Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

WE-D-18A-05: Construction of Realistic Liver Phantoms From Patient Images and a Commercial 3D Printer

Purpose: To assess image quality and radiation dose reduction in abdominal CT imaging, physical phantoms having realistic background textures and lesions are highly desirable. The purpose of this work was to construct a liver phantom with realistic background and lesions using patient CT images and a 3D printer. Methods: Patient CT images containing liver lesions were segmented into liver tissue, contrast-enhanced vessels, and liver lesions using commercial software (Mimics, Materialise, Belgium). Stereolithography (STL) files of each segmented object were created and imported to a 3D printer (Object350 Connex, Stratasys, MN). After test scans were performed to map the eight available printing materials into CT numbers, printing materials were assigned to each object and a physical liver phantom printed. The printed phantom was scanned on a clinical CT scanner and resulting images were compared with the original patient CT images. Results: The eight available materials used to print the liver phantom had CT number ranging from 62 to 117 HU. In scans of the liver phantom, the liver lesions and veins represented in the STL files were all visible. Although the absolute value of the CT number in the background liver material (approx. 85 HU) was higher than in patients (approx. 40 HU), the difference in CT numbers between lesions and background were representative of the low contrast values needed for optimization tasks. Future work will investigate materials with contrast sufficient to emulate contrast-enhanced arteries. Conclusion: Realistic liver phantoms can be constructed from patient CT images using a commercial 3D printer. This technique may provide phantoms able to determine the effect of radiation dose reduction and noise reduction techniques on the ability to detect subtle liver lesions in the context of realistic background textures.

60 APPLIED LIFE SCIENCES↗

WE-E-18A-04: Precision In-Vivo Dosimetry Using Optically Stimulated Luminescence Dosimeters and a Pulsed-Stimulating Dose Reader

Purpose: A new readout technology based on pulsed optically stimulating luminescence is introduced (microSTARii, Landauer, Inc, Glenwood, IL60425). This investigation searches for approaches that maximizes the dosimetry accuracy in clinical applications. Methods: The sensitivity of each optically stimulated luminescence dosimeter (OSLD) was initially characterized by exposing it to a given radiation beam. After readout, the luminescence signal stored in the OSLD was erased by exposing its sensing area to a 21W white LED light for 24 hours. A set of OSLDs with consistent sensitivities was selected to calibrate the dose reader. Higher order nonlinear curves were also derived from the calibration readings. OSLDs with cumulative doses below 15 Gy were reused. Before an in-vivo dosimetry, the OSLD luminescence signal was erased with the white LED light. Results: For a set of 68 manufacturer-screened OSLDs, the measured sensitivities vary in a range of 17.3%. A sub-set of the OSLDs with sensitivities within ±1% was selected for the reader calibration. Three OSLDs in a group were exposed to a given radiation. Nine groups were exposed to radiation doses ranging from 0 to 13 Gy. Additional verifications demonstrated that the reader uncertainty is about 3%. With an external calibration function derived by fitting the OSLD readings to a 3rd-order polynomial, the dosimetry uncertainty dropped to 0.5%. The dose-luminescence response curves of individual OSLDs were characterized. All curves converge within 1% after the sensitivity correction. With all uncertainties considered, the systematic uncertainty is about 2%. Additional tests emulating in-vivo dosimetry by exposing the OSLDs under different radiation sources confirmed the claim. Conclusion: The sensitivity of individual OSLD should be characterized initially. A 3rd-order polynomial function is a more accurate representation of the dose-luminescence response curve. The dosimetry uncertainty specified by the manufacturer is 4%. Following the proposed approach, it can be controlled to 2%.

60 APPLIED LIFE SCIENCES↗

Impact of CT attenuation correction method on quantitative respiratory-correlated (4D) PET/CT imaging

Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by the patient-specific respiratory waveforms; when testing patient and sinusoidal waveforms separately, patient waveforms were significantly different between phases (p < 0.0001) while the sinusoidal waveforms were not significantly different (p = 0.98). When considering only the subset of 4DMATCH images that corresponded to the end-exhale image phase, 4DEXH, mean and interquartile range were similar to 4DMATCH but variability was considerably reduced. Conclusions: Comparative advantages in accuracy and precision of SUV metrics and segmented volumes were demonstrated with the use of the maximum intensity projection and end-exhale CT attenuation correction. While respiratory phase-matched CTAC should in theory provide optimal corrections, image artifacts and differences in implementation of 4DCT and 4DPET sorting can degrade the benefit of this approach. These results may be useful to guide the implementation, analysis, and development of respiratory-correlated thoracic PET/CT in the radiation oncology and diagnostic settings.

