Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “evaluation study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Economy-wide evaluation of CO 2 and air quality impacts of electrification in the United States

Adopting electric end-use technologies instead of fossil-fueled alternatives, known as electrification, is an important economy-wide decarbonization strategy that also reduces criteria pollutant emissions and improves air quality. In this study, we evaluate CO 2 and air quality co-benefits of electrification scenarios by linking a detailed energy systems model and a full-form photochemical air quality model in the United States. We find that electrification can substantially lower CO 2 and improve air quality and that decarbonization policy can amplify these trends, which yield immediate and localized benefits. In particular, transport electrification can improve ozone and fine particulate matter (PM 2.5 ), though the magnitude of changes varies regionally. However, growing activity from non-energy-related PM 2.5 sources—such as fugitive dust and agricultural emissions—can offset electrification benefits, suggesting that additional measures beyond CO 2 policy and electrification are needed to meet air quality goals. We illustrate how commonly used marginal emissions approaches systematically underestimate reductions from electrification.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by the patient-specific respiratory waveforms; when testing patient and sinusoidal waveforms separately, patient waveforms were significantly different between phases (p < 0.0001) while the sinusoidal waveforms were not significantly different (p = 0.98). When considering only the subset of 4DMATCH images that corresponded to the end-exhale image phase, 4DEXH, mean and interquartile range were similar to 4DMATCH but variability was considerably reduced. Conclusions: Comparative advantages in accuracy and precision of SUV metrics and segmented volumes were demonstrated with the use of the maximum intensity projection and end-exhale CT attenuation correction. While respiratory phase-matched CTAC should in theory provide optimal corrections, image artifacts and differences in implementation of 4DCT and 4DPET sorting can degrade the benefit of this approach. These results may be useful to guide the implementation, analysis, and development of respiratory-correlated thoracic PET/CT in the radiation oncology and diagnostic settings.

60 APPLIED LIFE SCIENCES↗

A Phase I Trial of Tipifarnib With Radiation Therapy, With and Without Temozolomide, for Patients With Newly Diagnosed Glioblastoma

Purpose: To determine the maximum tolerated dose (MTD) of tipifarnib in combination with conventional radiotherapy for patients with newly diagnosed glioblastoma. The MTD was evaluated in three patient cohorts, stratified based on concurrent use of enzyme-inducing antiepileptic drugs (EIAED) or concurrent treatment with temozolomide (TMZ): Group A: patients not receiving EIAED and not receiving TMZ; Group A-TMZ: patients not receiving EIAED and receiving treatment with TMZ; Group B: any patients receiving EIAED but not TMZ. Patients and Methods: After diagnostic surgery or biopsy, treatment with tipifarnib started 5 to 9 days before initiating radiotherapy, twice daily, in 4-week cycles using discontinuous dosing (21 out of 28 days), until toxicity or progression. For Group A-TMZ, patients also received TMZ daily during radiotherapy and then standard 5/28 days dosing after radiotherapy. Dose-limiting toxicity (DLT) was determined over the first 10 weeks of therapy for all cohorts. Results: Fifty-one patients were enrolled for MTD determination: 10 patients in Group A, 21 patients in Group A-TMZ, and 20 patients in Group B. In the Group A and Group A-TMZ cohorts, patients achieved the intended MTD of 300 mg twice daily (bid) with DLTs including rash and fatigue. For Group B, the MTD was determined as 300 mg bid, half the expected dose. The DLTs included rash and one intracranial hemorrhage. Thirteen of the 20 patients evaluated in Group A-TMZ were alive at 1 year. Conclusion: Tipifarnib is well tolerated at 300 mg bid given discontinuously (21/28 days) in 4-week cycles, concurrently with standard chemo/radiotherapy. A Phase II study should evaluate the efficacy of tipifarnib with radiation and TMZ in patients with newly diagnosed glioblastoma and not receiving EIAED.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increasing fish taxonomic and functional richness affects ecosystem properties of small headwater prairie streams

