Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quadrupoles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Measurements of emittance at low energy

Ideally, experimental measurements of all beam parameters should be made at the exit of the injector. This has not been possible on DARHT Axis-II for various practical reasons. In particular, the emittance has not been measured there. This note reviews the methods we have used for emittance measurements on the linear induction accelerator (LIA) at low-energy (< 10 MeV). It includes a discussion of some of the issues associated with making those measurements on a beam from the injector. A successful plan for emittance measurements at any energy should incorporate measures to deal with these issues. To begin with, it should be recognized that emittance measurements at the injector are not critical for beam physics in the accelerator. The emittance at the injector has very little effect on accelerator beam dynamics except for an increase in size near the end, where the beam becomes emittance dominated. Therefore, imperfect knowledge has little effect on the design and implementation of a tune. This point is illustrated in Fig. 1, which shows beam envelope calculations for our present tune over a wide range of emittances. Compare this with using the wrong diode voltage in the tune design. Figure 2 shows the effect on the beam envelope of a 2% error in the measurement of diode voltage. Therefore, a few years ago, when we made plans for beam measurements at the diode while we were upgrading the injector cells, our highest priority was on magnetic spectrometer measurements of energy. These measurements were to be used to cross calibrate the diode-voltage monitor, so that accurate diode voltage measurements could be made on every shot after the spectrometer was removed. If emittance measurements at the injector are required, then three widely used methods should be considered. These are focusing magnet scans, the use of an emittance mask (pepper pot), and optical transition radiation (OTR). We have used all three of these on our accelerators. These are invasive methods. There are noninvasive methods that we have not yet used. For example, under some conditions the beam size obtained with diamagnetic loops can be used in conjunction with the envelope equation to infer emittance. To date our diamagnetic loop data has not been of sufficient quality to do this. Another technique is to measure the beam-distribution quadrupole moment with BPMs dispersed in a quadrupole magnet lattice. Our BPMs have this capability, but the only quad lattice is in the downstream transport (DST), so this method is deferred until we operate the DST. All three methods reviewed here are invasive, and require the insertion of a target into the beam. Therefore, there is always the accompanying risk of inadvertent destruction of the target, and scattering of target material throughout the accelerator or injector. The target damage mechanism is target heating to a temperature hot enough to evolve gas, which is impact ionized by the beam, which is then ion focused to a small enough spot for the energy density to damage the target material, often destructively. Target heating is directly proportional to beam current density and pulse length. Therefore, the key to minimizing risk of target damage is to design for a large beam at the target, low current from the diode, and the shortest possible current pulse. The large-beam requirement compromises emittance measurements with OTR or focal scans, but not with the pepper pot technique. Finally, to ensure a short pulse even if the crowbar fails, the Marx generator should be reconfigured to produce the shortest possible pulse.

43 PARTICLE ACCELERATORS↗

Design of the beam combination section for stochastic injection

The stochastic injection scenario proposed by D. Neuffer in early 1980’s [1] features the injection and acceptance of pions into the muon storage ring, and is used in the design and simulation of nuSTORM injection and ring [2,3]. The pions decay to muons in the long decay straight section of the ring, then the secondary muons are accepted by the straight FODO structure. The critical design element in this scenario is the Beam Combination Section (BCS), which serially includes a defocusing quadrupole, a bending dipole, and a focusing quadrupole. This paper describes in detail the the design of such a BCS and the matching from this BCS to the downstream side of magnetic horn used to collect the pions after target.

