Thermal Nondestructive Characterization of Corrosion in Boiler Tubes by Application fo a Moving Line Heat Source

Wall thinning in utility boiler waterwall tubing is a significant inspection concern for boiler operators. Historically, conventional ultrasonics has been used lor inspection of these tubes. This technique has proved to be very labor intensive and slow. This has resulted in a "spot check" approach to inspections, making thickness measurements over a relatively small percentage of the total boiler wall area. NASA Langley Research Center has developed a thermal NDE technique designed to image and quantitatively characterize the amount of material thinning present in steel tubing. The technique involves the movement of a thermal line source across the outer surface of the tubing followed by an infrared imager at a fixed distance behind the line source. Quantitative images of the material loss due to corrosion are reconstructed from measurements of the induced surface temperature variations. This paper will present a discussion of the development of the thermal imaging system as well as the techniques used to reconstruct images of flaws. The application of the thermal line source, coupled with this analysis technique, represents a significant improvement in the inspection speed for large structures such as boiler waterwalls while still providing high-resolution thickness measurements. A theoretical basis for the technique will be presented thus demonstrating the quantitative nature of the technique. Further, results of laboratory experiments on flat Panel specimens with fabricated material loss regions will be presented.

Cramer, K. Elliott↗

Cassini Radio and Plasma Wave Observations at Saturn

Results are presented from the Cassini radio and plasma wave instrument during the approach and first few orbits around Saturn. During the approach the intensity modulation of Saturn Kilometric Radiation (SKR) showed that the radio rotation period of Saturn has increased to 10 hr 45 min plus or minus 36 sec, about 6 min longer than measured by Voyager in 1980-81. Also, many intense impulsive radio signals called Saturn Electrostatic Discharges (SEDs) were detected from saturnian lightning, starting as far as 1.08 AU from Saturn, much farther than terrestrial lightning can be detected from Earth. Some of the SED episodes have been linked to cloud systems observed in Saturn s atmosphere by the Cassini imaging system. Within the magnetosphere plasma wave emissions have been used to construct an electron density profile through the inner region of the magnetosphere. With decreasing radial distance the electron density increases gradually to a peak of about 100 per cubic centimeter near the outer edge of the A ring, and then drops precipitously to values as low as .03 per cubic centimeter over the rings. Numerous nearly monochromatic whistler-mode emissions were observed as the spacecraft passed over the rings that are believed to be produced by meteoroid impacts on the rings. Whistlermode emissions, similar to terrestrial auroral hiss were also observed over the rings, indicating that an electrodynamic interaction, similar to auroral particle acceleration, may be occurring in or near the rings. During the Titan flybys Langmuir probe and plasma wave measurements provided observations of the density and temperature in Titan's ionosphere.

Gurnett, D. A.↗

Tracking the Martian CO2 Polar Ice Caps in Infrared Images

Researchers at NASA s Jet Propulsion Laboratory have developed a method for automatically tracking the polar caps on Mars as they advance and recede each year (see figure). The seasonal Mars polar caps are composed mainly of CO2 ice and are therefore cold enough to stand out clearly in infrared data collected by the Thermal Emission Imaging System (THEMIS) onboard the Mars Odyssey spacecraft. The Bimodal Image Temperature (BIT) histogram analysis algorithm analyzes raw, uncalibrated data to identify images that contain both "cold" ("polar cap") and "warm" ("not polar cap") pixels. The algorithm dynamically identifies the temperature that separates these two regions. This flexibility is critical, because in the absence of any calibration, the threshold temperature can vary significantly from image to image. Using the identified threshold, the algorithm classifies each pixel in the image as "polar cap" or "not polar cap," then identifies the image row that contains the spatial transition from "polar cap" to "not polar cap." While this method is useful for analyzing data that has already been returned by THEMIS, it has even more significance with respect to data that has not yet been collected. Instead of seeking the polar cap only in specific, targeted images, the simplicity and efficiency of this method makes it feasible for direct, onboard use. That is, THEMIS could continuously monitor its observations for any detections of the polar-cap edge, producing detections over a wide range of spatial and temporal conditions. This effort can greatly contribute to our understanding of long-term climatic change on Mars.

Wagstaff, Kiri L.↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

42 ENGINEERING↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

Giera, Brian↗

Correction And Use Of Jitter In Television Images

Proposed system stabilizes jittering television image and/or measures jitter to extract information on motions of objects in image. Alternative version, system controls lateral motion on camera to generate stereoscopic views to measure distances to objects. In another version, motion of camera controlled to keep object in view. Heart of system is digital image-data processor called "jitter-miser", which includes frame buffer and logic circuits to correct for jitter in image. Signals from motion sensors on camera sent to logic circuits and processed into corrections for motion along and across line of sight.

