Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spectrometry data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Automated Clean Chemistry for Bulk Analysis of Environmental Swipe Samples – Final Report

Sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment to shorten lengthy and costly manual chemical purification procedures. This development addresses a serious need in the International Atomic Energy Agency’s (IAEA) Network of Analytical Laboratories (NWAL) to increase efficiency in the Bulk Analysis of Environmental Samples for Safeguards program with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc. (ESI), the prepFAST-MC2 was designed based on COTS equipment. It was modified for uranium/plutonium separations using renewable columns packed with Eichrom TEVA® and UTEVA® resins, with a chemical separation method based on the Oak Ridge National Laboratory (ORNL) NWAL chemical procedure. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. Based on the initial experience at ORNL with the prepFAST-MC2, a second-generation model, the prepFAST-SR, was built by ESI. The newly designed prepFAST-SR has several upgrades compared with the original prepFAST-MC2. The upgrades largely addressed issues with the reliability of unpacking the Eichrom columns and with ventilation to ensure adequate removal of acid vapors. Both systems are currently installed in the Ultra-Trace Forensics Science Center at ORNL. Separations of mixed uranium and plutonium samples containing certified reference materials were analyzed by multi-collector inductively coupled plasma mass spectrometry and yielded good results. Current efforts have demonstrated a wider applicability of the prepFAST system. Near-quantitative removal of metal interferences was achieved with the system in both uranium and plutonium separated fractions. Successful system validation was completed with several archived samples. Isotopic results from archived samples and certified reference materials were well within data quality limits for the IAEA NWAL. Additional COTS equipment has been evaluated for its potential to aid the prepFAST-SR system in reducing the time allotments and cleanroom infrastructure requirements for accurate separations. Overall, these efforts help ensure continued efficient and effective operation of the NWAL. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced cost by limiting personnel hours dedicated to the chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rhenium-osmium isotope systematics in meteorites. I - Magmatic iron meteorite groups IIAB and IIIAB

Resonance ionization mass spectrometry is used to determine the Re and Os abundances by isotope dilution (ID) and to measure Os-187/Os-186 ratios from 19 iron meteorites. Abundances range from 1.4 to 4800 ppb Re, and from 13 to 65,000 ppb Os, and generally agree well with previous ID and neutron activation results. The Re and Os data suggest that abundance trends in these iron groups may be entirely explained by fractional crystallization. Whole-rock isochrons for the IIAB and IIIAB groups are statistically indistinguishable. Pooled data yield an initial Os-187/Os-186 of 0.794 +/- 0.010 Ga. Given the errors in the slope and half life, this age does not differ significantly from the canonical chondrite age of 4.56 Ga, but could be as young as 4.46 Ga.

Morgan, John W.↗

Advanced Mass Calibration and Visualization for FT-ICR Mass Spectrometry Imaging

Mass spectrometry imaging by Fourier transform ion cyclotron resonance (FT-ICR) yields hundreds of unique peaks, many of which cannot be resolved by lower performance mass spectrometers. The high mass accuracy and high mass resolving power allow confident identification of small molecules and lipids directly from biological tissue sections. Here, calibration strategies for FT-ICR MS imaging were investigated. Sub-parts-per-million mass accuracy is demonstrated over an entire tissue section. Ion abundance fluctuations are corrected by addition of total and relative ion abundances for a root-mean-square error of 0.158 ppm on 16,764 peaks. A new approach for visualization of FT-ICR MS imaging data at high resolution is presented. The "Mosaic Datacube" provides a flexible means to visualize the entire mass range at a mass spectral bin width of 0.001 Da. The high resolution Mosaic Datacube resolves spectral features not visible at lower bin widths, while retaining the high mass accuracy from the calibration methods discussed.

