Self-Repairing Fatigue Damage in Metallic Structures for Aerospace Vehicles Using Shape Memory Alloy Self-healing (SMASH) Technology

This DAA is for the Phase II webinar presentation of the ARMD-funded SMASH technology. A self-repairing aluminum-based composite system has been developed using liquid-assisted healing theory in conjunction with the shape memory effect of wire reinforcements. The metal matrix composite was thermodynamically designed to have a matrix with a relatively even dispersion of low-melting phase, allowing for repair of cracks at a pre-determined temperature. Shape memory alloy wire reinforcements were used within the composite to provide crack closure. Investigators focused the research on fatigue cracks propagating through the matrix in order to optimize and computer model the SMASH technology for aeronautical applications.

fatigue↗

TU-H-BRA-04: A Novel Superconducting Magnet Design for Optimized Patient Access and Minimal SSD for Use in a Linac-MR Hybrid

Purpose: A prototype rotating hybrid MR imaging system and linac has been developed to allow for simultaneous imaging and radiation delivery parallel to B{sub 0}. However, the design of a compact magnet capable of rotation in a small vault with sufficient patient access and a typical clinical source-to-surface distance (SSD) is challenging. This work presents a novel superconducting magnet design that allows for a reduced SSD and ample patient access by moving the superconducting coils to the side of the yoke. The yoke and pole-plate structures are shaped to direct the magnetic flux appropriately. Methods: The surface of the pole plate for the magnet assembly is optimized. The magnetic field calculations required in this work are performed with the 3D finite element method software package Opera-3D. Each tentative design strategy is virtually modeled in this software package and externally controlled by MATLAB, with its key geometries defined as variables. The particle swarm optimization algorithm is used to optimize the variables subject to the minimization of a cost function. At each iteration, Opera-3D will solve the magnetic field solution over a field-of-view suitable for MR imaging and the degree of field uniformity will be assessed to calculate the value of the cost function associated with that iteration. Results: An optimized magnet assembly that generates a homogenous 0.2T magnetic field over an ellipsoid with large axis of 30 cm and small axes of 20 cm is obtained. Conclusion: The distinct features of this model are the minimal distance between the yoke’s top and the isocentre and the improved patient access. On the other hand, having homogeneity over an ellipsoid give us a larger field-of-view, essential for geometric accuracy of the MRI system. The increase of B{sub 0} from 0.2T in the present model to 0.5T is the subject of future work. Funding Sources: Alberta Innovates - Health Solutions (AIHS)| Disclosure and Conflict of Interest: B. Gino Fallone is a co-founder and CEO of MagnetTx Oncology Solutions (under discussions to license Alberta biplanar linac MR for commercialization).

60 APPLIED LIFE SCIENCES↗

Stress transfer during different deformation stages in a nano-precipitate-strengthened Ni-Ti shape memory alloy

Understanding the role of fine coherent precipitates in the micromechanical behavior of precipitate-strengthened shape memory alloys (SMAs), which still remains a mystery heretofore, is of crucial importance to the design of advanced SMAs with optimal functional and mechanical properties. Here, we investigate the lattice strain evolution of, and the stress partition between the nanoscale Ni{sub 4}Ti{sub 3} precipitates and the matrix in a precipitate-strengthened Ni-Ti SMA during different deformation stages by in-situ synchrotron high-energy X-ray diffraction technique. We found that, during R-phase reorientation and stress-induced martensitic transformation, which both involve the shear deformation process, the lattice strain of the nanoscale precipitates drastically increases by a magnitude of 0.5%, which corresponds to an abrupt increase of ∼520 MPa in internal stress. This indicates that stress repartition occurs and most of the stress is transferred to the precipitates during the shear deformation of the matrix. It is further revealed that the nanoscale precipitates which only have a low volume fraction bear a considerable amount of applied stress during all deformation stages investigated, implying that the nanoscale precipitates play an important role in the deformation behavior of the precipitate-strengthened Ni-Ti SMAs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DEVELOPMENT OF INEXPENSIVE HIGH TEMPERATURE NITI-BASED SHAPE MEMORY ALLOYS FOR POWDER BED ADDITIVE MANUFACTURING

