Dosimetric comparison of metastatic spinal photon treatment techniques

Traditional palliative treatment of metastatic cancer to the vertebral bodies often results in doses to the spinal cord that are higher than the dose prescribed to the target, or gross tumor volume (GTV). This study compares traditional techniques of spine palliation with intensity-modulated radiation therapy (IMRT). The purpose of the study is 2-fold: first, the study demonstrates the benefits of using IMRT to lower the dose to the organs at risk (OAR), particularly for the spinal cord and other nonspecified normal tissues; second, the article provides information regarding the advantages and disadvantages of commonly used conventional techniques for treating the vertebral bodies based on patient anatomy. Because the use of IMRT or other advanced techniques may be prohibitive because of insurance issues, treatment plans were created that compared optimal coverage vs. optimal sparing for single-field, wedged-pair, and opposed-beam arrangements. Fifty-five patients were selected and divided by location of target (cervical, thoracic, and lumbar spine) and also by the measured separation between the anterior and posterior surface of the patient at the level of mid-GTV. Within each anatomic category the patients again were divided into the categories of small, medium, and large based on separation. The patient dataset that most closely represented the average separation within each category was selected, resulting in a total of 9 patients, and the appropriate treatment plan techniques were calculated for each of the 9 patients. The results of the study do show that the use of IMRT is far superior when compared with other techniques, both for coverage and for sparing of the surrounding tissue, regardless of patient size and the section of spine being treated. Based on a combination of both target coverage and sparing of normal tissues, the conventional plan of choice may vary by both the section of spine to be treated and by the size of the patient.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-J-197: A Novel Intra-Beam Range Detection and Adaptation Strategy for Particle Therapy

Purpose: In-vivo range detection/verification is crucial in particle therapy for effective and safe delivery. The state-of-art techniques are not sufficient for in-vivo on-line range verification due to conflicts among patient dose, signal statistics and imaging time. We propose a novel intra-beam range detection and adaptation strategy for particle therapy. Methods: This strategy uses the planned mid-range spots as probing beams without adding extra radiation to patients. Such choice of probing beams ensures the Bragg peaks to remain inside the tumor even with significant range variation from the plan. It offers sufficient signal statistics for in-beam positron emission tomography (PET) due to high positron activity of therapeutic dose. The probing beam signal can be acquired and reconstructed using in-beam PET that allows for delineation of the Bragg peaks and detection of range shift with ease of detection enabled by single-layered spots. If the detected range shift is within a pre-defined tolerance, the remaining spots will be delivered as the original plan. Otherwise, a fast re-optimization using range-shifted beamlets and accounting for the probing beam dose is applied to consider the tradeoffs posed by the online anatomy. Simulated planning and delivery studies were used to demonstrate the effectiveness of the proposed techniques. Results: Simulations with online range variations due to shifts of various foreign objects into the beam path showed successful delineation of the Bragg peaks as a result of delivering probing beams. Without on-line delivery adaptation, dose distribution was significantly distorted. In contrast, delivery adaptation incorporating detected range shift recovered well the planned dose. Conclusion: The proposed intra-beam range detection and adaptation utilizing the planned mid-range spots as probing beams, which illuminate the beam range with strong and accurate PET signals, is a safe, practical, yet effective approach to address range uncertainty issues in particle therapy.

60 APPLIED LIFE SCIENCES↗

Modeling nuclear energy’s future role in decarbonized energy systems

Increased attention has been focused on the potential role of nuclear energy in future electricity markets and energy systems as stakeholders target rapid and deep decarbonization and reductions in fossil fuel use. This paper examines models of electric sector planning and broader energy systems optimization to understand the prospective roles of nuclear energy and other technologies. In this perspective, we survey modeling challenges in this environment, illustrate opportunities to propagate best practices, and highlight insights from the deep decarbonization literature on the range of visions for nuclear energy's role. Nuclear energy deployment is highest with combinations of stringent emissions policies, nuclear cost reductions, and constraints on the deployment of other technologies, which underscores model dimensions related to these areas. New modeling capabilities are needed to adequately address emerging issues, including representing characteristics and applications of nuclear energy in systems models, and to ensure the relevance of models for policy and planning as deeper decarbonization is explored.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Reconfigurable Software for Controlling Formation Flying