Stream fish can regulate their environment through direct and indirect pathways, and the relative influence of communities with different taxonomic and functional richness on ecosystem properties likely depends on habitat structure. Given this complexity, it is not surprising that observational studies of how stream fish communities influence ecosystems have shown mixed results. In this study, we evaluated the effect of an observed gradient of taxonomic (zero, one, two or three species) and functional (zero, one or two groups) richness of fishes on several key ecosystem properties in experimental stream mesocosms. Our study simulated small (less than two metres wide) headwater prairie streams with a succession of three pool-riffle structures (upstream, middle and downstream) per mesocosm. Additionally, ecosystem responses included chlorophyll a from floating algal mats and benthic algae, benthic organic matter, macroinvertebrates (all as mass per unit area), algal filament length and stream metabolism (photosynthesis and respiration rate). Ecosystem responses were analysed individually using general linear mixed models. Significant treatment (taxonomic and functional richness) by habitat (pools and riffles) interactions were found for all but one ecosystem response variable. After accounting for location (upstream, middle and downstream) effects, the presence of one or two grazers resulted in shorter mean algal filament lengths in pools compared to no-fish controls. These observations suggest grazers can maintain short algal filaments in pools, which may inhibit long filaments from reaching the surface. Accordingly, floating algal mats decreased in mid- and downstream locations in grazer treatment relative to no-fish controls. At the scale of the entire reach, gross primary productivity and respiration were greater in treatments with two grazer species compared to mixed grazer/insectivore or control treatments. Lastly, the distribution of stream resources across habitat types and locations within a reach can therefore be influenced by the taxonomic and functional composition of fishes in small prairie streams. Thus, disturbances that alter diversity of these systems might have unexpected ecosystem-level consequences.

54 ENVIRONMENTAL SCIENCES↗

Collection of fission and activation product elements from fresh and ocean waters: a comparison of traditional and novel sorbents

Monitoring natural waters for the inadvertent release of radioactive fission products produced as a result of nuclear power generation downstream from these facilities is essential for maintaining water quality. To this end, we evaluated sorbents for simultaneous in-situ large volume extraction of radionuclides with both soft (e.g., Ag) and hard metal (e.g., Co, Zr, Nb, Ba, and Cs) or anionic (e.g., Ru, Te, Sb) character. In this study, we evaluated a number of conventional and novel nanoporous sorbents in both fresh and salt waters. In most cases, the nanoporous sorbents demonstrated enhanced retention of analytes. Salinity had significant effects upon sorbent performance and was most significant for hard cations, specifically Cs and Ba. The presence of natural organic matter had little effect on the ability of chemisorbents to extract target elements.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Optimized Machine Learning Model for Predicting Groundwater Contamination

The use of physical models to predict groundwater contaminant movement remains technically challenging due to the complexity of the phenomena, the heterogeneity of key parameters in nature, and the presence of poorly defined interactive and feedback processes. New approaches to address these challenges are needed. In this study, we evaluate various Artificial Intelligence (AI)-based approaches to understand a hexavalent chromium (Cr(VI)) plumes located on the U.S. Department of Energy’s (DOE) Hanford Site in Richland, WA. The groundwater monitoring dataset used in this study included data from the 100 Area along the Columbia River and included data collected between 2010 to 2019. This study investigates the most prominent contaminant, Cr(VI), with the Extreme Gradient Boosting (XGBoost) machine learning model. The XGBoost models were compared with optimized versions using an Empirical Bayes Search Cross-Validation technique for better prediction. The optimized XGBoost model yielded an R^2 value of 0.99 on the training set and 0.85 on the testing set, whereas XGBoost without optimization yielded a value of 0.83 on the training set and 0.85 on the testing set. This paper provides an overview of a computational method for groundwater contamination modeling that shows promise for improving current remediation efforts.

Mazumdar, Hirak↗

Management of Rectal Cancer: Short- vs. Long-Course Preoperative Radiation

There is considerable debate on the optimum approach to neoadjuvant therapy in rectal cancer. This review of major published studies of short-course preoperative radiation and the more conventional approach of long-course neoadjuvant chemoradiation was undertaken in an effort to understand the potential advantages and disadvantages of each of these approaches. Studies were evaluated with regard to patient selection, clinical outcomes, and toxicities. Short-course preoperative radiation has shown a clear advantage over surgery alone in reducing local recurrence rates and improving survival of patients with rectal cancer. However, studies using short-course preoperative treatment have included a significant number of early (30%; Stage I/II) and more proximal cancers yet appear to have higher positive margin rates, higher abdominoperineal resection rates, and lower aggregate survival than patients treated with long-course neoadjuvant chemoradiation. Although long-course preoperative chemoradiation is associated with higher rates of reversible acute toxicity, there appears to be more significant and a higher rate of late gastrointestinal toxicity observed in short-course preoperative radiation studies. Patient convenience and lower cost of treatment, however, can be a significant advantage in using a short-course treatment schedule. Selective utilization of either of these approaches should be based on extent of disease and goals of treatment. Patients with distal cancers or more advanced disease (T3/T4) appear to have better outcomes with neoadjuvant chemoradiation, especially where downstaging of disease is critical for more complete surgical resection and sphincter preservation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Remaining Life Prediction of SNF Storage Canisters Exposed to CISCC Environments

