Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Statistical tests of additional plate boundaries from plate motion inversions

The application of the F-ratio test, a standard statistical technique, to the results of relative plate motion inversions has been investigated. The method tests whether the improvement in fit of the model to the data resulting from the addition of another plate to the model is greater than that expected purely by chance. This approach appears to be useful in determining whether additional plate boundaries are justified. Previous results have been confirmed favoring separate North American and South American plates with a boundary located beween 30 N and the equator. Using Chase's global relative motion data, it is shown that in addition to separate West African and Somalian plates, separate West Indian and Australian plates, with a best-fitting boundary between 70 E and 90 E, can be resolved. These results are generally consistent with the observation that the Indian plate's internal deformation extends somewhat westward of the Ninetyeast Ridge. The relative motion pole is similar to Minster and Jordan's and predicts the NW-SE compression observed in earthquake mechanisms near the Ninetyeast Ridge.

Stein, S.↗

Stimulus factors in motion perception and spatial orientation

The Malcolm horizon utilizes a large projected light stimulus Peripheral Vision Horizon Device (PVHD) as an attitude indicator in order to achieve a more compelling sense of roll than is obtained with smaller devices. The basic principle is that the larger stimulus is more similar to visibility of a real horizon during roll, and does not require fixation and attention to the degree that smaller displays do. Successful implementation of such a device requires adjustment of the parameters of the visual stimulus so that its effects on motion perception and spatial orientation are optimized. With this purpose in mind, the effects of relevant image variables on the perception of object motion, self motion and spatial orientation are reviewed.

Post, R. B.↗

Quantification of Cross-coupling and Motion Feedthrough for Multiaxis Controllers Used in an Air Combat Flying Task

A real-time piloted simulation of an air-to-air combat flying task using a wings-level-turn aircraft and various novel controllers was conducted. One objective is to quantify how the pilot interacts with the controllers and control modes, including: (1) controller versus aircraft response; (2) proprioceptive cross-coupling among axes of the controllers; and (3) biodynamic cross-coupling between the aircraft motions and the controllers. In order to aid in identifying the items listed above, both the target aircraft and the large amplitude multimode aerospace research simulator (LAMARS) motion system were distributed with quasi-random sums-of-sinusoids. Since the disturbances were separated in frequency, spectral analysis techniques were used to identify the three items listed. The results of the spectral analysis of controller motions from the two-axis side stick, a twist grip mounted on the side stick, a thumb button mounted on the side stick, and conventional rudder pedals are presented. Conclusions and recommendations for further research are also presented.

Jewell, W. E.↗

Accuracy of System Step Response Roll Magnitude Estimation from Central and Peripheral Visual Displays and Simulator Cockpit Motion

An experiment to investigate visual roll attitude and roll rate perception is described. The experiment was also designed to assess the improvements of perception due to cockpit motion. After the onset of the motion, subjects were to make accurate and quick estimates of the final magnitude of the roll angle step response by pressing the appropriate button of a keyboard device. The differing time-histories of roll angle, roll rate and roll acceleration caused by a step response stimulate the different perception processes related the central visual field, peripheral visual field and vestibular organs in different, yet exactly known ways. Experiments with either of the visual displays or cockpit motion and some combinations of these were run to asses the roles of the different perception processes. Results show that the differences in response time are much more pronounced than the differences in perception accuracy.

Hosman, R. J. A. W.↗

The effect of the arbitrary level assignment of satellite cloud motion wind vectors on wind analyses in the pre-thunderstorm environment

The impact of satellite-derived cloud motion vectors on SESAME rawinsonde wind fields was studied in two separate cases. The effect of wind and moisture gradients on the arbitrary assignment of the satellite data is assessed to coordinate surfaces in a severe storm environment marked by strong vertical wind shear. Objective analyses of SESAME rawinsonde winds and combined winds are produced and differences between these two analyzed fields are used to make an assessment of coordinate level choice. It is shown that the standard method of arbitrarily assigning wind vectors to a low level coordinate surface yields systematic differences between the rawinsonde and combined wind analyses. Arbitrary assignment of cloud motions to the 0.9 sigma surface produces smaller differences than assignment to the 825 mb pressure surface. Systematic differences occur near moisture discontinuities and in regions of horizontal and vertical wind shears. The differences between the combined and SESAME wind fields are made smallest by vertically interpolating cloud motions to either a pressure or sigma surface.

Peslen, C. A.↗

Susceptibility of cat and squirrel monkey to motion sickness induced by visual stimulation: Correlation with susceptibility to vestibular stimulation

Experiments in which the susceptibility of both cats and squirrel monkeys to motion sickness induced by visual stimulation are documented. In addition, it is shown that in both species those individual subjects most highly susceptible to sickness induced by passive motion are also those most likely to become motion sick from visual (optokinetic) stimulation alone.

