Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installation tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Introduction to MDSplus using Docker

With increased use of MDSplus comes an influx of new users. With them comes a need for more and better ways to learn the suite of tools that is MDSplus. Therefore, the MDSplus team continually evaluates new technologies to improve our software and user experience. To this end, we investigated Docker to determine if and how it could help new users understand MDSplus, make MDSplus easier to install, and allow us to easily test old/new versions. To achieve this, a set of Docker images and instructions have been developed. This paper will provide an overview of MDSplus, and detail the methods to create and use the Docker images. Additionally, we will explore the limitations of such an approach, and the recommended applications. The project where these Docker Images were built, along with the Demo is here: https://github.com/WhoBrokeTheBuild/DockerizedMDSplus https://hub.docker.com/r/whobrokethebuild/mdsplus The now official Docker Images are available here: https://github.com/MDSplus/Docker https://hub.docker.com/r/mdsplus/mdsplus

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relative Gain Monitoring of the GlueX Calorimeters

The relative gain of the photodetectors for the GlueX Barrel and Forward calorimeters will be monitored using modular LED driver systems. The BCAL system consists of a global controller that feeds power, bias voltage and trigger signals to 96 local controllers situated at the ends of the 48 BCAL modules, which drive 40 LEDs associated with the 40 light guides at the end of each module. The FCAL system consists also of a global controller, a local controller for each acrylic quadrant covering the face of the FCAL, and ten 4-LED pulser boards per local controller connected in a star configuration along the edges of the acrylic panes. The respective systems are currently being installed on the detectors and their tested performance is presented herein.

43 PARTICLE ACCELERATORS↗

Polarization Facilities at COSY

The cooler synchrotron COSY at the Forschungszentrum Juelich, Germany has been equipped with all necessary tools to accelerate polarized protons and deuterons to their maximum energy. For the EDDA and ANKE experiments two atomic beam targets for polarized protons and deuterons have been installed in the COSY-ring. Tests of the RF Spin-Flipper have been very successful. Externally polarization experiments are carried out by the TOF spectrometer. The performance of the relevant components and experiments is discussed.

43 PARTICLE ACCELERATORS↗

High-Resolution X-ray Microprobe Using a Spatial Filter and Its Application to Micro-XAFS Measurements

An x-ray microprobe system with total-reflection mirror optics for trace element analysis has been developed at beamline 37XU of SPring-8. To achieve sub-microprobe, a spatial filter has been installed downstream of a monochromator. Focusing tests have been performed in the x-ray energy range of 6-14 keV. A focused beam size of 0.83 {mu}m(V)x1.35 {mu}m(H) has been obtained at an x-ray energy of 10 keV, and using a spatial filter in the horizontal direction, the beam size is down to 0.84 {mu}m. Micro-x-ray absorption fine structure (XAFS) spectroscopy of submicrometer particles has been done by utilizing the total-reflection mirror optics. It was clearly observed from the nickel K-edge XAFS spectra that the oxidation state of nickel was a mixture of metal and oxide even in the single submicrometer particle.

07 ISOTOPE AND RADIATION SOURCES↗

Properties of convective cells generated in magnetized toroidal plasmas

Convective cells for turbulence control, generated by means of biased electrodes, are investigated in the simple magnetized toroidal plasmas of TORPEX. A two-dimensional array of 24 electrodes is installed on a metal limiter to test different biasing schemes. This allows influencing significantly both radial and vertical blob velocities. It is shown that these changes agree quantitatively with the flows deduced from the time averaged potential perturbations induced by the biasing. Detailed measurements along and across the magnetic field provide a rather clear picture of the effect of biasing on time averaged profiles. The biased electrodes produce perturbations of the plasma potential and density profiles that are fairly uniform along the magnetic field. Background flows influence the location where potential variations are induced. The magnitude of the achievable potential variations in the plasma is strongly limited by cross-field currents and saturates at large bias voltages once the electrodes draw electron saturation current. A quantitative discussion on the origin of cross-field currents is presented, considering contributions related with diamagnetic drifts, ion inertia, collisions with neutrals, and viscosity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status and operation of the Linac4 ion source prototypes