Software for a system to control the trajectories of multiple spacecraft flying in formation is being developed to reflect underlying concepts of (1) a decentralized approach to guidance and control and (2) reconfigurability of the control system, including reconfigurability of the software and of control laws. The software is organized as a modular network of software tasks. The computational load for both determining relative trajectories and planning maneuvers is shared equally among all spacecraft in a cluster. The flexibility and robustness of the software are apparent in the fact that tasks can be added, removed, or replaced during flight. In a computational simulation of a representative formation-flying scenario, it was demonstrated that the following are among the services performed by the software: Uploading of commands from a ground station and distribution of the commands among the spacecraft, Autonomous initiation and reconfiguration of formations, Autonomous formation of teams through negotiations among the spacecraft, Working out details of high-level commands (e.g., shapes and sizes of geometrically complex formations), Implementation of a distributed guidance law providing autonomous optimization and assignment of target states, and Implementation of a decentralized, fuel-optimal, impulsive control law for planning maneuvers.

Mueller, Joseph B.↗

Investigation of Pitch and Jaw Width to Decrease Delivery Time of Helical Tomotherapy Treatments for Head and Neck Cancer

Helical tomotherapy plans using a combination of pitch and jaw width settings were developed for 3 patients previously treated for head and neck cancer. Three jaw widths (5, 2.5, and 1 cm) and 4 pitches (0.86, 0.43, 0.287, and 0.215) were used with a (maximum) modulation factor setting of 4. Twelve plans were generated for each patient using an identical optimization procedure (e.g., number of iterations, objective weights, and penalties, etc.), based on recommendations from TomoTherapy (Madison, WI). The plans were compared using isodose plots, dose volume histograms, dose homogeneity indexes, conformity indexes, radiobiological models, and treatment times. Smaller pitches and jaw widths showed better target dose homogeneity and sparing of normal tissue, as expected. However, the treatment time increased inversely proportional to the jaw width, resulting in delivery times of 24 {+-} 1.9 min for the 1-cm jaw width. Although treatment plans produced with the 2.5-cm jaw were dosimetrically superior to plans produced with the 5-cm jaw, subsequent calculations of tumor control probabilities and normal tissue complication probabilities suggest that these differences may not be radiobiologically meaningful. Because treatment plans produced with the 5-cm jaw can be delivered in approximately half the time of plans produced with the 2.5-cm jaw (5.1 {+-} 0.6 min vs. 9.5 {+-} 1.1 min), use of the 5-cm jaw in routine treatment planning may be a viable approach to decreasing treatment delivery times from helical tomotherapy units.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-AB-202-03: A Novel Tool for Computing Deliverable Doses in Dynamic MLC Tracking Treatments

Purpose: In tracked dynamic multi-leaf collimator (MLC) treatments, segments are continuously adapted to the target centroid motion in beams-eye-view. On-the-fly segment adaptation, however, potentially induces dosimetric errors due to the finite MLC leaf width and non-rigid target motion. In this study, we outline a novel tool for computing the 4d dose of lung SBRT plans delivered with MLC tracking. Methods: The following automated workflow was developed: A) centroid tracking, where the initial segments are morphed to each 4dCT phase based on the beams-eye-view GTV shift (followed by a dose calculation on each phase); B) re-optimized tracking, in which all morphed initial plans from (A) are further optimised (“warm-started”) in each 4dCT phase using the initial optimisation parameters but phase-specific volume definitions. Finally, both dose sets are accumulated to the reference phase using deformable image registration. Initial plans were generated according to the RTOG-1021 guideline (54Gy, 3-Fx, equidistant 9-beam IMRT) on the peak-exhale (reference) phase of a phase-binned 4dCT. Treatment planning and delivery simulations were performed in RayStation (research v4.6) using our in-house segment-morphing algorithm, which directly links to RayStation through a native C++ interface. Results: Computing the tracking plans and 4d dose distributions via the in-house interface takes 5 and 8 minutes respectively for centroid and re-optimized tracking. For a sample lung SBRT patient with 14mm peak-to-peak motion in sup-inf direction, mainly perpendicular leaf motion (0-collimator) resulted in small dose changes for PTV-D95 (−13cGy) and GTV-D98 (+18cGy) for the centroid tracking case compared to the initial plan. Modest reductions of OAR doses (e.g. spinal cord D2: −11cGy) were achieved in the idealized tracking case. Conclusion: This study presents an automated “1-click” workflow for computing deliverable MLC tracking doses in RayStation. Adding a non-deliverable re-optimized tracking scenario is expected to help quantify plan robustness for more challenging patients with anatomy deformations. We acknowledge support of the MLC tracking research from Elekta AB. MFF is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

