Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “modal test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Transonic flutter study of a wind-tunnel model of an arrow-wing supersonic transport

A 1/20-size, low-speed flutter model of the SCAT-15F complete airplane was tested on cables to simulate a near free-flying condition. Only the model wing and fuselage were flexible. Flutter boundaries were measured for a nominal configuration and a configuration with wing fins removed at Mach numbers M from 0.76 to 1.2. For both configurations, the transonic dip in the wing flutter dynamic pressure q boundary was relatively small and the minimum flutter q occurred near M = 0.92. Removing the wing fins increased the flutter q about 14 percent and changed the flutter mode from symmetric to antisymmetric. Vibration and flutter analyses were made using a finite-element structural representation and subsonic kernel-function aerodynamics. For the nominal configuration, the analysis (using calculated modal data) predicted the experimental flutter q levels within 10 percent but did not predict the correct flutter mode at the higher M. For the configuration without wing fins, the analysis predicted 16 to 36 percent unconservative (higher than experimental) flutter q levels and showed extreme sensitivity to mass representation details that affected wing tip mode shapes. For high subsonic M, empennage aerodynamics had a significant effect on the predicted flutter boundaries of several symmetric modes.

Ruhlin, C. L.↗

Evaluation of mounting bolt loads for Space Shuttle Get Away Special (GAS) adapter beam

During the prototype vibration tests of the GAS adapter beam, significant impacting of the beam at its support points was observed. The cause of the impacting was traced to gaps under the mounting bolt heads. Because of the nonlinear nature of the response, it was difficult to evaluate the effects which Shuttle launch dynamics might have on the mounting bolt loads. A series of tests were conducted on an electrodynamic exciter in which the transient acceleration time histories, which had been measured during the Space Transportation System-1 (STS-1; Space Shuttle mission 1) launch, were simulated. The actual flight data had to be filtered and compensated so that it could be reproduced on the shaker without exceeding displacement and velocity limitations. Mounting bolt loads were measured directly by strain gages applied to the bolts. Various gap thicknesses and bolt torques were investigated. Although increased gap thickness resulted in greater accelerations due to impacting, the bolt loads were not significantly affected. This is attributed to the fact that impacting excited mostly higher frequency modes which do not have significant modal mass.

Talapatra, D. C.↗

Evaluation of analysis techniques for low frequency interior noise and vibration of commercial aircraft

The application of selected analysis techniques to low frequency cabin noise associated with advanced propeller engine installations is evaluated. Three design analysis techniques were chosen for evaluation including finite element analysis, statistical energy analysis (SEA), and a power flow method using element of SEA (computer program Propeller Aircraft Interior Noise). An overview of the three procedures is provided. Data from tests of a 727 airplane (modified to accept a propeller engine) were used to compare with predictions. Comparisons of predicted and measured levels at the end of the first year's effort showed reasonable agreement leading to the conclusion that each technique had value for propeller engine noise predictions on large commercial transports. However, variations in agreement were large enough to remain cautious and to lead to recommendations for further work with each technique. Assessment of the second year's results leads to the conclusion that the selected techniques can accurately predict trends and can be useful to a designer, but that absolute level predictions remain unreliable due to complexity of the aircraft structure and low modal densities.

Landmann, A. E.↗

Online Multi-Modal Learning and Adaptive Information Trajectory Planning for Autonomous Exploration

In robotic information gathering missions, scientists are typically interested in understanding variables which require proxy measurements from specialized sensor suites to estimate. However, energy and time constraints limit how often these sensors can be used in a mission. Robots are also equipped with cheaper to use navigation sensors such as cameras. In this paper, we explore a challenging planning problem in which a robot is required to learn about a scientific variable of interest in an initially unknown environment by planning informative paths and deciding when and where to use its sensors. To tackle this we present two innovations: a Bayesian generative model framework to automatically learn correlations between expensive science sensors and cheaper to use navigation sensors online, and a sampling based approach to plan for multiple sensors while handling long horizons and budget constraints. Our approach does not grow in complexity with data and is anytime making it highly applicable to field robotics. We tested our approach extensively in simulation and validated it with real data collected during the 2014 Mojave Volatiles Prospector Mission. Our planning algorithm performs statistically significantly better than myopic approaches and at least as well as a coverage-based algorithm in an initially unknown environment while having added advantages of being able to exploit prior knowledge and handle other intricacies of the real world without further algorithmic modifications.

