboratory Experimental Test Site 300: Energetic Materials Development Enclave (EMDEC) Soil Sampling and Analysis Plan Addendum 1 (April 2023)

The purpose of this addendum is to amend and update the Energetic Materials Development Enclave [project] Soil Sampling and Analysis Plan (SAP) dated June 2022 (LLNL-AM-22- 21678). In July 2022, portions of the SAP were completed. Since then, the project scope and limits have been redefined to include potential additional buildings. The exact locations of the additional buildings have not been determined, but the Project Management Office (PMO) would like to investigate at this time additional areas adjacent to the investigation area subject to the June 2022 SAP. The information contained in this addendum supersedes the June 2022 SAP. However, this addendum only addresses elements of the June 2022 SAP that were modified. Elements of the June 2022 SAP that have not been modified are relevant and will remain in effect.

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Investigation plan for Corrective Action Unit 546: Injection Well and Surface Releases, Nevada Test Site, Nevada, Revision 0

Corrective Action Unit (CAU) 546 is located in Areas 6 and 9 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 546 is comprised of two Corrective Action Sites (CASs) listed below: •06-23-02, U-6a/Russet Testing Area •09-20-01, Injection Well These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation (CAI) before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on November 8, 2007, by representatives of the Nevada Division of Environmental Protection and U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process has been used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 546.

Wickline, Alfred↗

Corrective Action Investigation Plan for Corrective Action Unit 372: Area 20 Cabriolet/Palanquin Unit Craters Nevada Test Site, Nevada, Revision 0

Corrective Action Unit (CAU) 372 is located in Areas 18 and 20 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 372 is comprised of the four corrective action sites (CASs) listed below: • 18-45-02, Little Feller I Surface Crater • 18-45-03, Little Feller II Surface Crater • 20-23-01, U-20k Contamination Area • 20-45-01, U-20L Crater (Cabriolet) These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives. Additional information will be obtained by conducting a corrective action investigation (CAI) before evaluating corrective action alternatives and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable corrective action alternatives that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on February 10, 2009, by representatives of the Nevada Division of Environmental Protection; U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office; Stoller-Navarro Joint Venture; Desert Research Institute, and National Security Technologies, LLC. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 372.

54 ENVIRONMENTAL SCIENCES↗

Corrective Action Investigation Plan for Corrective Action Unit 374: Area 20 Schooner Unit Crater Nevada Test Site, Nevada, Revision 0

Corrective Action Unit 374 is located in Areas 18 and 20 of the Nevada Test Site, which is approximately 65 miles northwest of Las Vegas, Nevada. Corrective Action Unit 374 comprises the five corrective action sites (CASs) listed below: • 18-22-05, Drum • 18-22-06, Drums (20) • 18-22-08, Drum • 18-23-01, Danny Boy Contamination Area • 20-45-03, U-20u Crater (Schooner) These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives (CAAs). Additional information will be obtained by conducting a corrective action investigation before evaluating CAAs and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable CAAs that will be presented in the Corrective Action Decision Document. The sites will be investigated based on the data quality objectives (DQOs) developed on October 20, 2009, by representatives of the Nevada Division of Environmental Protection and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 374.

54 ENVIRONMENTAL SCIENCES↗

Design and Testing of Prototypic Elements Containing Monolithic Fuel

The US fuel development team has performed numerous irradiation tests on small to medium sized specimens containing low enriched uranium fuel designs. The team is now focused on qualification and demonstration of the uranium-molybdenum Base Monolithic Design and has entered the next generation of testing with the design and irradiation of prototypic elements which contain this fuel. The designs of fuel elements containing monolithic fuel, such as AFIP-7 (which is currently under irradiation) and RERTR-FE (which is currently under fabrication), are appropriate progressions relative to the technology life cycle. The culmination of this testing program will occur with the design, fabrication, and irradiation of demonstration products to include the base fuel demonstration and design demonstration experiments. Future plans show that design, fabrication, and testing activities will apply the rigor needed for a demonstration campaign.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Planned High-brightness Channeling Radiation Experiment at Fermilab's Advanced Superconducting Test Accelerator

In this contribution we describe the technical details and experimental setup of our study aimed at producing high-brightness channeling radiation (CR) at Fermilab’s new user facility the Advanced Superconducting Test Accelerator (ASTA). In the ASTA photoinjector area electrons are accelerated up to 40-MeV and focused to a sub-micron spot on a ~40 micron thick carbon diamond, the electrons channel through the crystal and emit CR up to 80-KeV. Our study utilizes ASTA’s long pulse train capabilities and ability to preserve ultra-low emittance, to produce the desired high average brightness.

43 PARTICLE ACCELERATORS↗

Combined TREAT-LOC and SATS LOCA Experiment Plan: Integral LOCA Experiments on High-Burnup Fuels

