Characterizing Tradeoffs in Memory, Accuracy, and Speed for Chemistry Tabulation Techniques

Chemistry tabulation is a common approach in practical simulations of turbulent combustion at engineering scales. Linear interpolants have traditionally been used for accessing precomputed multidimensional tables but suffer from large memory requirements and discontinuous derivatives. Higher-degree interpolants address some of these restrictions but are similarly limited to relatively low-dimensional tabulation. Artificial neural networks (ANNs) can be used to overcome these limitations but cannot guarantee the same accuracy as interpolants and introduce challenges in reproducibility and reliable training. These challenges are enhanced as the physics complexity to be represented within the tabulation increases. Here, we assess the efficiency, accuracy, and memory requirements of Lagrange polynomials, tensor product B-splines, and ANNs as tabulation strategies. We analyze results in the context of nonadiabatic flamelet modeling where higher dimension counts are necessary. While ANNs do not require structuring of data, providing benefits for complex physics representation, interpolation approaches often rely on some structuring of the table. Interpolation using structured table inputs that are not directly related to the variables transported in a simulation can incur additional query costs. This is demonstrated in the present implementation of heat losses. We show that ANNs, despite being difficult to train and reproduce, can be advantageous for high-dimensional, unstructured datasets relevant to nonadiabatic flamelet models. Furthermore we demonstrate that Lagrange polynomials show significant speedup for similar accuracy compared to B-splines.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE LEGACY OF SCUPOL: 850 {mu}m IMAGING POLARIMETRY FROM 1997 TO 2005

SCUPOL, the polarimeter for SCUBA on the James Clerk Maxwell Telescope, was the most prolific thermal imaging polarimeter built to date. Between 1997 and 2005, observations of 104 regions were made at 850 {mu}m in the mapping mode. The instrument has produced {approx}50 refereed journal publications, and that number is still growing. We have systematically re-reduced all imaging polarimetry made in the standard 'jiggle-map' mode from the SCUBA archive (2800+ individual observations) to produce a catalog of SCUPOL images and tables. We present the results of our analysis with figures and data tables produced for all 83 regions where significant polarization was detected. In addition, the reduced data cubes and data tables can be accessed online. In many cases, the data included in this paper have been previously published elsewhere. However, this publication includes unpublished data sets, in whole or in part, toward 39 regions, including cores in {rho} Ophiuchus, Orion's OMC-2 region, several young stellar objects, and the galaxy M87.

79 ASTRONOMY AND ASTROPHYSICS↗

The effective field theory of dark matter direct detection

We extend and explore the general non-relativistic effective theory of dark matter (DM) direct detection. We describe the basic non-relativistic building blocks of operators and discuss their symmetry properties, writing down all Galilean-invariant operators up to quadratic order in momentum transfer arising from exchange of particles of spin 1 or less. Any DM particle theory can be translated into the coefficients of an effective operator and any effective operator can be simply related to most general description of the nuclear response. We find several operators which lead to novel nuclear responses. These responses differ significantly from the standard minimal WIMP cases in their relative coupling strengths to various elements, changing how the results from different experiments should be compared against each other. Response functions are evaluated for common DM targets — F, Na, Ge, I, and Xe — using standard shell model techniques. We point out that each of the nuclear responses is familiar from past studies of semi-leptonic electroweak interactions, and thus potentially testable in weak interaction studies. Here, we provide tables of the full set of required matrix elements at finite momentum transfer for a range of common elements, making a careful and fully model-independent analysis possible. Finally, we discuss embedding non-relativistic effective theory operators into UV models of dark matter.