learning↗

A Data-Driven Framework for Direct Local Tensile Property Prediction of Laser Powder Bed Fusion Parts

This article proposes a generalizable, data-driven framework for qualifying laser powder bed fusion additively manufactured parts using part-specific in situ data, including powder bed imaging, machine health sensors, and laser scan paths. To achieve part qualification without relying solely on statistical processes or feedstock control, a sequence of machine learning models was trained on 6299 tensile specimens to locally predict the tensile properties of stainless-steel parts based on fused multi-modal in situ sensor data and a priori information. A cyberphysical infrastructure enabled the robust spatial tracking of individual specimens, and computer vision techniques registered the ground truth tensile measurements to the in situ data. The co-registered 230 GB dataset used in this work has been publicly released and is available as a set of HDF5 files. The extensive training data requirements and wide range of size scales were addressed by combining deep learning, machine learning, and feature engineering algorithms in a relay. The trained models demonstrated a 61% error reduction in ultimate tensile strength predictions relative to estimates made without any in situ information. Lessons learned and potential improvements to the sensors and mechanical testing procedure are discussed.

36 MATERIALS SCIENCE↗

SU-F-T-645: To Test Spatial Anddosimetric Accuracy of Small Cranial Target Irradiation Based On 1.5 T MRIscans Using Static Arcs with MLCDefined Fields

Purpose: To test spatial and dosimetric accuracy of small cranial target irradiation based on 1.5 T MRI scans using static arcs with MLC-defined fields Methods: A plastic (PMMA) phantom simulating a small brain lesion was mounted on a GammaKnife headframe equipped with MRI localizer. The lesion was a 3 mm long, 3.175 mm diameter cylindrical cavity filled with MRI contrast. Radiochromic film passing through the cavity was marked with pin pricks at the cavity center. The cavity was contoured on an MRI image and fused with CT to simulate treatment of a lesion not visible on CT. The transfer of the target to CT involved registering the MRI contrast cannels of the localizer that were visible on both modalities. Treatments were planned to deliver 800 cGy to the cavity center using multiple static arcs with 5.0×2.4 mm MLC-defined fields. The phantom was aligned on a STx accelerator by registering the conebeam CT with the planning CT. Films from coronal and sagittal planes were scanned and evaluated using ImageJ software Results: Geographic errors in treatment based on 1.5 T scans agreed within 0.33, −0.27 and 1.21 mm in the vertical, lateral and longitudinal dimensions, respectively. The doses delivered to the cavity center were 7.2% higher than planned. The dose distributions were similar to those of a GammaKnife. Conclusion: Radiation can be delivered with an accelerator at mm accuracy to small cranial targets based on 1.5 MRI scans fused to CTs using a standard GammaKnife headframe and MRI localizer. MLC-defined static arcs produce isodose lines very similar to the GammaKnife.

60 APPLIED LIFE SCIENCES↗

Fuselage shell and cavity response measurements on a DC-9 test section

A series of fuselage shell and cavity response measurements conducted on a DC-9 aircraft test section are described. The objectives of these measurements were to define the shell and cavity model characteristics of the fuselage, understand the structural-acoustic coupling characteristics of the fuselage, and measure the response of the fuselage to different types of acoustic and vibration excitation. The fuselage was excited with several combinations of acoustic and mechanical sources using interior and exterior loudspeakers and shakers, and the response to these inputs was measured with arrays of microphones and accelerometers. The data were analyzed to generate spatial plots of the shell acceleration and cabin acoustic pressure field, and corresponding acceleration and pressure wavenumber maps. Analysis and interpretation of the spatial plots and wavenumber maps provided the required information on modal characteristics, structural-acoustic coupling, and fuselage response.