The Transient Reactor Test Facility (TREAT) loss-of-coolant (LOC) and high-burnup (HBu) experiment series, along with the Severe Accident Test Station (SATS) HBu experiment series, are integral LOC accident (LOCA) experiments planned under the DOE AFC program, which aim to support burnup extension needs by addressing identified R&D priorities in order to achieve an improved understanding of fuel fragmentation, relocation, and dispersal (FFRD) of HBu fuel during LOCA events. The data produced under this plan will be used to further validate and confirm existing models and inform future R&D and model development. The experimental program has been specifically designed to address knowledge gaps and opportunities identified through a detailed review of existing public knowledge on LOCA FFRD. The test program employs a unique combination of in- and out-of-pile experimental approaches and state-of-the-art facilities to provide a clear connection to the existing integral and semi-integral LOCA experiment database. The primary goal of the program is to investigate the impact of prototypic HBu fuel/cladding thermomechanical behaviors under postulated LWR LOCA conditions that have not yet been fully studied. These conditions correspond with prototypic decay-energy heatup (DEH) and stored-energy heatup (SEH) conditions. Importantly, TREAT’s unique capability will enable the first evaluation of the impact of SEH conditions on HBu fuels. The test program will emphasize the development of an improved mechanistic understanding of key experimental phenomena through independent experimental systems, development of a database to support fuel performance modeling tools and employing world-leading advanced materials characterization and in-situ diagnostics to evaluate FFRD. The results of the program will provide novel data to support modeling development and validation and will represent a significant advancement in evaluating prototypic conditions, as well as to inform the technical basis for LOCA-induced FFRD.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Effect of Radiotherapy Techniques (IMRT vs. 3D-CRT) on Outcome in Patients With Intermediate-Risk Rhabdomyosarcoma Enrolled in COG D9803-A Report From the Children's Oncology Group

Purpose: To compare the dosimetric parameters of intensity-modulated radiotherapy (IMRT) and three-dimensional conformal radiotherapy (3D-CRT) in patients with intermediate-risk rhabdomyosarcoma and to analyze their effect on locoregional control and failure-free survival (FFS). Methods and Materials: The study population consisted of 375 patients enrolled in the Children's Oncology Group protocol D9803 study, receiving IMRT or 3D-CRT. Dosimetric data were collected from 179 patients with an available composite plan. The chi-square test or Fisher's exact test was used to compare the patient characteristics and radiotherapy parameters between the two groups. The interval-to-event outcomes were estimated using the Kaplan-Meier method and compared using log-rank tests. Cox proportional hazards regression analysis was used to examine the effect of the treatment technique on FFS after adjusting for primary site and risk group. Results: The median follow-up time was 5.7 and 4.2 years for patients receiving 3D-CRT and IMRT, respectively. No differences in the 5-year failure of locoregional control (18% vs. 15%) or FFS (72% vs. 76%) rates were noted between the two groups. Multivariate analysis revealed no association between the two techniques and FFS. Patients with primary tumors in parameningeal sites were more likely to receive IMRT than 3D-CRT. IMRT became more common during the later years of the study. Patients receiving IMRT were more likely to receive >50 Gy, photon energy of {<=}6 MV, and >5 radiation fields than those who received 3D-CRT. The coverage of the IMRT planning target volume by the prescription dose was improved compared with the coverage using 3D-CRT with similar target dose heterogeneity. Conclusions: IMRT improved the target dose coverage compared with 3D-CRT, although an improvement in locoregional control or FFS could not be demonstrated in this population. Future studies comparing the integral dose to nontarget tissue and late radiation toxicity between the two groups are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modal survey test and model correlation of the CASSIOPE spacecraft

A comprehensive modal survey test based on multi-input multi-output experimental modal analysis techniques was conducted on the flight model of the CASSIOPE spacecraft in the final stages of integration, which included all of the payload and bus instruments and electronics boxes. The multiple-input excitation for the spacecraft was generated using two portable electrodynamic modal shakers installed on the top and bottom of the spacecraft to distribute the excitation energy and the response was measured using 81 miniature accelerometers. Advanced modal analysis software was used to extract modal parameters from the measured data and critical modes were compared with predictions from the finite element model. Most modes identified through the experimental data compared favorably with the predictions. Nevertheless, some differences were large enough to require iterative update of the finite element model. The structural dynamics information from the updated finite element model was used to plan the mechanical vibration qualification test and predict the response of the spacecraft to the launch vehicle environmental loads through coupled loads analysis to provide confidence in the structural integrity of the spacecraft design. This paper describes the details of the methodology used to perform the successful experimental modal test to efficiently extract the critical modes of the spacecraft to correlate with the model.

42 ENGINEERING↗

Ultrafast treatment plan optimization for volumetric modulated arc therapy (VMAT)

Purpose: To develop a novel aperture-based algorithm for volumetric modulated arc therapy (VMAT) treatment plan optimization with high quality and high efficiency. Methods: The VMAT optimization problem is formulated as a large-scale convex programming problem solved by a column generation approach. The authors consider a cost function consisting two terms, the first enforcing a desired dose distribution and the second guaranteeing a smooth dose rate variation between successive gantry angles. A gantry rotation is discretized into 180 beam angles and for each beam angle, only one MLC aperture is allowed. The apertures are generated one by one in a sequential way. At each iteration of the column generation method, a deliverable MLC aperture is generated for one of the unoccupied beam angles by solving a subproblem with the consideration of MLC mechanic constraints. A subsequent master problem is then solved to determine the dose rate at all currently generated apertures by minimizing the cost function. When all 180 beam angles are occupied, the optimization completes, yielding a set of deliverable apertures and associated dose rates that produce a high quality plan. Results: The algorithm was preliminarily tested on five prostate and five head-and-neck clinical cases, each with one full gantry rotation without any couch/collimator rotations. High quality VMAT plans have been generated for all ten cases with extremely high efficiency. It takes only 5-8 min on CPU (MATLAB code on an Intel Xeon 2.27 GHz CPU) and 18-31 s on GPU (CUDA code on an NVIDIA Tesla C1060 GPU card) to generate such plans. Conclusions: The authors have developed an aperture-based VMAT optimization algorithm which can generate clinically deliverable high quality treatment plans at very high efficiency.

61 RADIATION PROTECTION AND DOSIMETRY↗