60 APPLIED LIFE SCIENCES↗

Prospective estimation of organ dose in CT under tube current modulation

Purpose: Computed tomography (CT) has been widely used worldwide as a tool for medical diagnosis and imaging. However, despite its significant clinical benefits, CT radiation dose at the population level has become a subject of public attention and concern. In this light, optimizing radiation dose has become a core responsibility for the CT community. As a fundamental step to manage and optimize dose, it may be beneficial to have accurate and prospective knowledge about the radiation dose for an individual patient. In this study, the authors developed a framework to prospectively estimate organ dose for chest and abdominopelvic CT exams under tube current modulation (TCM). Methods: The organ dose is mainly dependent on two key factors: patient anatomy and irradiation field. A prediction process was developed to accurately model both factors. To model the anatomical diversity and complexity in the patient population, the authors used a previously developed library of computational phantoms with broad distributions of sizes, ages, and genders. A selected clinical patient, represented by a computational phantom in the study, was optimally matched with another computational phantom in the library to obtain a representation of the patient’s anatomy. To model the irradiation field, a previously validated Monte Carlo program was used to model CT scanner systems. The tube current profiles were modeled using a ray-tracing program as previously reported that theoretically emulated the variability of modulation profiles from major CT machine manufacturers Li et al., [Phys. Med. Biol. 59, 4525–4548 (2014)]. The prediction of organ dose was achieved using the following process: (1) CTDI{sub vol}-normalized-organ dose coefficients (h{sub organ}) for fixed tube current were first estimated as the prediction basis for the computational phantoms; (2) each computation phantom, regarded as a clinical patient, was optimally matched with one computational phantom in the library; (3) to account for the effect of the TCM scheme, a weighted organ-specific CTDI{sub vol} [denoted as (CTDI{sub vol}){sub organ,weighted}] was computed for each organ based on the TCM profile and the anatomy of the “matched” phantom; (4) the organ dose was predicted by multiplying the weighted organ-specific CTDI{sub vol} with the organ dose coefficients (h{sub organ}). To quantify the prediction accuracy, each predicted organ dose was compared with the corresponding organ dose simulated from the Monte Carlo program with the TCM profile explicitly modeled. Results: The predicted organ dose showed good agreements with the simulated organ dose across all organs and modulation profiles. The average percentage error in organ dose estimation was generally within 20% across all organs and modulation profiles, except for organs located in the pelvic and shoulder regions. For an average CTDI{sub vol} of a CT exam of 10 mGy, the average error at full modulation strength (α = 1) across all organs was 0.91 mGy for chest exams, and 0.82 mGy for abdominopelvic exams. Conclusions: This study developed a quantitative model to predict organ dose for clinical chest and abdominopelvic scans. Such information may aid in the design of optimized CT protocols in relation to a targeted level of image quality.