Simpson, M. A.↗

Comparison of OVERFLOW Computational and Experimental Results for a Blunt Mars Entry Vehicle Concept during Supersonic Retropropulsion

Simulations of unsteady supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle were performed using the OVERFLOW Computational Fluid Dynamics (CFD) solver. High-fidelity flow solver techniques, including Detached Eddy Simulation (DES) turbulence modeling and Adaptive Mesh Refinement (AMR), were employed to obtain improved realism in CFD predictions. Simulation conditions and geometry configurations were designed to match specific runs in the Descent System Study (DSS) wind tunnel testing (WTT) campaign. The accuracy of each simulation is assessed by direct comparison to experimental data. Comparisons of computational predictions of the SRP flowfield and bow shock shape to experimental schlieren imaging show reasonable prediction of mean shock shape, with approximately 10% similarity in shock standoff distance for selected conditions, as well as similarity in local, time-varying fluctuations of the shock-plume interaction. Comparisons of discrete measurements of surface pressure coefficient (Cp) indicate CFD accuracy within approximately 10% of the experiment across the majority of the model heatshield, with larger variations at some of the heatshield edge locations with stronger flow unsteadiness. Simulated unsteadiness of these chaotic flows, which were highly dynamic and multi-modal, was shown to be within 20-40% of experimentally-measured pressure standard deviation (SD) for the majority of the sampled locations.

Supersonic Retropropulsion↗

Comparison of OVERFLOW Computational and Experimental Results for a Blunt Mars Entry Vehicle Concept during Supersonic Retropropulsion

Simulations of unsteady supersonic retropropulsion (SRP) flow over a Hypersonic Inflatable Aerodynamic Decelerator (HIAD) blunt-body vehicle were performed using the OVERFLOW Computational Fluid Dynamics (CFD) solver. High-fidelity flow solver techniques, including Detached Eddy Simulation (DES) turbulence modeling and Adaptive Mesh Refinement (AMR), were employed to obtain improved realism in CFD predictions. Simulation conditions and geometry configurations were designed to match specific runs in the Descent System Study (DSS) wind tunnel testing (WTT) campaign. The accuracy of each simulation is assessed by direct comparison to experimental data. Comparisons of computational predictions of the SRP flowfield and bow shock shape to experimental schlieren imaging show reasonable prediction of mean shock shape, with approximately 10% similarity in shock standoff distance for selected conditions, as well as similarity in local, time-varying fluctuations of the shock-plume interaction. Comparisons of discrete measurements of surface pressure coefficient (Cp) indicate CFD accuracy within approximately 10% of the experiment across the majority of the model heatshield, with larger variations at some of the heatshield edge locations with stronger flow unsteadiness. Simulated unsteadiness of these chaotic flows, which were highly dynamic and multi-modal, was shown to be within 20-40% of experimentally-measured pressure standard deviation (SD) for the majority of the sampled locations.

Supersonic Retropropulsion↗

Stereotactic Fractionated Radiotherapy and LINAC Radiosurgery in the Treatment of Vestibular Schwannoma-Report About Both Stereotactic Methods From a Single Institution

Purpose: To evaluate tumor control and side effects associated with radiosurgery (RS) and stereotactic fractionated radiotherapy (SFR) for vestibular schwannomas (VSs) in a group of patients treated at the same institution. Methods and Materials: Between May 1997 and June 2007, 115 consecutive cases of VS were treated in our department. The SFR group (47 patients), including larger tumors (maximum diameter >1.5 cm), received a total dose of 54 Gy at 1.8 Gy per fraction. The RS group (68 patients, maximum diameter <1.5 cm) received a total dose of 12 Gy at the 100% isodose. Evaluation included serial imaging tests (magnetic resonance imaging) and neurologic and functional hearing examinations. Results: The tumor control rate was 97.9% in the SFR group for a mean follow-up time of 32.1 months and 98.5% in the RS group for a mean follow-up time of 30.1 months. Hearing function was preserved after RS in 85% of the patients and after SFR in 79%. Facial and trigeminal nerve function remained mostly unaffected after SFR. After RS, new trigeminal neuropathy occurred in 9 of 68 patients (13%). Conclusions: A high tumor control rate and low number of side effects are registered after SFR and RS of VS. These results confirm that considering tumor diameter, both RS and SFR are good treatment modalities for VS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Molecular Imaging to Predict Clinical Outcome in Patients With Rectal Cancer After Preoperative Chemotherapy and Radiation

