Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hardness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Time delays in large and small loop thermal models for hard X-ray bursts

The time histories of the emission at 10, 30, and 100 keV averaged over the loop from small and large loop thermal models of hard X-ray emission are studied. The small (15,000 km) loop cases show a characteristic delay in the peak of the 100 keV emission relative to the 30 keV emission of about 1.5 s which should be detectable. The large (47,000 km) loop cases show no delay, but in the case of a continuous energy input, the 30 keV emission has a peak at 9.5 s whereas the 100 keV emission rises monotonically. A large loop case where only classical and saturated heat conduction is allowed is considered. The 30 keV emission has a peak at 7.5 s whereas the 100 keV emission rises monotonically. The peak temperature reached is 8 x 10 to the 7th K and the probability of finding examples in the data uncontaminated by a dominant beam or escaping tail component should be considerably higher than in the cases with higher rates of energy input.

Smith, D. F.↗

Identification of two hard X-ray emitting Be stars using the HEAO 1 scanning modulation collimator

Using precise positions from the HEAO 1 Scanning Modulation Collimator experiment, two hard X-ray sources, 4U 0728 - 25 = 3A 0726 - 260 and 4U 2206 + 54 = 3A 2206 + 543, are identified with early-type stars. In both cases broad (10 A FWHM) H-alpha emission is detected. The UBV colors suggest that the optical counterparts are main-sequence B0-B2 stars at 2-6 kpc, implying a mean X-ray luminosity of order 10 to the 35th ergs/sq cm s (2-10 keV). The X-ray emission in both cases is highly variable, and it is suggested that they belong to the class of X-ray emitting Be stars, containing a neutron star in a widely separated binary system.

Steiner, J. E.↗

High-resolution spectroscopic observation of Vela X-1 in the hard X-ray energy range

The first high resolution (1.2 keV FWHM hard X-ray equal to or greater than 20 keV) observation of Vela X-1 is reported. Data were accumulated during a 5 hour balloon flight launched on December 5, 1984. A summed epoch analysis yields a light curve and period (283 sec) consistent with previous measurements. Significant pulsations were present to an energy of 60 keV. No statistically significant features were observed in the energy spectrum and the spectrum is well fit (x sup 2 = 17.8 for 16 d.o.f.) by a simple exponential spectrum with an E folding length of 10.8 + or - 1.0 keV.

Tueller, J.↗

Observation of hard X-rays from the Crab pulsar and A0535+26

The Crab pulsar PSR0531+21 was observed in a balloon flight from the Xianghe Balloon Station (China). Data were obtained in the range 20 to 200 keV with a poswish hard X-ray telescope which comprised a 150 sq cm primary crystal of 5 mm thick CsI(T1) which actively shielded the lower 2 pi steradians by a 5 cm thick NaI(T1) crystal. The scintillation pulses originating in CsI and NaI crystals are distinguished by pulse shape discrimination. The telescope has a field of view of approximately 4 deg H psi H pi determined by graded shield and collimator. The effective geometric area of the detector is 116 sq cm. It is noted that when folding a data flow on a long period interference from the data acquisition, transmission and recording system considerably affect the result.

Wu, M.↗

A comparison of calculated and measured background noise rates in hard X-ray telescopes at balloon altitude

An actively shielded hard X-ray astronomical telescope has been flown on stratospheric balloons. An attempt is made to compare the measured spectral distribution of the background noise counting rates over the energy loss range 20-300 keV with the contributions estimated from a series of Monte Carlo and other computations. The relative contributions of individual particle interactions are assessed.

Dean, A. J.↗

A position sensitive phoswich hard X-ray detector system

A prototype position sensitive phoswich hard X-ray detector, designed for eventual astronomical usage, was tested in the laboratory. The scintillation crystal geometry was designed on the basis of a Monte Carlo simulation of the internal optics and includes a 3mm thick NaI(T1) primary X-ray detector which is actively shielded by a 20 mm thick CsI(T1) scintillation crystal. This phoswich arrangement is viewed by a number two inch photomultipliers. Measured values of the positional and spectral resolution of incident X-ray photons are compared with calculation.

Dean, A. J.↗

Development of observational and instrumental techniques in hard X-ray and medium energy gamma-ray astronomy

The technical activities, scientific results, related space hardware projects and personnel of the high energy astrophysics program are reported. The development of observational and instrumental techniques in hard X-ray (0.001 to 100 keV) and medium energy gamma-ray (0.1 to 10 MeV) astronomy are examined. Many of these techniques were developed explicitly for use on high altitude balloons where most of the scientific results were obtained. The extensive observational activity using balloons are tabulated. Virtually every research activity will eventually result in a major space hardware development effort.