dark matter detectors↗

Genetic analysis in the Collaborative Cross breeding population

Genetic reference populations in model organisms are critical resources for systems genetic analysis of disease related phenotypes. The breeding history of these inbred panels may influence detectable allelic and phenotypic diversity. The existing panel of common inbred strains reflects historical selection biases, and existing recombinant inbred panels have low allelic diversity. All such populations may be subject to consequences of inbreeding depression. The Collaborative Cross (CC) is a mouse reference population with high allelic diversity that is being constructed using a randomized breeding design that systematically outcrosses eight founder strains, followed by inbreeding to obtain new recombinant inbred strains. Five of the eight founders are common laboratory strains, and three are wild-derived. Since its inception, the partially inbred CC has been characterized for physiological, morphological, and behavioral traits. The construction of this population provided a unique opportunity to observe phenotypic variation as new allelic combinations arose through intercrossing and inbreeding to create new stable genetic combinations. Processes including inbreeding depression and its impact on allelic and phenotypic diversity were assessed. Phenotypic variation in the CC breeding population exceeds that of existing mouse genetic reference populations due to both high founder genetic diversity and novel epistatic combinations. However, some focal evidence of allele purging was detected including a suggestive QTL for litter size in a location of changing allele frequency. Despite these inescapable pressures, high diversity and precision for genetic mapping remain. These results demonstrate the potential of the CC population once completed and highlight implications for development of related populations. Supplementary material consists of Supplementary Table 1 Phenotypic means, variances, ranges and heritabilities for all traits and generations, Supplementary Table 2, all phenotypic values, Supplementary Table 3, multiple QTL mapping.

59 BASIC BIOLOGICAL SCIENCES↗

Aneutronic H + {sup 11}B nuclear fusion driven by Coulomb explosion of hydrogen nanodroplets

We consider a reaction design for table-top nuclear fusion between two distinct nuclei, with high-energy nuclei being produced by a Coulomb explosion (CE) of homonuclear nanodroplets of one reagent reacting with a solid target of a second reagent. This scheme was applied for a theoretical-computational study of the table-top aneutronic p+{sup 11}B{yields}3{alpha}+8.7 MeV reaction generated by a source of high-energy (0.3-6 MeV) protons produced by a CE of hydrogen nanodroplets driven by ultra-intense, femtosecond, near-infrared laser pulses and which penetrate into a solid {sup 11}B target. The averaged reaction probability and the yield for {sup 11}B(p,{alpha})2{alpha} fusion were calculated from the energy-dependent reaction probability, which was obtained from the ratio of the large fusion cross sections and the stopping power of the protons, and by the proton kinetic energy distribution function, which was obtained from scaled electron and ion dynamics simulations. The fusion yields were determined in the nanodroplet size range and in the laser intensity domain, satisfying the conditions of weak laser intensity attenuation within a single nanodroplet and within an assembly of exploding nanodroplets in the macroscopic plasma filament. The highest values of the fusion yield of 10{sup 8} per laser pulse were attained for the largest nanodroplets with initial radii of 200 nm at the laser peak intensity of 10{sup 19} W cm{sup -2}. The {sup 11}B(p,{alpha})2{alpha} fusion yields for the exploding hydrogen nanodroplet source-solid {sup 11}B cylindrical target are higher by three to four orders of magnitude than the yields of 10{sup 4}-10{sup 5} per laser pulse from a laser-irradiated mixed boron-hydrocarbon solid and from a CE of boron-hydrogen heteronuclear nanodroplets. The high efficiency for fusion within the exploding nanodroplets source-cylindrical solid target design provides guidelines for the optimization of yields for table-top nuclear fusion.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Erratum: Monoenergetic photon-induced fission cross-section ratio measurements for U 235 , U 238 , and Pu 239 from 9.0 to 17.0 MeV

In this erratum we report a correction to the previously published photofission cross-section ratio data. The actinide fission-chamber foils utilized in this work were extensively characterized during a new campaign using α- and γ-ray spectroscopy, and 2π alpha counting. These three techniques agreed, resulting in an improved accuracy of the fission-chamber foil masses used in the original experiment. The foil masses measured by α spectroscopy are detailed in Table I. All foils were counted on the same α spectrometer, using an identical geometry, which reduces the systematic uncertainty in the calculated mass ratios since the α spectrometer efficiency cancels out in the ratio. This results in a relative uncertainty on the mass ratio of 1.0% for 235 U/ 238 U, 0.62% for 239 Pu/ 235 U, and 1.1% for 239 Pu/ 238 U. The published cross-section ratio data are re-calculated to reflect the updated target masses and uncertainties. The new mass values cause a 2.40% decrease for the σ( 235 U(γ, f)/ 238 U(γ, f)) ratio, a 5.10% decrease for the σ( 235 U(γ, f)/ 239 Pu(γ, f)) ratio, and a 2.77% decrease for the σ( 238 U(γ, f)/ 239 Pu(γ, f)) ratio. The updated cross-section ratios are presented in Tables II, III, and IV, which are corrected versions of Tables III, IV, and V in Ref. [1]

