Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fire modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Temperature anisotropy instabilities driven by Whang's ion model

The behavior of four temperature anisotropy instabilities in a single-component space plasma is investigated theoretically using the solar wind model (i.e., heat flux modified non-Maxwellian velocity distribution functions) proposed by Whang (1972). The linear dispersion properties are studied in an infinite Vlasov plasma where the proton distribution is assumed to consist of one warm slow-speed component and where the electron background is isotropic. It is shown that the fire hose, mirror, and Harris instability do not occur under these conditions, and that only the ion cyclotron instability is of importance in Whang's ion model. Growth rates are shown to have values between 0.021 and 0.00011. Increasing temperature anisotropy causes the range frequencies where wave particle interaction occurs to be shifted toward the ion gyrofrequency.

Leubner, M. P.↗

Prescribed fires, smoke exposure, and hospital utilization among heart failure patients

Abstract Background Prescribed fires often have ecological benefits, but their environmental health risks have been infrequently studied. We investigated associations between residing near a prescribed fire, wildfire smoke exposure, and heart failure (HF) patients’ hospital utilization. Methods We used electronic health records from January 2014 to December 2016 in a North Carolina hospital-based cohort to determine HF diagnoses, primary residence, and hospital utilization. Using a cross-sectional study design, we associated the prescribed fire occurrences within 1, 2, and 5 km of the patients’ primary residence with the number of hospital visits and 7- and 30-day readmissions. To compare prescribed fire associations with those observed for wildfire smoke, we also associated zip code-level smoke density data designed to capture wildfire smoke emissions with hospital utilization amongst HF patients. Quasi-Poisson regression models were used for the number of hospital visits, while zero-inflated Poisson regression models were used for readmissions. All models were adjusted for age, sex, race, and neighborhood socioeconomic status and included an offset for follow-up time. The results are the percent change and the 95% confidence interval (CI). Results Associations between prescribed fire occurrences and hospital visits were generally null, with the few associations observed being with prescribed fires within 5 and 2 km of the primary residence in the negative direction but not the more restrictive 1 km radius. However, exposure to medium or heavy smoke (primarily from wildfires) at the zip code level was associated with both 7-day (8.5% increase; 95% CI = 1.5%, 16.0%) and 30-day readmissions (5.4%; 95% CI = 2.3%, 8.5%), and to a lesser degree, hospital visits (1.5%; 95% CI: 0.0%, 3.0%) matching previous studies. Conclusions Area-level smoke exposure driven by wildfires is positively associated with hospital utilization but not proximity to prescribed fires.

Raab, Henry↗

Statistical Models of Areal Distribution of Fragmented Land Cover Types

Imagery of coarse resolution, such weather satellite imagery with 1 square kilometer pixels, is increasingly used to monitor dynamic and fragmented types of land surface types, such as scars from recent fires and ponds in wetlands. Accurate estimates of these land cover types at regional to global scales are required to assess the roles of fires and wetlands in global warming, yet difficult to compute when much of the area is accounted for by fragments about the same size as the pixels. In previous research, we found that size distribution of the fragments in several example scenes fit simple two-parameter models and related effects of coarse resolution to errors in area estimates based on pixel counts. We summarize our model based approach to improved area estimations and report on progress to develop accurate areas estimates based on modeling the size distribution of the fragments, including analysis of size distributions on an expanded set of maps developed from digital imagery.