60 APPLIED LIFE SCIENCES↗

A Stochastic Charging Station Deployment Model for Electrified Taxi Fleets in Coupled Urban Transportation and Power Distribution Networks

Metropolitansworldwide are increasingly adopting electric taxis (ET) to address concerns about transportation-related emissions. However, the widespread deployment of electric taxis presents challenges in terms of increased electricity demand and changing demand profiles. This transition impacts both the urban transportation network (TN) and the electricity power distribution network (PDN), highlighting the interdependence between these two systems. Here, in this paper, we propose a two-stage stochastic programming planning model that aims to optimize both the TN and PDN, enabling efficient deployment of charging stations and grid upgrades. Our model seeks to strike a balance between meeting ET drivers' charging preferences, minimizing the costs associated with infrastructure deployment and grid expansion, and harmonizing the coordination between the TN and PDN. Additionally, we explore the potential benefits of utilizing an autonomous ET fleet to enhance overall system performance.

33 ADVANCED PROPULSION SYSTEMS↗

Optimization of System Maturity and Equivalent System Mass for Exploration Systems Development Planning

The Exploration Systems Mission Directorate of the National Aeronautics and Space Administration (NASA) is currently pursuing the development of the next generation of human spacecraft and exploration systems throughout the Constellation Program. This includes, among others, habitation technologies for supporting lunar and Mars exploration. The key to these systems is the Exploration Life Support (ELS) system that composes several technology development projects related to atmosphere revitalization, water recovery, waste management and habitation. The proper functioning of these technologies is meant to produce sufficient and balanced resources of water, air, and food to maintain a safe and comfortable environment for long-term human habitation and exploration of space.

Magnaye, Romulo↗

A Minimum Principle-Based Algorithm for Energy-Efficient Eco-Driving of Electric Vehicles in Various Traffic and Road Conditions

Our report presents an optimization algorithm for energy-efficient driving of electric vehicles. The algorithm is based on Pontryagin’s Minimum Principle by considering the driving mission as an optimal control problem. On a planned route, diverse application cases may occur due to various physical traits such as powertrain (e.g., switching between motor and generator operation), environmental variations (e.g., terrain grade change), traffic laws (e.g., speed limits), and safety concerns (e.g., headway to the leading vehicle). The proposed algorithm handles these real-world challenges by considering the perturbation to the system dynamics and the constraints to the control and state variables.

33 ADVANCED PROPULSION SYSTEMS↗

WE-DE-201-03: Combined Use of 192Ir, 60Co, and 169Yb Sources with the Novel Direction Modulated Brachytherapy Tandem Applicator for High Dose Rate Brachytherapy Planning of Cervical Cancer

Purpose: To evaluate the improvement in plan quality when various combinations of 192Ir, 60Co, and 169Yb sources are used in combination with a novel direction modulated brachytherapy (DMBT) tandem applicator for high dose rate brachytherapy of cervical cancer. Methods: The proposed DMBT tandem applicator is designed for image-guided adaptive brachytherapy (IGABT), especially MRI, of cervical cancer. It has 6 peripheral holes of 1.3-mm width, grooved along a 5.4-mm diameter nonmagnetic tungsten alloy rod of density 18.0 g/cc, capable of generating directional dose profiles - leading to enhanced dose sculpting capacity through inverse planning. Monte Carlo simulations of the three HDR sources individually inside the DMBT applicator were performed and imported into an in-house developed inverse optimization code. We then performed inverse planning with 14 cervical cancer patients enrolled in EMBRACE study. In all patients, 3D MRI-based planning was performed while utilizing 1) tandem-ring and needles attached-to-ring (7 patients) and 2) tandem-ring and needles both attached-to-ring and free-hand-loaded (7 patients), in accordance with the GEC-ESTRO recommendations. All plans were normalized to receive the same HRCTV D90 and DVH parameters were evaluated. Results: The DMBT tandem was used in all cases. Overall, the combined use of two sources (192Ir-60Co and 192Ir-169Yb, but not 60Co-169Yb) generally produced better quality plans than with the 192Ir source alone in terms of sparing OARs. For example, up to 3.5, 4.4, and 3.9% individual reductions in D2cc were observed for the bladder, rectum, and sigmoid, respectively, between 192Ir-60Co and 192Ir-only plans for patient cases in #1. While up to 5.5, 2.0, and 5.7% individual reductions were observed for patient cases in #2. Conclusion: We have demonstrated that, in addition to “directional modulation” of DMBT, use of multiple sources with sufficient differences in energy can be utilized to achieve additional improvement in plan quality for IGABT of cervical cancer.