60 APPLIED LIFE SCIENCES↗

Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring

Purpose: External beam radiotherapy with protons and heavier ions enables a tighter conformation of the applied dose to arbitrarily shaped tumor volumes with respect to photons, but is more sensitive to uncertainties in the radiotherapeutic treatment chain. Consequently, an independent verification of the applied treatment is highly desirable. For this purpose, the irradiation-induced β{sup +}-emitter distribution within the patient is detected shortly after irradiation by a commercial full-ring positron emission tomography/x-ray computed tomography (PET/CT) scanner installed next to the treatment rooms at the Heidelberg Ion-Beam Therapy Center (HIT). A major challenge to this approach is posed by the small number of detected coincidences. This contribution aims at characterizing the performance of the used PET/CT device and identifying the best-performing reconstruction algorithm under the particular statistical conditions of PET-based treatment monitoring. Moreover, this study addresses the impact of radiation background from the intrinsically radioactive lutetium-oxyorthosilicate (LSO)-based detectors at low counts. Methods: The authors have acquired 30 subsequent PET scans of a cylindrical phantom emulating a patientlike activity pattern and spanning the entire patient counting regime in terms of true coincidences and random fractions (RFs). Accuracy and precision of activity quantification, image noise, and geometrical fidelity of the scanner have been investigated for various reconstruction algorithms and settings in order to identify a practical, well-suited reconstruction scheme for PET-based treatment verification. Truncated listmode data have been utilized for separating the effects of small true count numbers and high RFs on the reconstructed images. A corresponding simulation study enabled extending the results to an even wider range of counting statistics and to additionally investigate the impact of scatter coincidences. Eventually, the recommended reconstruction scheme has been applied to exemplary postirradiation patient data-sets. Results: Among the investigated reconstruction options, the overall best results in terms of image noise, activity quantification, and accurate geometrical recovery were achieved using the ordered subset expectation maximization reconstruction algorithm with time-of-flight (TOF) and point-spread function (PSF) information. For this algorithm, reasonably accurate (better than 5%) and precise (uncertainty of the mean activity below 10%) imaging can be provided down to 80 000 true coincidences at 96% RF. Image noise and geometrical fidelity are generally improved for fewer iterations. The main limitation for PET-based treatment monitoring has been identified in the small number of true coincidences, rather than the high intrinsic random background. Application of the optimized reconstruction scheme to patient data-sets results in a 25% − 50% reduced image noise at a comparable activity quantification accuracy and an improved geometrical performance with respect to the formerly used reconstruction scheme at HIT, adopted from nuclear medicine applications. Conclusions: Under the poor statistical conditions in PET-based treatment monitoring, improved results can be achieved by considering PSF and TOF information during image reconstruction and by applying less iterations than in conventional nuclear medicine imaging. Geometrical fidelity and image noise are mainly limited by the low number of true coincidences, not the high LSO-related random background. The retrieved results might also impact other emerging PET applications at low counting statistics.

60 APPLIED LIFE SCIENCES↗

SU-E-T-165: Characterization of Dose Distributions in High-Dose-Rate Surface Brachytherapy

Purpose: To characterize dose distributions in high-dose-rate(HDR) surface brachytherapy using an Ir-125 source for different geometries, field sizes and topology of the clinical targets(CT). To investigate the depth doses at the central axis(CAX), edges of the treatment fields(E), and lateral dose distributions(L) present when using flap applicators in skin cancer treatments. Methods: When malignancies diagnosed on the skin are treated, various geometries of the CT require proper adaptation of the flap or custom-made applicators to the treatment site. Consequently, the dose at the depth on CAX and field edges changes with variation of the curvatures and size of the applicators. To assess the dose distributions, we created a total of 10 treatment plans(TP) for 10×10 and 20×20 field sizes(FS) with a step size of 1cm. The geometry of the applicators was: planar(PA), curved to 30(CA30) and 60(CA60) degrees with respect to the CAX, half-cylinder(HC), and cylindrical shape(CS). One additional TP was created in which the applicators were positioned to form a dome shape(DS) with a diameter of 16cm. This TP was used to emulate treatment of the average sized scalp. All TPs were optimized to deliver a prescription dose at 8mm equidistantly from the planes containing the dwell positions. This optimization is equivalent to the clinical arrangement since the SSD for the flap applicators is 5mm and the prescription depth is 3mm in the majority of clinical cases. Results: The depths (in mm) of the isodose lines were: FS(10×10):PA[90%(9.1CAX,8.0E,7.6L),50%(28.3CAX,20E,17.3L), 25%(51.1CAX,40E,27L)],CA30[90%(10.3CAX,8.2E,7.9L),50%(32.1CAX, 16.2E,15.8L),25%(61.3CAX,36.7E,31.8L)],CA60[90%(12.2CAX,6.1E,6.3L ),50%(47CAX,14E,16.6L),25%(70.8CAX,31.9E,35.4L)],HC[90%(11.1CA X,6.3E,7.3L),50%(38.3CAX,14.6E,16.1L),25%(66.2CAX,33.8E,34.2L)];FS (20×20):PA[90%(11.1CAX,9.0E,7.0L),50%(34.4CAX,21.9E,15.3L),25%(7 0.4CAX,50.9E,34.8L)],CA30[90%(10.9CAX,7.5E,7.1L),50%(38.8CAX,16. 7E,15.4L),25%(80.7CAX,39.9E,35.7L)],HC[90%(11.1CAX,10.9E,10.6L),5 0%(34.4CAX,38.8E,47.2L),25%(70.4CAX,80.7E,96.6L);DS[90%(12.1CA X,8.5E,6.8L),50%(60.6CAX,17.7E,15.8L),25%(109.6CAX,40.3E,34.3L)]. Conclusion: These results can be used for the approximate calculation and quick assessment of the radiation dose to the organs-at-risk at depth (heart,brain,thyroid, optical nerve) or at the surface distance from the CT (breast,eyes, gonads), and only the geometry of the CT needs to be measured. Understanding of the dose distributions in HDR surface brachytherapy may improve clinical decision making process.