NiTi and NiTi-based Shape Memory Alloys (SMA) exhibit a reversible solid-state phase transformation from martensite to austenite driven by thermal energy. High temperature (Mf>100°C) SMAs are martensite at room temperature and can be fabricated into solid-state actuators that return to a pre-programmed shape against a designed load after heating to transformation threshold. Reactive as-fabricated additively manufactured parts (4-D printing) is the current state of the art in manufacturing of SMAs but requires compositions compliant to rapid solidification. Existing actuator designs are developed from commercially available, highly investigated material compositions. However, existing high temperature high performance (high actuation strain, low thermal hysteresis) shape memory alloys contain significant (>10% at.) portions of high-cost Platinum Group Metals (PGMs). It is of significant scientific interest to investigate material compositions that are peer performing or superior to PGMs whose constituent elements represent a significant cost savings. Shape memory alloy properties vary significantly with small (0.1% at.) compositional changes making robust investigative sample sets very large. Computational material design can be deployed to shrink the compositional space of possible alloy combinations and reduce the experimental load in material discovery. Investigating shape memory effect (SME) and validating process additive process parameters for a single novel composition is cost intensive in both time and consumed materials. Additionally, sub-optimal processing, oxygen, or solidification rate sensitivity could render additively manufacturing specimens without micro, macro cracks, or significant chemical variance impossible. Unfortunately, such failure susceptibility cannot be simulated. Therefore, a research pathway to validate novel shape memory alloy compositions for powder bed fusion additive manufacturing without the need for powdered feedstock is also proposed. This research investigates novel high temperature shape memory alloys for actuators without platinum group alloying elements to discover one that could be commercially viable as an additive manufacturing feedstock.

Sundermann, Tayler↗

Compressible degree of freedom (CDOF): A potential strategy for improving wave energy capture

The addition of a compressible degree of freedom (CDOF) has been shown to significantly increase the power absorption compared to a traditional rigid WEC of the same shape and mass for a variety of architectures. The present study demonstrates that a compressible point absorber, with a passive power-take-off (PTO) and optimized damping, can also achieve at the same performance levels or better than an optimally controlled rigid point absorber using reactive power from the PTO. Eliminating the need for a reactive PTO would substantially reduce costs by reducing PTO design complexity. In addition, it would negate the documented problems of reactive PTO efficiencies on absorbed power. Improvements to performance were quantified in the present study by comparing a compressible point absorber to a conventional rigid one with the same shape and mass. Wave energy is converted to mechanical energy in both cases using a linear damper PTO, with the PTO coefficient optimized for each resonance frequency and compressible volume. The large compressible volumes required to tune the compressible point absorber to the desired frequency are a practical limitation that needs to be addressed with further research; especially for low frequencies. If fact, all compressible volumes exceed the submerged volume of the point absorber by significant amounts; requiring auxiliary compressible volume storage units that are connected to the air chamber in the submerged portion of the point absorber. While realistic, these auxiliary units would increase the Cap Ex and Op Ex costs, potentially reducing the aforementioned benefits gained by CDOF. However, alternative approaches can be developed to implement CDOF without the large compressible volume requirements, including the development of flexible surface panels tuned with mechanical springs.

