Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

The effects of well damage and completion designs on geoelectrical responses in mature wellbore environments

Well integrity is one of the major concerns in long-term geologic storage sites due to the potential risk of well leakage and groundwater contamination. Evaluating changes in electrical responses due to energized steel-cased wells has the potential to quantify and predict possible wellbore failures because any kind of breakage or corrosion along highly conductive well casings will have an impact on the distribution of the subsurface electrical potential. However, realistic wellbore-geoelectrical models that can fully capture fine-scale details of well completion design and the state of well damage at the field scale require extensive computational effort, or they can even be intractable to simulate. To overcome this computational burden while still keeping the model realistic, we have used the hierarchical finite-element method that represents electrical conductivity at each dimensional component (1D edges, 2D planes, and 3D cells) of a tetrahedral mesh. This allows well completion designs with real-life geometric scales and well systems with realistic, detailed, progressive corrosion and damage in our models. We have developed a comparison of possible discretization approaches of a multicasing completion design in the finite-element model. The effects of the surface casing and the coupling between concentric well casings as well as the effects of the degree and the location of well damage on the electrical responses are also examined. As a result, we analyze real surface electric field data to detect wellbore integrity failure associated with damage.

58 GEOSCIENCES↗

Will Solar Panels Help When the Power Goes Out? Planning for PV Resilience

PV systems, like all energy systems, must chart a difficult course in order to improve resilience. They need to simultaneously withstand extreme conditions that cause grid power disruptions, be configured in a way that allows electricity to be delivered to meet the PV user's needs, and overcome disruptions arising from solar resource intermittency. Certain considerations reveal themselves as key to a PV system's resilience benefits. Choice of hardware is critical, as is site selection for the PV array. Voluminous evidence in a hurricane context demonstrates that durable hardware, properly maintained and sited, leads to PV systems surviving extreme weather with their functionality intact. Structurally weak or poorly maintained PV equipment, on the other hand, has demonstrated failures during extreme weather events. PV system stakeholders should ensure that best practices are followed for hardware procurement and siting. It is also important to understand that PV systems are not one-size-fits-all. While incorporating islanding capabilities and energy storage into the system's electrical topology will typically enhance resilience, the user's needs will determine the optimally resilient conformation of any given system. These factors - appropriate hardware, siting, maintenance, and system design - are the primary drivers of PV resilience. PV systems possess high potential for resilient energy generation due to their distributed, abundant, and free fuel supply, but the technology itself does not inherently lead to resilient outcomes. Realizing PV's potential for resilience requires consideration of these determinative factors.

14 SOLAR ENERGY↗

Bioinspired mechanically interlocking holey graphene@SiO 2 anode

Mechanically interlocking structures that can enhance adhesion at the interface and regulate the stress distribution have been widely observed in biological systems. Inspired by the biological structures in the wings of beetles, we synthesized a holey graphene@SiO 2 anode with strong mechanical interlocking, characterized it electrochemically, and explained its performance by finite element analysis and density functional calculations. The mechanically interlocking structure enhances lithium-ion (Li + ) storage by transmitting the strain from SiO 2 to the holey graphene and by a mechano-electrochemical coupling effect. The interlocking fit hinders the abscission of SiO 2 and the distinctive structure reduces the stress and strain of SiO 2 during (de)lithiation. The positive mechano-electrochemical coupling effect preserves the amount of electrochemically active phase (Li x Si) during cycles and facilitates Li + diffusion. Therefore, the capacity shows only a slight attenuation after 8000 cycles (cycling stability), and the specific capacity is ~1200 mA h g –1 at 5 A/g (rate-performance). This study furnishes a novel way to design high-performance Li + /Na + /K + /Al 3+ anodes with large volume expansion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nuclide inventory characterization of EBR-II MOX fuel test pins

