An Investigation of the Flame-Burden Interaction during Remelting in an Experimental Aluminum Reverbatory Furnace

Flame impingement on the burden is routinely encountered during the initial phase of melting in aluminum reverberatory furnaces. This impingement causes an obstructed pathway for the hot gases, and hence the circulation and residence time of the hot gases are greatly impacted. Moreover, as the load melts, the flames gradually achieve an unobstructed path leading to reduced gas residence times. This flame impingement and constantly changing combustion space volume will lead to vastly different fuel and oxidizer mixing patterns and thus affect the overall furnace performance. Fine tuning the burner operating conditions such as flow rates and injection angles with the changing combustion space could result in significant improvements to the furnace efficiency. However, one has to gain a better understanding of the furnace dynamics to know the suitable parameters to adjust. Physical modeling can be elaborate and expensive to conduct on a regular basis while Computational Fluid Dynamics (CFD) can cost-effectively address this challenge. In this study, the furnace model is created with a particular loading pattern to understand the flame dynamics in the presence of a piled load. This configuration can be thought of as a computational model of the furnace with the burden at a particular stage of the melting process. Thermal efficiency and behavior of the furnace are quantified and the predicted values are compared with the operational data from an experimental reverberatory furnace.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a metamodelling framework for building energy models with application to fifth-generation district heating and cooling networks

Fully defined physics-based building energy models can accurately represent building systems; however, generating models based on high-level parameters is time consuming and simulation time of complex models can be slow. This article discusses the development of a Metamodelling Framework to create metamodels from a building energy modelling dataset. The framework generates metamodels using either linear regression, random forests, or support vector regressions. A fifth-generation district heating and cooling system analysis use case was used to motivate the development of the framework. The use case required quick and accurate representations of annual building loads reported hourly. Typical annual building modelling approaches can result in a runtime of 10 min. The metamodels runtime was reduced to less than 10 s to load and run an annual simulation with user-defined covariates. The results of the metamodel performance and an abbreviated topology analysis based on the motivating use case will be presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-term apartment-level load forecasting using a modified neural network with selected auto-regressive features

Residential electricity load profiles and their diversity have become increasingly important to realize the benefits of Smart or Transactive Energy Networks (TENs). An important element of TENs will be practical, accurate, and implementable residential load forecasting techniques. While there have been many approaches to short-term load forecasting, few have included forecasting for individual households, partly because the high volatility and idiosyncrasies present in individual household load data can pose significant challenges. In this study, we develop a Convolutional Long Short-Term Memory-based neural network with Selected Autoregressive Features (termed a CLSAF model) to improve short-term household electricity load forecasting accuracy by employing three strategies: autoregressive features selection, exogenous features selection, and a “default” state to avoid overfitting at times of high load volatility. We include aggregations of apartments to floor and building level, because utilities may favor transactive approaches that rely on aggregator models, e.g., a cluster of consumers as opposed to an individual. We demonstrate that the CLSAF model, by virtue of its enhanced feature representation and modest computational resources, can accomplish load forecasting in a multi-family residential building across three spatial granularities (individual apartment/household, floor, and building levels), with an accuracy improvement of up to 25% compared to a persistence model. We propose a data screening technique to characterize time-series electricity-load data. This technique is suitable for integration into a TEN ecosystem and allows one to estimate confidence levels of the load forecasts to optimize computational resources and the risks associated with uncertain forecasts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Models of SIV rebound after treatment interruption that involve multiple reactivation events

In order to assess the efficacy of novel HIV-1 treatments leading to a functional cure, the time to viral rebound is frequently used as a surrogate endpoint. The longer the time to viral rebound, the more efficacious the therapy. In support of such an approach, mathematical models serve as a connection between the size of the latent reservoir and the time to HIV-1 rebound after treatment interruption. The simplest of such models assumes that a single successful latent cell reactivation event leads to observable viremia after a period of exponential viral growth. Here we consider a generalization developed by Pinkevych et al. and Hill et al. of this simple model in which multiple reactivation events can occur, each contributing to the exponential growth of the viral load. We formalize and improve the previous derivation of the dynamics predicted by this model, and use the model to estimate relevant biological parameters from SIV rebound data. We confirm a previously described effect of very early antiretroviral therapy (ART) initiation on the rate of recrudescence and the viral load growth rate after treatment interruption. We find that every day ART initiation is delayed results in a 39% increase in the recrudescence rate (95% credible interval: [18%, 62%]), and a 11% decrease of the viral growth rate (95% credible interval: [4%, 20%]). We show that when viral rebound occurs early relative to the viral load doubling time, a model with multiple successful reactivation events fits the data better than a model with only a single successful reactivation event.