43 PARTICLE ACCELERATORS↗

Multipole approximation of special nonlinear magnets for the IOTA ring

All existing focusing optics for accelerators are built to be "linear", i.e. the transverse focusing force is proportional to the particle displacement from the closed orbit. Such approach is used in order to make trajectories stable in the entire area of phase space, because the potential describing linear focusing is integrable and does not produce chaotic motion. Technically, the needed field is achieved with the help of dipole and quadrupole magnets. But the linear motion is unstable to perturbations in the focusing fields and excludes any betatron tune spread over particle's energy, which is beneficial for the beam stability. Moreover, the focusing strength depends on the particle's energy deviation from the designed one. These undesired effects are usually suppressed by the addition of non- linear elements, such as sextupoles and octupoles. Unfortunately, these additions make focusing potential nonintegrabe, leading to the limitation of stable phase space area. Recent research showed, that there exist non-linear potentials that, nevertheless, are fully integrable [1, 2]. Thus, there is an opportunity to create stable non-linear focusing optics that provides high betatron tune spread and mitigate magnetic field errors. This approach is to be implemented in electron storage ring called Integrable Optics Test Accelerator (IOTA) at Fermilab [3]. The main goal is to show the possibility to implement the nonlinear integrable system in a realistic accelerator design. Development of a magnet, which creates exact non-linear potential, is a technically complicated task, that takes much time and efforts. However, it is possible to expand the non- linear potential into superposition of multipoles of even orders (i.e quadrupole, octupole, etc.). Though this series is not convergent in the entire space, a few low order terms can be used to model the true potential in some limited area. In turn, each of the multipole potentials can be generated by speci ed electrical current in PCB coiled on the surface of storage ring's vacuum tube. Such approach is much cheaper than the creation of a magnet of solid iron with high current coil and faster than the development of \exact" non-linear magnet, but it can help identify some features of non-linear integrable optics application. The goal of this research work is to find analytically the angular distribution of electrical current on the surface of the vacuum tube, which creates inside it multipole potential with given parameters. Hereafter, there is the task to develop a model of flexible printed circuit board (PCB), which could be coiled around the vacuum tube in order to provide the desired current distribution.

Vorobev, Viktor↗

Initial Estimates of Dynamic Aperture and Field Quality Specifications

In this report the target field quality for the inner triplets is given. This initial specification is based on the most recent estimate of the expected field quality provided by the magnet designers. The expected field quality has been probed by means of massive numerical simulations, which are aimed at computing the dynamic aperture and its dependence on the triplet quadrupoles field imperfections. The initial estimate of the required field quality will be further analysed against measured data, whenever available, in view of possible refinement of the target errors. A preliminary check of the impact of the field quality of the other insertion magnets, both separation dipoles and quadrupoles, from D1 to Q5 has been made and a quantitative specification of the field quality will follow, always based on the expected field quality estimates.

ACCPHY↗

Emittance growth in the DARHT Axis-II Downstream Transport

Using a particle-in-cell (PIC) code, we investigated the possibilities for emittance growth through the quadrupole magnets of the system used to transport the high-current electron beam from an induction accelerator to the bremsstrahlung converter target used for flash radiography. We found that even highly mismatched beams exhibited little emittance growth (< 6%), which we attribute to softening of their initial hard edge current distributions. We also used this PIC code to evaluate the accuracy of emittance measurements using a solenoid focal scan following the quadrupole magnets. If the beam is round after the solenoids, the simulations indicate that the measurement is highly accurate, but it is substantially inaccurate for elliptical beams

43 PARTICLE ACCELERATORS↗

Polymer and Additive Mass Spectrometry Literature Review

The use of mass spectrometry in fields related to polymers has increased significantly over the past three decades and will be explored in this literature review. The importance of this technique is highlighted when exploring how polymers degrade, verifying purchased materials, and as internal requirements change. The primary focus will be on four ionization techniques and the triple quadrupole and quadrupole / time-of-flight mass spectrometers. The advantages and limitations of each will also be explored.

36 MATERIALS SCIENCE↗

Instrument design optimization with computational methods

Using Finite Element Analysis to approximate the solution of differential equations, two different instruments in experimental Hall C at the Thomas Jefferson National Accelerator Facility are analyzed. The time dependence of density uctuations from the liquid hydrogen (LH2) target used in the Q wea k experiment (2011-2012) are studied with Computational Fluid Dynamics (CFD) and the simulation results compared to data from the experiment. The 2.5 kW liquid hydrogen target was the highest power LH2 target in the world and the first to be designed with CFD at Jefferson Lab. The first complete magnetic field simulation of the Super High Momentum Spectrometer (SHMS) is presented with a focus on primary electron beam deflection downstream of the target. The SHMS consists of a superconducting horizontal bending magnet (HB) and three superconducting quadrupole magnets. The HB allows particles scattered at an angle of 5:5 deg to the beam line to be steered into the quadrupole magnets which make up the optics of the spectrometer. Without mitigation, remnant fields from the SHMS may steer the unscattered beam outside of the acceptable envelope on the beam dump and limit beam operations at small scattering angles. A solution is proposed using optimal placement of a minimal amount of shielding iron around the beam line.