Hlavka, C.↗

Orion MPCV Continuum RCS Heating Augmentation Model Development

The reaction control system jets of the Orion Multi Purpose Crew Vehicle can have a significant impact on the magnitude and distribution of the surface heat flux on the leeside of the aft-body, when they are fired. Changes in surface heating are expressed in terms of augmentation factor over the baseline smooth body heating. Wind tunnel tests revealed heating augmentation factors as high as 13.0, 7.6, 2.8, and 5.8 for the roll, pitch down, pitch up, and yaw jets respectively. Heating augmentation factor models, based almost exclusively on data from a series of wind tunnel tests have been developed, for the purposes of thermal protection system design. The wind tunnel tests investigated several potential jet-to-freestream similarity parameters, and heating augmentation factors derived from the data showed correlation with the jet-to-freestream momentum ratio. However, this correlation was not utilized in the developed models. Instead augmentation factors were held constant throughout the potential trajectory space. This simplification was driven by the fact that ground to flight traceability and sting effects are not well understood. Given the sensitivity of the reaction control system jet heating augmentation to configuration, geometry, and orientation the focus in the present paper is on the methodology used to develop the models and the lessons learned from the data. The models that are outlined in the present work are specific to the aerothermal database used to design the thermal protection system for the Exploration Flight Test 1 vehicle.

Heating Augmentation↗

Collective neural network behavior in a dynamically driven disordered system of superconducting loops

Collective properties of complex systems composed of many interacting components such as neurons in our brain can be modeled by artificial networks based on disordered systems. We show that a disordered neural network of superconducting loops with Josephson junctions can exhibit computational properties like categorization and associative memory in the time evolution of its state in response to information from external excitations. Superconducting loops can trap multiples of fluxons in many discrete memory configurations defined by the local free energy minima in the configuration space of all possible states. A memory state can be updated by exciting the Josephson junctions to fire or allow the movement of fluxons through the network as the current through them surpasses their critical current thresholds. Simulations performed with a lumped element circuit model of a 4-loop network show that information written through excitations is translated into stable states of trapped flux and their time evolution. Experimental implementation on a high-Tc superconductor YBCO-based 4-loop network shows dynamically stable flux flow in each pathway characterized by the correlations between junction firing statistics. Neural network behavior is observed as energy barriers separating state categories in simulations in response to multiple excitations, and experimentally as junction responses characterizing different flux flow patterns in the network. The state categories that produce these patterns have different temporal stabilities relative to each other and the excitations. This provides strong evidence for time-dependent (short-to-long-term) memories, that are dependent on the geometrical and junction parameters of the loops, as described with a network model.

Josephson junctions↗

Convolutional Non-Homogeneous Poisson Process and its Application to Wildfire Ignition Risk Quantification for Power Delivery Networks

To quantify wildfire ignition risks on power delivery networks, the current practice predominantly relies on the empirically calculated fire danger indices, which may not well capture the effects of dynamically changing environmental factors. This article proposes a spatio-temporal point process model, known as the Convolutional Non-homogeneous Poisson Process (cNHPP), and applies the model to quantify wildfire ignition risks for power delivery networks. The proposed model captures both the current (i.e., instantaneous) and cumulative (i.e., historical) effects of key environmental processes (i.e., covariates) on wildfire risks, as well as the spatio-temporal dependency among different segments of the power delivery network. The computation and interpretation of the intensity function are thoroughly investigated. We apply the proposed approach to estimate wildfire ignition risks on major transmission lines in California, using historical fire data, meteorological and vegetation data obtained from the National Oceanic and Atmospheric Administration and National Aeronautics and Space Administration. Here, a comprehensive comparison study is performed to show the applicability and predictive capability of the proposed approach.

Non-homogeneous Poisson Process↗

Charge-flow structures as polymeric early-warning fire alarm devices

The charge-flow transistor (CFT) and its applications for fire detection and gas sensing were investigated. The utility of various thin film polymers as possible sensing materials was determined. One polymer, PAPA, showed promise as a relative humidity sensor; two others, PFI and PSB, were found to be particularly suitable for fire detection. The behavior of the charge-flow capacitor, which is basically a parallel-plate capacitor with a polymer-filled gap in the metallic tip electrode, was successfully modeled as an RC transmission line. Prototype charge-flow transistors were fabricated and tested. The effective threshold voltage of this metal oxide semiconductor was found to be dependent on whether surface or bulk conduction in the thin film was dominant. Fire tests with a PFI-coated CFT indicate good sensitivity to smouldering fires.