Pelling, M.↗

Electron trapping in rad-hard RCA IC's irradiated with electrons and gamma rays

Enhanced electron trapping has been observed in n-channels of rad-hard CMOS devices due to electron and gamma-ray irradiation. Room-temperature annealing results in a positive shift in the threshold potential far beyond its initial value. The slope of the annealing curve immediately after irradiation was found to depend strongly on the gate bias applied during irradiation. Some dependence was also observed on the electron dose rate. No clear dependence on energy and shielding over a delidded device was observed. The threshold shift is probably due to electron trapping at the radiation-induced interface states and tunneling of electrons through the oxide-silicon energy barrier to fill the radiation-induced electron traps. A mathematical analysis, based on two parallel annealing kinetics, hole annealing and electron trapping, is applied to the data for various electron dose rates.

Danchenko, V.↗

An impulsive solar burst observed in H-alpha, microwaves, and hard X-rays

H-alpha, microwave, and hard X-ray observations of an unusually short duration impulsive spike burst are presented. The observations are analyzed, and it is found that the single spike is in fact composed of two separate acceleration episodes. The differences found in the time profiles for the two components stress the role of the decay rate and lead to a simple explanation for the often observed delay of the microwave peak. The approximate numbers of electrons responsible for the two types of emission are derived and compared.

Gary, D. E.↗

Combined analysis of soft and hard X-ray spectra from flares

An attempt is made to develop a self-consistent model which accounts for the line and continuum data generated by the three X-ray imaging instruments on the SMM satellite. The intensities measured covered the 4-500 kV energy range. The model is based on a differential emission measure and electron beam parameters and is used to predict absolute signals detected by the 15 channels of the SMM sensors. Consideration is given to the thermal contribution, instrumental characteristics, thin target excitation and thick target bremsstrahlung. In comparison with data from a flare event on June 29, 1980, model predictions provide a good fit, including the identification of hard electrons with a 5.3 index during the impulsive phase.

Gabriel, A. H.↗

Classical hard-sphere fluid in infinitely many dimensions

The equation of state of the fluid phase of the classical hard-sphere system in infinitely many dimensions has been obtained exactly. Only the first two virial coefficients are nonvanishing. The upper bound for the coefficients of the Mayer series for nonnegative interaction potentials is reached by this system.

Frisch, H. L.↗

Development of a radiation-hard CMOS process

It is recommended that various techniques be investigated which appear to have the potential for improving the radiation hardness of CMOS devices for prolonged space flight mission. The three key recommended processing techniques are: (1) making the gate oxide thin. It has been shown that radiation degradation is proportional to the cube of oxide thickness so that a relatively small reduction in thickness can greatly improve radiation resistance; (2) cleanliness and contamination control; and (3) to investigate different oxide growth (low temperature dry, TCE and HCL). All three produce high quality clean oxides, which are more radiation tolerant. Technique 2 addresses the reduction of metallic contamination. Technique 3 will produce a higher quality oxide by using slow growth rate conditions, and will minimize the effects of any residual sodium contamination through the introduction of hydrogen and chlorine into the oxide during growth.

Power, W. L.↗

Why P/OF should look for evidences of over-dense structures in solar flare hard X-ray sources

White-light and hard X-ray (HXR) observations of two white-light flares (WLFs) show that if the radiative losses in the optical continuum are powered by fast electrons directly heating the WLF source, then the column density constraints imposed by the finite range of the electrons requires that the WLF consist of an over-dense region in the chromosphere, with density exceeding 10 to the 14th power/cu cm. Thus, we recommend that P/OF search for evidences of over-dense structures in HXR images obtained simultaneously with optical observations of flares.

Neidig, D. F.↗

Torso sizing ring construction for hard space suit

A hard suit for use in space or diving applications having an adjustable length torso covering that will fit a large variety of wearers is described. The torso covering comprises an upper section and a lower section which interconnect so that the covering will fit wearers with short torsos. One or more sizing rings may be inserted between the upper and lower sections to accommodate larger torso sizes as required. Since access of the astronaut to the torso covering is preferably through an opening in the back of the upper section (which is closed off by the backpack), the rings slant upward-forward from the lower edge of the opening. The lower edge of the upper covering section has a coupler which slants upward-forward from the lower edge of the back opening. The lower torso section has a similarly slanted coupler which may interfit with the upper section coupler to accommodate the smallest torso size. One or more sizing rings may be inserted between the coupler sections of the upper and lower torso sections to accommodate larger torsos. Each ring has an upper coupler which may interfit with the upper section coupler and a lower coupler which may interfit with the lower section coupler.

Vykukal, H. C.↗

Elbow and knee joint for hard space suits

An elbow or knee joint for a hard space suit or similar usage is formed of three serially connected rigid sections which have truncated spherical configurations. The ends of each section form solid geometric angles, and the sections are interconnected by hermetically sealed ball bearings. The outer two sections are fixed together for rotation in a direction opposite to rotation of the center section. A preferred means to make the outer sections track each other in rotation comprises a rotatable continuous bead chain which engages sockets circumferentially spaced on the facing sides of the outer races of the bearings. The joint has a single pivot point and the bearing axes are always contained in a single plane for any articulation of the joint. Thus flexure of the joint simulates the coplanar flexure of the knee or elbow and is not susceptible to lockup.

Vykukal, H. C.↗