Diner, Daniel B.↗

Implementation of a Pulsed-Laser Measurement System in the National Transonic Facility

A remotely-adjustable laser transmission and imaging system has been developed for use in a high-pressure, cryogenic wind tunnel. Implementation in the National Transonic Facility has proven the system suitable for velocity and signal lifetime measurements over a range of operating conditions. The measurement system allows for the delivery of high-powered laser pulses through the outer pressure shell and into the test section interior from a mezzanine where the laser is free from environmental disturbances (such as vibrations and excessive condensation) associated with operation of the wind tunnel. Femtosecond laser electronic excitation tagging (FLEET) was utilized to provide freestream velocity measurements, and first results show typical data that may be obtained using the system herein described.

Reese, Daniel T.↗

The Proton and Electron Aurora as Seen by Image-FUV and FAST

The Far Ultraviolet (FUV) instrument on IMAGE images the aurora in three different wavelength regions. The Wideband Imaging Camera (WIC) observes the molecular Lyman-Birge-Hopfield (LBH) and atomic Nitrogen emissions at 140-190 nm. The two channels of the Spectrographic Imager (SI) observe the Doppler shifted Lyman Alpha emission of precipitating protons at 121.8 nm (SI 12) and the mostly electron produced emission from oxygen OI at 135.6 nm (SI13). The major advantage of FUV compared to previously flown UV imagers is the simultaneous operation of all three imaging systems without the need for filter changes and the uncertainty of temporal changes of the aurora between exposures. The FAST satellite passes every two hours through FUV images during apogee operations. This enables a comparison between the remotely imaged particle precipitation and the in-situ measurements along the FAST track. The detailed analysis of images from all three systems together with a full simulation of auroral emissions based on in-situ measurements by FAST confirms the laboratory calibrations of FUV. The spatial resolution and image quality of WIC permits the observation of a good correspondence between in-situ and remote measurements of precipitation boundaries. The clear separation between the lower latitude proton precipitation and the more structured higher latitude electron precipitation is obtained with both SI-channels.

Gerard, J.-C.↗

Microparticle analysis system and method

A device for analyzing microparticles is provided which includes a chamber with an inlet and an outlet for respectively introducing and dispensing a flowing fluid comprising microparticles, a light source for providing light through the chamber and a photometer for measuring the intensity of light transmitted through individual microparticles. The device further includes an imaging system for acquiring images of the fluid. In some cases, the device may be configured to identify and determine a quantity of the microparticles within the fluid. Consequently, a method for identifying and tracking microparticles in motion is contemplated herein. The method involves flowing a fluid comprising microparticles in laminar motion through a chamber, transmitting light through the fluid, measuring the intensities of the light transmitted through the microparticles, imaging the fluid a plurality of times and comparing at least some of the intensities of light between different images of the fluid.

Morrison, Dennis R.↗

A PARC system for terminal docking

A Panoramic viewing system for Automated Rendezvous and Capture (PARC) has been proposed as a visual information feedback system for terminal docking/berthing. The system relies on a unique Panoramic Annular Lens (PAL) which captures an image of its surroundings in real time. This paper describes the evolution of the PAL along with technical details of its imaging capabilities. Several examples are given of radial metrology, where PAL imaging systems are used to perform visual inspections and measurements. Digital image acquisition and processing techniques, used to interpret various features appearing in the images and to transform images for improved human viewing, are also included. These discussions are followed by a potential application for PARC involving berthing of active and passive mechanical assemblies associated with Space Station Freedom.

Gilbert, John A.↗

Adiabatic far-field sub-diffraction imaging

The limited resolution of a conventional optical imaging system stems from the fact that the fine feature information of an object is carried by evanescent waves, which exponentially decays in space and thus cannot reach the imaging plane. We introduce here an adiabatic lens, which utilizes a geometrically conformal surface to mediate the interference of slowly decompressed electromagnetic waves at far field to form images. The decompression is satisfying an adiabatic condition, and by bridging the gap between far field and near field, it allows far-field optical systems to project an image of the near-field features directly. Using these designs, we demonstrated the magnification can be up to 20 times and it is possible to achieve sub-50 nm imaging resolution in visible. Our approach provides a means to extend the domain of geometrical optics to a deep sub-wavelength scale.