43 PARTICLE ACCELERATORS↗

The Beam Dynamics and Beam Related Uncertainties in Fermilab Muon $g-2$ Experiment

The anomaly of the muon magnetic moment, $a_{\mu}\equiv (g-2)/2$, has played an important role in constraining physics beyond the Standard Model for many years. Currently, the Standard Model prediction for $a_{\mu}$ is accurate to 0.42 parts per million (ppm). The most recent muon $g-2$ experiment was done at Brookhaven National Laboratory (BNL) and determined $a_{\mu}$ to 0.54 ppm, with a central value that differs from the Standard Model prediction by 3.3-3.6 standard deviations and provides a strong hint of new physics. The Fermilab Muon $g-2$ Experiment has a goal to measure $a_{\mu}$ to unprecedented precision: 0.14 ppm, which could provide an unambiguous answer to the question whether there are new particles and forces that exist in nature. To achieve this goal, several items have been identified to lower the systematic uncertainties. In this work, we focus on the beam dynamics and beam associated uncertainties, which are important and must be better understood. We will discuss the electrostatic quadrupole system, particularly the hardware-related quad plate alignment and the quad extension and readout system. We will review the beam dynamics in the muon storage ring, present discussions on the beam related systematic errors, simulate the 3D electric fields of the electrostatic quadrupoles and examine the beam resonances. We will use a fast rotation analysis to study the muon radial momentum distribution, which provides the key input for evaluating the electric field correction to the measured $a_{\mu}$.

Wu, Wanwei↗

Beam Echoes in the Presence of Coupling

Transverse beam echoes could provide a new technique of measuring diusion characteristics orders of magnitude faster than the current methods; however, their interaction with many accelerator parameters is poorly understood. Using a program written in C, we explored the relationship between coupling and echo strength. We found that echoes could be generated in both dimensions, even with a dipole kick in only one dimension. We found that the echo eects are not destroyed even when there is strong coupling, falling o only at extremely high coupling values. We found that at intermediate values of skew quadrupole strength, the decoherence time of the beam is greatly increased, causing a destruction of the echo eects. We found that this is caused by a narrowing of the tune width of the particles. Results from this study will help to provide recommendations to IOTA (Integrable Optics Test Accelerator) for their upcoming echo experiment.

43 PARTICLE ACCELERATORS↗

High Precision Integrated Beam-Position and Emittance Monitor

The purpose of this project was to design and build a set of resonant cavity beam diagnostics including a monopole cavity, two dipole cavities, and a quadrupole mode cavity. An array of such diagnostics placed in an accelerator FODO lattice can be used to reconstruct beam emittance and envelope information on a pulse-by-pulse basis. In this project a more efficient quadrupole cavity shape was discovered which could provide the required sensitivity with just two cells vs. nine cells as originally envisioned. This new design was studied and optimized with RF simulation programs, followed by mechanical specifications and drawings, and fabrication of the diagnostics. The device was tested with a relativistic electron beam at Brookhaven National Laboratory ATF accelerator.