Environmental Molecular Sciences Laboratory↗

Pyrolysis_Molecular_Beam_Mass_Spectrometry_Analysis_of_hybrid_cross_of_Populus_tremula_x_P_alba_717-1B4_and_overexpression_of_a_lectin_receptor-like_kinase_(PtLecRLK1)

Stem tissues from the hybrid poplarPopulus tremula × P. albaclone 717-1B4 and from lectin receptor-like kinase overexpression lines PP7 and PP19 were individually colonized with the ectomycorrhizal fungiLaccaria bicolorstrain S238N,Hyaloscypha finlandicastrain PMI746, orUmbelopsis vinaceastrain PMI3018, as well as with a mixed fungal inoculum; non-inoculated plants served as controls. Plants were grown in a greenhouse at Oak Ridge National Laboratory and harvested in January 2025. Stem samples were analyzed using Pyrolysis–Molecular Beam Mass Spectrometry (Py-MBMS). Stems were harvested, debarked, dried, milled, destarched and ethanol extracted prior to analysis. Py-MBMS analysis was conducted using approximately 4 mg of wood from biomass and each sample was analyzed in duplicate. A Frontier PY2020 unit pyrolyzed samples at 500°C for 30 s in 80 µL deactivated stainless steel cups. An Extrel Super-Sonic MBMS Model Max 1000 was used to collect mass spectral data fromm/z30 to 450 at 17 eV and processed using Merlin Automation software (V3). Spectral ion intensities were normalized to the total ion chromatogram signal for each sample for analysis of spectral variance. Lignin content (wt %) was estimated based on relative responses from standards of known Klason lignin content using mean-normalized ion intensities ofm/z120, 124 (G), 137 (G), 138 (G), 150 (G), 152, 154 (S), 164 (G), 167 (S), 168 (S), 178 (G), 180, 181, 182 (S), 194 (S), 208 (S) and 210 (S) where G indicates guaiacyl-derived ions, S indicates syringyl-derived ions, and other ions either derive from other lignin monomers or multiple sources. Ratios of S and G lignin monomer units (S/G) were obtained by dividing the sum of S-based ions by the sum of G-based ions using mean-normalized ion intensities.

CBI↗

Amorphization kinetics in strontium titanate at 16 and 300 K under argon ion irradiation

Here, the accumulation of irradiation-induced disorder in SrTiO 3 single crystals irradiated at 16 K with 200 keV Ar ions has been investigated using Rutherford backscattering spectrometry along the < 100 > channeling direction and compared with previous results obtained at 300 K under identical irradiation conditions. As expected, amorphization at 16 K occurs at a much lower fluence than at 300 K due to dynamic recovery of irradiation-induced defects at 300 K. Utilizing a comprehensive damage accumulation model for analysis of the data, irradiation at 16 K results only in the formation of point defects and amorphous pockets, while defect clusters are also formed at 300 K. High defect mobility under irradiation at 300 K tends to promote recombination and clustering of point defects. These results suggest that defect diffusion processes in SrTiO 3 are not thermally active at 16 K.

36 MATERIALS SCIENCE↗

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Characterization of Two Extraordinary AmLi Neutron Sources

Two legacy AmLi sources, MRC-101 and MRC-103, are routinely used for neutron detector characterization and testing campaigns that Pacific Northwest National Laboratory manages for the Defense Threat Reduction Agency within the U.S. Department of Defense. However, applicability of source measurement data has been substantially limited due to the lack of original manufacturer documentation and cross comparison to other sources. This paper summarizes results of the measurement campaign conducted to better quantify source radionuclide content, neutron energy spectrum and emission rate of the AmLi sources. The source characterization study consisted of three major consecutive measurement exercises. First, gamma spectrometry measurements using a high purity germanium detector were used to estimate the radionuclide content and potential impurities of the AmLi sources. Then neutron spectral measurements were taken to determine the unique neutron energy distribution. Finally, assessments of the total neutron yields of the sources were made with measurements in a neutron well counter. The neutron detection efficiency for these measurements was determined via detailed Monte Carlo modeling based on the neutron energy distribution measured with the rotating neutron spectrometer. The most exciting and unexpected finding of the study was a significant contamination of the source material with beryllium, contributing up to 17% to the total neutron emission rate and correspondingly changing the neutron energy spectrum. Also, the obtained lithium-only portion of the measured energy distribution of the sources was compared against several AmLi spectra previously reported by different researchers.

