Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “count data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

GALACTIC STRUCTURE BASED ON THE ATLASGAL 870 {mu}m SURVEY

The ATLASGAL 870 {mu}m continuum survey conducted with the APEX telescope is the first one covering the whole inner Galactic plane (60 Degree-Sign > l > -60 Degree-Sign and b < {+-}1.{sup 0}5) in submillimeter (submm) continuum emission tracing the cold dust of dense and young star-forming regions. Here, we present the overall distribution of sources within our Galactic disk. The submm continuum emission is confined to a narrow range around the Galactic plane, but shifted on average by {approx}0.07 deg below the plane. Source number counts show strong enhancements toward the Galactic center, the spiral arms, and toward prominent star-forming regions. Comparing the distribution of ATLASGAL dust continuum emission to that of young intermediate- to high-mass young stellar objects (YSOs) derived from Spitzer data, we find similarities as well as differences. In particular, the distribution of submm dust continuum emission is significantly more confined to the plane than the YSO distribution (FWHM of 0.7 and 1.1 deg, corresponding to mean physical scale heights of approximately 46 and 80 pc, respectively). While this difference may partly be caused by the large extinction from the dense submm cores, gradual dispersal of stellar distributions after their birth could also contribute to this effect. Compared to other tracers of Galactic structure, the ATLASGAL data are strongly confined to a narrow latitude strip around the Galactic plane.

79 ASTRONOMY AND ASTROPHYSICS↗

THE MID-INFRARED ENVIRONMENTS OF HIGH-REDSHIFT RADIO GALAXIES

Taking advantage of the impressive sensitivity of Spitzer to detect massive galaxies at high redshift, we study the mid-infrared environments of powerful, high-redshift radio galaxies at 1.2 < z < 3. Galaxy cluster member candidates were isolated using a single Spitzer/IRAC mid-infrared color criterion, [3.6]-[4.5] > -0.1 (AB), in the fields of 48 radio galaxies at 1.2 < z < 3. Using a counts-in-cell analysis, we identify a field as overdense when 15 or more red IRAC sources are found within 1' (i.e., 0.5 Mpc at 1.2 < z < 3) of the radio galaxy to the 5{sigma} flux density limits of our IRAC data (f{sub 4.5} = 13.4 {mu}Jy). We find that radio galaxies lie preferentially in medium to dense regions, with 73% of the targeted fields denser than average. Our (shallow) 120 s data permit the rediscovery of previously known clusters and protoclusters associated with radio galaxies as well as the discovery of new promising galaxy cluster candidates at z > 1.2.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray emission in non-AGN galaxies at z ≃ 1

Using data from the DEEP2 galaxy redshift survey and the All Wavelength Extended Groth Strip International Survey we obtain stacked X-ray maps of galaxies at 0.7⩽z⩽1.0 as a function of stellar mass. We compute the total X-ray counts of these galaxies and show that in the soft band (0.5–2 kev) there exists a significant correlation between galaxy X-ray counts and stellar mass at these redshifts. The best-fit relation between X-ray counts and stellar mass can be characterized by a power law with a slope of 0.58 ± 0.1. We do not find any correlation between stellar mass and X-ray luminosities in the hard (2–7 kev) and ultra-hard (4–7 kev) bands. The derived hardness ratios of our galaxies suggest that the X-ray emission is degenerate between two spectral models, namely point-like power-law emission and extended plasma emission in the interstellar medium. This is similar to what has been observed in low redshift galaxies. Using a simple spectral model where half of the emission comes from power-law sources and the other half from the extended hot halo we derive the X-ray luminosities of our galaxies. The soft X-ray luminosities of our galaxies lie in the range 10{sup 39}–8×10{sup 40} erg s{sup −1}. Dividing our galaxy sample by the criteria U−B>1, we find no evidence that our results for X-ray scaling relations depend on optical color.