Daunton, N. G.↗

The Effects of Image Motion on the L-nu Diagram

A simple two dimensional (x,t) model of the solar oscillatory velocity field is subjected to a form of differential image motion. This image motion is meant to approximately model the effect of the Earth's atmosphere on observations of high degree solar oscillations. The distorted velocity field is analyzed to provide the apparent frequencies of the modes. It is shown that the image motion can produce a discrepancy of as much as 12 micro Hz.

Hill, F.↗

Diagnosis of vertical motions from VAS retrievals during a convective outbreak

GOES-VAS satellite retrievals are used to investigate an intense convective outbreak over the Mississippi River Valley on 21-22 July 1982. The primary goals are to assess the strengths and weaknesses of three methods for computing vertical motion using satellite retrievals and to determine the effects of short interval observations on the calculations. Then, the vertical motions are incorporated with thermodynamic parameters to assess the usefulness of VAS data in delineating factors leading to storm formation. Results indicate that the quasi-geotrophic omega equation provided patterns and magnitudes most consistent with observed weather events and the 12 h radiosonde-derived motions. The vorticity method generally produced reasonable patterns, especially over the convective outbreak, although magnitudes were large due to its time derivative.

Funk, T. W.↗

Model of human visual-motion sensing

A model of how humans sense the velocity of moving images is proposed. The model exploits constraints provided by human psychophysics, notably that motion-sensing elements appear tuned for two-dimensional spatial frequency, and by the frequency spectrum of a moving image, namely, that its support lies in the plane in which the temporal frequency equals the dot product of the spatial frequency and the image velocity. The first stage of the model is a set of spatial-frequency-tuned, direction-selective linear sensors. The temporal frequency of the response of each sensor is shown to encode the component of the image velocity in the sensor direction. At the second stage, these components are resolved in order to measure the velocity of image motion at each of a number of spatial locations and spatial frequencies. The model has been applied to several illustrative examples, including apparent motion, coherent gratings, and natural image sequences. The model agrees qualitatively with human perception.

Watson, A. B.↗

Application of the finite-state arbitrary-motion aerodynamics to rotor blade aeroelastic response and stability in hover and forward flight

The primary objective of this paper is to illustrate the influence of finite-state arbitrary-motion time-domain aerodynamics on rotor blade aeroelastic stability in hover and forward flight. The essential ingredients of the generalized Greenberg type time-domain unsteady aerodynamics are presented and incorporated in a coupled nonlinear flap-lag analysis. Aeroelastic stability boundaries for both hover and forward flight are obtained using both arbitrary-motion time-domain aerodynamics and quasi-steady aerodynamics. The sensitivity of flap-lag aeroelastic stability boundaries to time-domain arbitrary-motion unsteady aerodynamics is evaluated by comparing the two sets of results for various blade configurations and flight conditions.

Dinyavari, M. A. H.↗

Hurricane Debby - An illustration of the complementary nature of VAS soundings and cloud and water vapor motion winds

The utility of VISSR Atmospheric Sounder (VAS) temperature and moisture soundings and cloud and water vapor motion winds in defining a storm and its surroundings at subsynoptic scales has been examined using a numerical analysis and prognosis system. It is shown that the VAS temperature and moisture data, which specify temperature and moisture well in cloud-free areas, are complemented by cloud and water vapor motion data generated in the cloudy areas. The cloud and water vapor 'winds' provide thermal gradient information for interpolating the soundings across cloudy regions. The loss of analysis integrity due to the reduction of VAS sounding density in the cloudy regions associated with synoptic activity is ameliorated by using cloud and water vapor motion winds. The improvement in numerical forecasts resulting from the addition of these data to the numerical analysis is recorded.

Le Marshall, J. F.↗

The effect of wind and moisture gradients on the arbitrary assignment of cloud motions to a vertical coordinate system in two Sesame cases

Satellite-derived cloud motion 'wind' vectors (CMV) are increasingly used in mesoscale and in global analyses, and questions have been raised regarding the uncertainty of the level assignment for the CMV. One of two major problems in selecting a level for the CMV is related to uncertainties in assigning the motion vector to either the cloud top or base. The second problem is related to the inability to transfer the 'wind' derived from the CMV at individually specified heights to a standard coordinated surface. The present investigation has the objective to determine if the arbitrary level assignment represents a serious obstacle to the use of cloud motion wind vectors in the mesoscale analysis of a severe storm environment.

Peslen, C. A.↗

A stimulator for laboratory studies of motion sickness in cats

A motion sickness device is described which produces motion sickness in about 40 percent of an unselected population of unrestrained female cats during a 30-min exposure at 0.28 Hz. The apparatus provides a gentle wave stimulus, similar to that provided by an amusement park Ferris Wheel. Two cats may be tested at the same time. This device is useful for studies of putative antimotion sickness drugs or the biochemical basis of the emetic response to motion.