Sechen, C. M.↗

Life Cycle Greenhouse Gas Emissions of Coal-Biomass Co-Firing Power Plants with Carbon Capture and Storage

The United States has set a target to achieve the net-zero economy by 2050. Bioenergy with Carbon Capture and Sequestration (BECCS) is one of the promising negative-emission routes in the mitigation portfolio to help meet this goal. Coal-biomass co-firing with carbon capture and storage (CCS) is a key BECCS technology to realize the carbon mitigation at fossil-fuel power plants. The mitigation potential of co-firing option is affected by numerous critical factors, such as biomass properties, co-firing level, and carbon capture rate. The objectives of the study are to characterize and estimate the life cycle greenhouse gas (GHG) emissions and performance of coal-biomass co-firing power plants with CCS, determine the breakeven co-firing level at power plants necessary to achieve net-zero life cycle emissions, and quantify the variabilities and uncertainties in life cycle emissions. The scope of the life cycle assessment includes the fuel supply, combustion-based power generation, and CO2 transport and storage. A fuel-based life cycle module is developed and embedded in the Integrated Environmental Control Model (IECM), a fossil-fuel power plant modeling tool. This study then applies the enhanced IECM to conduct the process-based life cycle assessment for an array of biomass co-firing scenarios. Deterministic analysis indicates that reaching net-zero life cycle emissions in a biomass co-firing plant without CCS deployment is challenging. Combining biomass co-firing and CCS deployment can significantly lower the overall life cycle emissions of power plants. Net-zero life cycle emissions can be achieved with a 20 wt.% co-firing level and 90% CCS when the Powder River Basin coal is co-fired with energy crops or forestry residues. However, the breakeven co-firing level for net-zero emissions depend on the selected fuel properties. Fuel supply and plant operation are the critical stages influencing the life cycle emissions of power plants with 90% CCS. Deployment of deep CCS beyond 90% CO2 capture can remarkably reduce operational emissions and the breakeven co-firing level. With 99% CCS, the breakeven co-firing rate can be reduced to 12% on average. These findings highlight the trade-offs between technical performance and environmental impact of biomass co-firing at coal-fired power plants and emphasize the role of deep CCS in achieving a net-zero emissions future.

Wu, Wanying↗

Radiant Heating Cookoff Experiments and Predictive Simulations for Fast Cookoff

Thermal initiation (cookoff) of energetic material-laden devices (rocket motors and munitions) during accidental fires is an important safety concern. An article within a pool fire is an example of potential fast cookoff scenerio that has significant potential for a catastrophic result. Beginning in 2007, a collaborative experimental and model development research program under the Joint Munitions Program (JMP) was initiated at SNL/NM to address energetic material response to fast cookoff. The efforts expanded our ongoing research program studying slow cookoff phenomena and sought to answer the key question of "Can our kinetics models derived under slow cookoff conditions be applied to accurately represent energetic material behavior at fast cookoff conditions?" The simplest categorization of slow cookoff is material centered within the energetic material whereas a fast cookoff event is material ignition that occurs at a heated boundary. The external heating rate related to the heat conduction within the energetic material determines the ignition location and thus, the cookoff charaterization of slow or fast. We have developed a benchtop experiment that confines an energetic material sample and exposes it to constant incident heat fluxes common in fire in a controlled and reproducible fashion. Temperatures within the sample near the heated surface are measured using thermocouples and the time-to-event is determined as a function of incident heat flux. Insight and guidance into the experimental development has been provided by one- and three-dimensional simulations of the heat flow paths through the device. Coupling a chemical kinetics model with the heat transfer calculations enable computational predictions of time-to-ignition for comparison to the experimental data. Experimental and predicted data for PBXN-109, PBX-9501, PBX-9502, and Composition B are presented. The final section of this report presents an initial approach aimed at studing the effect of confinement on ignition and sustained reaction.