79 ASTRONOMY AND ASTROPHYSICS↗

A massively parallel and scalable multi-CPU material point method

Harnessing the power of modern multi-GPU architectures, we present a massively parallel simulation system based on the Material Point Method (MPM) for simulating physical behaviors of materials undergoing complex topological changes, self-collision, and large deformations. Our system makes three critical contributions. First, we introduce a new particle data structure that promotes coalesced memory access patterns on the GPU and eliminates the need for complex atomic operations on the memory hierarchy when writing particle data to the grid. Second, we propose a kernel fusion approach using a new Grid-to-Particles-to-Grid (G2P2G) scheme, which efficiently reduces GPU kernel launches, improves latency, and significantly reduces the amount of global memory needed to store particle data. Finally, we introduce optimized algorithmic designs that allow for efficient sparse grids in a shared memory context, enabling us to best utilize modern multi-GPU computational platforms for hybrid Lagrangian-Eulerian computational patterns. We demonstrate the effectiveness of our method with extensive benchmarks, evaluations, and dynamic simulations with elastoplasticity, granular media, and fluid dynamics. In comparisons against an open-source and heavily optimized CPU-based MPM codebase [Fang et al. 2019] on an elastic sphere colliding scene with particle counts ranging from 5 to 40 million, our GPU MPM achieves over 100x per-time-step speedup on a workstation with an Intel 8086K CPU and a single Quadro P6000 GPU, exposing exciting possibilities for future MPM simulations in computer graphics and computational science. Moreover, compared to the state-of-the-art GPU MPM method [Hu et al. 2019a], we not only achieve 2x acceleration on a single GPU but our kernel fusion strategy and Array-of-Structs-of-Array (AoSoA) data structure design also generalizes to multi-GPU systems. Our multi-GPU MPM exhibits near-perfect weak and strong scaling with 4 GPUs, enabling performant and large-scale simulations on a 10243 grid with close to 100 million particles with less than 4 minutes per frame on a single 4-GPU workstation and 134 million particles with less than 1 minute per frame on an 8-GPU workstation.

Wang, Xinlei↗

(U) Feynman-Y calculations using PARTISN

A prescription for computing the Feynman Y as a function of coincidence gate width using a deterministic multigroup neutron transport code has been published and the results compared favorably with measurements of the BeRP ball. In this paper, we report on our project to implement the method and reproduce the results. There are several clarifications and corrections of the published prescription. We show results using two multigroup cross section libraries compared with measurements and with Monte Carlo results. Deterministic simulations of the mean count rates compare very favorably with previously published Monte Carlo results, and deterministic simulations of the Feynman Y asymptote compare somewhat favorably. In Feynman beta plots, the deterministic simulations reached the asymptotic value much sooner than did a fit to the measured data.

42 ENGINEERING↗

Pacific Northwest National Laboratory Regional Populations – 2020 Census: Richland Campus and Sequim Campus

The U.S. Department of Energy conducts radiological operations in south-central (Richland) and northwestern (Sequim) Washington State. Collective dose estimates to regional populations must be performed to provide a measure of the impact from site radiological releases. Results of the U.S. 2020 Census and, for the Sequim location only, the Canada 2021 Census, were used to determine counts and distributions for the residential population located within 50 miles (80 kilometers) of the Pacific Northwest National Laboratory Richland Campus and the Sequim Campus. Since the 2010 Census, total regional populations increased 25–40 percent. This revision updates and expands the data presented in the prior report by the addition of PNNL-Richland Campus population distribution information.

2020 census↗

233 U oxide Measurement Campaign Data: Passive and Active Neutron Multiplicity Measurements of Uranium Oxide Samples at Oak Ridge National Laboratory

During FY2023, three measurement campaigns were conducted at Oak Ridge National Laboratory. The goal was to quantify the neutron signatures of samples of uranium oxide containing uranium 233 and uranium-235. This report presents the neutron multiplicity data obtained using the large volume active well coincidence counter (LV-AWCC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development FD-SOI MOSFET Amplifiers for Integrated Read-Out Circuit of Superconducting-Tunnel-Junction Single-Photon-Detectors

We proposed a new high-resolution single-photon infrared spectrometer for search for radiative decay of cosmic neutrino background (CνB). The superconducting-tunnel-junctions(STJs) are used as a single-photon counting device. Each STJ consists of Nb/Al/Al x O y /Al/Nb layers, and their thicknesses are optimized for the operation temperature at 370 mK cooled by a 3 He sorption refrigerator. Our STJs achieved the leak current 250 pA, and the measured data implies that a smaller area STJ fulfills our requirement. FD-SOI MOSFETs are employed to amplify the STJ signal current in order to increase signal-to-noise ratio (S/N). FD-SOI MOSFETs can be operated at cryogenic temperature of 370 mK, which reduces the noise of the signal amplification system. FD-SOI MOSFET characteristics are measured at cryogenic temperature. The Id-Vgs curve shows a sharper turn on with a higher threshold voltage and the Id-Vds curve shows a nonlinear shape in linear region at cryogenic temperature. Taking into account these effects, FD-SOI MOSFETs are available for read-out circuit of STJ detectors. The bias voltage for STJ detectors is 0.4 mV, and it must be well stabilized to deliver high performance. We proposed an FD-SOI MOSFET-based charge integrated amplifier design as a read-out circuit of STJ detectors. The requirements for an operational amplifier used in the amplifier is estimated using SPICE simulation. The op-amp is required to have a fast response (GBW ≥ 100 MHz), and it must have low power dissipation as compared to the cooling power of refrigerator.