42 ENGINEERING↗

Optimization of Neutron Spectrum in Northwest Beam Tube of Tehran Research Reactor for BNCT, by MCNP Code

In order to gain the neutron spectrum with proper components specification for BNCT, it is necessary to design a Beam Shape Assembling (BSA), include of moderator, collimator, reflector, gamma filter and thermal neutrons filter, in front of the initial radiation beam from the source. According to the result of MCNP4C simulation, the Northwest beam tube has the most optimized neuron flux between three north beam tubes of Tehran Research Reactor (TRR). So, it has been chosen for this purpose. Simulation of the BSA has been done in four above mentioned phases. In each stage, ten best configurations of materials with different length and width were selected as the candidates for the next stage. The last BSA configuration includes of: 78 centimeters of air as an empty space, 40 centimeters of Iron plus 52 centimeters of heavy-water as moderator, 30 centimeters of water or 90 centimeters of Aluminum-Oxide as a reflector, 1 millimeters of lithium (Li) as thermal neutrons filter and finally 3 millimeters of Bismuth (Bi) as a filter of gamma radiation. The result of Calculations shows that if we use this BSA configuration for TRR Northwest beam tube, then the best neutron flux and spectrum will be achieved for BNCT. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of prechamber enabled mixing-controlled combustion strategy for ultra-low methane emissions from lean burn natural gas engines

This numerical study explores the optimization of Prechamber Enabled Mixing-Controlled Combustion (PC-MCC) using natural gas in heavy-duty engines, aiming to enhance combustion efficiency to minimize methane slip and NOx emissions. The approach involves a prechamber ignition system, distinct from conventional spark ignition (SI) systems, to initiate combustion of direct injected natural gas. By leveraging the robust ignition characteristics of the prechamber, the PC-MCC method demonstrates significant potential in achieving efficient combustion akin to diesel engines but with lower greenhouse gas emissions. The research evaluates the effects of various geometric and operational parameters on the combustion process and emissions, including prechamber volume, nozzle diameter, direct injector (DI) geometry, and engine operating strategies. Computational Fluid Dynamics (CFD) simulations are utilized, focusing on a heavy-duty, single-cylinder engine modeled after the Caterpillar C9.3B engine. Key findings indicate that a prechamber volume of 3 cc, coupled with a nozzle diameter of 2.75 mm for two prechamber holes, strikes an optimal balance between combustion efficiency and emissions reduction. This configuration ensures robust combustion across a range of operating conditions while maintaining methane slip within targeted limits. Further investigation into DI geometry shows the significance of the injector umbrella angle and nozzle diameter in shaping the fuel-air mixing and combustion dynamics. An umbrella angle of 130° and a nozzle diameter of 300 microns are identified as optimal, promoting rapid and efficient combustion with minimized methane and NOx emissions. The study also investigates the impact of injection timing and pressure, highlighting their roles in controlling combustion timing and influencing emissions levels. Advanced injection timing is found to be crucial in achieving the desired low methane slip, whereas retarded injection timing assists to reduce NOx emissions while having a slight increase in methane emissions. Operating strategies incorporating various levels of Exhaust Gas Recirculation (EGR) are assessed for their effectiveness in further reducing emissions. The research demonstrates that a judicious combination of internal hot EGR and careful calibration of DI pressure and SOI timing can achieve significant reductions in NOx emissions while keeping methane slip under control. Specifically, an internal EGR level of 15%–25%, combined with DI pressures of 200–300 bar and injection timings at or after top dead center, is recommended. These findings contribute valuable insights into the development of advanced combustion techniques for natural gas engines, offering a viable pathway to reduce methane slip without compromising engine efficiency or performance. The PC-MCC system presents a promising solution for the future of heavy-duty natural gas engine technology to reduce methane emissions.