CERN's Linac4 45 kV H{sup −} ion sources prototypes are installed at a dedicated ion source test stand and in the Linac4 tunnel. The operation of the pulsed hydrogen injection, RF sustained plasma, and pulsed high voltages are described. The first experimental results of two prototypes relying on 2 MHz RF-plasma heating are presented. The plasma is ignited via capacitive coupling, and sustained by inductive coupling. The light emitted from the plasma is collected by viewports pointing to the plasma chamber wall in the middle of the RF solenoid and to the plasma chamber axis. Preliminary measurements of optical emission spectroscopy and photometry of the plasma have been performed. The design of a cesiated ion source is presented. The volume source has produced a 45 keV H{sup −} beam of 16–22 mA which has successfully been used for the commissioning of the Low Energy Beam Transport (LEBT), Radio Frequency Quadrupole (RFQ) accelerator, and chopper of Linac4.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status of the ESS cryogenic system

The European Spallation Source (ESS) is a neutron science facility funded by a collaboration of 17 European countries currently under design and construction in Lund, Sweden. The centerpiece of ESS is a 2.5 GeV proton linac utilizing superconducting RF cavities operating at 2 K. In addition to cooling the SRF cavities, cryogenics is also used at ESS in the liquid hydrogen moderators surrounding the target. ESS also uses both liquid helium and liquid nitrogen in a number of the planned neutron instruments. There is also a significant cryogenic installation associated with the site acceptance testing of the ESS cryomodules. The ESS cryogenic system consists of 3 separate helium refrigeration/liquefaction plants supplying the accelerator, target moderators and instruments. An extensive cryogenic distribution system connects the accelerator cryoplant with the cryomodules. This paper describes the preliminary design of the ESS cryogenic system including the expected heat loads. Challenges associated with the required high reliability and turn-down capability will also be discussed. A unique feature of ESS is its commitment to sustainability and energy recovery. A conceptual design for recovering waste heat from the helium compressors for use in the Lund district heating system will also be described.

43 PARTICLE ACCELERATORS↗

Bringing Automated Fault Detection and Diagnostics Tools for HVAC&R Into the Mainstream

Heating, ventilation, and air-conditioning (HVAC) systems consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. commercial buildings. Additionally, commercial refrigeration (R) systems add about 1 quad to commercial buildings energy consumption. Most HVAC systems operate with one or more faults that result in increased energy consumption. Fault detection and diagnostics (FDD) tools have been developed to address this national issue, and many tools are commercially available. FDD tools have the potential to save considerable energy for an existing commercial rooftop unit (RTU) and refrigeration systems. These devices can be used for both retro commissioning and, when faults are addressed, continuous commissioning. However, there appears to be multiple market barriers for this technology. Although there are efforts to develop FDD tool standards, currently there are no standards and methods to define functions, capabilities, accuracy, and reliability of FDD tools in the field. Moreover, most of the commercial FDD tools have not been verified in the field independently. This paper presents a comprehensive approach for bringing HVAC FDD tools into the mainstream. The approach involves demonstrating ten commercially available FDD tools installed at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying and assessing market barriers, creating a process evaluation methodology, and assisting utility companies in developing incentive programs. Furthermore, the preliminary baseline results from the case study demonstrate how the use of an independent monitoring system (IMS) can be used for ground-truth in evaluating FDD tools in the field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

NEMA NU 2-2012 performance studies for the SiPM-based ToF-PET component of the GE SIGNA PET/MR system