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

First-principles equation of state of CHON resin for inertial confinement fusion applications

A wide-range (0 to 1044.0 g/ cm 3 and 0 to 10 9 K) equation-of-state (EOS) table for a CH 1.72 O 0.37 N 0.086 quaternary compound has been constructed based on density-functional theory (DFT) molecular-dynamics (MD) calculations using a combination of Kohn-Sham DFT MD, orbital-free DFT MD, and numerical extrapolation. The first-principles EOS data are compared with predictions of simple models, including the fully ionized ideal gas and the Fermi-degenerate electron gas models, to chart their temperature-density conditions of applicability. The shock Hugoniot, thermodynamic properties, and bulk sound velocities are predicted based on the EOS table and compared to those of C-H compounds. The Hugoniot results show the maximum compression ratio of the C-H-O-N resin is larger than that of CH polystyrene due to the existence of oxygen and nitrogen; while the other properties are similar between CHON and CH. Radiation hydrodynamic simulations have been performed using the table for inertial confinement fusion targets with a CHON ablator and compared with a similar design with CH. Here, the simulations show CHON outperforms CH as the ablator for laser-direct-drive target designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PlantFAdb: a resource for exploring hundreds of plant fatty acid structures synthesized by thousands of plants and their phylogenetic relationships

Over 450 structurally distinct fatty acids are synthesized by plants. We have developed PlantFAdb.org, an internet-based database that allows users to search and display fatty acid composition data for over 9000 plants. PlantFAdb includes more than 17 000 data tables from >3000 publications and hundreds of unpublished analyses. This unique feature allows users to easily explore chemotaxonomic relationships between fatty acid structures and plant species by displaying these relationships on dynamic phylogenetic trees. Users can navigate between order, family, genus and species by clicking on nodes in the tree. The weight percentage of a selected fatty acid is indicated on phylogenetic trees and clicking in the graph leads to underlying data tables and publications. The display of chemotaxonomy allows users to quickly explore the diversity of plant species that produce each fatty acid and that can provide insights into the evolution of biosynthetic pathways. Fatty acid compositions and other parameters from each plant species have also been compiled from multiple publications on a single page in graphical form. Links provide simple and intuitive navigation between fatty acid structures, plant species, data tables and the publications that underlie the datasets. In addition to providing an introduction to this resource, this report illustrates examples of insights that can be derived from PlantFAdb. Based on the number of plant families and orders that have not yet been surveyed we estimate that a large number of novel fatty acid structures are still to be discovered in plants.

59 BASIC BIOLOGICAL SCIENCES↗

MODELING A SPENT NUCLEAR FUEL CASK SEISMIC TEST

The US Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is planning to conduct a series of full-scale shake table tests to simulate hypothetical earthquake conditions and record the response of surrogate spent nuclear fuel (SNF) assemblies in a canister dry storage system mockup. The shake table motions will represent a range of hypothetical earthquake conditions at hypothetical locations in the continental US to generally define the range of mechanical loads that SNF can be expected to experience during extended dry storage periods. The earthquake conditions will represent seismic hazards in the 2,000-to-20,000-year return period range. The test will use instrumented pressurized water reactor fuel assemblies with surrogate mass inside the fuel rods instead of radioactive fuel pellets. Dummy assemblies with similar mass and dimensions to actual fuel assemblies will occupy the rest of the fuel assembly locations in a SNF canister that holds 32 fuel assemblies. The canister will be located inside a mockup vertical concrete cask. Instrumentation will record the motion of the major components of the complex dynamic system, and strain gauges will be used to record the cladding strain at select locations. Preparations for the test require modeling predictions to identify the range of response of the system and to help select specific earthquake cases to be simulated on the shake table from a large set of potential cases. This paper describes the pretest nonlinear finite element modeling efforts that have been completed to date, including cask system level modeling and fuel assembly modeling in LS-DYNA. The cask system level models are critical for anticipating sliding or tipping of an unanchored cask during the test. The fuel assembly model is needed to estimate the range of cladding strain response and fuel assembly structural response to be expected during the test and cladding strain measurements will be key metrics for model validation and the development of modeling best practices after the test is concluded.