Nsaif, Osama↗

Ames Optimized TCA Configuration

Configuration design at Ames was carried out with the SYN87-SB (single block) Euler code using a 193 x 49 x 65 C-H grid. The Euler solver is coupled to the constrained (NPSOL) and the unconstrained (QNMDIF) optimization packages. Since the single block grid is able to model only wing-body configurations, the nacelle/diverter effects were included in the optimization process by SYN87's option to superimpose the nacelle/diverter interference pressures on the wing. These interference pressures were calculated using the AIRPLANE code. AIRPLANE is an Euler solver that uses a unstructured tetrahedral mesh and is capable of computations about arbitrary complete configurations. In addition, the buoyancy effects of the nacelle/diverters were also included in the design process by imposing the pressure field obtained during the design process onto the triangulated surfaces of the nacelle/diverter mesh generated by AIRPLANE. The interference pressures and nacelle buoyancy effects are added to the final forces after each flow field calculation. Full details of the (recently enhanced) ghost nacelle capability are given in a related talk. The pseudo nacelle corrections were greatly improved during this design cycle. During the Ref H and Cycle 1 design activities, the nacelles were only translated and pitched. In the cycle 2 design effort the nacelles can translate vertically, and pitch to accommodate the changes in the lower surface geometry. The diverter heights (between their leading and trailing edges) were modified during design as the shape of the lower wing changed, with the drag of the diverter changing accordingly. Both adjoint and finite difference gradients were used during optimization. The adjoint-based gradients were found to give good direction in the design space for configurations near the starting point, but as the design approached a minimum, the finite difference gradients were found to be more accurate. Use of finite difference gradients was limited by the CPU time limit available on the Cray machines. A typical optimization run using finite difference gradients can use only 30 to 40 design variables and one optimization iteration within the 8 hour queue limit for the chosen grid size and convergence level. The efficiency afforded by the adjoint method allowed for 50-120 design variables and 5-10 optimization iterations in the 8 hour queue. Geometric perturbations to the wing and fuselage were made using the Hicks/Henne (HH) shape functions. The HH functions were distributed uniformly along the chords of the wing defining sections and lofted linearly. During single-surface design, constraints on thickness and volume at selected wing stations were imposed. Both fuselage camber and cross-sectional area distributions were permitted to change during design. The major disadvantage to the use of these functions is the inherent surface waviness produced by repeated use of such functions. Many smoothing operations were required following optimization runs to produce a configuration with reasonable smoothness. Wagner functions were also used on the wing sections but were never used on the fuselage. The Wagner functions are a family of increasingly oscillatory functions that have also been used extensively in airfoil design. The leading and trailing edge regions of the wing were designed by use of polynomial and monomial functions respectively. Twist was attempted but was abandoned because of little performance improvement available from changing the baseline twist.

Cliff, Susan E.↗

Optimal beam margins in linac-based VMAT stereotactic ablative body radiotherapy: a Pareto front analysis for liver metastases

We explored the Pareto fronts mathematical strategy to determine the optimal block margin and prescription isodose for stereotactic body radiotherapy (SBRT) treatments of liver metastases using the volumetric-modulated arc therapy (VMAT) technique. Three targets (planning target volumes [PTVs] = 20, 55, and 101 cc) were selected. A single fraction dose of 26 Gy was prescribed (prescription dose [PD]). VMAT plans were generated for 3 different beam energies. Pareto fronts based on (1) different multileaf collimator (MLC) block margin around PTV and (2) different prescription isodose lines (IDL) were produced. For each block margin, the greatest IDL fulfilling the criteria (95% of PTV reached 100%) was considered as providing the optimal clinical plan for PTV coverage. Liver D{sub mean}, V7Gy, and V12Gy were used against the PTV coverage to generate the fronts. Gradient indexes (GI and mGI), homogeneity index (HI), and healthy liver irradiation in terms of D{sub mean}, V7Gy, and V12Gy were calculated to compare different plans. In addition, each target was also optimized with a full-inverse planning engine to obtain a direct comparison with anatomy-based treatment planning system (TPS) results. About 900 plans were calculated to generate the fronts. GI and mGI show a U-shaped behavior as a function of beam margin with minimal values obtained with a +1 mm MLC margin. For these plans, the IDL ranges from 74% to 86%. GI and mGI show also a V-shaped behavior with respect to HI index, with minimum values at 1 mm for all metrics, independent of tumor dimensions and beam energy. Full-inversed optimized plans reported worse results with respect to Pareto plans. In conclusion, Pareto fronts provide a rigorous strategy to choose clinical optimal plans in SBRT treatments. We show that a 1-mm MLC block margin provides the best results with regard to healthy liver tissue irradiation and steepness of dose fallout.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the flow imbalance on the profile shape during the extrusion of thin magnesium sheets

