Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Refinement of the crystal structure of the high-temperature phase G{sub 0} in (NH{sub 4}){sub 2}WO{sub 2}F{sub 4} (powder, X-ray, and neutron scattering)

The (NH{sub 4}){sub 2}WO{sub 2}F{sub 4} compound undergoes a series of phase transitions: G{sub 0} {yields} 201, K {yields} G{sub 1} {yields} 160, and K {yields} G{sub 2}, with a significant change in entropy ({Delta}S{sub 1} {approx} Rln10 at the G{sub 0} {yields} G{sub 1} transition), which indicates significant orientational disordering in the G{sub 0} phase and the order-disorder type of the phase transition. X-ray diffraction is used to identify the crystal structure of the G{sub 0} phase as rhombohedral (sp. gr. Cmcm, Z = 4), determine the lattice parameters and the positions of all atoms (except hydrogen), and show that [WO{sub 2}F{sub 4}]{sup 2-} ions can form a superposition of dynamic and static orientational disorders in the anionic sublattice. A determination of the orientational position of [NH{sub 4}]{sup +} ions calls for the combined method of elastic and inelastic neutron scattering. Inelastic neutron scattering is used to determine the state of hindered rotation for ammonium ions in the G{sub 0} phase. Powder neutron diffraction shows that the orientational disorder of NH{sub 4} ions can adequately be described within the free-rotation approximation.

36 MATERIALS SCIENCE↗

Performance Assessment of Suture Type, Water Temperature, and Surgeon Skill in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters

Size reductions of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the use of a shorter incision - one that may warrant only one suture for closure. However, it is not known if a single suture will sufficiently hold the incision closed when fish are decompressed and outward pressure is placed on the surgical site during passage of hydroelectric dams. The objectives of this study were to evaluate five response variables in juvenile Chinook salmon subjected to simulated turbine passage. Fish were implanted with an acoustic transmitter (0.43 g in air) and a passive integrated transponder tag (0.10 g in air); incisions (6 mm) were closed with either one or two sutures. Following exposure, no transmitters were expelled. In addition, suture and incision tearing and mortal injury did not differ between treatment and control fish. Viscera expulsion was higher in treatment (12%) than control (1%) fish. The higher incidence of viscera expulsion through single-suture incisions warrants concern. Consequently, the authors do not recommend using one suture to close 6-mm incisions associated with acoustic transmitter implantation when juvenile salmonids may be exposed to turbine passage.

Deters, Katherine A↗

Tunable Diode Laser Sensors to Monitor Temperature and Gas Composition in High-Temperature Coal Gasifiers

The integrated gasification combined cycle (IGCC) when combined with carbon capture and storage can be one of the cleanest methods of extracting energy from coal. Control of coal and biomass gasification processes to accommodate the changing character of input-fuel streams is required for practical implementation of integrated gasification combined-cycle (IGCC) technologies. Therefore a fast time-response sensor is needed for real-time monitoring of the composition and ideally the heating value of the synthesis gas (here called syngas) as it exits the gasifier. The goal of this project was the design, construction, and demonstration an in situ laserabsorption sensor to monitor multiple species in the syngas output from practical-scale coal gasifiers. This project investigated the hypothesis of using laser absorption sensing in particulateladen syngas. Absorption transitions were selected with design rules to optimize signal strength while minimizing interference from other species. Successful in situ measurements in the dusty, high-pressure syngas flow were enabled by Stanford’s normalized and scanned wavelength modulation strategy. A prototype sensor for CO, CH4, CO2, and H2O was refined with experiments conducted in the laboratory at Stanford University, a pilot-scale at the University of Utah, and an engineering-scale gasifier at DoE’s National Center for Carbon Capture with the demonstration of a prototype sensor with technical readiness level 6 in the 2014 measurement campaign.

01 COAL, LIGNITE, AND PEAT↗

Resistive Coatings for High-performance, Low-background MCPs Operating Across Broad Temperature Ranges and at Cryogenic Temperatures

Microchannel plate with improved thermo-electric properties are a high risk, high payoff development undertaken by a consortium of effort that links the Argonne National Lab, the Space-Science Lab at UC Berkeley and the small businesses (Incom Inc.) that will commercialize the advanced technology in open MCPs and LAPPDs. This development will satisfy the needs for new instrumentation for homeland security (non-proliferation) sensors to screen vehicles and cargo for Special Nuclear Materials (SNMs) and scientific detectors for astrophysics, electron microscopy, time-of-flight mass spectrometry, molecular and atomic collision studies, and fluorescence imaging applications in biotechnology and medical imaging products including positron emission tomography (PET scanning).

99 GENERAL AND MISCELLANEOUS↗