AWCC, AmLi, beryllium contamination, neutron spect↗

Identification of a DYRK1A-mediated phosphorylation site within the nuclear localization sequence of the hedgehog transcription factor GLI1

GLI1 is a key downstream transcription effector of the Hedgehog (Hh) signaling pathway that is involved in promoting cell growth, differentiation and tissue patterning in embryonic development. GLI1 over-activation and its nuclear localization has also been linked to the increased aggressiveness of a number of cancers. It has previously been demonstrated that DYRK1A (dual-specificity tyrosine-regulated kinase 1A) can phosphorylate GLI1 and promote GLI1 nuclear localization and its transcriptional activity. Utilizing recombinant human GLI1 and DYRK1A proteins and phospho-peptide mass spectrometry, we demonstrated that GLI1 is phosphorylated by DYRK1A at Ser408, a phospho-site that falls within the putative nuclear localization sequence (NLS) of GLI1, suggesting a possible mechanistic role in modulating its translocation. Further, we showed that the Ser408 site on GLI1 was not phosphorylated in the presence of the selective DYRK1A inhibitor harmine. The data described herein provide the first identification of a DYRK1A-mediated site of phosphorylation on GLI1 within its NLS and may serve as a valuable mechanism for further understanding Hh signaling modulation. - Highlights: • We describe a novel direct DYRK1A phosphorylation site on GLI1 at Ser408. • Harmine a selective DYRK1A inhibitor, blocks DYRK1A-mediated GLI1 phosphorylation. • The Ser408 phospho-site is within the GLI1 nuclear localization sequence (380–420). • This phosphorylation site provides a potential anti-Hh therapeutic target.

60 APPLIED LIFE SCIENCES↗

A further experimental and modeling study of acetaldehyde combustion kinetics

Acetaldehyde is an important intermediate and a toxic emission in the combustion of fuels, especially for biofuels. To better understand its combustion characteristics, a detailed chemical kinetic model describing the oxidation of acetaldehyde has been developed and comprehensively validated against various types of literature data including laminar flame speeds, oxidation and pyrolysis in shock tubes, chemical structure of premixed flames, and low-temperature oxidation in jet-stirred reactors. To extend the validation range, the chemical structure of a counterflow flame fueled by acetaldehyde at 600 Torr has been measured using vacuum ultra-violet photoionization molecular-beam mass spectrometry. In addition, ignition delay times at 10 atm and 700-1100 K were measured in a rapid compression machine, and a negative temperature coefficient (NTC) behavior was observed. Here, the present kinetic model well reproduces the results of various acetaldehyde combustion experiments covering wide ranges of temperatures (300–2300 K) and pressures (0.02–10 atm), and explains well the observed NTC behavior based on the competition between multiple oxidation pathways for the methyl radicals and their self-recombination forming ethane, a relatively stable species at temperatures below 1000 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Widespread platinum anomaly documented at the Younger Dryas onset in North American sedimentary sequences

Previously, a large platinum (Pt) anomaly was reported in the Greenland ice sheet at the Younger Dryas boundary (YDB) (12,800 Cal B.P.). In order to evaluate its geographic extent, fire-assay and inductively coupled plasma mass spectrometry (FA and ICP-MS) elemental analyses were performed on 11 widely separated archaeological bulk sedimentary sequences. We document discovery of a distinct Pt anomaly spread widely across North America and dating to the Younger Dryas (YD) onset. The apparent synchroneity of this widespread YDB Pt anomaly is consistent with Greenland Ice Sheet Project 2 (GISP2) data that indicated atmospheric input of platinum-rich dust. We expect the Pt anomaly to serve as a widely-distributed time marker horizon (datum) for identification and correlation of the onset of the YD climatic episode at 12,800 Cal B.P. This Pt datum will facilitate the dating and correlating of archaeological, paleontological, and paleoenvironmental data between sequences, especially those with limited age control.

