At least 1,495 records · Page 83

Development of Miniaturized Optimized Smart Sensors (MOSS) for space plasmas

The cost of space plasma sensors is high for several reasons: (1) Most are one-of-a-kind and state-of-the-art, (2) the cost of launch to orbit is high, (3) ruggedness and reliability requirements lead to costly development and test programs, and (4) overhead is added by overly elaborate or generalized spacecraft interface requirements. Possible approaches to reducing costs include development of small 'sensors' (defined as including all necessary optics, detectors, and related electronics) that will ultimately lead to cheaper missions by reducing (2), improving (3), and, through work with spacecraft designers, reducing (4). Despite this logical approach, there is no guarantee that smaller sensors are necessarily either better or cheaper. We have previously advocated applying analytical 'quality factors' to plasma sensors (and spacecraft) and have begun to develop miniaturized particle optical systems by applying quantitative optimization criteria. We are currently designing a Miniaturized Optimized Smart Sensor (MOSS) in which miniaturized electronics (e.g., employing new power supply topology and extensive us of gate arrays and hybrid circuits) are fully integrated with newly developed particle optics to give significant savings in volume and mass. The goal of the SwRI MOSS program is development of a fully self-contained and functional plasma sensor weighing 1 lb and requiring 1 W. MOSS will require only a typical spacecraft DC power source (e.g., 30 V) and command/data interfaces in order to be fully functional, and will provide measurement capabilities comparable in most ways to current sensors.

Young, D. T.↗

R&D Towards CUPID, a Tonne-Scale Bolometric 0νββ Experiment (Collaborative Proposal)

As endorsed by the 2015 Long Range Plan for Nuclear Science, development of the ton-scale 0νββ experiment with the sensitivity to the effective neutrino mass at the level of 15 meV is one of the highest priorities for the nuclear physics. Bolometric detector based on CUORE design is very well matched to this goal. We have assembled a Collaboration to develop CUPID, a next-generation bolometric 0νββ detector based on CUORE experience and design, but improving upon CUORE sensitivity by more than an order of magnitude.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proceedings of the Third Infrared Detector Technology Workshop

This volume consists of 37 papers which summarize results presented at the Third Infrared Detector Technology Workshop, held February 7-9, 1989, at Ames Research Center. The workshop focused on infrared (IR) detector, detector array, and cryogenic electronic technologies relevant to low-background space astronomy. Papers on discrete IR detectors, cryogenic readouts, extrinsic and intrinsic IR arrays, and recent results from ground-based observations with integrated arrays were given. Recent developments in the second-generation Hubble Space Telescope (HST) infrared spectrometer and in detectors and arrays for the European Space Agency's Infrared Space Observatory (ISO) are also included, as are status reports on the Space Infrared Telescope Facility (SIRTF) and the Stratospheric Observatory for Infrared Astronomy (SOFIA) projects.

Mccreight, Craig R.↗

Development of X-Ray Microcalorimeter Imaging Spectrometers for the X-Ray Surveyor Mission Concept

Four astrophysics missions are currently being studied by NASA as candidate large missions to be chosen inthe 2020 astrophysics decadal survey.1 One of these missions is the X-Ray Surveyor (XRS), and possibleconfigurations of this mission are currently under study by a science and technology definition team (STDT). Oneof the key instruments under study is an X-ray microcalorimeter, and the requirements for such an instrument arecurrently under discussion. In this paper we review some different detector options that exist for this instrument,and discuss what array formats might be possible. We have developed one design option that utilizes eithertransition-edge sensor (TES) or magnetically coupled calorimeters (MCC) in pixel array-sizes approaching 100kilo-pixels. To reduce the number of sensors read out to a plausible scale, we have assumed detector geometriesin which a thermal sensor such a TES or MCC can read out a sub-array of 20-25 individual 1 pixels. In thispaper we describe the development status of these detectors, and also discuss the different options that exist forreading out the very large number of pixels.

multiplexing↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Super-resolution model for overlapping peak detection and improved spatial resolution in high-energy diffraction microscopy