The extrusion process facilitates the production of magnesium sheets featuring a very thin thickness as well as excellent surface properties by using a single process step only. However, the extrusion of the magnesium sheets applying not optimized process parameters, e.g. low billet temperature or/ and poorly deformable magnesium alloy, produce pronounced buckling and waving of the extruded sheets as well as a variation of accuracy in profile shape along the cross section. The present investigation focuses on the FEM-simulation of the extrusion of magnesium sheets in order to clarify the origin of the mentioned effects. The simulations identify the flow imbalance during extrusion as the main critical factor. Due to the flow imbalance after passing the die a large compression stress zone is formed causing the buckling and waving of the thin sheets. Furthermore, the simulations of the magnesium sheet extrusion reveal that the interaction of the material flow gradients along the width and along the thickness direction near the die orifice lead to the variation of the accuracy in profile shape.

36 MATERIALS SCIENCE↗

The ANACONDA algorithm for deformable image registration in radiotherapy

Purpose: The purpose of this work was to describe a versatile algorithm for deformable image registration with applications in radiotherapy and to validate it on thoracic 4DCT data as well as CT/cone beam CT (CBCT) data. Methods: ANAtomically CONstrained Deformation Algorithm (ANACONDA) combines image information (i.e., intensities) with anatomical information as provided by contoured image sets. The registration problem is formulated as a nonlinear optimization problem and solved with an in-house developed solver, tailored to this problem. The objective function, which is minimized during optimization, is a linear combination of four nonlinear terms: 1. image similarity term; 2. grid regularization term, which aims at keeping the deformed image grid smooth and invertible; 3. a shape based regularization term which works to keep the deformation anatomically reasonable when regions of interest are present in the reference image; and 4. a penalty term which is added to the optimization problem when controlling structures are used, aimed at deforming the selected structure in the reference image to the corresponding structure in the target image. Results: To validate ANACONDA, the authors have used 16 publically available thoracic 4DCT data sets for which target registration errors from several algorithms have been reported in the literature. On average for the 16 data sets, the target registration error is 1.17 ± 0.87 mm, Dice similarity coefficient is 0.98 for the two lungs, and image similarity, measured by the correlation coefficient, is 0.95. The authors have also validated ANACONDA using two pelvic cases and one head and neck case with planning CT and daily acquired CBCT. Each image has been contoured by a physician (radiation oncologist) or experienced radiation therapist. The results are an improvement with respect to rigid registration. However, for the head and neck case, the sample set is too small to show statistical significance. Conclusions: ANACONDA performs well in comparison with other algorithms. By including CT/CBCT data in the validation, the various aspects of the algorithm such as its ability to handle different modalities, large deformations, and air pockets are shown.

60 APPLIED LIFE SCIENCES↗

Virtual Deformation Control of the X-56A Model with Simulated Fiber Optic Sensors

A robust control law design methodology is presented to stabilize the X-56A model and command its wing shape. The X-56A was purposely designed to experience flutter modes in its flight envelope. The methodology introduces three phases: the controller design phase, the modal filter design phase, and the reference signal design phase. A mu-optimal controller is designed and made robust to speed and parameter variations. A conversion technique is presented for generating sensor strain modes from sensor deformation mode shapes. The sensor modes are utilized for modal filtering and simulating fiber optic sensors for feedback to the controller. To generate appropriate virtual deformation reference signals, rigid-body corrections are introduced to the deformation mode shapes. After successful completion of the phases, virtual deformation control is demonstrated. The wing is deformed and it is shown that angle-ofattack changes occur which could potentially be used to an advantage. The X-56A program must demonstrate active flutter suppression. It is shown that the virtual deformation controller can achieve active flutter suppression on the X-56A simulation model.