60 APPLIED LIFE SCIENCES↗

Interpolation Approximation of Voltage Stability Constrained OPF (VSCOPF) for Reactive Power Planning

Reactive power planning (RPP), or Var planning, is to identify the optimal size and location of reactive power sources. In this paper, first, the previous work using least square method to simplify the voltage stability constrained OPF (VSCOPF) model for RPP is presented. Then, this paper presents a new model simplification solution using interpolation. The interpolation approach can be easily applied to a piecewise formulation while preserving the continuity at boundary points, which cannot be easily achieved by previous works like the least square method. The proposed interpolation approach is numerically tested and compared with the least square approach. It is concluded that interpolation is an improved model simplification approach for RPP.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Coordinated Planning Strategy for Integrated Energy Systems in a District Energy Sector

With the ever-growing integration of diverse distributed energy resources, modern district energy sectors are transitioning into integrated energy systems (IESs), which generally consist of various energy carriers such as electric power, natural gas, and heat. Instead of modeling individual energy carriers, the emergence of IESs requires comprehensive consideration of all involved energy systems in both planning and operation phases. This paper proposes a comprehensive planning strategy for a district energy sector to address the challenges of IES planning considering the coupling of power, gas, and heat systems. The proposed planning model contains an operational module that develops a steady-state optimal multi-energy flow (OMEF) for the IES considered and a multi-stage expansion module that optimizes the investment decisions. To efficiently solve the proposed planning model, which is formulated as a mixed-integer nonlinear programming problem, an improved generalized Benders decomposition algorithm that utilizes dynamic dual multipliers to improve the convergence speed is employed. The effectiveness of the proposed planning model and the feasibility of the improved Benders decomposition algorithm are verified in case studies.

coordinated planning↗

Optimization of Isocenter Location for Intensity Modulated Stereotactic Treatment of Small Intracranial Targets

Purpose: To quantify the impact of isocenter location on treatment plan quality for intensity-modulated stereotactic treatment of small intracranial lesions. Methods and Materials: For 18 patients previously treated by stereotactic-intensity modulated radiosurgery (IMRS) or intensity-modulated radiation therapy (IMRT), a retrospective virtual planning study was conducted wherein the impact of isocenter location on plan quality was measured. Treatment indications studied included six arteriovenous malformations, six acoustic neuromas, and six intracranial metastases, ranging in volume from 0.71 to 3.21 cm{sup 3} (mean = 2.26 cm{sup 3}), 1.08 to 2.84 cm{sup 3} (mean = 1.73 cm{sup 3}), and 0.19 to 2.30 cm{sup 3} (mean = 0.79 cm{sup 3}), respectively. Variation of isocenter location causes the geometric grid of pencil beams into which the target is segmented for intensity-modulated treatment to be altered. The impact of this pencil-beam-grid redefinition on achievable conformity index was quantified for three collimators (Varian Millennium 120; BrainLab MM3; Nomos binary Mimic) and three treatment planning systems (TPS; Varian Eclipse v6.5; BrainLab BrainScan v5.31; Best-Nomos Corvus v6.2), resulting in the evaluation of 3,446 treatment plans. Results: For all patients, collimator, and TPS combinations studied, a significant variation in plan quality was observed as a function of isocenter and pencil-beam-grid relocation. Optimization of isocenter location resulted in treatment plan conformity variations as large as 109% (min = 15%, mean = 51%, max = 109%). Conclusion: Optimization of isocenter location for IMRT/IMRS treatment of small intracranial lesions in which pencil-beam dimensions are comparable to target dimensions, can result in significant improvements in treatment plan quality.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Low-Earth Orbit Trajectory Optimization in the Presence of Atmospheric Uncertainty