Reconstruction quality in Far-field High-Energy Diffraction Microscopy (FF-HEDM) is limited by the spatial resolution of area detectors and the frequent occurrence of overlapping diffraction spots. To address these challenges, we developed a super-resolution (SR) framework using convolutional neural networks (CNNs) to recreate 2D diffraction peaks at up to ×8 resolution from raw detector data. A specialized simulation tool was created to generate synthetic training datasets with varying degrees of peak overlap. Integrated into the Microstructural Imaging using Diffraction Analysis Software (MIDAS), the SR model improves the spatial accuracy and precision of 3D grain reconstruction by an order of magnitude. This approach provides a robust solution for investigation of complex micromechanical states and material classes where the analysis is limited by the presence of overlapping peaks. Furthermore, the methodology developed here can potentially be extended to other techniques that require sub-pixel accuracy for high-fidelity data analysis.

High-energy diffraction microscopy↗

Characterization of Pinhole Collimators for High-Resolution Gamma Imaging of Irradiated Fuel

Post-irradiation examination (PIE) of nuclear fuels requires imaging tools capable of resolving isotopic and spatial features with high throughput. This project contributes to a proof-of-concept effort aimed at advancing gamma emission tomography (GET) by evaluating novel fine-aperture pinhole collimators. Two Rose’s metal collimators, 100 µm (20° acceptance angle) and 350 µm (30° acceptance angle), were prototyped and characterized for their effectiveness in transporting gamma rays through the pinhole aperture. To support data collection, a Python-based data acquisition system was developed to coordinate a rotation stage, linear stage, and CZT detector, reducing latency in high-rate gamma event logging to one second per acquisition. Queue-based file writing enabled seamless real-time data capture for count rates up to 35,000 counts per second (cps). List-mode parsing algorithms were implemented to differentiate single and simultaneous gamma interactions for future tomographic reconstruction. Detector response was evaluated in both spectroscopy and list mode acquisition methods across varying source distances to confirm absolute and collimator efficiencies. Preliminary efficiency figures suggest effective collimation of gamma-rays with energies below 700 keV, with ~4% residual intensity through the aperture for Cs-137. The impact of collimator geometry on image quality is currently being evaluated. This groundwork supports the ongoing development of a sub mm resolution cone-beam CT system for imaging fuel phantoms, an essential step toward improving GET efficiency and accelerating nuclear fuel qualification efforts.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

CZT Imaging Arrays for Space Applications

The compound CZT offers great promise for space applications with applications in such areas as radiation monitoring, planetary investigations and astrophysics. As crystal quality improves, the challenge for imaging array development is to derive electrode geometries and readout electronics to satisfy particular applications and to understand how the material will perform in the space environment. An overview of present and future detector requirements will be given together with the status of current array developments.

Ramsey, Brian D.↗

Silicon Detector Studies with an Interferometric Thickness Mapper

Cosmic ray isotopic composition studies aboard satellites are normally based on energy detection measurements which require a precise knowledge of matter thickness particle penetration. A laser- interferometer system has been developed to precisely map the thick- ness variations of large-area silicon detectors. Design, operation, and the data processing to derive thickness maps is described.

Cosmic Rays Silicon Detectors Interferometry Satel↗

Heat Transfer Issues in Thin-Film Thermal Radiation Detectors

The Thermal Radiation Group at Virginia Polytechnic Institute and State University has been working closely with scientists and engineers at NASA's Langley Research Center to develop accurate analytical and numerical models suitable for designing next generation thin-film thermal radiation detectors for earth radiation budget measurement applications. The current study provides an analytical model of the notional thermal radiation detector that takes into account thermal transport phenomena, such as the contact resistance between the layers of the detector, and is suitable for use in parameter estimation. It was found that the responsivity of the detector can increase significantly due to the presence of contact resistance between the layers of the detector. Also presented is the effect of doping the thermal impedance layer of the detector with conducting particles in order to electrically link the two junctions of the detector. It was found that the responsivity and the time response of the doped detector decrease significantly in this case. The corresponding decrease of the electrical resistance of the doped thermal impedance layer is not sufficient to significantly improve the electrical performance of the detector. Finally, the "roughness effect" is shown to be unable to explain the decrease in the thermal conductivity often reported for thin-film layers.