Klymyshyn, Nicholas A.↗

Evaluation of a new IR-guided system for mechanical QA of linear accelerators

The authors report the development of a new procedure for mechanical quality assurance of linear accelerators using an infrared-guided system. The system consists of an infrared (IR) camera and an IR-reflective marker that can be attached to a gantry, a collimator, or a treatment table. The trace of this marker can be obtained in three dimensions (3D) for a full or partial rotation of the mechanical devices. The software is written to localize rotational axes of the gantry, collimator, and the treatment table based on the marker traces. The separation of these axes characterizes the size of the sphere defining the mechanical isocenter. Additional information on anomalies in gantry movement such as degree of gantry sag and hysteresis can also be obtained. An intrinsic uncertainty of the system to localize rotational axis is 0.35 mm or less. Tests on a linear accelerator demonstrated the ability of this system to detect the separation between rotational axes of less than 1 mm and to confirm orthogonality of the planes of gantry, collimator, and table rotation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for optimizing LINAC treatment geometry for volumetric modulated arc therapy of multiple brain metastases

Purpose: Volumetric modulated arc therapy (VMAT) is a rotational delivery technique in which MLC shapes, dose rate, and gantry rotation speed are optimized to produce conformal dose distributions. The aim of this work is to develop a beam projection method for deriving the optimal table and collimator angles for multilesion treatment planning. Methods: The method consists of four steps. The first step is to define the vector of beam-eye-view (BEV)-Y-axis in the treatment planning CT coordinates. The second step is to project each target onto the BEV-Y-axis vector. In the third step, the best table and collimator angle are found with a brute-force optimization technique that minimizes MLC leaf sharing between lesions. The fourth step is to generate an optimized VMAT plan with appropriate table/collimator angles and evaluate the plan quality. Results: The authors tested the method on three example cases with targets of various locations in the brain and sizes ranging from 1.18 to 17.86 cm{sup 3}. Applying the optimized geometric parameter to generate VMAT plan, a reduction of the 12 Gy volume was more than 6.1% for all cases; the plan homogeneity (D{sub 2%}-D{sub 95%}) was improved from 5.88{+-}1.21 to 5.21{+-}0.93 Gy vs a VMAT plan with the manufacturer recommended table and collimator angles. Conclusions: The authors conclude that the use of the projection method minimizes the sharing of MLC leaves between lesions and improves the plan quality for multilesion VMAT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Skin dose mapping for fluoroscopically guided interventions

Purpose: To introduce a new skin dose mapping software system for interventional fluoroscopy dose assessment and to analyze the benefits and limitations of patient-phantom matching. Methods: In this study, a new software system was developed for visualizing patient skin dose during interventional fluoroscopy procedures. The system works by translating the reference point air kerma to the location of the patient's skin, which is represented by a computational model. In order to orient the model with the x-ray source, geometric parameters found within the radiation dose structured report (RDSR) are used along with a limited number of in-clinic measurements. The output of the system is a visual indication of skin dose mapped onto an anthropomorphic model at a resolution of 5 mm. In order to determine if patient-dependent and patient-sculpted models increase accuracy, peak skin dose was calculated for each of 26 patient-specific models and compared with doses calculated using an elliptical stylized model, a reference hybrid model, a matched patient-dependent model and one patient-sculpted model. Results were analyzed in terms of a percent difference using the doses calculated using the patient-specific model as the true standard. Results: Anthropometric matching, including the use of both patient-dependent and patient-sculpted phantoms, was shown most beneficial for left lateral and anterior-posterior projections. In these cases, the percent difference using a reference model was between 8 and 20%, using a patient-dependent model between 7 and 15%, and using a patient-sculpted model between 3 and 7%. Under the table tube configurations produced errors less than 5% in most situations due to the flattening affects of the table and pad, and the fact that table height is the main determination of source-to-skin distance for these configurations. In addition to these results, several skin dose maps were produced and a prototype display system was placed on the in-clinic monitor of an interventional fluoroscopy system. Conclusions: The skin dose mapping program developed in this work represents a new tool that, as the RDSR becomes available through automated export or real-time streaming, can provide the interventional physician information needed to modify behavior when clinically appropriate. The program is nonproprietary and transferable, and also functions independent to the software systems already installed on the control room workstation. The next step will be clinical implementation where the workflow will be optimized along with further analysis of real-time capabilities.