Characterization of 3 mixed oxide (MOX) fuel pins from the Experimental Breeder Reactor II (EBR-II) SPA-2/-2B experiment program was performed in support of the Advanced Reactor Experiments for Sodium Fast Reactor Fuels (ARES) joint project between Idaho National Laboratory (INL) and the Japan Atomic Energy Agency (JAEA). The characterization efforts were performed to enable transient testing in the Transient Reactor Test (TREAT) facility at INL and will include post irradiation examination (PIE) and other analyses. MOX fuel pins UW02009, 02011, and 06024 were historically irradiated from 1989 to 1994 for a total of 822.42 effective full power days (EFPDs) and peak burnup of approximately 14.3 at.% (atomic percent of heavy metal atoms, ∼134.4 GWd/t). They had since been placed in storage until a future use was identified. Characterization of the fission products and activation of each fuel pin was necessary to enable removal from storage and subsequent irradiation testing or PIE activities. The initial fuel pin geometry and composition were established using historical documentation. Irradiation history details were utilized to compute irradiated and decayed fuel pin masses, atomic densities, and activities. A pellet-wise axial neutron flux was also computed to assist in evaluation of the axial distribution of {sup 235}U and {sup 239}Pu, per pellet, within each of the test fuel pins. The results computed herein supported experiment design for advanced high-burnup MOX fuel designs under slow transient overpower (MOXTOP) conditions, which was Phase I of the ARES project. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Use of Gas Adsorption and Inversion Methods for Shale Pore Structure Characterization

The analysis of porosity and pore structure of shale rocks has received special attention in the last decades as unconventional reservoir hydrocarbons have become a larger parcel of the oil and gas market. A variety of techniques are available to provide a satisfactory description of these porous media. Some techniques are based on saturating the porous rock with a fluid to probe the pore structure. In this sense, gases have played an important role in porosity and pore structure characterization, particularly for the analysis of pore size and shapes and storage or intake capacity. In this review, we discuss the use of various gases, with emphasis on N2 and CO2, for characterization of shale pore architecture. We describe the state of the art on the related inversion methods for processing the corresponding isotherms and the procedure to obtain surface area and pore-size distribution. The state of the art is based on the collation of publications in the last 10 years. Limitations of the gas adsorption technique and the associated inversion methods as well as the most suitable scenario for its application are presented in this review. Finally, we discuss the future of gas adsorption for shale characterization, which we believe will rely on hybridization with other techniques to overcome some of the limitations.

04 OIL SHALES AND TAR SANDS↗

Oversizing and Part-Load Problems

Oversizing, the common engineering practice of specifying devices with capacity exceeding the actual load requirement, is a widespread practice across virtually all building technologies end-use categories, including HVAC, electrical systems, lighting, appliances, and plug loads. This practice, driven by factors like design uncertainty, institutional pressures, and risk aversion, results in wasted capital investment, control difficulties, and excessive energy consumption due to inefficient part-load operation. Part-load operation, where devices run below maximum capacity, is the dominant operating mode in most energy systems and presents a complex design challenge. Solutions to match output to load fall into three broad categories: constraining the output, adjusting the device’s internal behavior, and linking output to energy storage or other waste-heat reuse applications. The energy implications of part-load are critical, as efficiency often drops sharply as load decreases across a wide diversity of devices. To quantify the extent of this problem, we derive a dimensionless Part-Load Metric (PLM) based on device efficiency and its frequency distribution of operating hours at various output levels. The PLM quantifies the deviation of a device's actual efficiency from its maximum design efficiency. This metric also serves as a measure of "capital inefficiency," enabling engineers to compare the impact of different part-load solutions and providing a unified framework for evaluating performance across various devices and systems.

Meier, Alan↗

Operando Neutron Imaging of Lithium Flux and Gradient Cathode Design for Enhanced Kinetics in High‐Loading All‐Solid‐State Li─S Batteries

All-solid-state Li–sulfur batteries (ASSLSBs) are considered promising candidates for next-generation energy storage owing to their inherent safety, high energy density, and abundant sulfur resources. However, slow redox kinetics greatly limit sulfur utilization during solid-solid sulfur reactions, leading to significant challenges to achieve efficient performance in high-mass-loading ASSLSBs. Here, operando neutron image is employed to directly visualize, for the first time, that sluggish Li + transport kinetics and the uneven distribution of Li + during cathodic reactions are critical factors limiting sulfur conversion. To address this issue, gradient cathode architectures comprising three and five layers are designed, in which catholyte concentrations are strategically varied to optimize Li-ion flux and enhance ionic conductivity of the whole composite cathode electrode. Operando neutron imaging distinctly visualizes and confirms that three-layer gradient approach significantly enhances Li-ion mobility, resulting in more uniform redox reactions and greatly improved sulfur utilization compared to traditional non-gradient structures. Consequently, the three-layer gradient cathode achieves superior rate performance and reduced electrode polarization at high sulfur mass loadings of 4.5 and 6.0 mg cm −2 . Furthermore, the applicability and scalability of this design are demonstrated in a five-layer gradient cathode architecture, achieving an impressive discharge specific capacity increase from 656 mAh g −1 (three-layer gradient) to 1232 mAh g −1 at 1/20 C for ultra-high sulfur loading of 7.5 mg cm −2 . In conclusion, this innovative gradient cathode design offers substantial advancements in understanding and overcoming Li-ion transport limitations, paving the way toward practical, high-energy-density ASSLSBs.