36 MATERIALS SCIENCE↗

Coordinated Scheduling for Interdependent Electric Power and Natural Gas Infrastructures

The extensive installation of gas-fired power plants in many parts of the world has led electric systems to depend heavily on reliable gas supplies. The use of gas-fired generators for peak load and reserve provision causes high intraday variability in withdrawals from high-pressure gas transmission systems. Such variability can lead to gas price fluctuations and supply disruptions that affect electric generator dispatch, electricity prices, and threaten the security of power systems and gas pipelines. These infrastructures function on vastly different spatio-temporal scales, which prevents current practices for separate operations and market clearing from being coordinated. Here in this article, we apply new techniques for control of dynamic gas flows on pipeline networks to examine day-ahead scheduling of electric generator dispatch and gas compressor operation for different levels of integration, spanning from separate forecasting, and simulation to combined optimal control. We formulate multiple coordination scenarios and develop tractable physically accurate computational implementations. These scenarios are compared using an integrated model of test networks for power and gas systems with 24 nodes and 24 pipes, respectively, which are coupled through gas-fired generators. The analysis quantifies the economic efficiency and security benefits of gas-electric coordination and dynamic gas system operation.

03 NATURAL GAS↗

Analysis of thermal radiation of a gas-particulate-cloud in a pressurized oxy-coal combustor

Pressurized oxy-combustion (POC) aims to reduce carbon emissions from coal-fired power plants. In the POC process, pulverized coal is burned at elevated pressure in an O2-CO2 environment. The elevated pressure and high CO2 and H2O concentrations strongly impact thermal radiation, thereby significantly distinguishing POC system from conventional atmospheric-pressure air-fired and oxy-fuel combustion. Consequently, a thorough understanding of thermal radiation in POC is required to promote the development of novel combustors. The present computational work analyzes thermal radiation of the gaseous and particle phases in the pilot-scale POC combustor in Washington University in St. Louis. Particularly, the radiation characteristics of the gaseous and particulate cloud were estimated by employing the statistical narrow band model and the large-particle model. It is found that thermal radiation of a particulate cloud dominates in the combustor under the conditions of a furnace temperature of 1500 K and no substantial particle loss. Another important result is that the gas-and-particulate cloud can be approximately treated as a graybody under the same conditions. To be more specific, the results of spectral radiation intensity of a gas comprised of 40% (vol) H2O and 60% CO2 show that when the pressure is increased to 15 bar, and the radiation pathlength to 100 cm, the spectral radiation profile of the gas phase approaches that of a blackbody at the respective temperature. In addition, the emissivity of the particulate cloud has been evaluated as a function of the particle concentration and diameter by means of the large particle model. It is shown that the emissivity grows with the particle concentration but decreases with the particle size for the same mass of a particulate cloud. The emissivity of a particulate cloud in oxy- combustion exceeds that in air-fired combustion. This work could be used to validate the assumption of the gray gas model adopted in numerical simulations.

Li, Lei↗

Mechanism of formation of wiggly compaction bands in porous sandstone: 1. Observations and conceptual model

Field observations are combined with microscopic analyses to investigate the mechanism of formation of wiggly compaction bands (CBs) in the porous Jurassic aeolian Aztec Sandstone exposed at Valley of Fire State Park, Nevada. Among the three types of CBs (T1, T2, and T3), we focused on the wiggly CBs (T3), which show a chevron (T3 1 ) or wavy (T3 2 ) pattern with typical corner angles of approximately 90° or 130°, respectively. Where corner angles of wiggly CBs increase to 180°, they become straight CBs (T3 3 ). Image analyses of thin sections using an optical microscope show host rock porosity increases downslope in this dune, and the predominant type of wiggly CBs also varies from chevron to straight CBs. Specifically, band type varies continuously from chevron to wavy to straight where the porosity and grain sorting of the host rock increase systematically. Based on the crack and anticrack models, we infer that the change from chevron to straight CBs is due to increasing failure angle of the sandstone and this may correlate with increasing grain sorting. Wavy CBs with intermediate failure angle and host rock porosity are an intermediate stage between chevron and straight CBs. Previous sedimentological studies also have suggested that grain size and sorting degree increase downslope on the downwind side of sand dunes due to a sieving process of the wind-blown grains. Furthermore, the transition of wiggly CB types in this regard correlates with increasing sorting and perhaps with increasing porosity downslope.