43 PARTICLE ACCELERATORS↗

Reasonable Beam Deviation Envelope for Ray-tracing

At NSLS-II the unused dipole radiation is intercepted by the photon absorbers installed inside the vacuum chamber. The water-cooled absorbers are designed to take away the heat therefore the temperature is kept within the safety limit. However, if the beam orbit is severely perturbed, the radiation fan could pass through the geometry and strikes on the vacuum chamber components. This ray-leakage is a possible reason of the accelerator component temperature rise observed during the high-current operations. The goal of this work is to find the maximum beam deviation at the dipole hence ray-tracing can be re-examined under the operational constraints. The beam is confined to the orbit by the bending and focusing magnets. At NSLS-II the orbit is further controlled by a real time orbit feedback loop. Beam could be lost in any unpredictable direction if the magnet malfunctions. Consequently reasonable assumptions must be made to define the deviation envelope. It was determined that the dipole radiation is not powerful enough to cause damage within 10 ms, for example, if the rf power is shut off and the beam deviates from the orbit. Therefore we consider the radiation produced by the stored beam only; temporarily processes, such as unstable oscillating beam, should not be a concern. The orbit of the stored beam can be altered during magnet failures. The dipole current is interlocked to a small range of ±2% from the nominal value. If the dipole current changes slowly the beam energy automatically adjusts and the orbit remains the same. If the dipole current changes rapidly the beam will not be stable. Therefore dipole variation need not to be considered. For the other magnets we consider one magnet failure at a time because it is unlikely that two fail at the same time. It was found that the beam lifetime drops dramatically if one quadrupole power supply is turned off; therefore this scenario does not meet the stable beam condition. The current of one quadrupole could drop but will not result in orbit change with the feedback on. Beam could survive if one sextupole power supply is turned off, but the orbit will not be changed. Magnet could partially fail, for example, one or part of the coil shorts due to break-down. This is a low probability event and will not be considered. During daily operations the orbit is changed by the correctors and the rf frequency. In this work the correctors and the rf frequency are varied to explore the deviation envelope.

36 MATERIALS SCIENCE↗

NSLS-II Storage Ring Injection Using a Nonlinear Injection Kicker

The NSLS-II has been operating successfully with top off injection since September 2015. Measurements of the stored beam show a transient of 200 μm in the long straight sections during top off injections. This transient is not desirable for some users, particularly those who specialized in imaging or are otherwise sensitive to beam motion. Users are provided with a signal with which they can gate their detectors, but it is desirable to reduce or eliminate this motion all together. Studies have been performed to reduce the transients, and it is clear that the power supplies require more tunability in the pulse shape in order to reduce the transient across the entire bunch train. Other light sources have explored the possibility of using pulsed quadrupoles and sextupoles as the injection magnet. The stored beam receives no kick as the on-axis fields in these magnets is zero, but the injected beam would see a kick as it is off-center. One drawback of the pulsed quadrupole is that the stored beam experiences a size oscillation. Another issue with a nonlinear kicker is the gradient seen by the injected beam. The transport line needs to be tuned for this gradient, and depending on the strength of the nonlinearity, this gradient may change greatly with injected beam position. Therefore, other facilities have explored other magnet configurations that are nonlinear but have a gradient with less positional dependence. The prospect of using a sextupole kicker was investigated during the design phase of the NSLS-II. It was decided that the idea would not be pursued for several reasons. In particular, the design that was studied the most in depth was not compatible with the standard four bump injection design and the tolerances required were deemed too tight at the time. Other ideas were discussed as well and ultimately none were accepted into the design. In this report we discuss the possibility of placing a nonlinear kicker in the first straight section after the injection straight instead of using the injection bumps. The design of the kicker is based on a design that has been used successfully at BESSY and MAX IV. Our conceptual kicker design is compatible with the existing ring optics and power supply requirements. We show that the transport line is capable of being matched to the required optics. The design does not have restrictive tolerances and is a viable option for a facility upgrade.

36 MATERIALS SCIENCE↗

NSLS-II Storage Ring BPM Calibration via LOCO

In the following, we describe a method of the beam based calibration of the beam position monitor (BPM) system in the NSLS-II storage ring (SR) via the LOCO (Linear Optics from Closed Orbits) technique. This method measures the orbit response matrix (ORM) and the dispersion function of the machine. The data are then fitted to a lattice model by adjusting parameters such as quadrupole and skew quadrupole strengths in the model, BPM gains and rolls, corrector gains and rolls of the measurement system. Therefore, BPM gains and rolls are obtained.