54 ENVIRONMENTAL SCIENCES↗

Auger decay of 3p-ionized krypton

A theoretical study of Auger cascades during the decay of 3p{sub 1/2} and 3p{sub 3/2} vacancies in krypton has been performed by level-by-level calculations using a wide configuration interaction basis. Auger spectra for all steps of the cascades are presented and are compared with the existing experimental data. Good agreement of our results with the branching ratios of ions measured by a coincidence technique is obtained.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nanocrystalline SiC and Ti 3 SiC 2 Alloys for Reactor Materials: Diffusion of Fission Product Surrogates

MAX phases, such as titanium silicon carbide (Ti 3 SiC 2 ), have a unique combination of both metallic and ceramic properties, which make them attractive for potential nuclear applications. Ti 3 SiC 2 has been suggested in the literature as a possible fuel cladding material. Prior to the application, it is necessary to investigate diffusivities of fission products in the ternary compound at elevated temperatures. This study attempts to obtain relevant data and make an initial assessment for Ti 3 SiC 2 . Ion implantation was used to introduce fission product surrogates (Ag and Cs) and a noble metal (Au) in Ti 3 SiC 2 , SiC, and a dual-phase nanocomposite of Ti 3 SiC 2 /SiC synthesized at PNNL. Thermal annealing and in-situ Rutherford backscattering spectrometry (RBS) were employed to study the diffusivity of the various implanted species in the materials. In-situ RBS study of Ti 3 SiC 2 implanted with Au ions at various temperatures was also performed. The experimental results indicate that the implanted Ag in SiC is immobile up to the highest temperature (1273 K) applied in this study; in contrast, significant out-diffusion of both Ag and Au in MAX phase Ti 3 SiC 2 occurs during ion implantation at 873 K. Cs in Ti 3 SiC 2 is found to diffuse during post-irradiation annealing at 973 K, and noticeable Cs release from the sample is observed. This study may suggest caution in using Ti 3 SiC 2 as a fuel cladding material for advanced nuclear reactors operating at very high temperatures. Further studies of the related materials are recommended.

36 MATERIALS SCIENCE↗

Development of a quadrupole-based Secondary-Ion Mass Spectrometry (SIMS) system at Lewis Research Center

The design, construction, and initial use of an ion microprobe to carry out secondary ion mass spectrometry (SIMS) of solid samples is reported. The system is composed of a differentially pumped custom-made UHV (Ultra High Vacuum) chamber, a quadrupole mass spectrometer and a telefocus A-DIDA ion gun with the capability of producing beams of Cesium, as well as inert and reactive gases. The computer control and acquisition of the data were designed and implemented using a personal computer with plug-in boards, and external circuitry built as required to suit the system needs. The software is being developed by using a FORTH-like language. Initial tests aimed at characterizing the system, as well as preliminary surface and depth-profiling studies are presently underway.