61 RADIATION PROTECTION AND DOSIMETRY↗

A robust geometry estimation method for spiral, sequential and circular cone-beam micro-CT

Purpose: The authors propose a novel method for misalignment estimation of micro-CT scanners using an adaptive genetic algorithm. Methods: The proposed algorithm is able to estimate the rotational geometry, the direction vector of table movement and the displacement between different imaging threads of a dual source or even multisource scanner. The calibration procedure does not rely on dedicated calibration phantoms and a sequence scan of a single metal bead is sufficient to geometrically calibrate the whole imaging system for spiral, sequential, and circular scan protocols. Dual source spiral and sequential scan protocols in micro-computed tomography result in projection data that-besides the source and detector positions and orientations-also require a precise knowledge of the table direction vector to be reconstructed properly. If those geometric parameters are not known accurately severe artifacts and a loss in spatial resolution appear in the reconstructed images as long as no geometry calibration is performed. The table direction vector is further required to ensure that consecutive volumes of a sequence scan can be stitched together and to allow the reconstruction of spiral data at all. Results: The algorithm's performance is evaluated using simulations of a micro-CT system with known geometry and misalignment. To assess the quality of the algorithm in a real world scenario the calibration of a micro-CT scanner is performed and several reconstructions with and without geometry estimation are presented. Conclusions: The results indicate that the algorithm successfully estimates all geometry parameters, misalignment artifacts in the reconstructed volumes vanish, and the spatial resolution is increased as can be shown by the evaluation of modulation transfer function measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Real-time catheter tracking for high-dose-rate prostate brachytherapy using an electromagnetic 3D-guidance device: A preliminary performance study