Purpose: The GE SIGNA PET/MR is a new whole body integrated time-of-flight (ToF)-PET/MR scanner from GE Healthcare. The system is capable of simultaneous PET and MR image acquisition with sub-400 ps coincidence time resolution. Simultaneous PET/MR holds great potential as a method of interrogating molecular, functional, and anatomical parameters in clinical disease in one study. Despite the complementary imaging capabilities of PET and MRI, their respective hardware tends to be incompatible due to mutual interference. In this work, the GE SIGNA PET/MR is evaluated in terms of PET performance and the potential effects of interference from MRI operation. Methods: The NEMA NU 2-2012 protocol was followed to measure PET performance parameters including spatial resolution, noise equivalent count rate, sensitivity, accuracy, and image quality. Each of these tests was performed both with the MR subsystem idle and with continuous MR pulsing for the duration of the PET data acquisition. Most measurements were repeated at three separate test sites where the system is installed. Results: The scanner has achieved an average of 4.4, 4.1, and 5.3 mm full width at half maximum radial, tangential, and axial spatial resolutions, respectively, at 1 cm from the transaxial FOV center. The peak noise equivalent count rate (NECR) of 218 kcps and a scatter fraction of 43.6% are reached at an activity concentration of 17.8 kBq/ml. Sensitivity at the center position is 23.3 cps/kBq. The maximum relative slice count rate error below peak NECR was 3.3%, and the residual error from attenuation and scatter corrections was 3.6%. Continuous MR pulsing had either no effect or a minor effect on each measurement. Conclusions: Performance measurements of the ToF-PET whole body GE SIGNA PET/MR system indicate that it is a promising new simultaneous imaging platform.

60 APPLIED LIFE SCIENCES↗

Experiences with Porting the FLASH Code to Ookami, an HPE Apollo 80 A64FX Platform

We present initial experiences with running the community simulation code FLASH, developed at the University of Chicago for multi-scale multi-physics applications, on Ookami, a technology testbed featuring the A64FX processor developed by Fujitsu. Our effort focused largely on running FLASH “right out of the box” to see which combinations of compilers and software implementations (e.g. MPI) allowed the code to run with minimal modification. FLASH was one application in a larger effort to deploy Ookami; it served as a test for different versions of newly installed software, and as a cornerstone for the FAQ page of the Ookami website. Here, we report on our results with different compilers and other software, along with our initial scaling results and attempts to utilize the A64FX’s SVE instructions and NUMA architecture. We found that FLASH readily ran with different compilers and MPI implementations, and showed the expected good scaling with no turning. However, more work must be done to fully take advantage of the A64FX’s architectural features and produce a significant speedup for FLASH on Ookami.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of Nb3Sn multicell cavity coatings

Nb3Sn films have the potential to replace niobium in SRF cavities. Besides single-cell cavity efforts to improve Nb3Sn films, we are working to replicate single-cell results onto the practical 5-cell CEBAF cavities. High quality factors (10E11 @ 2.0K and 10E10 @ 4.3 K) have been measured, but the cavities are typically limited by strong low-field Q-slopes and quenches. Two of the cavities were selected to be assembled into a "mock-up" cavity string unit, the standard step before installation into a cryomodule. Comparison of test results between VTA and pair test offered the first glimpse into post-processing effects on the cavity performance.

Eremeev, G.↗

Progress towards Nb3Sn CEBAF Injector Cryomodule

Operations at 4 K instead of 2 K have the potential to reduce the operational cost of an SRF linac by a factor of 3, if the cavity quality factor can be maintained. Cavities coated with Nb3Sn have been shown to achieve the accelerating gradients above 10 MV/m with a quality factor around 1010 at 4 K. Because such performance is already pertinent for CEBAF injector cryomodule, we are working to extend these results to CEBAF accelerator cavities envisioning coating of two CEBAF 5-cell cavities with Nb3Sn. They will be installed in an injector cryomodule and tested with beam. The progress on this path is reported in this contribution.