36 MATERIALS SCIENCE↗

Betatron Tune Shifts Induced by the Low-Frequency Resistive Wall Impedance

An analytical expression of the low-frequency quadrupole impedance for undulators and wigglers is derived and benchmarked against beam-based impedance measurements done at the 3GeV NSLS-II storage ring. The adopted theoretical model, valid for an arbitrary number of electromagnetic layers with parallel geometry, allows to calculate the quadrupole impedance for arbitrary values of the magnetic permeability $μ_r$. In the comparison of the analytical results with the measurements for variable magnet gaps, two limit cases of the permeability have been studied: the case of perfect magnets ($μ_r$ → $\infty$), and the case in which the magnets are fully saturated ($μ_r$ = 1).

36 MATERIALS SCIENCE↗

LOCO Application to NSLSII SR Dispersion and Beta Beating Correction

During the short run in early July, 2014, we made changes to the Matlab LOCO setup for NSLS-II and applied LOCO successfully to the machine. The MML setup was verified with I/O tests for all quadrupole families. The LOCO setup was further tested with an intentional quadrupole error. After the successful LOCO correction, the rms beta beat was reduced from the initial values of 5.5% x and 5.6% y, to 1.9% x and 1.0% y, respectively. The rms horizontal dispersion error was reduced from 21 mm to 6 mm. It is critical to keep the same closed orbit for LOCO correction to take effect. Because presently some correctors are nearly saturated, closed orbit cannot be controlled for additional iterations. We expect LOCO to achieve better optics correction after the orbit control is improved.

36 MATERIALS SCIENCE↗

NSLS-II: Magnet Tolerances

After a preliminary spot check of the proposed relaxing of the magnetic tolerances for the standard quadrupoles- and sextupoles, we decided to bring our 2006 guidelines up-to-date. Our conclusions are: • The specs on the sextupoles can be relaxed as proposed. In fact, this could have been concluded from our original work. • We do not recommend to back off (significantly) for the specs on the quadrupoles.

36 MATERIALS SCIENCE↗

EM and beam dynamics modeling of CCL with CST Studio

The 800-MeV proton linac at LANSCE consists of a drift-tube linac, which brings the beam to 100 MeV, followed by a coupled-cavity linac (CCL). Each of 44 CCL modules contain multiple tanks, and it is fed by a single 805-MHz klystron. CCL tanks are multi-cell blocks of identical re-entrant sidecoupled cavities, which are followed by drifts with magnetic quadrupole doublets. Bridge couplers – special cavities displaced from the beam axis – electromagnetically couple CCL tanks over such drifts. We have developed 3D CST models of CCL tanks of the LANSCE linac. Their electromagnetic analysis is performed using MicroWave Studio. Beam dynamics is modeled with Particle Studio for bunch trains with realistic beam distributions using the CST calculated RF fields and quadrupole magnetic fields to determine the output beam parameters.

42 ENGINEERING↗

Interaction Region Magnets for Future Electron-Ion Collider at Jefferson Lab

The Jefferson Lab Electron Ion Collider (JLEIC) is a pro-posed new machine for nuclear physics research. It uses the existing CEBAF accelerator as a full energy injector to deliver 3 to 12 GeV electrons into a new electron collider ring. An all new ion accelerator and collider complex will deliver up to 200 GeV protons. The machine has luminosity goals of 1034 cm-2 sec-1. The whole detector region including forward detection covers about 80 meters of the JLEIC complex. The interaction region design has recently been optimized to accommodate 200 GeV proton energy using conventional NbTi superconducting magnet technology. This paper will describe the requirements and preliminary designs for both the ion and electron beam magnets in the most complex 34.5 m long interaction region (IR) around the interaction point (IP). The interaction region has over thirty-four superconducting magnets operating at 4.5K; these include dipoles, quadrupoles, skew quadrupoles, solenoids, horizontal and vertical correctors and higher order multipole magnets. The paper will also dis-cuss the electromagnetic interaction between these magnets.

Rajput-Ghoshal, Renuka↗