Barry, Mamadou Y.↗

Real-time nuclear activation detectors for measuring neutron angular distributions at the National Ignition Facility (invited)

The Real Time Nuclear Activation Detector (RTNAD) array at NIF measures the distribution of 14 MeV neutrons emitted by deuterium-tritium (DT) fueled inertial confinement fusion implosions. The uniformity of the neutron distribution is an important indication of implosion symmetry and DT shell integrity. The array consists of 48 LaBr 3 (Ce) crystal gamma-ray spectrometers mounted outside the NIF target chamber, which continuously monitor the slow decay of the 909 keV gamma-ray line from activated 89 Zr located in Zr cups surrounding each crystal. The measured decay rate dramatically increases during a DT implosion in proportion to the number of 14 MeV neutrons striking each Zr cup. The neutrons produce activated 89 Zr through an (n, 2n) reaction on 90 Zr, which is insensitive to low energy neutrons. The neutron flux along the detector line-of-sight at shot time is determined by extrapolating the fitted 909 keV decay curve back to shot time. Automatic analysis algorithms were developed to handle the non-stop data stream. The large number of detectors and the high statistical accuracy of the array enable the spherical harmonic modes of the neutron angular distribution to be measured up to L ≤ 4 to provide a better understanding of implosion dynamics. In addition, these data combined with measurements of the down-scattered neutrons can be used to derive fuel areal density distributions. This paper will describe the RTNAD hardware and analysis procedures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Whispering Gallery Mode Resonator with Orthogonally Reconfigurable Filter Function

An optical resonator has been developed with reconfigurable filter function that has resonant lines that can be shifted precisely and independently from each other, creating any desirable combination of resonant lines. This is achieved by changing the axial distribution of the effective refractive index of the resonator, which shifts the resonant frequency of particular optical modes, leaving all the rest unchanged. A reconfigurable optical filter is part of the remote chemical detector proposed for the Mars mission (Planetary Instrument Definition and Development Program PIDDP), but it is also useful for photonic communications devices.

Maleki, Lute↗

Multispectral Linear Array detector technology

The Multispectral Linear Array (MLA) program sponsored by NASA has the aim to extend space-based remote sensor capabilities. The technology development effort involves the realization of very large, all-solid-state, pushbroom focal planes. The pushbroom, staring focal planes will contain thousands of detectors with the objective to provide two orders of magnitude improvement in detector dwell time compared to present Landsat mechanically scanned systems. Attenton is given to visible and near-infrared sensor development, the shortwave infrared sensor, aspects of filter technology development, the packaging concept, and questions of system performance. First-sample, four-band interference filters have been fabricated successfully, and a hybrid packaging technology is being developed.

Tower, J. R.↗

Data for training and testing radiation detection algorithms in an urban environment

The detection, identification, and localization of illicit nuclear materials in urban environments is of utmost importance for national security. Most often, the process of performing these operations consists of a team of trained individuals equipped with radiation detection devices that have built-in algorithms to alert the user to the presence nuclear material and, if possible, to identify the type of nuclear material present. To encourage the development of new detection, radioisotope identification, and source localization algorithms, a dataset consisting of realistic Monte Carlo-simulated radiation detection data from a 2 in. × 4 in. × 16 in. NaI(Tl) scintillation detector moving through a simulated urban environment based on Knoxville, Tennessee, was developed and made public in the form of a Topcoder competition. The methodology used to create this dataset has been verified using experimental data collected at the Fort Indiantown Gap National Guard facility. Realistic signals from special nuclear material and industrial and medical sources are included in the data for developing and testing algorithms in a dynamic real-world background.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Cryogenic Technology: Ongoing Developments for the Next Decade