59 BASIC BIOLOGICAL SCIENCES↗

Predicted Impacts of Pt and Ionomer Distributions on Low-Pt-Loaded PEMFC Performance

Low-cost, high performance proton exchange membrane fuel cells (PEMFCs) have been difficult to develop due to limited understanding of coupled processes in the cathode catalyst layer (CCL). Low-Pt-loaded PEMFCs suffer losses beyond those predicted solely due to reduced catalyst area. Although consensus links these losses to thin ionomer films in the CCL, a precise mechanistic explanation remains elusive. In this publication, we present a physically based PEMFC model with novel structure-property relationships for thin-film Nafion, validated against PEMFC data with low Pt loading. Results suggest that flooding exacerbates kinetic limitations in low-loaded PEMFCs, shifting the Faradaic current distribution. As current density increases, protons travel further into the CCL, resulting in higher Ohmic overpotentials. We also present a parametric study of CCL design parameters. We find that graded Pt and ionomer loadings reduce Ohmic losses and flooding, but individually do not provide significant improvements. However, a dual-graded CCL (i.e., graded Pt and ionomer) is predicted to significantly improve the maximum power density and limiting current compared to uniformly loaded CCLs. This work highlights the importance of accurate transport parameters for thin-film Nafion and provides a pathway to low-cost PEMFCs via precise control of CCL microstructures.

08 HYDROGEN↗

Modeling HCV cure after an ultra-short duration of therapy with direct acting agents

In cases of sustained-virological response (SVR or cure) after an ultra-short duration (≤ 27 days) of direct-acting antiviral (DAA)-based therapy, despite HCV being detected at end of treatment (EOT), have been reported. Established HCV mathematical models that predict the treatment duration required to achieve cure do not take into account the possibility that the infectivity of virus produced during treatment might be reduced. The aim of this study was to develop a new mathematical model that considers the fundamental and critical concept that HCV RNA in serum represents both infectious virus (V i ) and non-infectious virus (V ni ) in order to explain the observation of cure with ultrashort DAA therapy. Established HCV models were compared to the new mathematical model to retrospectively explain cure in 2 patients who achieved cure after 24 or 27 days of paritaprevir, ombitasvir, dasabuvir, ritonavir and ribavirin or sofosbuvir plus ribavirin, respectively. Fitting established models with measured longitudinal HCV viral loads indicated that in both cases, cure would not have been expected without an additional 3–6 weeks of therapy after the actual EOT. In contrast, the new model fits the observed outcome by considering that in addition to blocking V i and V ni production (ε~0.998), these DAA + ribavirin treatments further enhanced the ratio of V ni to V i , thus increasing the log (V ni /V i ) from 1 at pretreatment to 6 by EOT, which led to <1 infectious-virus particle in the extracellular body fluid (i.e., cure) prior to EOT. This new model can explain cure after short duration of DAA + ribavirin therapy by suggesting that a minimum 6-fold increase of log (V ni /V i ) results from drug-induced enhancement of the V ni /V i .

59 BASIC BIOLOGICAL SCIENCES↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

Computation of probabilistic hazard maps and source parameter estimation for volcanic ash transport and dispersion

Volcanic ash advisory centers are charged with forecasting the movement of volcanic ash plumes, for aviation, health and safety preparation. Deterministic mathematical equations model the advection and dispersion of these plumes. However initial plume conditions – height, profile of particle location, volcanic vent parameters – are known only approximately at best, and other features of the governing system such as the windfield are stochastic. These uncertainties make forecasting plume motion difficult. As a result of these uncertainties, ash advisories based on a deterministic approach tend to be conservative, and many times over/under estimate the extent of a plume. This paper presents an end-to-end framework for generating a probabilistic approach to ash plume forecasting. This framework uses an ensemble of solutions, guided by Conjugate Unscented Transform (CUT) method for evaluating expectation integrals. This ensemble is used to construct a polynomial chaos expansion that can be sampled cheaply, to provide a probabilistic model forecast. The CUT method is then combined with a minimum variance condition, to provide a full posterior pdf of the uncertain source parameters, based on observed satellite imagery. The April 2010 eruption of the Eyjafjallajökull volcano in Iceland is employed as a test example. The puff advection/dispersion model is used to hindcast the motion of the ash plume through time, concentrating on the period 14–16 April 2010. Variability in the height and particle loading of that eruption is introduced through a volcano column model called bent. Output uncertainty due to the assumed uncertain input parameter probability distributions, and a probabilistic spatial-temporal estimate of ash presence are computed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Demand Response Resource Quantification with Detailed Building Energy Models

Demand response is a broad suite of technologies that enables changes in electrical load operations in support of power system reliability and efficiency. Although demand response is not a new concept, there is new appetite for comprehensively evaluating its technical potential in the context of renewable energy integration. The complexity of demand response makes this task difficult -- we present new methods for capturing the heterogeneity of potential responses from buildings, their time-varying nature, and metrics such as thermal comfort that help quantify likely acceptability of specific demand response actions. Computed with an automated software framework, the methods are scalable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Method for Modeling Creep-Fatigue Stress- Strain Behavior Using Neural ODEs