Eremeev, Grigory↗

Corrective Action Plan for Corrective Action Unit 568: Area 3 Plutonium Dispersion Sites Nevada National Security Site, Nevada, Revision 0 with ROTC 1

The purpose of this CAP is to provide the plan for implementation of the recommended corrective action alternatives (CAAs) for CAU 568. Site characterization activities were performed in 2014, and the results are presented in Appendix A of the CAU 568 CADD. The CAAs were recommended in the CADD. The scope of work required to implement the recommended CAAs of closure in place and clean closure at 11 of the 14 CASs includes the following: The installation of physical barriers over the nine safety experiment ground zeroes to cover contamination at CASs 03-23-20 (Otero), 03-23-23 (San Juan and Pascal-C), 03-23-31 (Pascal-B, Luna, Colfax), 03-23-32 (Pascal-A), 03-23-33 (Valencia), and 03-23-34 (Chipmunk); the characterization and removal of three soil and debris piles at CAS 03-08-04, and one HCA soil pile at CAS 03-23-30; the removal of three steel well head covers (PSM) from CASs 03-23-20 (Otero), 03-23-31 (Luna), and 03-23-33 (Valencia); the removal of soil and lead PSM from two locations at CAS 03-26-04; Implementation of FFACO use restrictions at nine safety experiment ground zeroes at CASs 03-23-20, 03-23-23, 03-23-31, 03-23-32, 03-23-33, and 03-23-34; the steel well head cover at CAS 03-23-23; the areas meeting HCA conditions at CASs 03-23-19 and 03-23-31; and the Boomer crater area at CAS 03-45-01. The FFACO use restriction boundaries will be presented in the CAU 568 closure report.

54 ENVIRONMENTAL SCIENCES↗

Statement of Work Electrical Energy Storage System Installation at Sandia National Laboratories.

Sandia is seeking to procure a 1 MWh energy storage system. It will be installed at the existing Energy Storage Test Pad, which is located at Sandia National Laboratories in Albuquerque, New Mexico. This energy storage system will be a daily operational system, but will also be used as a tool in our Research and development work. The system will be part of a showcase of Sandia distributed energy technologies viewed by many distinguished delegates.

25 ENERGY STORAGE↗

Preliminary Assessment of Two Alternative Core Design Concepts for the Special Purpose Reactor

The Special Purpose Reactor (SPR) is a small 5 MWt, heat pipe-cooled, fast reactor based on the Los Alamos National Laboratory (LANL) Mega-Power concept. The LANL concept features a stainless steel monolithic core structure with drilled channels for UO2 pellet stacks and evaporator sections of the heat pipes. Two alternative active core designs are presented here that replace the monolithic core structure with simpler and easier to manufacture fuel elements. The two new core designs are simply referred to as Design A and Design B. In addition to ease of manufacturability, the fuel elements for both Design A and Design B can be individually fabricated, assembled, inspected, tested, and qualified prior to their installation into the reactor core leading to greater reactor system reliability and safety. Design A fuel elements will require the development of a new hexagonally-shaped UO2 fuel pellet. The Design A configuration will consist of an array of hexagonally-shaped fuel elements with each fuel element having a central heat pipe. This hexagonal fuel element configuration results in four radial gaps or thermal resistances per element. Neither the fuel element development, nor the radial gap issue are deemed to be serious and should not impact an aggressive reactor deployment schedule. Design B uses embedded arrays of heat pipes and fuel pins in a double-wall tank filled with liquid metal sodium. Sodium is used to thermally bond the heat pipes to the fuel pins, but its usage may create reactor transportation and regulatory challenges. An independent panel of U.S. manufacturing experts has preliminarily assessed the three SPR core designs and views Design A as simplest to manufacture. Herein are the results of a preliminary neutronic, thermal, mechanical, material, and manufacturing assessment of both Design A and Design B along with comparisons to the LANL concept (monolithic core structure). Despite the active core differences, all three reactor concepts behave similarly and retain the same ex-core features and characteristics. While INL has developed Designs A and B, LANL is evaluating a Hot Isostatic Pressed reactor configuration to overcome the drawbacks of the monolithic core design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Assessment of Two Alternative Core Design Concepts for the Special Purpose Reactor