36 MATERIALS SCIENCE↗

Optical eigenmode imaging

We present an indirect imaging method that measures both amplitude and phase information from a transmissive target. Our method is based on an optical eigenmode decomposition of the light intensity and the first-order cross correlation between a target field and these eigenmodes. We demonstrate that such optical eigenmode imaging does not need any a priori knowledge of the imaging system and corresponds to a compressive full-field sampling, leading to high image extraction efficiencies. Finally, we discuss the implications with respect to second-order correlation imaging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System and method to fuse multiple sources of optical data to generate a high-resolution, frequent and cloud-/gap-free surface reflectance product

Aspects of the subject disclosure may include, for example, performing, by a processing system, image fusion using two or more groups of images to generate predicted images, wherein each group of the two or more groups has one of a different resolution, a different frequency temporal pattern or a combination thereof than another of the two or more groups. Gap filling can be performed by the processing system to correct images of the two or more groups. Additional embodiments are disclosed.

Guan, Kaiyu↗

Advanced solid state sensor system for remote sensing from satellite

Discussion of approaches to providing the needed performance improvement in solid state sensor systems for remote sensing from future resources surveying satellites. An advanced breadboard line array imaging system using long detector arrays from a number of small chips has been built. Test results and typical imagery produced by the breadboard system demonstrate the capabilities of solid state imager technology.

Thompson, L. L.↗

A novel off-axis scanning method for an enlarged ellipse cone-beam computed tomography field of view

Purpose: Current on-board imaging systems commonly used by modern linear accelerators (LINACs) have a limited field of view (FOV) for a cone-beam CT (CBCT) scan, which is typically less than 50 cm. Consequently, truncation artifacts often occur for large patients. The goal of this work is to investigate a novel method to increase the FOV for current on-board CBCT systems. Methods: When a large patient is scanned with CBCT, any region outside the FOV is only partially sampled within a short range of projection angles, and at other angles no x-ray beams may pass through that region. To increase the sampling rate for the region outside the FOV, we have designed a new source trajectory by shifting the center of rotation during a CBCT scan. This resulted in a reduced sampling rate at the central area and increased sampling rate at the edges. The tradeoff led to a more balanced sampling for an enlarged FOV. An iterative algorithm was also developed to reconstruct the CT image under the new sampling scheme using a compressed sensing technique. Results: The method was validated by numerical simulations mimicking a Varian Trilogy CBCT system, and it was found that artifact-free images could be obtained with the FOV as large as 80 cm. Conclusions: The new CT scanning trajectory can be easily realized under current clinical setup with little modification of the control system, and this can be useful for treating obese patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An improved method for simulating microcalcifications in digital mammograms

The assessment of the performance of a digital mammography system requires an observer study with a relatively large number of cases with known truth which is often difficult to assemble. Several investigators have developed methods for generating hybrid abnormal images containing simulated microcalcifications. This article addresses some of the limitations of earlier methods. The new method is based on digital images of needle biopsy specimens. Since the specimens are imaged separately from the breast, the microcalcification attenuation profile scan is deduced without the effects of over and underlying tissues. The resulting templates are normalized for image acquisition specific parameters and reprocessed to simulate microcalcifications appropriate to other imaging systems, with different x-ray, detector and image processing parameters than the original acquisition system. This capability is not shared by previous simulation methods that have relied on extracting microcalcifications from breast images. The method was validated by five experienced mammographers who compared 59 pairs of simulated and real microcalcifications in a two-alternative forced choice task designed to test if they could distinguish the real from the simulated lesions. They also classified the shapes of the microcalcifications according to a standardized clinical lexicon. The observed probability of correct choice was 0.415, 95% confidence interval (0.284, 0.546), showing that the radiologists were unable to distinguish the lesions. The shape classification revealed substantial agreement with the truth (mean kappa=0.70), showing that we were able to accurately simulate the lesion morphology. While currently limited to single microcalcifications, the method is extensible to more complex clusters of microcalcifications and to three-dimensional images. It can be used to objectively assess an imaging technology, especially with respect to its ability to adequately visualize the morphology of the lesions, which is a critical factor in the benign versus malignant classification of a lesion detected in screening mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving low-illumination video

Nonmoving TV pictures are improved by electronic system that removes much of the "snow" or random noise in image. System integrates and averages picture elements in real time and thereby allows easier and more accurate evaluation of image, visually and by computer.

Sapirstein, R. L.↗

Imaging Supersonic Aircraft Shock Waves

A schlieren imaging system that uses the sun as a light source was developed it) obtain direct flow-field images of shock waves of aircraft in flight. This system was used to study how shock waves evolve to form sonic booms. The image quality obtained was limited by several optical and mechanical factors. Converting the photographs to digital images and applying digital image-processing techniques greatly improved the final quality of the images and more clearly showed the shock structures.

Weinstein, Leonard M.↗