58 GEOSCIENCES↗

Reliable Ignition of LOX-LCH4 Propellants

No cryogenic Reaction Control System (RCS) has ever flown in space. Cryogenic propellants are baselined by HLS and CLPS partners and are the key use case for future ISRU manufactured propellants. A reliable LOX/LCH 4 RCS is an enabling technology for human Lunar and Mars exploration. In previous thermal vacuum (<275 F, <10 torr) testing at NASA GRC Plum Brook, the team uncovered anomalous LOX/LCH4 engine ignition phenomena where flame kernels quenched at these ultra cold hardware temperatures, leading to many pulses where the engines would not light. In 2022, the project was able to recreate the no light condition with an upgraded Frost-Mint test stand at JSC. This project implemented test stand improvements and procured propellants and follow on engine components for a hot fire campaign beginning in November 2024 which will attempt to ignite the RCS engine at ultra cold vacuum conditions by modifying the engine mixture ratio. New modeling techniques were implemented to account for past no lights and are an enabling method to make lunar surface go no go predictions based on hardware conditions. This was enabled by significant improvements to the Frost Mint system, which reduced moisture build up and leaks, increased propellant availability, leading to more attempts at thermal vacuum hot-fires.

Propulsion↗

Carbon Consequences of Forest Disturbance and Recovery Across the Conterminous United States

Forests of North America are thought to constitute a significant long term sink for atmospheric carbon. The United States Forest Service Forest Inventory and Analysis (FIA) program has developed a large data base of stock changes derived from consecutive estimates of growing stock volume in the US. These data reveal a large and relatively stable increase in forest carbon stocks over the last two decades or more. The mechanisms underlying this national increase in forest stocks may include recovery of forests from past disturbances, net increases in forest area, and growth enhancement driven by climate or fertilization by CO2 and Nitrogen. Here we estimate the forest recovery component of the observed stock changes using FIA data on the age structure of US forests and carbon stocks as a function of age. The latter are used to parameterize forest disturbance and recovery processes in a carbon cycle model. We then apply resulting disturbance/recovery dynamics to landscapes and regions based on the forest age distributions. The analysis centers on 28 representative climate settings spread about forested regions of the conterminous US. We estimate carbon fluxes for each region and propagate uncertainties in calibration data through to the predicted fluxes. The largest recovery-driven carbon sinks are found in the South central, Pacific Northwest, and Pacific Southwest regions, with spatially averaged net ecosystem productivity (NEP) of about 100 g C / square m / a driven by forest age structure. Carbon sinks from recovery in the Northeast and Northern Lake States remain moderate to large owing to the legacy of historical clearing and relatively low modern disturbance rates from harvest and fire. At the continental scale, we find a conterminous U.S. forest NEP of only 0.16 Pg C/a from age structure in 2005, or only 0.047 Pg C/a of forest stock change after accounting for fire emissions and harvest transfers. Recent estimates of NEP derived from inventory stock change, harvest, and fire data show twice the NEP sink we derive from forest age distributions. We discuss possible reasons for the discrepancies including modeling errors and the possibility of climate and/or fertilization (CO2 or N) growth enhancements.

Williams, Christopher A.↗

Energy Efficiency Upgrades

The energy efficiency upgrades project at Hardin County General Hospital did not include research nor was it a demonstration project. The project enabled the hospital to replace outdated systems with modern efficient models. Hardin County General Hospital is a 501c3, nonprofit hospital and the sole community provider for Hardin and Pope Counties of Illinois. This project provided much needed equipment and facility upgrades that would not have been possible through locally generated funding. Task 1 was a reroofing of the hospital. The hospital architect designed the replacement to increase the energy efficiency of the hospital roof/ceiling structure. Task 2 was replacement and installation of a new more efficient CT scanner for the hospital. Included in the project was replacement of HVAC equipment for the entire radiological suite. Task 5 was a replacement and installation of a new higher capacity diesel-fueled emergency generator for the hospital replacing a 50+ year old gas-fired generator. Task 7 was the replacement of 50+ year-old walk-in cooler/freezer with a newer, energy efficient model. Task 8 was the replacement of 10+ year-old washing machines in the hospital laundry with higher capacity, energy efficient models. Task 9 was replacement of 50-year old single pane curtain window system with double-pane insulated windows. Additionally, insulation was added around ventilation systems and the curtain wall system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Failure Mode Analysis of V-Shaped Pyrotechnically Actuated Valves