Purpose: To correlate changes in 2-deoxy-2-[18F]fluoro-D-glucose (18-FDG) positron emission tomography (PET) (18-FDG-PET) uptake with response and disease-free survival with combined modality neoadjuvant therapy in patients with locally advanced rectal cancer. Methods and Materials: Charts were reviewed for consecutive patients with ultrasound-staged T3x to T4Nx or TxN1 rectal adenocarcinoma who underwent preoperative chemoradiation therapy at Fox Chase Cancer Center (FCCC) or Robert H. Lurie Comprehensive Cancer Center of Northwestern University with 18-FDG-PET scanning before and after combined-modality neoadjuvant chemoradiation therapy . The maximum standardized uptake value (SUV) was measured from the tumor before and 3 to 4 weeks after completion of chemoradiation therapy preoperatively. Logistic regression was used to analyze the association of pretreatment SUV, posttreatment SUV, and % SUV decrease on pathologic complete response (pCR), and a Cox model was fitted to analyze disease-free survival. Results: A total of 53 patients (FCCC, n = 41, RLCCC, n = 12) underwent pre- and postchemoradiation PET scanning between September 2000 and June 2006. The pCR rate was 31%. Univariate analysis revealed that % SUV decrease showed a marginally trend in predicting pCR (p = 0.08). In the multivariable analysis, posttreatment SUV was shown a predictor of pCR (p = 0.07), but the test results did not reach statistical significance. None of the investigated variables were predictive of disease-free survival. Conclusions: A trend was observed for % SUV decrease and posttreatment SUV predicting pCR in patients with rectal cancer treated with preoperative chemoradiation therapy. Further prospective study with a larger sample size is warranted to better characterize the role of 18-FDG-PET for response prediction in patients with rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design optimization of MR-compatible rotating anode x-ray tubes for stable operation

Purpose: Hybrid x-ray/MR systems can enhance the diagnosis and treatment of endovascular, cardiac, and neurologic disorders by using the complementary advantages of both modalities for image guidance during interventional procedures. Conventional rotating anode x-ray tubes fail near an MR imaging system, since MR fringe fields create eddy currents in the metal rotor which cause a reduction in the rotation speed of the x-ray tube motor. A new x-ray tube motor prototype has been designed and built to be operated close to a magnet. To ensure the stability and safety of the motor operation, dynamic characteristics must be analyzed to identify possible modes of mechanical failure. In this study a 3D finite element method (FEM) model was developed in order to explore possible modifications, and to optimize the motor design. The FEM provides a valuable tool that permits testing and evaluation using numerical simulation instead of building multiple prototypes.Methods: Two experimental approaches were used to measure resonance characteristics: the first obtained the angular speed curves of the x-ray tube motor employing an angle encoder; the second measured the power spectrum using a spectrum analyzer, in which the large amplitude of peaks indicates large vibrations. An estimate of the bearing stiffness is required to generate an accurate FEM model of motor operation. This stiffness depends on both the bearing geometry and adjacent structures (e.g., the number of balls, clearances, preload, etc.) in an assembly, and is therefore unknown. This parameter was set by matching the FEM results to measurements carried out with the anode attached to the motor, and verified by comparing FEM predictions and measurements with the anode removed. The validated FEM model was then used to sweep through design parameters [bearing stiffness (1×10{sup 5}–5×10{sup 7} N/m), shaft diameter (0.372–0.625 in.), rotor diameter (2.4–2.9 in.), and total length of motor (5.66–7.36 in.)] to increase the fundamental frequency past the operating range at 50 Hz.Results: The first large vibration during the prototype motor operation was obtained at 21.64±0.68 Hz in the power spectrum. An abrupt decrease in acceleration occurred at 21.5 Hz due to struggling against the resonance vibrations. A bearing stiffness of 1.2×10{sup 5} N/m in the FEM simulation was used to obtain a critical speed of 21.4 Hz providing 1.1% error. This bearing stiffness value and the 3D model were then confirmed by the experiments with the anode removed, demonstrating an agreement within 6.4% between simulation results and measurements. A calculated first critical frequency (fundamental frequency) of 68.5 Hz was obtained by increasing the bearing stiffness to 1×10{sup 7} N/m and increasing the shaft diameter by 68.0%. Reducing the number of bearings in the design permits decreasing the total length of the motor by 1.7 in., and results in a fundamental frequency of 68.3 Hz in concert with additional changes (shaft diameter of 0.625 in., rotor diameter of 2.4 in., and bearing stiffness of 1×10{sup 6} N/m).Conclusions: An FEM model of the x-ray tube motor has been implemented and experimentally validated. A fundamental frequency above the operational rotation speed can be achieved through modification of multiple design parameters, which allows the motor to operate stably and safely in the MR environment during the repeated acceleration/deceleration cycles required for an interventional procedure. The validated 3D FEM model can now be used to investigate trade-offs between generated torque, maximum speed, and motor inertia to further optimize motor design.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-189: Credentialing of IGRT Equipment and Processes for Clinical Trials