• DOE Standardized SNF Storage Canisters o DOE designed standard spent nuclear fuel (SNF) storage canisters for storage of DOE SNF. o DOE canisters are significantly different from commercial MultiPurpose Canisters (MPC) in size. o MPC canisters are large, a height = 15.8 ft, OD = 68”, WT = 0.5”. o DOE canisters are small with 18” / 24” diameter, 10’ / 15’ length. • Integrity Evaluation of DOE versus MPC Canisters o Many investigations have been performed for MPC canisters. o Limit investigations were performed for DOE standard canisters. Most were done at Idaho National Lab (INL). o DOE has sponsored integrity studies to evaluate weld integrity using drop tests and FEA simulations. o No evaluation on CISCC/service life of DOE canister in literature. o MPC canister: 4 axial welds, 1 center girth weld, 2 closing welds.

ZHU, Xiankui↗

Status Report on Activities of the Systems Assessment Task Force, OECD-NEA Expert Group on Accident Tolerant Fuels for LWRs

The Organization for Economic Cooperation and Development /Nuclear Energy Agency (OECD/NEA) Nuclear Science Committee approved the formation of an Expert Group on Accident Tolerant Fuel (ATF) for LWRs (EGATFL) in 2014. Chaired by Kemal Pasamehmetoglu, INL Associate Laboratory Director for Nuclear Science and Technology, the mandate for the EGATFL defines work under three task forces: (1) Systems Assessment, (2) Cladding and Core Materials, and (3) Fuel Concepts. Scope for the Systems Assessment task force includes definition of evaluation metrics for ATF, technology readiness level definition, definition of illustrative scenarios for ATF evaluation, parametric studies, and selection of system codes. The Cladding and Core Materials and Fuel Concepts task forces will identify gaps and needs for modeling and experimental demonstration; define key properties of interest; identify the data necessary to perform concept evaluation under normal conditions and illustrative scenarios; identify available infrastructure (internationally) to support experimental needs; and make recommendations on priorities. Where possible, considering proprietary and other export restrictions (e.g., International Traffic in Arms Regulations), the Expert Group will facilitate the sharing of data and lessons learned across the international group membership. The Systems Assessment Task Force is chaired by Shannon Bragg-Sitton (INL), while the Cladding Task Force will be chaired by a representative from France (Marie Moatti, Electricite de France [EdF]) and the Fuels Task Force will be chaired by a representative from Japan (Masaki Kurata, Japan Atomic Energy Agency [JAEA]). This report provides an overview of the Systems Assessment Task Force charter and status of work accomplishment.

99 GENERAL AND MISCELLANEOUS↗

Analysis of Exposure during Transportation of Waste to the Nevada National Security Site (NNSS) - 20445