Suh, Peter M.↗

Virtual Deformation Control of the X-56A Model with Simulated Fiber Optic Sensors

A robust control law design methodology is presented to stabilize the X-56A model and command its wing shape. The X-56A was purposely designed to experience flutter modes in its flight envelope. The methodology introduces three phases: the controller design phase, the modal filter design phase, and the reference signal design phase. A mu-optimal controller is designed and made robust to speed and parameter variations. A conversion technique is presented for generating sensor strain modes from sensor deformation mode shapes. The sensor modes are utilized for modal filtering and simulating fiber optic sensors for feedback to the controller. To generate appropriate virtual deformation reference signals, rigid-body corrections are introduced to the deformation mode shapes. After successful completion of the phases, virtual deformation control is demonstrated. The wing is deformed and it is shown that angle-of-attack changes occur which could potentially be used to an advantage. The X-56A program must demonstrate active flutter suppression. It is shown that the virtual deformation controller can achieve active flutter suppression on the X-56A simulation model.

Modal Filter↗

The Search for Optimal Visual Stimuli

In 1983, Watson, Barlow and Robson published a brief report in which they explored the relative visibility of targets that varied in size, shape, spatial frequency, speed, and duration (referred to subsequently here as WBR). A novel aspect of that paper was that visibility was quantified in terms of threshold contrast energy, rather than contrast. As they noted, this provides a more direct measure of the efficiency with which various patterns are detected, and may be more edifying as to the underlying detection machinery. For example, under certain simple assumptions, the waveform of the most efficiently detected signal is an estimate of the receptive field of the visual system's most efficient detector. Thus one goal of their experiment Basuto search for the stimulus that the 'eye sees best'. Parenthetically, the search for optimal stimuli may be seen as the most general and sophisticated variant of the traditional 'subthreshold summation' experiment, in which one measures the effect upon visibility of small probes combined with a base stimulus.

Watson, Andrew B.↗

SU-E-T-567: A Three-Field Mono-Isocentric Inverse Treatment Planning Method for the Patients with Larger Breasts

Purpose: The purpose of this study is to develop a three-field monoisocentric inverse breast treatment planning technique without the use of half-beam block. Methods: Conventional three-field breast treatment with supraclavicular half-beam blocked requires two isocenters when the breast is too large to be contained within half-beam. The inferior border of the supraclavicular field and superior borders of the breast fields are matched on patient's skin with the light field. This method causes a large dose variation in the matching region due to daily setup uncertainties and requires a longer treatment setup time. We developed a three-field mono-isocentric planning method for the treatment of larger breasts. The three fields share the same isocenter located in the breast. Beam matching is achieved by rotating collimator, couch and gantry. Furthermore, we employed a mixed open-IMRT inverse optimization method to improve dose uniformity and coverage. Results: Perfect geometric beam matching was achieved by rotating couch, collimator and gantry together. Treatment setup time was significantly reduced without light-field matching during treatment deliveries. Inverse mixed open-IMRT optimization method achieved better dose uniformity and PTV coverage while keeping sufficient air flash to compensate setup and breast shape changes in daily treatments. Conclusion: By eliminating light field matching, the three-field mono-isocentric treatment method can significantly reduce setup time and uncertainty for large breast patients. Plan quality is further improved by inverse IMRT planning.