Current V-shaped stainless steel pyrovalve initiators have rectified many of the deficiencies of the heritage Y-shaped aluminum design. However, a credible failure mode still exists for dual simultaneous initiator (NSI) firings in which low temperatures were detected at the booster cap and less consistent ignition was observed than when a single initiator was fired. In order to asses this issue, a numerical framework has been developed for predicting the flow through pyrotechnically actuated valves. This framework includes a fully coupled solution of the gas-phase equation with a non-equilibrium dispersed phase for solid particles as well as the capability to model conjugate gradient heat transfer to the booster cap. Through a hierarchy of increasingly complex simulations, a hypothesis for the failure mode of the nearly simultaneous dual NSI firings has been proven. The simulations indicate that the failure mode for simultaneous dual NSI firings may be caused by flow interactions between the flame channels. The shock waves from each initiator interact in the booster cavity resulting in a high pressure that prevents the gas and particulate velocity from rising in the booster cap region. This impedes the bulk of the particulate phase from impacting the booster cap and reduces the heat transfer to the booster cap since the particles do not impact it. Heat transfer calculations to the solid metal indicate that gas-phase convective heat transfer may not be adequate by itself and that energy transfer from the particulate phase may be crucial for the booster cap burn through.

Sachdev, Jai S.↗

Spatiotemporal predictions of toxic urban plumes using deep learning

Industrial accidents, chemical spills, and structural fires can release large amounts of harmful materials that disperse into urban atmospheres and impact populated areas. Computer models are typically used to predict the transport of toxic plumes by solving fluid dynamical equations. However, these models can be computationally expensive due to the need for many grid cells to simulate turbulent flow and resolve individual buildings and streets. In emergency response situations, alternative methods are needed that can run quickly and adequately capture important spatiotemporal features. Here, we present a novel deep learning model called ST-GasNet inspired by the mathematical equations that govern the behavior of plumes as they disperse through the atmosphere. ST-GasNet learns the spatiotemporal dependencies from a limited set of temporal sequences of ground-level toxic urban plumes generated by a high-resolution large eddy simulation model. On independent sequences, ST-GasNet accurately predicts the late-time spatiotemporal evolution, given the early-time behavior as an input, even when a building splits a large plume into smaller plumes. By incorporating large-scale wind boundary condition information, ST-GasNet achieves a prediction accuracy of at least 90% on test data for the entire prediction period.

Civil and Environmental Engineering↗

Estimation of uncertainty bounds for the future performance of a power plant

Prediction of the future performance of large-scale power plants can be very relevant for the operators of these plants, as the predictions can indicate possible problems or failures due to current operating conditions and/or future possible operating conditions. A problem in predicting the future performance of these plants is that available models of the plants are uncertain. In this brief, three schemes for predicting uncertain dynamical systems are presented. The schemes estimate upper and lower bounds on the system performance. Two of the schemes are statistically based, one only based on recent data and the other is based on operating points as well. The third proposed scheme uses dynamical models of the prediction uncertainties. The proposed schemes are subsequently applied to experimental data from a coal-fired power plant. Two sets of data from an actual power plant are used, one containing normal plant operation and in the second set, coal is accumulating in the coal mill due to an unbalance in the operating conditions. These tests showed that Schemes II and III did bound the real system performance, while Scheme I failed doing so. In addition, the plant was simulated operating under the same conditions with additional large disturbances. These simulations were used to investigate the robustness and conservatism of the proposed schemes. In this test, Schemes I and II failed, while Scheme III succeeded.

20 FOSSIL-FUELED POWER PLANTS↗