60 APPLIED LIFE SCIENCES↗

TU-CD-304-02: Planning and Delivery of Fully Dynamic Trajectory Modulated Arc Therapy On Pituitary Adenoma: Dosimetric Advantages Over Conventional Volumetric Modulated Arc Therapy

Purpose: To assess the potential benefit of trajectory modulated arc therapy (TMAT) for treatments of small benign intracranial tumor, pituitary adenoma. Methods: A TMAT planning platform that incorporates complex source motion trajectory involving synchronized gantry rotation with translational and rotational couch movement was used for the study. The platform couples an interactive trajectory generation tool with a VMAT algorithm that performs multi-resolution, progressive sampling MLC optimization on a user-designed trajectory. A continuous couch rotation of 160° angular span with ±20° mini gantry arcs was used to emulate a non-coplanar horizontal arc-like trajectory. Compared to conventional non-coplanar gantry arcs (60°-100° gantry rotation with couch kicks), TMAT limited the unnecessary low to medium dose spread in the anterior and posterior directions, where primary OARs (e.g., brainstem, optic chiasm, optic nerves, and lens) are in close proximity to the targeted pituitary tumor volume. For 5 standard fractionation pituitary adenoma cases (50.4Gy/28fractions), TMAT and non-coplanar VMAT plans were generated and compared under equivalent objectives/constraints. TMAT delivery was implemented and demonstrated on Varian TrueBeam via XML scripts. Results: Both techniques showed good target coverage while OARs were able to meet the constraints on QUANTEC guidelines. Notably, TMAT decreased the dose deposition in the anterior-to-posterior direction surrounding PTV. TMAT significantly reduced the mean doses on brainstem, optic nerves, eyes and lens by 47.29%±13.17%, 28.51%±8.68%, 80.82%±8.71% and 65.38%±19.99% compared with VMAT, all p≤0.01. Percentage reductions of maximum point dose in eyes and lens were 75.68%±10.30% and 70.72%±18.62% respectively for TMAT versus VMAT, all p≤0.01. A representative isocentric TMAT pituitary plan was delivered via an XML script with 200 control points and 282 MUs. Conclusion: Deliverable TMAT plans were achieved in developer mode in TrueBeam. TMAT was shown to be superior for pituitary adenoma irradiation in terms of OARs sparing.

60 APPLIED LIFE SCIENCES↗

TU-G-204-04: A Unified Strategy for Bi-Factorial Optimization of Radiation Dose and Contrast Dose in CT Imaging

Purpose: To substantiate the interdependency of contrast dose, radiation dose, and image quality in CT towards the patient- specific optimization of the imaging protocols Methods: The study deployed two phantom platforms. A variable sized (12, 18, 23, 30, 37 cm) phantom (Mercury-3.0) containing an iodinated insert (8.5 mgI/ml) was imaged on a representative CT scanner at multiple CTDI values (0.7–22.6 mGy). The contrast and noise were measured from the reconstructed images for each phantom diameter. Linearly related to iodine-concentration, contrast-to-noise ratio (CNR), were calculated for 16 iodine-concentration levels (0–8.5 mgI/ml). The analysis was extended to a recently developed suit of 58 virtual human models (5D XCAT) with added contrast dynamics. Emulating a contrast-enhanced abdominal image procedure and targeting a peak-enhancement in aorta, each XCAT phantom was “imaged” using a simulation platform (CatSim, GE). 3D surfaces for each patient/size established the relationship between iodine-concentration, dose, and CNR. The ratios of change in iodine-concentration versus dose (IDR) to yield a constant change in CNR were calculated for each patient size. Results: Mercury phantom results show the image-quality size- dependence on CTDI and IC levels. For desired image-quality values, the iso-contour-lines reflect the trade off between contrast-material and radiation doses. For a fixed iodine-concentration (4 mgI/mL), the IDR values for low (1.4 mGy) and high (11.5 mGy) dose levels were 1.02, 1.07, 1.19, 1.65, 1.54, and 3.14, 3.12, 3.52, 3.76, 4.06, respectively across five sizes. The simulation data from XCAT models confirmed the empirical results from Mercury phantom. Conclusion: The iodine-concentration, image quality, and radiation dose are interdependent. The understanding of the relationships between iodine-concentration, image quality, and radiation dose will allow for a more comprehensive optimization of CT imaging devices and techniques, providing the methodology to balance iodine-concentration and dose based on patient’s attributes.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-J-05: Fast Volumetric MRI On An MRI-Linac Enables On-Line QA On Dose Deposition in the Patient