Purpose: In order to increase the accuracy and speed of catheter reconstruction in a high-dose-rate (HDR) prostate implant procedure, an automatic tracking system has been developed using an electromagnetic (EM) device (trakSTAR, Ascension Technology, VT). The performance of the system, including the accuracy and noise level with various tracking parameters and conditions, were investigated. Methods: A direct current (dc) EM transmitter (midrange model) and a sensor with diameter of 1.3 mm (Model 130) were used in the trakSTAR system for tracking catheter position during HDR prostate brachytherapy. Localization accuracy was assessed under both static and dynamic analyses conditions. For the static analysis, a calibration phantom was used to investigate error dependency on operating room (OR) table height (bottom vs midposition vs top), sensor position (distal tip of catheter vs connector end of catheter), direction [left-right (LR) vs anterior-posterior (AP) vs superior-inferior (SI)], sampling frequency (40 vs 80 vs 120 Hz), and interference from OR equipment (present vs absent). The mean and standard deviation of the localization offset in each direction and the corresponding error vectors were calculated. For dynamic analysis, the paths of five straight catheters were tracked to study the effects of directions, sampling frequency, and interference of EM field. Statistical analysis was conducted to compare the results in different configurations. Results: When interference was present in the static analysis, the error vectors were significantly higher at the top table position (3.3 {+-} 1.3 vs 1.8 {+-} 0.9 mm at bottom and 1.7 {+-} 1.0 mm at middle, p < 0.001), at catheter end position (3.1 {+-} 1.1 vs 1.4 {+-} 0.7 mm at the tip position, p < 0.001), and at 40 Hz sampling frequency (2.6 {+-} 1.1 vs 2.4 {+-} 1.5 mm at 80 Hz and 1.8 {+-} 1.1 at 160 Hz, p < 0.001). So did the mean offset errors in the LR direction (-1.7 {+-} 1.4 vs 0.4 {+-} 0.5 mm in AP and 0.8 {+-} 0.8 mm in SI directions, p < 0.001). The error vectors were significantly higher with surrounding interference (2.2 {+-} 1.3 mm) vs without interference (1.0 {+-} 0.7 mm, p < 0.001). An accuracy of 1.6 {+-} 0.2 mm can be reached when using optimum configuration (160 Hz at middle table position). When interference was present in the dynamic tracking, the mean tracking errors in LR direction (1.4 {+-} 0.5 mm) was significantly higher than that in AP direction (0.3 {+-} 0.2 mm, p < 0.001). So did the mean vector errors at 40 Hz (2.1 {+-} 0.2 mm vs 1.3 {+-} 0.2 mm at 80 Hz and 0.9 {+-} 0.2 mm at 160 Hz, p < 0.05). However, when interference was absent, they were comparable in the both directions and at all sampling frequencies. An accuracy of 0.9 {+-} 0.2 mm was obtained for the dynamic tracking when using optimum configuration. Conclusions: The performance of an EM tracking system depends highly on the system configuration and surrounding environment. The accuracy of EM tracking for catheter reconstruction in a prostate HDR brachytherapy procedure can be improved by reducing interference from surrounding equipment, decreasing distance from transmitter to tracking area, and choosing appropriated sampling frequency. A calibration scheme is needed to further reduce the tracking error when the interference is high.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: The GammaPod Trade-Mark-Sign

Purpose: A dedicated stereotactic gamma irradiation device, the GammaPod Trade-Mark-Sign from Xcision Medical Systems, was developed specifically to treat small breast cancers. This study presents the first evaluation of dosimetric and geometric characteristics from the initial prototype installed at University of Maryland Radiation Oncology Department. Methods: The GammaPod Trade-Mark-Sign stereotactic radiotherapy device is an assembly of a hemi-spherical source carrier containing 36 {sup 60}Co sources, a tungsten collimator, a dynamically controlled patient support table, and the breast immobilization system which also functions as a stereotactic frame. The source carrier contains the sources in six columns spaced longitudinally at 60 Degree-Sign intervals and it rotates together with the variable-size collimator to form 36 noncoplanar, concentric arcs focused at the isocenter. The patient support table enables motion in three dimensions to position the patient tumor at the focal point of the irradiation. The table moves continuously in three cardinal dimensions during treatment to provide dynamic shaping of the dose distribution. The breast is immobilized using a breast cup applying a small negative pressure, where the immobilization cup is embedded with fiducials also functioning as the stereotactic frame for the breast. Geometric and dosimetric evaluations of the system as well as a protocol for absorbed dose calibration are provided. Dosimetric verifications of dynamically delivered patient plans are performed for seven patients using radiochromic films in hypothetical preop, postop, and target-in-target treatment scenarios. Results: Loaded with 36 {sup 60}Co sources with cumulative activity of 4320 Ci, the prototype GammaPod Trade-Mark-Sign unit delivers 5.31 Gy/min at the isocenter using the largest 2.5 cm diameter collimator. Due to the noncoplanar beam arrangement and dynamic dose shaping features, the GammaPod Trade-Mark-Sign device is found to deliver uniform doses to targets with good conformity. The spatial accuracy of the device to locate the radiation isocenter is determined to be less than 1 mm. Single shot profiles with 2.5 cm collimator are measured with radiochromic film and found to be in good agreement with respect to the Monte Carlo based calculations (congruence of FWHM less than 1 mm). Dosimetric verifications corresponding to all hypothetical treatment plans corresponding to three target scenarios for each of the seven patients demonstrated good agreement with gamma index pass rates of better than 97% (99.0%{+-} 0.7%). Conclusions: Dosimetric evaluation of the first GammaPod Trade-Mark-Sign stereotactic breast radiotherapy unit was performed and the dosimetric and spatial accuracy of this novel technology is found to be feasible with respect to clinical radiotherapy standards. The observed level of agreement between the treatment planning system calculations and dosimetric measurements has confirmed that the system can deliver highly complex treatment plans with remarkable geometric and dosimetric accuracy.