To obtain optimum sensitivity a submillimeter space observatory will require low temperature mirrors (approx. 3K) and very low temperature detectors (< or approx. 0.1 K). Both of these temperatures have been achieved by space cryogenic systems, but neither for a 10 year duration. Past systems used superfluid helium to provide direct cooling in the 1 to 2 K range (IRAS, COBE, IRTS, ISO) or as an upper stage for an adiabatic demagnetization refrigerator to achieve temperatures down to 0.06 K (Astro-E/XRS). Boiloff vapor may be used to cool an otherwise warm telescope as in the Space InfraRed Telescope Facility (SIRTF). In SIRTF a 0.85 m telescope is cooled to 5.5 K by absorbing about 6 mW in the cold vapor. This residual heat is due to both radiation from a helium vapor cooled outer shield at about 20 K and from conduction through a structure mounting the cold telescope and instruments to the warm spacecraft. The boil off rate required to cool the telescope results in a 2.6 to 5 year lifetime, depending on whether other parasitic heat sources such as thermoacoustic oscillations are also present. A helium dewar results in a very heavy system to achieve 2 to 5 year lifetimes. For example it takes roughly 400 kg for XRS to achieve 0.06 K for two year life with a 250 K boundary temperature, and approx. 300 kg (including thermal shielding) for SIRTF to achieve 1.3 K for 5 year life with a 35 K boundary temperature. To go to longer duration and to lower the weight, active cooling methods are required combined with more aggressive passive cooling techniques. It is possible, with some development, to provide cooling for detectors to 0.05 K and telescopes and instruments to < 4 K for a 10 year mission with a 100 kg system including power sources, structural support, and vacuum enclosures for critical portions of the instruments.

DiPirro, Michael↗

In-pixel integration of signal processing and AI/ML based data filtering for particle tracking detectors

We present the first physical realization of in-pixel signal processing with integrated AI-based data filtering for particle tracking detectors. Building on prior work that demonstrated a physics-motivated edge-AI algorithm suitable for ASIC implementation, this work marks a significant milestone toward intelligent silicon trackers. Our prototype readout chip performs real-time data reduction at the sensor level while meeting stringent requirements on power, area, and latency. The chip is taped-out in 28nm TSMC CMOS bulk process, which has been shown to have sufficient radiation hardness for particle experiments. This development represents a key step toward enabling fully on-detector edge AI, with broad implications for data throughput and discovery potential in high-rate, high-radiation environments such as the High-Luminosity LHC.

Parpillon, Benjamin [Fermilab; Illinois U., Chicag↗

Fermilab's controls development with virtual accelerator

Control Systems development is often the last thing considered when designing and building new equipment, e.g. a new detector or superconducting RF LINAC; however when the new equipment is installed, it is the first thing desired to be operational for testing. Due to frequent delays in building new equipment and project deadlines, control system development and testing is often curtailed. A way to alleviate this problem is to simulate the control system, though this will be challenging for complex systems.The Fermilab PIP-II (proton improvement plan - II) project is being constructed at Fermilab to deliver $800\,MeV$ protons of $>1\,MW$ beam power to replace the present LINAC for the remainder of the existing accelerator complex. The new LINAC consists of a warm front end (WFE), 23 superconducting RF cryomodules (of 5 types), and a beam transfer line (BTL) to the existing complex.The accelerator physics group has a parallel project to create a digital twin (DT) of the PIP-II accelerator. We have coupled the EPICS controls to this DT and are developing both the DT and EPICS software in parallel. This will allow us to develop the EPICS software framework, the HMIs, sequences, high level physics applications, and other services for use in a fully functional control system.This presentation will detail the work that we have performed to date and show demonstrations of controlling and monitoring the status of the accelerator, as well as future plans for this work.

Hanlet, Pierrick [Fermilab]↗

A perspective on the device physics of lead halide perovskite semiconducting detector for gamma and x-ray sensing

Metal-halide perovskites are emerging materials for radiation sensing featuring high absorption cross section, high charge mobility, and long carrier lifetime enabling superior detection efficiencies even at room temperature. Perovskite detector technologies are more complex involving different detecting modes and device architectures. Here, to elucidate the working principles, we provide a Perspective on the device structures and the operational principles of halide perovskite direct conversion detectors for radiation sensing. We will first discuss different detection modes and introduce the commonly used device architectures and their working principles. Based on our work and pioneer developments in the field, we will next compare the performances of the reported detectors. Additionally, we will summarize the single crystal detectors and polycrystalline thin film devices and discuss their advantages and disadvantages for different applications. Finally, we provide a future Perspective on the critical problems that must be addressed to commercialize this technology.

77 NANOSCIENCE AND NANOTECHNOLOGY↗