The Special Purpose Reactor (SPR) is a small 5 MWt, heat pipe-cooled, fast reactor based on the Los Alamos National Laboratory (LANL) Mega-Power concept. The LANL concept features a stainless steel monolithic core structure with drilled channels for UO 2 pellet stacks and evaporator sections of the heat pipes. Two alternative active core designs are presented here that replace the monolithic core structure with simpler and easier to manufacture fuel elements. The two new core designs are simply referred to as Design A and Design B. In addition to ease of manufacturability, the fuel elements for both Design A and Design B can be individually fabricated, assembled, inspected, tested, and qualified prior to their installation into the reactor core leading to greater reactor system reliability and safety. Design A fuel elements will require the development of a new hexagonally-shaped UO 2 fuel pellet. The Design A configuration will consist of an array of hexagonally-shaped fuel elements with each fuel element having a central heat pipe. This hexagonal fuel element configuration results in four radial gaps or thermal resistances per element. Neither the fuel element development, nor the radial gap issue are deemed to be serious and should not impact an aggressive reactor deployment schedule. Design B uses embedded arrays of heat pipes and fuel pins in a double-wall tank filled with liquid metal sodium. Sodium is used to thermally bond the heat pipes to the fuel pins, but its usage may create reactor transportation and regulatory challenges. An independent panel of U.S. manufacturing experts has preliminarily assessed the three SPR core designs and views Design A as simplest to manufacture. Herein are the results of a preliminary neutronic, thermal, mechanical, material, and manufacturing assessment of both Design A and Design B along with comparisons to the LANL concept (monolithic core structure). Despite the active core differences, all three reactor concepts behave similarly and retain the same ex-core features and characteristics. While INL has developed Designs A and B, LANL is evaluating a Hot Isostatic Pressed reactor configuration to overcome the drawbacks of the monolithic core design.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Precipitation Trade Wind Cumuli within EUREC 4 A Field Campaign Report

The campaign Trades Cumuli Precipitation Initiation and Characterization (TCPIC) within the overarching Elucidating the Role of Clouds-Circulation Coupling in Climate EUREC 4 A campaign took place from 17 January 2020 to 20 February 2020, a total of 35 days. The campaign complemented the more extensive EUREC 4 A campaign focusing on cumulus clouds' role in the Earth's climate. TCPIC concentrated on understanding what triggers the onset and development of precipitation in trade wind cumulus clouds. The campaign requested the deployment of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF) roll, pitch, and heave (RPH) stabilization platform to stabilize two radars on the Maria S. Merian research vessel (RV). The advanced remote-sensing techniques from stabilized radars characterized the entire precipitation life cycle, from the formation of larger cloud drops to precipitation evaporating on its way to the surface. Retrievals of evaporation rates, to track how rain affects the trade wind boundary layer, will be based on the zenith-pointing Doppler observations collected from the stabilized micro rain radar (MRR). Figure 1 shows the instrumentation's deployment on the RV: we installed the AMF RPH stabilization platform and the radars on the uppermost deck (peil deck) of the ship. For installing the devices, we coordinated a test phase of the equipment on the Maria S. Merian RV from 25 to 29 October 2019 in Emden harbor, Germany. In this testing phase, we set up all the connections, tested how to mount the W-band and the micro rain radars firmly on the table, and experimented with guided movements of the table to test the resistance of the whole system. Figure 1 shows the final tests conducted in Emden with the stable platform and the radars mounted.

54 ENVIRONMENTAL SCIENCES↗

FFTF main heat transport system/dump heat exchanger testing and performance evaluation (initial pub date April 1978)

This report covers testing of a Main Heat Transport System/Dump Heat Exchanger (MHTS/DHX) for the Fast Flux Test Facility. The primary objective of the test program was to verify the design and generate experience in the installation, operation, and control of the DHX for FFTF. This report discusses test results related to erection, preoperational testing, in-service inspections, and steady-state and transient performance. Emphasis is placed on the effect of the test results on successful DHX operation at FFTF. 36 figures, 9 tables.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