Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sterilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Viking lander spacecraft battery

The Viking Lander was the first spacecraft to fly a sterilized nickel-cadmium battery on a mission to explore the surface of a planet. The significant results of the battery development program from its inception through the design, manufacture, and test of the flight batteries which were flown on the two Lander spacecraft are documented. The flight performance during the early phase of the mission is also presented.

Newell, D. R.↗

Screwworm Eradication Data System (SEDS) applications program documentation, part 2

National Oceanic and Atmospheric Administration (NOAA) satellite data, which is in analog tape form, is converted into output data products. These products are used by investigators in determining optimum areas for airdrops of steril screwworm flies over Mexico. The output product of SEDS takes the form of imagery data film slides showing Mexico and the lower southwest portion of the United States. The area analog preprocessing phase of the SEDS task is covered.

Source record↗

Viking labeled release biology experiment - Interim results

All results of the labeled-release life-detection experiment conducted on Mars prior to conjunction are summarized. Tests at both landing sites provide remarkably similar evolution of radioactive gas upon addition of a radioactive nutrient to the Mars sample. The 'active' agent in the sample is stable to 18 C, but is substantially inactivated by heat treatment for 3 hours at 50 C and completely inactivated at 160 C, as would be anticipated if the active response were caused by microorganisms. Results from test and heat-sterilized control samples are compared with those obtained from terrestrial soils and a lunar sample. Possible nonbiological explanations of the Mars data are reviewed. Although such explanations of the labeled-release data depend on UV irradiation, the labeled-release response does not appear to depend on recent direct UV activation of surface material. Available facts do not yet permit a conclusion regarding the existence of life on Mars.

Levin, G. V.↗

Effect of 30 months in a locked environment on the microbial flora of dogs

It has been proposed that the microbial flora of mammals would simplify to a few microbial species if the host animal was confined to a 'locked' environment and provided with sterile food, water, and air. This paper updates information on the microbial profile (feces, nose and throat) of purebred beagles housed in the above-mentioned conditions through a 30-month study period and demonstrates that no drastic decrease or simplification of the microbial profile occurred in isolated or control dogs.

Balish, E.↗

Fibre evaluation for spacecraft cleaning

The employment of vacuum brushes utilizing sable tail hair for the physical removal of particulates from spacecraft surfaces has become problematical in connection with a lack of compatibility of the bristle with sterilization and biological decontamination procedures required for spacecraft cleaning. An investigation was, therefore, conducted to find a suitable fiber which can replace sable bristle. Felor fiber was found to have the best properties for use in a motorized cleaning brush.

Jensen, W. M.↗

Microbiological profiles of the Viking spacecraft

Planetary quarantine requirements associated with the launch of two Viking spacecraft necessitated microbiological assessment during assembly and testing at Cape Canaveral and the Kennedy Space Center. Samples were collected from the Viking Lander Capsules (VLC), Orbiters (VO), and Shrouds at predetermined intervals during assembly and testing. Levels of bacterial spores per square meter on the VLC-1 and VLC-2 were 1.6 x 10 squared and 9.7, respectively, prior to dry-heat sterilization. The ranges of aerobic mesophilic microorganisms detected on the VO-1 and VO-2 were 4.2 x 10 squared to 4.3 x 10 cubed and 2.3 x 10 squared to 8.9 x 10 cubed/sq m, respectively. Approximately 1300 colonies were picked from culture plates, identified, lyophilized, and stored for future reference. About 75% of all isolates were microorganisms considered indigenous to humans; the remaining isolates were associated with soil and dust. The percentage of microorganisms of human origin was consistent with results obtained with previous automated spacecraft but slightly lower than those observed for manned (Apollo) spacecraft.

Puleo, J. R.↗

Automated electrochemical selection of coliforms

Computer-controlled sensor system monitors and quantifies coliform organisms in waste water samples through molecular hydrogen detection techniques. System includes cleanup procedures, external sterilization of each sensor interface with working fluid as well as incubation cell interiors. Sensor system may also be operated manually.