The previous 20 to 25 years have seen a tremendous increase in space exploration, and with that an increase in the level of logistics planning needed to ensure mission success. For spacecraft that are designed to be periodically re-supplied, a key logistics consumable is propellant, as it constitutes the greatest up-mass on re-supply vehicles. A trajectory design strategy is therefore desired that minimizes propellant usage in order to ease the demand for propellant re-supply missions. This thesis develops such a strategy in three stages, and uses the International Space Station (ISS) as its testbed, as no other LEO spacecraft is more challenging from a space logistics standpoint. First, the ISS trajectory planning problem is formulated as a constrained burn optimization problem assuming a deterministic atmosphere. The cost function is total ∆v, with constraints imposed on longitude of ascending viii node (LAN) and semi-major axis (SMA) altitude. Analytic derivatives are constructed for both the cost and constraints, which are necessary given the 6-week to 2-year time frames being considered. A gradient-based optimizer is then utilized to find locally-optimal solutions to real-world ISS trajectory planning problems. Second, atmospheric uncertainty is addressed by constructing a probabilistic model of space weather data using Gaussian Processes (GPs). Bayesian inference is performed using the GP model to generate mean and covariance estimates for space weather predictions, whose pedigree is assessed against test data. The predictions are then mapped into atmospheric density via the analytic Jacchia-Roberts density model, and the effect of space weather uncertainty on orbital lifetime is examined. Third, an ISS burn execution uncertainty model is developed. This model, along with the space weather uncertainty model, are deployed in a linear covariance analysis to ascertain their combined effect on LAN and SMA altitude dispersions. The deterministic constraints from the original problem are re-formulated as stochastic constraints, where now the constraint uncertainty interval is required to fall within specified bounds. An updated optimization framework is constructed using the original ∆v cost function along with the stochastic constraints to solve the trajectory optimization problem under atmospheric uncertainty. Finally, the complete architecture is summarized for deployment in an operational setting.

Trajectory Optimization↗

A High-Resolution Merged Wind Dataset for DYNAMO: Progress and Future Plans

In order to support research on optimal data assimilation methods for the Cyclone Global Navigation Satellite System (CYGNSS), launching in 2016, work has been ongoing to produce a high‐resolution merged wind dataset for the Dynamics of the Madden Julian Oscillation (DYNAMO) field campaign, which took place during late 2011/early 2012. The winds are produced by assimilating DYNAMO observations into the Weather Research and Forecasting (WRF) three‐dimensional variational (3DVAR) system. Data sources from the DYNAMO campaign include the upper‐air sounding network, radial velocities from the radar network, vector winds from the Advanced Scatterometer (ASCAT) and Oceansat‐2 Scatterometer (OSCAT) satellite instruments, the NOAA High Resolution Doppler Lidar (HRDL), and several others. In order the prep them for 3DVAR, significant additional quality control work is being done for the currently available TOGA and SMART‐R radar datasets, including automatically dealiasing radial velocities and correcting for intermittent TOGA antenna azimuth angle errors. The assimilated winds are being made available as model output fields from WRF on two separate grids with different horizontal resolutions ‐ a 3‐km grid focusing on the main DYNAMO quadrilateral (i.e., Gan Island, the R/V Revelle, the R/V Mirai, and Diego Garcia), and a 1‐km grid focusing on the Revelle. The wind dataset is focused on three separate approximately 2‐week periods during the Madden Julian Oscillation (MJO) onsets that occurred in October, November, and December 2011. Work is ongoing to convert the 10‐m surface winds from these model fields to simulated CYGNSS observations using the CYGNSS End‐To‐End Simulator (E2ES), and these simulated satellite observations are being compared to radar observations of DYNAMO precipitation systems to document the anticipated ability of CYGNSS to provide information on the relationships between surface winds and oceanic precipitation at the mesoscale level. This research will improve our understanding of the future utility of CYGNSS for documenting key MJO processes.

Lang, Timothy J.↗

Inverse planning for IMRT with nonuniform beam profiles using total-variation regularization (TVR)

Purpose: Radiation therapy with high dose rate and flattening filter-free (FFF) beams has the potential advantage of greatly reduced treatment time and out-of-field dose. Current inverse planning algorithms are, however, not customized for beams with nonuniform incident profiles and the resultant IMRT plans are often inefficient in delivery. The authors propose a total-variation regularization (TVR)-based formalism by taking the inherent shapes of incident beam profiles into account. Methods: A novel TVR-based inverse planning formalism is established for IMRT with nonuniform beam profiles. The authors introduce a TVR term into the objective function, which encourages piecewise constant fluence in the nonuniform FFF fluence domain. The proposed algorithm is applied to lung and prostate and head and neck cases and its performance is evaluated by comparing the resulting plans to those obtained using a conventional beamlet-based optimization (BBO). Results: For the prostate case, the authors' algorithm produces acceptable dose distributions with only 21 segments, while the conventional BBO requires 114 segments. For the lung case and the head and neck case, the proposed method generates similar coverage of target volume and sparing of the organs-at-risk as compared to BBO, but with a markedly reduced segment number. Conclusions: TVR-based optimization in nonflat beam domain provides an effective way to maximally leverage the technical capacity of radiation therapy with FFF fields. The technique can generate effective IMRT plans with improved dose delivery efficiency without significant deterioration of the dose distribution.