In this paper, we introduce a data-driven machine learning approach for modeling one-dimensional stress–strain behavior under cyclic loading, utilizing experimental data from the nickel-based Alloy 617. The study employs uniaxial creep–fatigue test data acquired under various loading histories and compares two distinct neural network-based ODE models. The first model, known as the black-box model, comprehensively describes the strain–stress relationship using a Neural ODE equation. To interpret this black-box model, we apply the Sparse Identification of Nonlinear Dynamical Systems (SINDy) technique, transforming the black-box model into an equation-based model using symbolic regression. The second model, the Neural flow rule model, incorporates Hooke’s Law for the linear elastic component, with the nonlinear part characterized by a Neural ODE. Both models are trained with experimental data to accurately reflect the observed stress–strain behavior. We conduct a detailed comparison with the standard Chaboche model, which includes three back stresses. Our results demonstrate that the neural network-based ODE models precisely capture the experimental creep–fatigue mechanical behavior, exceeding the standard Chaboche model’s accuracy. Furthermore, an interpretable model derived from the black-box neural ODE model through symbolic regression achieves accuracy comparable to the Chaboche model, enhancing its interpretability. The results highlight the potential of neural network-based ODE models to depict complex creep–fatigue behavior, eliminating the necessity for experts to define a specific, material-focused model form.

creep-fatigue↗

Observational constraint on cloud susceptibility weakened by aerosol retrieval limitations

Aerosol-cloud interactions remain a major uncertainty in climate research. Studies have indicated that model estimates of cloud susceptibility to aerosols frequently exceed satellite estimates, motivating model reformulations to increase agreement. Here we show that conventional ways of using satellite information to estimate susceptibility can serve as only a weak constraint on models because the estimation is sensitive to errors in the retrieval procedures. Using instrument simulators to investigate differences between model and satellite estimates of susceptibilities, we find that low aerosol loading conditions are not well characterized by satellites, but model clouds are sensitive to aerosol perturbations in these conditions. We quantify the observational requirements needed to constrain models, and find that the nighttime lidar measurements of aerosols provide a better characterization of tenuous aerosols. Here, we conclude that observational uncertainties and limitations need to be accounted for when assessing the role of aerosols in the climate system.

54 ENVIRONMENTAL SCIENCES↗

Photos of Lansmont PDT 80 drop test machine at Los Alamos

The Los Alamos RP-SVS Radiation Protection Services group designed and constructed a drop tower facility for TA- 55 support work. The drop mechanism was supplied by the Lansmont company in Monterey CA. Los Alamos staffers Murray Moore and Yong Tao have noticed that the system is not dropping loads correctly, and they have photographed aspects of the PDT- 80 model system. The first 10 photos show the platen loaded with a cylindrical steel bar. The next 10 photos are of the roller-cam mechanism in the drop tower, and the last 2 photos indicate the amount of looseness in the platen when it is being pulled by a person.

47 OTHER INSTRUMENTATION↗

REopt Model Overview and Example Use Cases [Slides]

REopt(R) is a mixed-integer optimization model that minimizes the lifecycle cost of serving energy loads at a site. This work provides and introduction to the model along with its key workflow, techno-economic inputs, key outputs, and key caveats for readers to understand REopt the when, why, how of using this model. This resource also includes helpful links related to REopt model and the data sources it uses during the optimization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ADVANCED THERMAL-HYDRAULIC MODEL OF HEAT RECOVERY STEAM GENERATORS

Steam-side oxidation at elevated temperatures in heat recovery steam generators (HRSGs) can lead to overheating of local tubes, potential oxide scale exfoliation, and damage to critical equipment. Predicting the oxide growth distribution requires detailed knowledge of the distribution of tube metal temperatures. To address these challenges, a computational fluid dynamics (CFD) model of a high-pressure superheater (HPSH) was developed within the Siemens’ STAR-CCM+ CFD commercial software. The HPSH section of the steam generator was selected for modeling because of its high oxidation rates.The model development included several steps. In the first step, an oxidation model based on a parabolic oxidation relationship was implemented. The oxidation growth predicted by the model was then verified for a full-load boiler operation case. In the second step, a three-dimensional CFD model was developed to account for the thermal and flow physics involved in HRSGs. The CFD model was then verified and validated on a simplified geometry that contained six row-tubes which mimicked the tube arrangements of an HPSH section. Numerical results compared well with published experimental results. In the third step, the oxidation model was coupled to the HRSG’s CFD model, and a comparison study was performed for two cases: (a) regular finless tubes and (b) finned tubes. Preliminary results showed that the oxide thickness predicted by the case with tube fins was higher compared to that of the finless tube case, thus demonstrating the need to model the effects of the tube fins on oxide thickness.

Panicker, Nithin↗

Simulations of Lithium-Based Neutron Coincidence Counter for Gd-Loaded Fuel

The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Lithium-Based Alternative Neutron Detection Technology Coincidence Counting for Gd-loaded Fuels at Pacific Northwest National Laboratory for the development of a lithium-based neutron coincidence counter for nondestructively assaying Gd loaded nuclear fuel. This report provides results from MCNP simulations of a lithium-based coincidence counter for the possible measurement of Gd-loaded nuclear fuel. A comparison of lithium-based simulations and UNCL-II simulations with and without Gd loaded fuel is provided. A lithium-based model, referred to as PLNS3A-R1, showed strong promise for assaying Gd loaded fuel.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