Safety is a priority for the U.S. Department of Energy (DOE) Environmental Management (EM) Nevada Program. This commitment to safety is integrated into requirements and work procedures at DOE sites across the U.S. that generate low-level radioactive waste, mixed low-level radioactive waste, and classified waste that is transported to the Nevada National Security Site (NNSS) for permanent disposal. Generators of this waste are responsible for ensuring it is packaged and transported in a safe and compliant manner. These generators and their contracted commercial carriers must comply with U.S. Department of Transportation (DOT) regulations; the Nevada National Security Site Waste Acceptance Criteria (NNSSWAC); and other applicable federal, state, and local regulations and requirements. This includes packaging and shipping the waste to meet DOT regulatory radiation dose limits to ensure public safety during transportation. NNSS waste generators have a solid safety record for complying with these stringent regulations as demonstrated by the fact that no shipments exceeding DOT dose rate limits were received at the NNSS Area 5 Radioactive Waste Management Complex (RWMC) during FY 2014 through FY 2018. A 2005 study conducted by the Desert Research Institute validated shipments to the NNSS comply with DOT radiation dose limits. In response to recent Nevada stakeholder requests for an updated study, an analysis was conducted to verify and provide evidence that the public continues to be safe from exposure to radioactive waste shipment to the NNSS. Radiation exposure from radioactive waste shipments in transit to the NNSS was evaluated. Three studies were performed: 1. Confirm compliance of waste shipments to the DOT radiation limits using dose rate surveys taken at the generator site and at the disposal site. 2. Estimate the dose to the public from waste shipments using the dosimetry results for disposal site personnel by comparing time of exposure for various individuals/scenarios. 3. Estimate the truck driver dose using the receipt dose rate surveys and time of exposure, and from dosimetry results. Study 1 confirmed compliance with the DOT dose rate limits for a sample of waste shipments (123 of 1,038) received during fiscal year (FY) 2017. Study 2 showed that the average annual radiation equivalent dose for disposal site personnel during FY 2017 was approximately 6.7% [0.415 mSv (41.5 millirem)] of the annual average dose that a person living in the U.S. receives from all sources [6.2 mSv (620 mrem)]. Maximum dose to a member of the public, a person resting/sleeping in an adjacent truck at a rest area to a waste shipment, was 0.0166 mSv (1.66 mrem), which is less than the dose received from a person taking a round trip from the east coast to the west coast of the continental U.S. on an airplane [0.07 mSv (7 mrem) per round trip]. Study 3 showed that the truck driver who made the most shipments of radioactive waste to the NNSS, who drove the most hours (estimated time of exposure 2,520 hours), during FY 2017 had a total dose of 0.15 mSv (15 mrem), which was obtained from their personal dosimeter. The annual dose recorded for disposal site personnel, the dose estimates for the public, and the truck driver dose were all a small percentage of the average radiation dose a person receives from all sources (e.g., background and medical radiation). At these levels, risk should only be described qualitatively. Radiation exposure from radioactive waste shipments to the NNSS were shown to be compliant with the DOT dose rate limits, safe, and very low (i.e., within background levels). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Anal Canal Cancer: Management of Inguinal Nodes and Benefit of Prophylactic Inguinal Irradiation (CORS-03 Study)

Purpose: To evaluate the benefit of prophylactic inguinal irradiation (PII) in anal canal squamous cell carcinoma (ASCC). Methods and Materials: This retrospective study analyzed the outcome of 208 patients presenting with ASCC treated between 2000 and 2004 in four cancer centers of the south of France. Results: The population study included 35 T1, 86 T2, 59 T3, 20 T4, and 8 T stage unknown patients. Twenty-seven patients presented with macroscopic inguinal node involvement. Of the 181 patients with uninvolved nodes at presentation, 75 received a PII to a total dose of 45-50 Gy (PII group) and 106 did not receive PII (no PII group). Compared with the no PII group, patients in the PII group were younger (60% vs. 41% of patients age <68 years, p = 0.01) and had larger tumor (T3-4 = 46% vs. 27% p = 0.01). The other characteristics were well balanced between the two groups. Median follow-up was 61 months. Fourteen patients in the no PII group vs. 1 patient in the PII group developed inguinal recurrence. The 5-year cumulative rate of inguinal recurrence (CRIR) was 2% and 16% in PII and no PII group respectively (p = 0.006). In the no PII group, the 5-year CRIR was 12% and 30% for T1-T2 and T3-T4 respectively (p = 0.02). Overall survival, disease-specific survival, and disease-free survival were similar between the two groups. In the PII group, no Grade >2 toxicity of the lower extremity was observed. Conclusion: PII with a dose of 45 Gy is safe and highly efficient to prevent inguinal recurrence and should be recommended for all T3-4 tumors. For early-stage tumors, PII should also be discussed, because the 5-year inguinal recurrence risk remains substantial when omitting PII (about 10%).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

External Pelvic and Vaginal Irradiation Versus Vaginal Irradiation Alone as Postoperative Therapy in Medium-Risk Endometrial Carcinoma-A Prospective Randomized Study