60 APPLIED LIFE SCIENCES↗

Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the technical basis for the clinical integration of PET/MR hybrid imaging into RT treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-E-J-162: Quality Assurance Procedures for MR Guided Focused Ultrasound Treatment of Bone Metastasis

Purpose: The purpose of this work is to develop and verify our quality assurance (QA) procedures to ensure the safety and efficacy of MR-guided focused ultrasound (MRgFUS) treatment of bone metastases. Methods: A practical QA program was developed. Monthly and daily QA (DQA) procedures were performed. The major QA items included the checks of the machine hardware, software and patient safety features. Briefly, these checks/tests include: 1) the cooling system reservoir and treatment table; 2) power to the treatment table; 3) the MR coil; 4) the transducer position with MRI; 5) image display on the treatment work station; 6) the effective focal spot in 3 directions using MR thermometry; and 7) all the safety devices including a sonication lamp, and the emergency stop-sonication switches. In order to avoid patient skin burn, it is important to remove gas bubbles in the interfaces between the treatment table and the gel pad, and the gel pad and patients skin during the patient setup. Our QA procedures have been verified and evaluated through patient treatments. Seven patients with scapula, humeral head, sacrum, ilium, pubic ramus and acetabular bone metastases were treated using MRgFUS. Results: Our study showed that all seven patients tolerated the MRgFUS treatment well. No skin toxicity or other complications were observed. The pain score (0–10) using the visual analog scale (VAS) was significantly reduced from 8.0 ± 1.1 before treatment to 4.7 ± 3.0, 3.0 ± 1.5, 3.2 ± 2.8 and 3.4 ± 1.5 at one day, one month, two months and three months after the MRgFUS treatment, respectively. Conclusion: We demonstrated that with the appropriate QA procedures, MRgFUS is a safe, effective and noninvasive treatment modality for palliation of bone metastases.

60 APPLIED LIFE SCIENCES↗

SU-E-T-246: MU Model Implementation for a Passively Scattered Proton Beam: Inclusion of the Bolus Gap and Nozzle Extension Factors

Purpose: To develop and implement an MU model for a passively scattered proton beam, and eliminate the need for patient specific calibrations for field sizes from 3cm to 15cm. This would enable consistent and timely calibrations for a wide variety of patient portals, streamlining the treatment process. Methods: Measurements were initially made using a Standard Imaging A-16 ion chamber and a modified water tank to determine the bolus gap factors (BGF) for multiple combinations of aperture size, bolus thickness, and air gap. The BGF was then separated into two component factors: the bolus thickness factor (BTF) and the nozzle extension factor (NEF). Polynomial curves were generated using the measured data to produce BTF tables for air gaps from 0cm to 30cm and for bolus thicknesses from 0cm to 10cm, and NEF tables for the full range of clinically used nozzle extensions. Additionally, data tables were created for every factor that affects beam output in the MU model. The MUs were then modeled for 487 patient portals and retrospectively compared to the MUs generated from the physical calibrations previously performed. Results: Of the 487 patient portals tested, 100% of the portals used for the comparison were within 2.5% from the MUs generated using a physical calibration, and 95.9% of the MU model portals tested were within 2%. The patient portals tested had field sizes ranging from 2.1cm to 10.1cm, with air gaps from 2cm to 25cm. Output factors for field sizes below 3cm with irregularly shaped fields demonstrated inconsistent results and will be further studied. Conclusion: The most problematic output factor, the BGF, was modeled accurately and consistently using the lowest order polynomial curve fits and interpolation between measured data. The study results demonstrate the robustness of the MU model and the potential for saving valuable personnel and beam time.

07 ISOTOPE AND RADIATION SOURCES↗