25 ENERGY STORAGE↗

Cybersecurity Standards for Distributed Energy Resources: Gaps and Harmonization Strategy

This report examines cybersecurity standards for Distributed Energy Resources (DERs) in light of their rapid growth and increasing integration into energy systems. It identifies critical gaps in existing frameworks, including inadequate coverage of DER-specific challenges, complexities in implementing comprehensive standards, integration issues with legacy systems, adoption hurdles for newer standards, and a lack of harmonization across regulatory landscapes. The analysis highlights vulnerabilities such as data integrity risks, unauthorized device control, and denial-of-service attacks across various DER technologies like solar PV, wind turbines, energy storage systems, and hydrogen fuel cells. The report proposes a harmonization strategy to address these deficiencies by developing unified cybersecurity requirements, certification programs, and training resources while fostering collaboration among stakeholders such as government agencies, industry groups, DER operators, manufacturers, and research institutions. A phased roadmap is outlined to refine and implement these measures through pilot testing and widespread adoption. Ultimately, the report underscores the urgent need for coordinated efforts to enhance DER cybersecurity and ensure the reliable operation of future energy systems.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Probabilistic Evaluation of Geomechanical Risks in CO2 Storage: An Exploration of Caprock Integrity Metrics Using a Multilaminate Model

The probabilistic uncertainty assessment of geomechanical risk—specifically, caprock failure—attributable to CO2 injection, as presented in a simplified hypothetical geological model, was the focus of this study. Our approach amalgamates the implementation of a multilaminate model, the creation of a response surface model in conjunction with the Box–Behnken sampling design, the execution of associated numerical modeling experiments, and the utilization of Monte Carlo simulations. Probability distributions to encapsulate the inherent variability (elastic and mechanical properties of the caprock and reservoir) and uncertainty in prediction estimates (vertical displacement, total strain, and F value) were employed. Our findings reveal that the Young modulus of the caprock is a key factor controlling equivalent total strain but is insufficient as a stand-alone indicator of caprock integrity. It is confirmed that the caprock can accommodate significant deformation without failure, if it possesses a low Young’s modulus and high mechanical strength properties, such as the friction angle and uniaxial compressive strength. Similarly, vertical displacement was found to be an unreliable indicator for caprock integrity, as caprock failure can occur across a broad spectrum of vertical displacements, particularly when both the Young modulus and mechanical strength properties have wide ranges. This study introduces the F value as the most dependable indicator for caprock failure, although it is a theoretical attribute (the shortest distance between the Mohr circle and the nearest failure envelope used to measure the sensitivity to failure) and not physically measurable in the field. Deviatoric stress levels were found to vary based on stress regimes, with the maximum levels observed under extensive and compressive stress regimes. In conjunction with the use of the response surface method, this study demonstrates the efficacy of the multilaminate framework and the Mohr–Coulomb constitutive model in providing a simplified, yet effective, probabilistic model of the mechanical behavior of caprock failure, reducing mathematical and computational complexities.

Energy & Fuels↗

Guest Editorial Special Section on Advanced Medium-Voltage Power Electronics for Grid Interactive Applications