Purpose: The introduction of the MRI-linac in radiotherapy brings MRI-guided treatment with daily plan adaptions within reach. This paradigm demands on-line QA. With its ability to perform continuous volumetric imaging in an outstanding soft-tissue contrast, the MRI- linac promises to elucidate the dose deposition process during a treatment session. Here we study for a prostate case how dynamic MRI combined with linac machine parameters and a fast dose-engine can be used for on-line dose accumulation. Methods: Prostate imaging was performed in healthy volunteer on a 1.5T MR-scanner (Philips, Best, NL) according to a clinical MR-sim protocol, followed by 10min of dynamic imaging (FLASH, 4s/volume, FOV 40×40×12cm{sup 3}, voxels 3×3×3mm{sup 3}, TR/TE/α=3.5ms/1.7ms/5°). An experienced radiation oncologist made delineations, considering the prostate CTV. Planning was performed on a two-compartment pseudoCT (air/water density) according to clinical constraints (77Gy in PTV) using a Monte-Carlo (MC) based TPS that accounts for magnetic fields. Delivery of one fraction (2.2Gy) was simulated on an emulator for the Axesse linac (Elekta, Stockholm, SE). Machine parameters (MLC settings, gantry angle, dose rate, etc.) were recorded at 25Hz. These were re-grouped per dynamic volume and fed into the MC-engine to calculate a dose delivered for each of the dynamics. Deformations derived from non-rigid registration of each dynamic against the first allowed dose accumulation on a common reference grid. Results: The DVH parameters on the PTV compared to the optimized plan showed little changes. Local deformations however resulted in local deviations, primarily around the air/rectum interface. This clearly indicates the potential of intra-fraction adaptations based on the accumulated dose. Application in each fraction helps to track the influence of plan adaptations to the eventual dose distribution. Calculation times were about twice the delivery time. Conclusion: The current Result paves the way to perform on-line treatment delivery QA on the MRI-linac in the near future.

60 APPLIED LIFE SCIENCES↗

WE-D-303-02: Applications of Volumetric Images Generated with a Respiratory Motion Model Based On An External Surrogate Signal

Purpose: Respiratory motion can vary significantly over the course of simulation and treatment. Our goal is to use volumetric images generated with a respiratory motion model to improve the definition of the internal target volume (ITV) and the estimate of delivered dose. Methods: Ten irregular patient breathing patterns spanning 35 seconds each were incorporated into a digital phantom. Ten images over the first five seconds of breathing were used to emulate a 4DCT scan, build the ITV, and generate a patient-specific respiratory motion model which correlated the measured trajectories of markers placed on the patients’ chests with the motion of the internal anatomy. This model was used to generate volumetric images over the subsequent thirty seconds of breathing. The increase in the ITV taking into account the full 35 seconds of breathing was assessed with ground-truth and model-generated images. For one patient, a treatment plan based on the initial ITV was created and the delivered dose was estimated using images from the first five seconds as well as ground-truth and model-generated images from the next 30 seconds. Results: The increase in the ITV ranged from 0.2 cc to 6.9 cc for the ten patients based on ground-truth information. The model predicted this increase in the ITV with an average error of 0.8 cc. The delivered dose to the tumor (D95) changed significantly from 57 Gy to 41 Gy when estimated using 5 seconds and 30 seconds, respectively. The model captured this effect, giving an estimated D95 of 44 Gy. Conclusion: A respiratory motion model generating volumetric images of the internal patient anatomy could be useful in estimating the increase in the ITV due to irregular breathing during simulation and in assessing delivered dose during treatment. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc. and Radiological Society of North America Research Scholar Grant #RSCH1206.