Vargas-Aburto, Carlos↗

NASA Tech Briefs, April 2013

Topics covered include: Fully Integrated, Miniature, High-Frequency Flow Probe Utilizing MEMS Leadless SOI Technology; Nanoscale Surface Plasmonics Sensor With Nanofluidic Control; Advanced Dispersed Fringe Sensing Algorithm for Coarse Phasing Segmented Mirror Telescopes; Neural Network Back-Propagation Algorithm for Sensing Hypergols; Bulk Moisture and Salinity Sensor; Change-Based Satellite Monitoring Using Broad Coverage and Targetable Sensing; Circularly Polarized Microwave Antenna Element with Very Low Off-Axis Cross-Polarization; Ultra-Low Heat-Leak, High-Temperature Superconducting Current Leads for Space Applications; Flash Cracking Reactor for Waste Plastic Processing; An Automated Safe-to-Mate (ASTM) Tester; Wireless Chalcogenide Nanoionic-Based Radio-Frequency Switch; Compute Element and Interface Box for the Hazard Detection System; DOT Transmit Module; Composite Aerogel Multifoil Protective Shielding; Li-Ion Electrolytes with Improved Safety and Tolerance to High-Voltage Systems; Polymer-Reinforced, Non-Brittle, Lightweight Cryogenic Insulation; Controlled, Site-Specific Functionalization of Carbon Nanotubes with Diazonium Salts; Regenerable Sorbent for CO2 Removal; Sprayable Aerogel Bead Compositions With High Shear Flow Resistance and High Thermal Insulation Value; Lexan Linear Shaped Charge Holder with Magnets and Backing Plate; Robotic Ankle for Omnidirectional Rock Anchors; Wind, Wave, and Tidal Energy Without Power Conditioning; An Active Heater Control Concept to Meet IXO Type Mirror Module Thermal-Structural Distortion Requirement; Waterless Clothes-Cleaning Machine; Integrated Electrical Wire Insulation Repair System; LVGEMS Time-of-Flight Mass Spectrometry on Satellites; Surface Inspection Tool for Optical Detection of Surface Defects; Per-Pixel, Dual-Counter Scheme for Optical Communications; Certification-Based Process Analysis; Surface Navigation Using Optimized Waypoints and Particle Swarm Optimization; Smart-Divert Powered Descent Guidance to Avoid the Backshell Landing Dispersion Ellipse; Estimating Foreign-Object-Debris Density from Photogrammetry Data; Adaptive Sampling of Spatiotemporal Phenomena with Optimization Criteria; Building a 2.5D Digital Elevation Model From 2D Imagery; Eyes on the Earth 3D; Target Trailing With Safe Navigation for Maritime Autonomous Surface Vehicles; Adams-Based Rover Terramechanics and Mobility Simulator - ARTEMIS; ISTP CDF Skeleton Editor; Uplink Summary Generator (ULSGEN) Version 1.0; Robotics On-Board Trainer (ROBoT); Software Engineering Tools for Scientific Models; Automatic Data Filter Customization Using a Genetic Algorithm; Tracker Toolkit; Towards Efficient Scientific Data Management Using Cloud Storage; On a Formal Tool for Reasoning About Flight Software Cost Analysis; A Nanostructured Composites Thermal Switch Controls Internal and External Short Circuit in Lithium Ion Batteries; Spacecraft Crew Cabin Condensation Control; and Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex.

Source record↗

Quantification of absorption, retention and elimination of two different oral doses of vitamin A in Zambian boys using accelerator mass spectrometry

A recent survey indicated that high-dose vitamin A supplements (HD-VAS) had no apparent effect on vitamin A (VA) status of Zambian children <5 y of age. To explore possible reasons for the lack of response to HD-VAS among Zambian children, we quantified the absorption, retention, and urinary elimination of either a single HDVAS (60 mg) or a smaller dose of stable isotope (SI)-labeled VA (5 mg), which was used to estimate VA pool size, in 3-4 y old Zambian boys (n = 4 for each VA dose). A 25 nCi tracer dose of [{sup 14}C{sub 2}]-labeled VA was co-administered with the HD-VAS or SI-labeled VA, and 24-hr stool and urine samples were collected for 3 and 7 consecutive days, respectively, and 24-hr urine samples at 4 later time points. Accelerator Mass Spectrometry (AMS) was used to measure the cumulative excretion of {sup 14}C in stool and urine 3d after dosing to estimate, respectively, absorption and retention of the VAS and SI-labeled VA. The urinary elimination rate (UER) was estimated by plotting {sup 14}C in urine vs. time, and fitting an exponential equation to the data. Estimates of mean absorption, retention and the UER were 83.8 {+-} 7.1%, 76.3 {+-} 6.7%, and 1.9 {+-} 0.6%/d, respectively, for the HD-VAS and 76.5 {+-} 9.5%, 71.1 {+-} 9.4%, and 1.8 {+-} 1.2%/d, respectively for the smaller dose of SI-labeled VA. Estimates of absorption, retention and the UER did not differ by size of the VA dose administered (P=0.26, 0.40, 0.88, respectively). Estimated absorption and retention were negatively associated with reported fever (P=0.011) and malaria (P =0.010). HD-VAS and SI-labeled VA were adequately absorbed, retained and utilized in apparently healthy Zambian preschool-age boys, although absorption and retention may be affected by recent infections.