Medium-voltage power electronics (MVPE) plays essential roles in power grid modernization and links the MV distribution grid with low-voltage consumers and prosumers. Various MVPE devices, such as solid-state transformers or circuit breakers, inverter-based resources, power flow controllers, etc., bring the benefits of voltage conversion and power regulation in small footprint, power quality and efficiency improvements, and enhancements of grid controllability, flexibility, stability, and resilience. The MVPE also makes it possible for sustainable energy systems, such as solar/wind farms and energy storage generating facilities, to directly access to MV grids without multistage conversions. With their intrinsic intelligence and communications, MVPE enables many new smart grid functions and applications, e.g., dc interconnections and electric vehicle charging, which were not envisioned by traditional power grids otherwise. In addition, the integration of physical power processing units with cyber components forms a cyber-physical system, which is essential for long-term sustainability, development, and environmental preservation. Nonetheless, technical challenges on MVPE device reliability, scalable and efficient converter topologies, control stability, large-scale modeling and simulation, to name a few, need to be addressed and advanced to the next level. In conclusion, this Special Section on Advanced MV Power Electronics for Grid Interactive Applications in IEEE Transactions on Power Electronics (TPEL) provides an insight on some of the recent advances in MVPE and emerging challenges and potential solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Mo 3 S 13 Chalcogel: A High-Capacity Electrode for Conversion-Based Li-Ion Batteries

Despite large theoretical energy densities, metal-sulfide electrodes for energy storage systems face several limitations that impact the practical realization. Here, we present the solution-processable, room temperature (RT) synthesis, local structures, and application of a sulfur-rich Mo 3 S 13 chalcogel as a conversion-based electrode for lithium-sulfide batteries (LiSBs). The structure of the amorphous Mo 3 S 13 chalcogel is derived through operando Raman spectroscopy, synchrotron X-ray pair distribution function (PDF), X-ray absorption near edge structure (XANES), and extended X-ray absorption fine structure (EXAFS) analysis, along with ab initio molecular dynamics (AIMD) simulations. A key feature of the three-dimensional (3D) network is the connection of Mo 3 S 13 units through S–S bonds. Li/Mo 3 S 13 half-cells deliver initial capacity of 1013 mAh g –1 during the first discharge. After the activation cycles, the capacity stabilizes and maintains 312 mAh g –1 at a C/3 rate after 140 cycles, demonstrating sustained performance over subsequent cycling. Such high-capacity and stability are attributed to the high density of (poly)sulfide bonds and the stable Mo–S coordination in Mo 3 S 13 chalcogel. Importantly, these findings showcase the potential of Mo 3 S 13 chalcogels as metal-sulfide electrode materials for LiSBs.

25 ENERGY STORAGE↗

Distribution System Blackstart and Restoration Using DERs and Dynamically Formed Microgrids

Extreme weather events have led to long-duration outages in the distribution system (DS), necessitating novel approaches to blackstart and restore the system. Existing blackstart solutions utilize blackstart units to establish multiple microgrids (MGs), sequentially energize non-blackstart units, and restore loads. However, these approaches often result in isolated MGs. In DERs-aided blackstart, the continuous operation of these MGs is limited by the finite energy capacity of commonly used blackstart units like battery energy storage (BES)-based gridforming inverters (GFMIs). To address this issue, this article proposes a holistic blackstart and restoration framework that incorporates synchronization between dynamic MGs and the entire DS with the transmission grid (TG). To support synchronization, we leveraged virtual synchronous generator-based control for GFMIs to estimate their frequency response to load pick-up events using only initial/final quasi-steady-state points. Subsequently, a synchronization switching condition is developed to model synchronizing switches, aligning them seamlessly with a linearized branch flow problem. Finally, we designed a bottomup blackstart and restoration framework that considers the switching structure of the DS, energizing/synchronizing switches, DERs with grid-following inverters, and BES-based GFMIs with frequency security constraints. In conclusion, the proposed framework is validated in IEEE-123-bus system, considering cases with two and four GFMIs under various TG recovery instants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stabilizing high-Ni cathodes with gradient surface Ti-enrichment

High-Ni cathodes are being intensely pursued worldwide for electric vehicles and other energy-dense applications due to their high capacity and low cost. However, structural instabilities during electrochemical cycling and when subjected to thermal treatment have been the major issues hindering their practical deployment. We here report a rational design of coating-integrated-into-synthesis protocol for fabricating surface Ti-enriched LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811#Ti) material. The coating to intermediates is crucial to obtain high structural ordering, both in the bulk and surface of high-Ni cathodes, and the Ti substitute has a unique tri-valence (Ti 3+ ) in a gradient surface distribution. Further, the simulations of projected density of states in the atomistic understanding further certify significantly enhanced stability of lattice oxygen for the NMC811 through such a Ti 3+ -based structure reinforcement. Consequently, the NMC811#Ti cathode delivers a high capacity up to 200mAhg -1 at 0.1 C, along with superior stabilities during air-storage and thermal treatment (up to 297°C at the fully charged state under differential scanning calorimetric measurements). The corresponding NMC811#Ti||graphite full cell exhibits a desired 83.6% capacity retention after 1000 cycles at 0.5 C in a voltage range of 2.8–4.3V. This work demonstrates a delicate surface reinforcement to stabilize high-Ni cathodes for long-life and safe lithium-ion batteries.