60 APPLIED LIFE SCIENCES↗

Population of 224 realistic human subject-based computational breast phantoms

Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was then applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range of breast types, volumes, densities, and parenchymal patterns.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-R-39: Effects of Radiation Dose Reduction On Renal Cell Carcinoma Discrimination Using Multi-Phasic CT Imaging

Purpose: A method to discriminate different types of renal cell carcinoma (RCC) was developed using attenuation values observed in multiphasic contrast-enhanced CT. This work evaluates the sensitivity of this RCC discrimination task at different CT radiation dose levels. Methods: We selected 5 cases of kidney lesion patients who had undergone four-phase CT scans covering the abdomen to the lilac crest. Through an IRB-approved study, the scans were conducted on 64-slice CT scanners (Definition AS/Definition Flash, Siemens Healthcare) using automatic tube-current modulation (TCM). The protocol included an initial baseline unenhanced scan, followed by three post-contrast injection phases. CTDIvol (32 cm phantom) measured between 9 to 35 mGy for any given phase. As a preliminary study, we limited the scope to the cortico-medullary phase—shown previously to be the most discriminative phase. A previously validated method was used to simulate a reduced dose acquisition via adding noise to raw CT sinogram data, emulating corresponding images at simulated doses of 50%, 25%, and 10%. To discriminate the lesion subtype, ROIs were placed in the most enhancing region of the lesion. The mean HU value of an ROI was extracted and used to discriminate to the worst-case RCC subtype, ranked in the order of clear cell, papillary, chromophobe and the benign oncocytoma. Results: Two patients exhibited a change of worst case RCC subtype between original and simulated scans, at 25% and 10% doses. In one case, the worst-case RCC subtype changed from oncocytoma to chromophobe at 10% and 25% doses, while the other case changed from oncocytoma to clear cell at 10% dose. Conclusion: Based on preliminary results from an initial cohort of 5 patients, worst-case RCC subtypes remained constant at all simulated dose levels except for 2 patients. Further study conducted on more patients will be needed to confirm our findings. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH Grant Support from: U01 CA181156.

60 APPLIED LIFE SCIENCES↗

TU-H-207A-02: Relative Importance of the Various Factors Influencing the Accuracy of Monte Carlo Simulated CT Dose Index

Purpose: Monte Carlo simulation is a frequently used technique for assessing patient dose in CT. The accuracy of a Monte Carlo program is often validated using the standard CT dose index (CTDI) phantoms by comparing simulated and measured CTDI{sub 100}. To achieve good agreement, many input parameters in the simulation (e.g., energy spectrum and effective beam width) need to be determined. However, not all the parameters have equal importance. Our aim was to assess the relative importance of the various factors that influence the accuracy of simulated CTDI{sub 100}. Methods: A Monte Carlo program previously validated for a clinical CT system was used to simulate CTDI{sub 100}. For the standard CTDI phantoms (32 and 16 cm in diameter), CTDI{sub 100} values from central and four peripheral locations at 70 and 120 kVp were first simulated using a set of reference input parameter values (treated as the truth). To emulate the situation in which the input parameter values used by the researcher may deviate from the truth, additional simulations were performed in which intentional errors were introduced into the input parameters, the effects of which on simulated CTDI{sub 100} were analyzed. Results: At 38.4-mm collimation, errors in effective beam width up to 5.0 mm showed negligible effects on simulated CTDI{sub 100} (<1.0%). Likewise, errors in acrylic density of up to 0.01 g/cm{sup 3} resulted in small CTDI{sub 100} errors (<2.5%). In contrast, errors in spectral HVL produced more significant effects: slight deviations (±0.2 mm Al) produced errors up to 4.4%, whereas more extreme deviations (±1.4 mm Al) produced errors as high as 25.9%. Lastly, ignoring the CT table introduced errors up to 13.9%. Conclusion: Monte Carlo simulated CTDI{sub 100} is insensitive to errors in effective beam width and acrylic density. However, they are sensitive to errors in spectral HVL. To obtain accurate results, the CT table should not be ignored. This work was supported by a Faculty Research and Development Award from Cleveland State University.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP2-03: Development of 3D Printed Coronary Phantoms for In-Vitro CT-FFR Validation Using Data from 320- Detector Row Coronary CT Angiography