59 BASIC BIOLOGICAL SCIENCES↗

Benzo[a]pyrene (BaP) metabolites predominant in human plasma following escalating oral micro-dosing with [ 14 C]-BaP

Benzo[a]pyrene (BaP) is formed by incomplete combustion of organic materials (petroleum, coal, tobacco, etc.). BaP is designated by the International Agency for Research on Cancer as a group 1 known human carcinogen; a classification supported by numerous studies in preclinical models and epidemiology studies of exposed populations. Risk assessment relies on toxicokinetic and cancer studies in rodents at doses 5–6 orders of magnitude greater than average human uptake. Using a dose–response design at environmentally relevant concentrations, this study follows uptake, metabolism, and elimination of [ 14 C]-BaP in human plasma by employing UPLC - accelerator mass spectrometry (UPLC-AMS). Volunteers were administered 25, 50, 100, and 250 ng (2.7–27 nCi) of [ 14 C]-BaP (with interceding minimum 3-week washout periods) with quantification of parent [ 14 C]-BaP and metabolites in plasma measured over 48 h. [ 14 C]-BaP median T max was 30 min with C max and area under the curve (AUC) approximating dose-dependency. Marked inter-individual variability in plasma pharmacokinetics following a 250 ng dose was seen with 7 volunteers as measured by the C max (8.99 ± 7.08 ng × mL -1 ) and AUC0-48hr (68.6 ± 64.0 fg × hr -1 × mL -1 ). Approximately 3–6% of the [ 14 C] recovered (AUC 0-48 hr ) was parent compound, demonstrating extensive metabolism following oral dosing. Metabolite profiles showed that, even at the earliest time-point (30 min), a substantial percentage of [ 14 C] in plasma was polar BaP metabolites. The best fit modeling approach identified non-compartmental apparent volume of distribution of BaP as significantly increasing as a function of dose (p = 0.004). Bay region tetrols and dihydrodiols predominated, suggesting not only was there extensive first pass metabolism but also potentially bioactivation. AMS enables the study of environmental carcinogens in humans with de minimus risk, allowing for important testing and validation of physiologically based pharmacokinetic models derived from animal data, risk assessment, and the interpretation of data from high-risk occupationally exposed populations.

59 BASIC BIOLOGICAL SCIENCES↗

Solvent effects on differentiation of mouse brain tissue using laser microdissection ‘cut and drop’ sampling with direct mass spectral analysis

Rationale: Laser microdissection-liquid vortex capture/electrospray ionization mass spectrometry (LMD-LVC/ESI-MS) has potential for on-line classification of tissue but an investigation into what analytical conditions provide best spectral differentiation has not been conducted. The effects of solvent, ionization polarity, and spectral acquisition parameters on differentiation of mouse brain tissue regions are described.Methods: Individual 40 × 40 μm microdissections from cortex, white, grey, granular, and nucleus regions of mouse brain tissue were analyzed using different capture/ESI solvents, in positive and negative ion mode ESI, using time-of-flight (TOF)-MS and sequential window acquisitions of all theoretical spectra (SWATH)-MS (a permutation of tandem-MS), and combinations thereof. Principal component analysis-linear discriminant analysis (PCA-LDA), applied to each mass spectral dataset, was used to determine the accuracy of differentiation of mouse brain tissue regions. Results: Mass spectral differences associated with capture/ESI solvent composition manifested as altered relative distributions of ions rather than the presence or absence of unique ions. In negative ion mode ESI, 80/20 (v/v) methanol/water yielded spectra with low signal/noise ratios relative to other solvents. PCA-LDA models acquired using 90/10 (v/v) methanol/chloroform differentiated tissue regions with 100% accuracy while data collected using methanol misclassified some samples. The combination of SWATH-MS and TOF-MS data improved differentiation accuracy.Conclusions: Combined TOF-MS and SWATH-MS data differentiated white, grey, granular, and nucleus mouse tissue regions with greater accuracy than when solely using TOF-MS data. Using 90/10 (v/v) methanol/chloroform, tissue regions were perfectly differentiated. Lastly, these results will guide future studies looking to utilize the potential of LMD-LVC/ESI-MS for tissue and disease differentiation.

47 OTHER INSTRUMENTATION↗