36 MATERIALS SCIENCE↗

Solving Critical Problems of the Muon Collider Higgs Factory: Optics, Magnets and their Protection, Detector Backgrounds

A low-energy medium-luminosity Muon Collider (MC) is being studied as a possible Higgs Factory (HF). Electrons from muon decays will deposit more than 300 kW in superconducting magnets of the HF collider ring. This imposes significant challenges to superconducting (SC) magnets used in the MC storage ring (SR) and interaction regions (IR). Magnet designs are proposed which provide high operating gradient and magnetic field in a large aperture to accommodate the large size of muon beams (due to low beta*), as well as a cooling system to intercept the large heat deposition from the showers induced by decay electrons. The distribution of heat deposition in the MC SR lattice elements requires large-aperture magnets in order to accommodate thick high-Z absorbers to protect the SC coils. Based on the developed MARS15 model and intensive simulations, a sophisticated radiation protection system was designed for the collider SR and IR to bring the peak power density in the superconducting coils below the quench limit and reduce the dynamic heat deposition in the cold mass by a factor of 100. The system consists of tight tungsten masks in the magnet interconnect regions and elliptical tungsten liners in the magnet aperture optimized individually for each magnet. These also reduce the background particle fluxes in the collider detector.

43 PARTICLE ACCELERATORS↗

Advanced Computational Modeling of High-Level Waste Vitrification at the Hanford Site

The U.S. Department of Energy (DOE) has selected vitrification for stabilizing legacy tank waste at the Hanford site, where radioactive waste from plutonium production was historically stored in underground tanks. This waste will be separated into low-activity waste (LAW) and high-level waste (HLW) fractions and processed at the Waste Treatment and Immobilization Plant (WTP). At WTP, glass melters are used for the vitrification of radioactive tank waste, transforming it into a stable borosilicate glass form for safe long-term storage. The melter vessel is constructed from highly durable and heat-resistant materials, where the vitrification process occurs. The main regions that are modeled are the melt pool, plenum, cold cap, riser/discharge chamber, and surrounding structure with insulation layers. Forced convection induced by air bubblers at the base of the melter ensure uniform temperature distribution and provide heat to the cold cap layer. The cold cap is a region of reacting batch feed that floats on top of the molten glass and is where the batch-to-glass reactions occur. Joule heating provided by electrodes mounted along the vertical walls of the melter and immersed directly in the glass, generates the necessary heat for the net endothermic conversion processes that occur in the cold cap. The high temperatures, radioactivity, and opaque nature of the glass prevent direct observation inside the melters. Therefore, computational models are essential for providing insight into factors that affect melter throughput. Thermocouples in the plenum provide operators with plenum temperature measurements. Operational adjustments include bubbling rate, voltage supplied to the electrodes, feed adjustments, and glass removal rate. Different computational fluid dynamics (CFD) models have been developed, each serving a specific purpose. There are CFD models of different scale melters, as well as models that capture the two-phase flow interfaces of rising bubbles in the molten glass or models with a simplified molten glass region so that the surrounding structure and plenum can be feasibly incorporated. Pilot-scale melter models have been developed to serve as validation of the methods employed in the simulation of the full-scale WTP melters. Models incorporating resolved bubbling are used to develop momentum source terms to implement into a single phase, multi-region, steady-state flow model that is being validated by measured process parameters such as glass production rate, voltage, input power, plenum temperatures, etc. The resolved bubbling model uses the multiphase volume of fluid approach to model the system with a high-resolution interface capturing scheme to maintain sharp interfaces between the molten glass and the air phase. The suite of CFD models is continually being improved to incorporate more realistic physics and achieve faster turnaround time. For example, an incremental controller is implemented to automatically adjust electrode voltage within the simulation to a molten glass set point temperature of 1150°C. Newer models feature improved meshes to ensure conformal meshes between regions and eliminate unnecessary mesh refinement in areas that are not of interest (such as boundary layers in offgas ports). Instead of explicitly modeling the structural, refractory, and insulation layers of the melter, a thermal resistance approach is used with published correlations used for boundary conditions. The development of robust and efficient CFD models will be instrumental in enabling the WTP to successfully fulfill its mission of safely stabilizing legacy nuclear waste.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Multidimensional visualization of the dynamic evolution of Li metal via in situ/operando methods