Purpose: Current dosimetry phantoms used for clinical trial credentialing do not directly assess IGRT processes. This work evaluates a custom-built IGRT phantom for credentialing of multiple IGRT modalities and processes. Methods: An IGRT phantom was built out of a low-density body with two inserts. Insert A is used for the CT simulation. Insert B is used for the actual treatment. The inserts contain identical targets in different locations. Relative positions are unknown to the user. The user simulates the phantom (with insert A) as they would a patient, including marking the phantom. A treatment plan is created and sent to the treatment unit. The phantom (with insert B) is then positioned using local IGRT practice. Shifts (planned isocenter, if applicable, and final isocenter) are marked on the phantom using room lasers. The mechanical reproducibility of re-inserting the inserts within the phantom body was tested using repeat high-resolution CT scans. The phantom was tested at 7 centers, selected to include a wide variety of imaging equipment. Results: Mechanical reproducibility was measured as 0.5-0.9mm, depending on the direction. Approaches tested to mark (and transfer) simulation isocenter included lasers, fiducials and reflective markers. IGRT approaches included kV imaging (Varian Trilogy, Brainlab ExacTrac), kV CT (CT-on-rails), kV CBCT (Varian Trilogy, Varian Truebeam, Elekta Agility) and MV CT (Tomotherapy). Users were able to successfully use this phantom for all combinations of equipment and processes. IGRT-based shifts agreed with the truth within 0.8mm, 0.8mm and 1.9mm in the LR, AP, and SI directions, respectively. Conclusion: Based on these preliminary results, the IGRT phantom can be used for credentialing of clinical trials with an action level of 1mm in AP and LR directions, and 2mm in the SI direction, consistent with TG142. We are currently testing with additional institutions with different equipment and processes, including Cyberknife. This project was funded by the Cancer Prevention Research Institute of Texas.

60 APPLIED LIFE SCIENCES↗

Transonic flutter study of a wind-tunnel model of an arrow-wing supersonic transport

A 1/20-size, low-speed flutter model of the SCAT-15F complete airplane was tested in a wind-tunnel on cables to simulate a near free-flying condition. Only the model wing and fuselage were flexible. Flutter boundaries were measured for a nominal configuration and a configuration with wing fins removed at Mach numbers M from 0.76 to 1.2. For both configurations, the transonic dip in the wing flutter dynamic pressure q boundary was relatively small and the minimum flutter q occurred near M = 0.92. Removing the wing fins increased the flutter q about 14 percent and changed the flutter mode from symmetric to antisymmetric. Vibration and flutter analyses were made using a finite-element structural representation and subsonic kernel-function aerodynamics. For the nominal configuration, the analysis (using calculated modal data) predicted the experimental flutter q levels within 10 percent but did not predict the correct flutter mode at the higher M. For the configuration without wing fins, the analysis predicted 16 to 36 percent unconservative (higher than experimental) flutter q levels and showed extreme sensitivity to mass shapes.

Ruhlin, C. L.↗

Trabecular Bone Mechanical Properties and Fractal Dimension

Countermeasures for reducing bone loss and muscle atrophy due to extended exposure to the microgravity environment of space are continuing to be developed and improved. An important component of this effort is finite element modeling of the lower extremity and spinal column. These models will permit analysis and evaluation specific to each individual and thereby provide more efficient and effective exercise protocols. Inflight countermeasures and post-flight rehabilitation can then be customized and targeted on a case-by-case basis. Recent Summer Faculty Fellowship participants have focused upon finite element mesh generation, muscle force estimation, and fractal calculations of trabecular bone microstructure. Methods have been developed for generating the three-dimensional geometry of the femur from serial section magnetic resonance images (MRI). The use of MRI as an imaging modality avoids excessive exposure to radiation associated with X-ray based methods. These images can also detect trabecular bone microstructure and architecture. The goal of the current research is to determine the degree to which the fractal dimension of trabecular architecture can be used to predict the mechanical properties of trabecular bone tissue. The elastic modulus and the ultimate strength (or strain) can then be estimated from non-invasive, non-radiating imaging and incorporated into the finite element models to more accurately represent the bone tissue of each individual of interest. Trabecular bone specimens from the proximal tibia are being studied in this first phase of the work. Detailed protocols and procedures have been developed for carrying test specimens through all of the steps of a multi-faceted test program. The test program begins with MRI and X-ray imaging of the whole bones before excising a smaller workpiece from the proximal tibia region. High resolution MRI scans are then made and the piece further cut into slabs (roughly 1 cm thick). The slabs are X-rayed again and also scanned using dual-energy X-ray absorptiometry (DEXA). Cube specimens are then cut from the slabs and tested mechanically in compression. Correlations between mechanical properties and fractal dimension will then be examined to assess and quantify the predictive capability of the fractal calculations.