Purpose: To validate Computed Tomography Fractional Flow Reserve (CT-FFR) measurements with accurate 3D printed coronary phantoms. Methods: DICOM data from four phases in two patients imaged with a standard 320 × 0.5mm coronary CT acquisition (70–80% cardiac cycle) underwent semi-automated segmentation using a research workstation. Both patients had a >50% stenosis from the clinical image interpretation. Each volume was saved as a Stereo Lithographic (STL) file with 250 micron resolution. The 3D geometries were qualitatively assessed; the best of the four phases was 3D printed using a Stratasys Eden260V printer in Tango+, a rubber-like material that roughly emulates mechanical properties of human vasculature. We connected the model to a programmable pump and measured the pressure drop using pressure sensors embedded proximal and distal to the arterial stenosis. Next, the STL files used for the 3D printed models were uploaded in the ANSYS meshing tool (ICEM CFD 16.1). A standard meshing process was applied and the meshed geometry was directly imported in the ANSYS Fluent for Computational Flow Dynamics simulations. The CFD simulations were used to calculate the CT-FFR and compared to the bench top FFR measured in the 3D printed phantoms. Results: FFR-CT measurements and phantoms were completed in within an hour after the segmentation. Patient 1 had a 60% stenosis that resulted in a CT-FFR of 0.68. The second case had a 50% stenosis and a CT-FFR of 0.75. The average bench top FFR measurements were 0.72 and 0.80, respectively. Conclusion: This pilot investigation demonstrated the use of a bench-top coronary model for CT-FFR validation. The measurements and the CFD simulations agreed within 6%. Project supported by Support: Toshiba America Medical Systems Corp.and NIH grant R01-EB002873. Project supported by Toshiba America Medical Systems Corp.and partial support from NIH grant R01-EB002873.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-TeP3-04: Probing the Dose Enhancement Due to a Clinically-Relevant Concentration of Gold Nanoparticles and Yb-169 Gamma Rays Using PRESAGE Dosimeters

Purpose: To probe physical evidences of the dose enhancement due to a low/clinically-relevant concentration of gold nanoparticles (GNPs) and Yb-169 gamma rays using PRESAGE dosimeters. Methods: A PRESAGE cuvette was placed at approximately 2 mm above the plane containing three novel Yb-169 brachytherapy seeds (3.2, 3.2, and 5.3 mCi each). Two types of PRESAGE dosimeters were used – plain PRESAGEs (controls) and PRESAGEs loaded with 0.02 wt. % of GNPs (GNP-PRESAGEs). Each PRESAGE dosimeter was irradiated with different time durations (0 to 24 hours) to deliver 0, 4, 8, 16 and 24 Gy of dose. For a reference/comparison, both types of PRESAGEs were also irradiated using 250 kVp x-rays with/without Er-filter to deliver 0, 3, 10, and 30 Gy of dose. Er-filter was used to emulate Yb-169 spectrum using 250 kVp x-rays. The absorption spectra of PRESAGEs were measured using a UV spectrophotometer and used to determine the corresponding optical densities (ODs). Results: GNP-PRESAGEs exposed to Yb-169 sources showed ∼65% increase in ODs compared with controls. When exposed to Er-filtered and unfiltered 250 kVp x-rays, they produced smaller increases in ODs, ∼41% and ∼37%, respectively. There was a linear relationship between ODs and delivered doses with a goodness-of-fit (R2) greater than 0.99. Conclusion: A notable increase in the ODs (∼65%) was observed for GNP-PRESAGEs irradiated by Yb-169 gamma rays. Considering the observed OD increases, it was highly likely that Yb-169 gamma rays were more effective than both Er-filtered and unfiltered 250 kVp x-rays, in terms of producing the dose enhancement. Due to several unknown factors (e.g., possible difference in the dose response of GNP-PRESAGEs vs. PRESAGEs), however, a further investigations is necessary to establish the feasibility of quantifying the exact amount of macroscopic or microscopic/local GNP-mediated dose enhancement using PRESAGE or similar volumetric dosimeters. Supported by DOD/PCRP grant W81XWH-12-1-0198 This investigation was supported by DOD/PCRP grant W81XWH-12-1-0198.