Crampton, G. H.↗

Stimulus specificity and individual stereotypy of autonomic responses to motion stressors

Motion sickness research shows a lack of agreement regarding the contribution of the autonomic nervous system (ANS). The resolution of this question is exigent for Space Adaptation Syndrome, zero gravity sickness. A case is drawn for the necessity to apply a methodological approach that incorporates: (1) standardization of parameters in relation to the individual differences in variability and prestimulus levels; (2) a concern for patterning of responses; and (3) the physiological association with subjective reports. Vasomotor, heart rate, respiration rate, skin conductance and subjective reports of malaise were collected from 22 subjects while participating in three motion stressors; vertical acceleration, Coriolis stimulation, and combined optokinetic and Coriolis stimulation. The results demonstrate that ANS response patterns can be separated into three mutually exclusive components: (1) a generalized response to motion sickness; (2) a stimulus specific response to the type of stressor being presented; and (3) individualized stereotypical response patterns that are associated with subjective reports of malaise.

Morgan, M. G.↗

A new look at arbitrary motion unsteady aerodynamics and its application to rotary-wing aeroelasticity

Research on arbitrary motion unsteady aerodynamics, emphasizing applications to rotary wing aeroelastic problems, is reviewed. Generalization of Greenberg's theory and its application to hingeless rotor aeroelastic stability; a technique for formulating finite state approximations to unsteady aerodynamic theories, suitable for fixed and rotary-wing applications, and its application to generalize Loewy's theory; comparison of fixed wing and rotary wing indicial response functions; influence of arbitrary motion aerodynamics, as represented by dynamic inflow on a helicopter in ground resonance; and comparison of dynamic inflow with arbitrary motion unsteady airfoil aerodynamics are covered.

Friedmann, P. P.↗

Arousal and stability - The effects of five new sympathomimetic drugs suggest a new principle for the prevention of space motion sickness

Sympathomimetic agents are frequent components in antimotion-sickness drug combinations because of their usefulness in counteracting the sedation caused by stressful motion or resulting from the administration of other antimotion-sickness drugs. The noradrenergic neurochemistry of the brain's arousal-attentional systems prompted us to evaluate the efficacy of five new sympathomimetic drugs and to further define the role of arousal in susceptibility to motion. Subjects were orally administered methamphetamine (20 mg), phenmetrazine (25 mg), phentermine (37.5 mg), methylphenidate (20 mg), or pemoline (75 mg) 2 h prior to taking a Staircase Profile Test. All of the drugs increased resistance to stressful coriolis stimulation by 80-120 percent. Methylphenidate and pemoline showed fewer side effects. These findings, interpreted in conjunction with the documented inefficacy of most anticholinergic and antihistaminergic drugs tested to date, suggest that sympathomimetic drugs or a generalized state of arosusal can inhibit the development of motion sickness.

Kohl, R. L.↗

The effective intensity of Coriolis, cross-coupling stimulation is gravitoinertial force dependent - Implications for space motion sickness

The effect of gravity on the severity of the Coriolis-induced motion sickness was investigated in ten individuals subjected to high and low G-force phases of parabolic flight maneuvers using constant level Coriolis, cross-coupled angular acceleration stimulation. Using seven levels of severity in the diagnosis of motion sickness, it was found that the subjects were less susceptible at 0 G than at +2 Gz, and that the perceived intensity and provocativeness of Coriolis stimulation decreased in 0 G and increased in +2 Gz relative to the +1 Gz baseline values. The changes in the apparent intensity of Coriolis stimulation occur virtually immediately when the background gravitatioinertial force level is varied. These findings explain why the Skylab astronauts were refractory to motion sickness during Coriolis stimulation in-flight.

Lackner, J. R.↗

The effect of the arbitrary level assignment of satellite cloud motion wind vectors on wind analyses in the pre-thunderstorm environment

The impact of satellite-derived cloud motion vectors on SESAME rawinsonde wind fields was studied in two separate cases. The effect of wind and moisture gradients on the arbitrary assignment of the satellite data is assessed to coordinate surfaces in a severe storm environment marked by strong vertical wind shear. Objective analyses of SESAME rawinsonde winds and combined winds are produced and differences between these two analyzed fields are used to make an assessment of coordinate level choice. It is shown that the standard method of arbitrarily assigning wind vectors to a low level coordinate surface yields systematic differences between the rawinsonde and combined wind analyses. Arbitrary assignment of cloud motions to the 0.9 sigma surface produces smaller differences than assignment to the 825 mb pressure surface. Systematic differences occur near moisture discontinuities and in regions of horizontal and vertical wind shears. The differences between the combined and SESAME wind fields are made smallest by vertically interpolating cloud motions to either a pressure or sigma surface.

Peslen, C. A.↗