60 APPLIED LIFE SCIENCES↗

Large breast compressions: Observations and evaluation of simulations

Purpose: Several methods have been proposed to simulate large breast compressions such as those occurring during x-ray mammography. However, the evaluation of these methods against real data is rare. The aim of this study is to learn more about the deformation behavior of breasts and to assess a simulation method. Methods: Magnetic resonance (MR) images of 11 breasts before and after applying a relatively large in vivo compression in the medial direction were acquired. Nonrigid registration was employed to study the deformation behavior. Optimal material properties for finite element modeling were determined and their prediction performance was assessed. The realism of simulated compressions was evaluated by comparing the breast shapes on simulated and real mammograms. Results: Following image registration, 19 breast compressions from 8 women were studied. An anisotropic deformation behavior, with a reduced elongation in the anterior-posterior direction and an increased stretch in the inferior-superior direction was observed. Using finite element simulations, the performance of isotropic and transverse isotropic material models to predict the displacement of internal landmarks was compared. Isotropic materials reduced the mean displacement error of the landmarks from 23.3 to 4.7 mm, on average, after optimizing material properties with respect to breast surface alignment and image similarity. Statistically significantly smaller errors were achieved with transverse isotropic materials (4.1 mm, P=0.0045). Homogeneous material models performed substantially worse (transverse isotropic: 5.5 mm; isotropic: 6.7 mm). Of the parameters varied, the amount of anisotropy had the greatest influence on the results. Optimal material properties varied less when grouped by patient rather than by compression magnitude (mean: 0.72 vs 1.44). Employing these optimal materials for simulating mammograms from ten MR breast images of a different cohort resulted in more realistic breast shapes than when using established material models. Conclusions: Breasts in the prone position exhibited an anisotropic compression behavior. Transverse isotropic materials with an increased stiffness in the anterior-posterior direction improved the prediction of these deformations and produced more realistic mammogram simulations from MR images.

60 APPLIED LIFE SCIENCES↗

Manufacturing Dissolvable Alloy Components using ShAPE: A Study on Solid Phase Processing of Mg-W Composites and WJ11 Alloys

Dissolvable alloys and composites are an emerging class of materials that demonstrate tailored sorptivity in corrosive environments. This work explored the viability of solid phase processing (SPP) techniques, namely the shear assisted processing and extrusion (ShAPETM) method, to manufacture dissolvable magnesium composites and alloys components such as rods and tubes. The study also determined the effects of material composition and manufacturing process conditions on material microstructures developed during SPP and the resulting performance of the components. Explicit properties of interest included ultimate tensile strength, ultimate compressive strength, and yield strength. The application fields of interest for dissolvable alloys were identified as oil-and-gas operations and biomedical implants. Accordingly, PNNL collaborated with industrial and academia partners, Fortek Industries, Houston and University of Pittsburgh, during the course of this project for material and ShAPE process development. PNNL determined the viability of the using ShAPE to process the custom-designed materials provided by the project partners. This was done by identifying process parameters such as tool rotation rate, tool plunge rate, and process cooling optimal for manufacturing components with consolidated microstructures. Subsequently, PNNL also performed microstructural characterization on unprocessed and processed samples and mechanical property testing. One of the major findings from this work is that ShAPE was able to manufacture dissolvable magnesium composite and alloy rods and tubes with consolidated homogeneous microstructures and minimal macroscale defects on component surfaces. It was observed that samples processed via ShAPE demonstrated an average grain size < 2 - 5 µm, which was markedly lower than that of the precursors with 8 – 13 µm grains. Results showed that the ShAPE synthesized dissolvable magnesium composite and alloy strength was on par with or better than those components that were manufactured using traditional manufacturing processes such as forging and extrusion. It is noteworthy that the ShAPE samples were made with considerably lower number of process steps.

36 MATERIALS SCIENCE↗

Design Characteristics to Eliminate the Need for Parameter Optimization in Nanoflow ESI-MS

The sampling efficiency in electrospray ionization-mass spectrometry (ESI-MS) can be improved by decreasing the liquid flow rate to the nanoflow regime, where it is possible to draw a large fraction of the ESI plume into the mass spectrometer. This mode of operation is typically more difficult than ESI-MS at higher flow rates because it requires careful optimization of a number of parameters to achieve optimal sampling efficiency. In this work, we screened the relative impact on signal intensity and spray stability of factors that included sprayer position, spray electrode protrusion, sprayer tip shape, spray angle relative to the MS inlet, nebulizer gas flow rate, ESI potential, and means for generating the electric field to initiate electrospray. Based on the screening results, we explore the possibility of providing fixed optimal values for many of the key source parameters to eliminate much of the tuning that is required for conventional nanoflow sources. This approach has potential to greatly simplify nanoflow ESI-MS, while providing optimized sensitivity, stability, and robustness, with decreased variability between analyses. .