60 APPLIED LIFE SCIENCES↗

TH-CD-202-12: Online Inter-Beam Replanning Based On Real-Time Dose Reconstruction

Purpose: This work provides a proof-of-concept study for online replanning during treatment delivery for step-and-shoot prostate SBRT, based on real-time dose reconstruction. Online replanning is expected to improve the trade-off between target coverage and organ-at-risk dose in the presence of intra-fractional motion. Methods: We have implemented an online replanning workflow on top of our previously reported real-time dose reconstruction software which connects to an Elekta research linac. The treatment planning system DynaPlan was extended to (1) re-optimize and sequence treatment plans (in clockwise beam order) before each beam, based on actual delivered dose, in a timeframe limited by the gantry rotation between subsequent beams, and (2) send the respective segments to the delivery control software DynaTrack which starts/continues treatment immediately.To investigate the impact of a reduced safety margin, we have created and delivered (on a linac emulator) a conventional CTV+5/3mm (I) and a reduced CTV+1mm margin (II) treatment plan for a prostate patient. We have assessed CTV coverage with and without inter-beam replanning, all exposed to a gradual target shift of 0–5mm in posterior and inferior direction from start until the end of delivery. Results: For the reconstructed conventional plan (I), D98 for CTV was 100% of D98 of the planned dose. For the reconstructed margin-reduced plan (II), D98 for CTV was 95% of the planned D98 without replanning, but could be recovered to 99% by replanning for each beam. Plan (II) with replanning resulted in a decrease for bladder V90% by 88% and an increase to rectum V90% by 9% compared to the conventional plan (I). Dose calculation/accumulation was performed in <15ms per MLC aperture, replanning in <15s per beam. Conclusion: We have shown that online inter-beam replanning is technically feasible and potentially allows for a margin reduction. Future investigation considering motion-robust replanning optimization parameters is in progress. We acknowledge support of the MLC research from Elekta AB. This work is supported by Cancer Research UK under Programme C33589/A19908. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR.

60 APPLIED LIFE SCIENCES↗

Estimating scatter in cone beam CT with striped ratio grids: A preliminary investigation

Purpose: To propose a new method for estimating scatter in x-ray imaging. Conventional antiscatter grids reject scatter at an efficiency that is constant or slowly varying over the surface of the grid. A striped ratio antiscatter grid, composed of stripes that alternate between high and low grid ratio, could be used instead. Such a striped ratio grid would reduce scatter-to-primary ratio as a conventional grid would, but more importantly, the signal discontinuities at the boundaries of stripes can be used to estimate local scatter content. Methods: Signal discontinuities provide information on scatter, but are contaminated by variation in primary radiation. A nonlinear image processing algorithm is used to estimate the scatter content in the presence of primary variation. We emulated a striped ratio grid by imaging phantoms with two sequential CT scans, one with and one without a conventional grid. These two scans are processed together to mimic a striped ratio grid. This represents a best case limit of the striped ratio grid, in that the extent of grid ratio modulation is very high and the scatter contrast is maximized. Results: In a uniform cylinder, the striped ratio grid virtually eliminates cupping. Artifacts from scatter are improved in an anthropomorphic phantom. Some banding artifacts are induced by the striped ratio grid. Conclusions: Striped ratio grids could be a simple and effective evolution of conventional antiscatter grids. Construction and validation of a physical prototype remains an important future step.

60 APPLIED LIFE SCIENCES↗

Demonstration of a third-order hierarchy of topological states in a three-dimensional acoustic metamaterial

Classical wave systems have constituted an excellent platform for emulating complex quantum phenomena, such as demonstrating topological phenomena in photonics and acoustics. Recently, a new class of topological states localized in more than one dimension of a D -dimensional system, referred to as higher-order topological (HOT) states, has been reported, offering an even more versatile platform to confine and control classical radiation and mechanical motion. Here, we design and experimentally study a 3D topological acoustic metamaterial supporting third-order (0D) topological corner states along with second-order (1D) edge states and first-order (2D) surface states within the same topological bandgap, thus establishing a full hierarchy of nontrivial bulk polarization–induced states in three dimensions. The assembled 3D topological metamaterial represents the acoustic analog of a pyrochlore lattice made of interconnected molecules, and is shown to exhibit topological bulk polarization, leading to the emergence of boundary states.

Science & Technology - Other Topics↗