Taylor, R. E.↗

Microbial load monitor

Design analysis of a microbial load monitor system flight engineering model was presented. Checkout of the card taper and media pump system was fabricated as well as the final two incubating reading heads, the sample receiving and card loading device assembly, related sterility testing, and software. Progress in these areas was summarized.

Caplin, R. S.↗

Recent results from the Viking Labeled Release experiment on Mars

The Labeled Release (LR) life detection experiment seeks detection of heterotrophic metabolism by monitoring radio-active gas evolution following the addition of a radioactive nutrient containing seven C-14 labeled organic substrates to surface material. LR results obtained on Mars prior to conjunction showed rapid evolution of radioactive counts upon addition of the nutrient to a fresh surface sample. The responses at both landing sites were quite similar. The additional results summarized in the present paper provide further information on the gas kinetics following a second injection of nutrient and on the effect of 'cold sterilization' of the Martian surface material. Specifically, it is shown that the production of gas from the LR nutrient is remarkably uniform; after reaction approaches completion, addition of more nutrient results in a net loss of the radioactive gas; the reactant in the Mars soil is completely inhibited by heating the soil to 160 C, and is largely inhibited by heating to 46 C. In contrast, exposure to 18 C for 2 sol (1 sol = 24.6 hr) does not appear to inhibit the reaction.

Levin, G. V.↗

Survival and reversion of a stable L form in soil

The stable L form of Agromyces ramosus reverted to a bacterial form when incubated in sterilized soil. The cellular and colonial morphology of this bacterial form resembled that of the original parent bacterial form. The two forms differed, however, in that the revertant maintained its bacterial form when transferred onto a low-salt (NaCl) medium but was virtually completely induced into the L-form state on a high-salt medium. The original parent bacterial form was not sensitive to salt. The possibility is discussed that an L-form - bacterial-form cycle for this bacterium might occur naturally in soil. This cycle would be mediated by fluctuations in local salt concentrations in the soil.

Horwitz, A. H.↗

A subcutaneous channeling probe for implanting long leads

The channeling probe described in the present paper was designed to overcome surgical problems of the type that were encountered when a multichannel radio transmitter had to be implanted in a cow. The probe was made of a flexible but sufficiently stiff 9.5-mm-diam nylon rod, consisting of 46-cm sections for convenience in sterilization and surgical handling. Stainless steel sleaves reinforced the threaded connecting joints. At one end, arrowhead-shaped channeling heads could be attached to produce wide channels for large sensors. The other end was tapered for narrow channels. Postoperative problems were not encountered in the use of this probe in cows, sheep, and dogs.

Lund, G. F.↗

Operational Loopwheel Suspension System for Mars Rover Demonstration Model

The loopwheel (or elastic loop) mobility concept, appears to be uniquely qualified to provide a high degree of mobility at low weight and stowage requirements for the next Mars mission now in the early planning stage. Traction elements compatible with sterilization and Mars surface environmental constraints were designed and are compatible with the rover mass, range and stowage requirements of JPL's point design Mars rover. In order to save cost, the loopwheel suspensions for the demonstration model were made of S-glass/epoxy instead of titanium, alloy specified for flight units. The load carrying fiberglass loop core is covered by a rubber tread on the outside. Reinforced rubber gear belts bonded along the inside edges provide positive engagement and transmission drive torques. A 12 Vdc drive motor with a 167:1 gear head is installed in the payload section of the hull. A chain drive transmits the motor power to the rear sprocket in the demonstration model, whereas future flight units would be directly driven by brushless hub motors within each sprocket and independent four-leg height control.

Trautwein, W.↗

Infrared analysis of polyethylene wear specimens using attenuated total reflection spectroscopy

Attenuated total reflection infrared spectroscopy was used to analyze ultrahigh molecular weight polyethylene wear test specimens. Three different specimens were analyzed. One specimen was gamma irradiated to a dose of 5.0 MRad, another to a dose of 2.5 MRad, and the final specimen was unirradiated. There was no conclusive evidence of chemical changes (i.e., unsaturation or oxidation) in the surface regions of any of the polyethylene samples. Therefore, it was concluded that the gamma irradiation sterilization procedure shoud not alter the boundary lubricating properties of the polyethylene.