The growing demands for high-energy density electrical energy storage devices stimulate the coupling of conversion-type cathodes and lithium (Li) metal anodes. While promising, the use of these “Li-free” cathodes brings new challenges to the Li anode interface, as Li needs to be dissolved first during cell operation. In this study, we have achieved a direct visualization and comprehensive analysis of the dynamic evolution of the Li interface. The critical metrics of the interfacial resistance, Li growth, and solid electrolyte interface (SEI) distribution during the initial dissolution/deposition processes were systematically investigated by employing multidimensional analysis methods. They include three-electrode impedance tests, in situ atomic force microscopy, scanning electrochemical microscopy, and cryogenic scanning transmission electron microscopy. The high-resolution imaging and real-time observations show that a loose, diffuse, and unevenly distributed SEI is formed during the initial dissolution process. This leads to the dramatically fast growth of Li during the subsequent deposition, deviating from Fick’s law, which exacerbates the interfacial impedance. The compactness of the interfacial structure and enrichment of electrolyte species at the surface during the initial deposition play critical roles in the long-term stability of Li anodes, as revealed by operando confocal Raman spectroscopic mapping. In conclusion, our observations relate to ion transfer, morphological and structural evolution, and Li (de)solvation at Li interfaces, revealing the underlying pathways influenced by the initial dissolution process, which promotes a reconsideration of anode investigations and effective protection strategies.

25 ENERGY STORAGE↗

Spatial-Temporal PV Hosting Capacity Estimation and Evaluation

Evaluating Photovoltaic Hosting Capacity (PVHC) is an essential step in the process of integrating solar energy into power grids, particularly when focusing on the distribution network (DN) as the primary integration target. PVHC needs to be investigated, especially in cases where the grids are unbalanced, and their operational conditions vary spatially and temporally. This motivation prompted us to propose a scalable model tailored to this application. In this paper, we applied linearization to the alternating current optimal power flow (AC-OPF) and solar inverters, transforming the original problem into a mixed-integer linear programming (MILP) problem. Additionally, we accounted for the battery energy storage system (BESS) as a time-coupling factor for calculating PVHC. We then compared the PVHC results between the IEEE-13 bus and SMART-DS San Francisco (SFO) cases and discussed the extent to which BESS can enhance the PVHC of a DN. Furthermore, we designed a web-based graphical visualization for the SFO case, enabling user interaction with raw data and simulation results on a map through a graphical user interface (GUI). In summary, our results and findings provide valuable insights for future three-phase unbalanced AC-OPF PVHC practices and their visualization.

AC-optimal power flow↗

Adaptive cold-load pickup considerations in 2-stage microgrid unit commitment for enhancing microgrid resilience

In an extended main grid outage spanning multiple days, load shedding serves as a critical mechanism for islanded microgrids to maintain essential power and energy reserves that are indispensable for fulfilling reliability and resiliency mandates. However, using load shedding for such purposes leads to increasing occurrence of cold load pickup (CLPU) events. Here, this study presents an innovative adaptive CLPU model that introduces a method for determining and incorporating parameters related to CLPU power and energy requirements into a two-stage microgrid unit commitment (MGUC) algorithm. In contrast to the traditional fixed-CLPU-curve approach, this model calculates CLPU duration, power, and energy demands by considering outage durations and ambient temperature variations within the MGUC process. By integrating the adaptive CLPU model into the MGUC problem formulation, it allows for the optimal allocation of energy resources throughout the entire scheduling horizon to fulfill the CLPU requirements when scheduling multiple CLPU events. The performance of the enhanced MGUC algorithm considering CLPU needs is assessed using actual load and photovoltaic (PV) data. Simulation results demonstrate significant improvements in dispatch optimality evaluated by the amount of load served, customer comfort, energy storage operation, and adherence to energy schedules. These enhancements collectively contribute to reliable and resilient microgrid operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