Purpose: To evaluate the value of adjuvant external beam pelvic radiotherapy as adjunct to vaginal brachytherapy (VBT) in medium-risk endometrial carcinoma, with regard to locoregional tumor control, recurrences, survival, and toxicity. Methods and Materials: Consecutive series of 527 evaluable patients were included in this randomized trial. Median follow-up for patients alive was 62 months. The primary study endpoints were locoregional recurrences and overall survival. Secondary endpoints were recurrence-free survival, recurrence-free interval, cancer-specific survival, and toxicity. Results: Five-year locoregional relapse rates were 1.5% after external beam radiotherapy (EBRT) plus VBT and 5% after vaginal irradiation alone (p = 0.013), and 5-year overall survival rates were 89% and 90%, respectively (p = 0.548). Endometrial cancer-related death rates were 3.8% after EBRT plus VBT and 6.8% after VBT (p = 0.118). Pelvic recurrences (exclusively vaginal recurrence) were reduced by 93% by the addition of EBRT to VBT. Deep myometrial infiltration was a significant prognostic factor in this medium-risk group of endometrioid carcinomas but not International Federation of Gynecology and Obstetrics grade or DNA ploidy. Combined radiotherapy was well tolerated, with serious (Grade 3) late side effects of less than 2%. However, there was a significant difference in favor of VBT alone. Conclusions: Despite a significant locoregional control benefit with combined radiotherapy, no survival improvement was recorded, but increased late toxicity was noted in the intestine, bladder, and vagina. Combined RT should probably be reserved for high-risk cases with two or more high-risk factors. VBT alone should be the adjuvant treatment option for purely medium-risk cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Digital Radiography and Computed Tomography (DRCT) Product Improvement Plan (PIP)

The Idaho National Laboratory (INL) has been developing and deploying x-ray inspection systems for chemical weapons containers for the past 12 years under the direction of the Project Manager for Non-Stockpile Chemical Materiel (PMNSCM). In FY-10 funding was provided to advance the capabilities of these systems through the DRCT (Digital Radiography and Computed Tomography) Product Improvement Plan (PIP), funded by the PMNSCM. The DRCT PIP identified three research tasks; end user study, detector evaluation and DRCT/PINS integration. Work commenced in February, 2010. Due to the late start and the schedule for field inspection of munitions at various sites, it was not possible to spend sufficient field time with operators to develop a complete end user study. We were able to interact with several operators, principally Mr. Mike Rowan who provided substantial useful input through several discussions and development of a set of field notes from the Pueblo, CO field mission. We will be pursuing ongoing interactions with field personnel as opportunities arise in FY-11.

99 GENERAL AND MISCELLANEOUS↗

Evaluating project level investment trends for the U.S. ESCO industry: 1990–2017

Energy efficiency is widely recognized as a cost-effective strategy to meet energy demand. The U.S. energy service company (ESCO) industry generates significant energy savings and other benefits through installing and maintaining energy efficiency, renewable and other types of projects. In this study, we evaluate factors that may explain trends in the economic performance of U.S. ESCO projects by analyzing project level data for ~7000 U.S. ESCO industry projects. We find that real project investment levels normalized for floor area have increased over time in ESCO projects across market segments. However, the dollar value of energy savings and other reported benefits have not kept pace with increases in real project investment levels over time. The latter have increased 100%–500% in various market segments from 1990 to 2017. We conduct an econometric analysis to decompose the drivers of these underlying trends. Number of measures and a changing mix of conservation measures are the primary factors that correlate with the long-term increase in project investment levels. However, our analysis is only able to account for less than 50% of the increase in real investment levels. Finally, we discuss additional factors, and conclude discussing policy implications and outlining long-term research needs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Control Board Digital Interface Input Devices – Touchscreen, Trackpad, or Mouse?

The authors collaborated with a power utility to evaluate input devices for use in the human system interface (HSI) for a new digital Turbine Control System (TCS) at a nuclear power plant (NPP) undergoing a TCS upgrade. A standalone dynamic software simulation of the new digital TCS and a mobile kiosk were developed to conduct an input device study to evaluate operator preference and input device effectiveness. The TCS software presented the anticipated HSI for the TCS and mimicked (i.e., simulated) the turbine systems’ responses to operator commands. Twenty-four licensed operators from the two nuclear power units participated in the study. Three input devices were tested: a trackpad, mouse, and touchscreen. The subjective feedback from the survey indicates the operators preferred the touchscreen interface. The operators subjectively rated the touchscreen as the fastest and most comfortable input device given the range of tasks they performed during the study, but also noted a lack of accuracy for selecting small targets. The empirical data suggest the mouse input device provides the most consistent performance for screen navigation and manipulating on screen controls. The trackpad input device was both empirically and subjectively found to be the least effective and least desired input device.