Jones, W. R.↗

Flow sensor for biomedical fluids

Electronic sensor accurately measures and controls flow of plasma, whole blood, or drugs in solution. Since sensor does not directly contact fluid, it does not have to be sterilized. It is compatible with disposable bottles, tubes, and hypodermic needles widely used in hospitals. Only modification necessary is in tube, which must contain two small metal inserts, spaced to fit in curved thermistor plates.

Winkler, H. E.↗

Plants and weightlessness

The growth of two plants, wall cress and short-day red goosefoot, was traced for their entire lifetime in weightlessness. In the beginning both plants grew normally: the seeds sprouted in the normal periods, and the shoots did not differ in any way from the control plants. It is true that certain roots lost their normal orientation and did not go deeper into the nutrient medium, but rather crept over its surface. But then both the wall cress and the goosefoot slowed down their normal rate of growth, which became noticeable from the rate of formation of new leaves in the wall cress and stem development in the goosefoot. Although no disorders were successfully found in the morphology of the two plants, almost half of the experimental cress and goosefoot plants ceased growth completely, yellowed and died. The other part continued to develop normally and by the end of vegetation, differed from the control plants only in a lower height. Not all were fertile since certain experimental plants, after losing spatial orientation, became twisted and produced sterile flowers.

Karminskiy, V.↗

Method and automated apparatus for detecting coliform organisms

Method and automated apparatus are disclosed for determining the time of detection of metabolically produced hydrogen by coliform bacteria cultured in an electroanalytical cell from the time the cell is inoculated with the bacteria. The detection time data provides bacteria concentration values. The apparatus is sequenced and controlled by a digital computer to discharge a spent sample, clean and sterilize the culture cell, provide a bacteria nutrient into the cell, control the temperature of the nutrient, inoculate the nutrient with a bacteria sample, measures the electrical potential difference produced by the cell, and measures the time of detection from inoculation.

Dill, W. P.↗

Microbial Sulfate Reduction Measured by an Automated Electrical Impedance Technique

Electrical impedance measurements are used to investigate the rates of sulfate reduction by pure cultures of and sediments containing sulfur-reducing bacteria. Changes in the electrical impedance ratios of pure cultures of Desulfovibrio aestuarii and samples of reduced sediments from San Francisco Bay were measured by a Bactometer 32, and sulfate reduction was followed by measuring the incorporation of (S-35) sulfate into metal sulfides. The growth of the bacteria in pure culture is found to result in an increase of 0.2200 in the impedance ratio within 24 h, accompanied by increases in protein, ATP, sulfide and absorptance at 660 nm, all of which are inhibited by the addition of molybdate. Similar responses were observed in the sediments, although impedance ratio responses were not completely inhibited upon the addition of molybdate, due to the presence of nonsulfate-respiring microorganisms. Experiments conducted with sterile media and autoclaved sediments indicate that the presence of H2S together with iron is responsible for the impedance effect, and sulfate reduction rates ranging between 0.85 and 1.78 mmol/l per day are estimated for the sediments by the impedance technique.

Oremland, R. S.↗

Some final conclusions and supporting experiments related to the search for organic compounds on the surface of Mars

The Viking molecular analysis experiment has demonstrated the absence (within the detection limits which range from levels of parts per million to below parts per billion) of organic substances in the Martian surface soil at the two Viking landing sites. Laboratory experiments with sterile and nonsterile antarctic samples further demonstrate the capability and reliability of the instrument. The circumstances under which organic components could have escaped detection, such as inaccessibility or extreme thermal stability of organic polymers, are discussed but are found to be unlikely. The inability of the instrument to detect free oxygen evolved from soil samples is pointed out.

Biemann, K.↗