Hogan, Harry A.↗

Use of Modal Acoustic Emission to Monitor Damage Progression in Carbon Fiber/Epoxy and Implications for Composite Structures

Broad-band modal acoustic emission (AE) data was used to characterize micromechanical damage progression in uniaxial IM7 and T1000 carbon fiber-epoxy tows and an IM7 composite overwrapped pressure vessel (COPV) subjected to an intermittent load hold tensile stress profile known to activate the Felicity ratio (FR). Damage progression was followed by inspecting the Fast Fourier Transforms (FFTs) associated with acoustic emission events. FFT analysis revealed the occurrence of cooperative micromechanical damage events in a frequency range between 100 kHz and 1 MHz. Evidence was found for the existence of a universal damage parameter, referred to here as the critical Felicity ratio, or Felicity ratio at rupture (FR*), which had a value close to 0.96 for the tows and the COPV tested. The implications of using FR* to predict failure in carbon/epoxy composite materials and related composite components such as COPVs are discussed. Trends in the FFT data are also discussed; namely, the difference between the low and high energy events, the difference between early and late-life events, comparison of IM7 and T1000 damage progression, and lastly, the similarity of events occurring at the onset of significant acoustic emission used to calculate the FR.

Waller, J. M.↗

TriTruss Packaging and Deployment Trade Study

A trade study was conducted that evaluated viable concepts of operation for the packaging and deployment (P&D) of novel deployable modular truss modules, called TriTruss modules, that can be assembled to form a large aperture In-Space Assembled Telescopes (iSAT). In this first phase of an ongoing more comprehensive trade study, concepts were proposed and then evaluated based on initial metrics representing features of an ideal P&D concept. The ideal TriTruss P&D concept is defined as one that: allows for efficient packaging, has sufficient geometric versatility to be launch vehicle independent, provides a stiff and lightweight structure, has low mechanical complexity, and has component modularity. The P&D concept should allow for prelaunch subsystem or utility integration if required. The concept should be kinematically simple and be robotically deployed using a minimum number of specialized tools. The P&D concepts evaluated are categorized as: core collapse, face collapse, and erectable structures. Sub-scale models were constructed to help understand the kinematics and mechanical complexity required to enable P&D. Based on a weighting scale, the most promising candidate P&D concepts have been selected and will undergo more rigorous structural design, analysis, and testing in the study’s next phase. The ultimate goal of the comprehensive trade study will be to recommend a single TriTruss design and associated P&D concept that will be built and evaluated at NASA Langley Research Center’s In-Space Assembly Laboratory.

in-space assembly (ISA)↗

Vibration characteristics of Z-ring-stiffened 60 deg conical shell models of a planetary entry spacecraft

An experimental investigation of the vibration characteristics of a 60 deg conical shell model of a planetary entry vehicle is described and the results presented. Model configurations include the shell with or without one or two Z-ring stiffeners and with or without a simulated payload. Tests were conducted with the model clamped at the small diameter and with the model suspended at the simulated payload. Additionally, calculated results obtained from application of several analytical procedures reported in the literature are presented together with comparisons between experimental and calculated frequencies and meridional mode shapes. Generally, very good frequency agreement between experimental and calculated results was obtained for all model configurations. For small values of circumferential mode number, however, the frequency agreement decreased as the number of ring stiffeners increased. Overall agreement between experimental and calculated mode shapes was generally good. The calculated modes usually showed much larger curvatures in the vicinity of the rings than were observed in the experimentally measured mode shapes. Dual resonances associated with modal preference were noted for the shell without Z-ring stiffeners, whereas the addition of stiffeners produced resonances for which the model responded in two or more modes over different sections of the shell length.

Naumann, E. C.↗