control room modernization↗

Evaluating size exclusion chromatography for nucleic acid removal in Klebsiella pneumoniae cell surface polysaccharide purification

Cell surface-associated polysaccharides in Klebsiella are major virulence determinants and crucial targets for developing vaccines. Traditionally, the purification of these cell surface polysaccharides from Klebsiella pneumoniae involves a multi-step process comprising phenol extraction, nuclease digestion, ultracentrifugation, and repeated ethanol extractions. In this study, we evaluated size exclusion chromatography for effectively eliminating nucleic acid contamination while purifying high molecular weight cell surface-associated polysaccharides. Post-initial extraction, the nucleic acid content remains significantly elevated, and kinetic analysis reveals that DNase I and RNase A digestion is neither economically viable nor effective for removing these contaminants. Employing an appropriate size exclusion resin removes over 99 % of nucleic acid contamination, as confirmed by nucleic acid content analysis and agarose gel electrophoresis. Purity and structural analysis using 1H 1D-NMR and 2D-NMR demonstrate that the cell surface-associated polysaccharide purified with this study is highly homogeneous and identified as antigenic O-polysaccharide. This approach streamlines the purification process by removing the need for nuclease digestion and additional ethanol precipitation steps.

60 APPLIED LIFE SCIENCES↗

Groundwater recharge mechanism in an integrated tableland of the Loess Plateau, northern China: insights from environmental tracers

Assessing groundwater recharge characteristics (recharge rate, history, mechanisms (piston and preferential flow)) and groundwater age in arid and semi-arid environments remains a difficult but important research frontier. Such assessments are particularly important when the unsaturated zone (UZ) is thick and the recharge rate is limited. This study combined evaluations of the thick UZ with those of the saturated zone and used multiple tracers, such as Cl, NO{sub 3}, Br, {sup 2}H, {sup 18}O, {sup 13}C, {sup 3}H and {sup 14}C, to study groundwater recharge characteristics in an integrated loess tableland in the Loess Plateau, China, where precipitation infiltration is the only recharge source for shallow groundwater. The results indicate that diffuse recharge beneath crops, as the main land use of the study area, is 55–71 mm yr{sup −1} based on the chloride mass balance of soil profiles. The length of time required for annual precipitation to reach the water table is 160–400 yrs. The groundwater is all pre-modern water and paleowater, with corrected {sup 14}C age ranging from 136 to 23,412 yrs. Most of the water that eventually becomes recharge originally infiltrated in July–September. The Cl and NO{sub 3} contents in the upper UZ are considerably higher than those in the deep UZ and shallow groundwater because of recent human activities. The shallow groundwater has not been in hydraulic equilibrium with present near-surface boundary conditions. The homogeneous material of the UZ and relatively old groundwater age imply that piston flow is the dominant recharge mechanism for the shallow groundwater in the tableland.

58 GEOSCIENCES↗

Evaluation of an Al-Ce alloy for laser additive manufacturing

Our present research in metal additive manufacturing (AM) focuses on designing processing parameters around existing alloys designed for traditional manufacturing. However, to maximize the benefits of AM, alloys should be designed to specifically take advantage of the unique thermal conditions of these processes. Furthermore, our study focuses on the development of a design methodology for alloys in AM, using a newly developed Al-Ce alloy as an initial case study. To evaluate the candidacy of this system for fusion based additive manufacturing, single-line laser melts were made on cast Al-12Ce plates using three different beam velocities (100, 200, and 300 mm/min). The microstructure was evaluated in the as-melted and heat treated conditions (24 hrs at 300°C). An extremely fine microstructure was observed within the weld pools, evolving from eutectic at the outer solid-liquid boundaries to a primary Al FCC dendritic/cellular structure nearer the melt-pool centerline. We rationalized the observed microstructures through the construction of a microstructure selection map for the Al-Ce binary system, which will be used to enable future alloy design. Interestingly, the heat treated samples exhibited no microstructural coarsening.

36 MATERIALS SCIENCE↗