47 OTHER INSTRUMENTATION↗

A New Neutron Multiplicity Deadtime Scheme

Deadtime corrections for passive neutron coincidence counting are traditionally formulated in terms of the Totals counting rate. The deadtime correction is exponential in form with the effective deadtime being linear in terms of observed Totals rate. The deadtime coefficient for the Reals rate is traditionally fixed at four times that of the Totals rate parameter. When it comes to multiplicity counting, however, more complex expressions are typically used for the Doubles and Triples rates based on mathematical actions to the multiplicity histograms with the Singles (or Trigger) rate being treated rather simplistically. Since the Totals and Singles and Reals and Doubles, respectively, are effectively equivalent measures, the difference in deadtime treatment results is an inconsistency. Furthermore, additional empirical correction factors are often applied in the case of the multiplicity deadtime corrections and these do not follow from the underlying theoretical framework. The purpose of this paper is to re-examine the semi-empirical deadtime correction expressions from a fresh perspective. We propose to a scheme whereby Totals and Singles are treated equivalently with the correction having the transcendental form of the paralysable model. The impact of correlations on the Totals deadtime correction is shown to be modest. The deadtime correction factor for Reals and Doubles are again treated similarly also using an exponential form in terms of the corrected Total event rate but with a deadtime parameter which is not fixed ahead of time to be four times that used in the Totals correction. In the case of the Triples correction, which is evaluated from a composite expression, the deadtime corrections for the Singles and Doubles are used as appropriate but a new empirical correction, again given in terms of the corrected rate, is introduced. The new correction acts only on the part of the Triples expression which is does not represent the correlated-accidentals. The new scheme is not based on an elaborate mathematical model for deadtime losses and consequently does not involve a deadtime-function-weighted sum of histogram elements. In that sense it is simpler to understand and implement. Determination of the free deadtime parameters is based on first extracting the deadtime parameter for the Singles for which several options are available. The Doubles deadtime parameter is then based on rendering the corrected Doubles to Singles ratio for Cf-252 invariant to trigger rate. Similarly the Triple deadtime parameter is extracted from Cf-252 data given the Singles (or Trigger) and Doubles parameters. In this article we briefly review current practice, lay out the new concept and illustrate their application with experimental data of a passive neutron multiplicity counter. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis, crystal structure and properties of Mg{sub 3}B{sub 36}Si{sub 9}C and related rare earth compounds RE{sub 3−x}B{sub 36}Si{sub 9}C (RE=Y, Gd–Lu)

We report on the synthesis and characterisation of Mg{sub 3}B{sub 36}Si{sub 9}C. Black single crystals of hexagonal shape were yielded from the elements at 1600 °C in h-BN crucibles welded in Ta ampoules. The crystal structure (space group R3{sup ¯}m, a=10.0793(13) Å, c=16.372(3) Å, 660 refl., 51 param., R{sub 1}(F)=0.019; wR{sub 2}(F{sup 2})=0.051) is characterized by a Kagome-net of B{sub 12} icosahedra, ethane like Si{sub 8}-units and disordered SiC-dumbbells. Vibrational spectra show typical features of boron-rich borides and Zintl phases. Mg{sub 3}B{sub 36}Si{sub 9}C is stable against HF/HNO{sub 3} and conc. NaOH. The micro-hardness is 17.0 GPa (Vickers) and 14.5 GPa (Knoop), respectively. According to simple electron counting rules Mg{sub 3}B{sub 36}Si{sub 9}C is an electron precise compound. Band structure calculations reveal a band gap of 1.0 eV in agreement to the black colour. Interatomic distances obtained from the refinement of X-ray data are biased and falsified by the disorder of the SiC-dumbbell. The most evident structural parameters were obtained by relaxation calculation. Composition and carbon content were confirmed by WDX measurements. The small but significant carbon content is necessary by structural reasons and frequently caused by contaminations. The rare earth compounds RE{sub 3−x}B{sub 36}Si{sub 9}C (RE=Y, Dy–Lu) are isotypic. Single crystals were grown from a silicon melt and their structures refined. The partial occupation of the RE-sites fits to the requirements of an electron-precise composition. According to the displacement parameters a relaxation should be applied to obtain correct structural parameters. - Graphical abstract: Single crystals of the new boridesilicide Mg{sub 3}B{sub 36}Si{sub 9}C were obtained from the elements in a Si-melt. Besides B{sub 12}-icosahedra and ethan-like Si{sub 8}-units it contains a disordered SiC-dumbbell. Correct distances were obtained by relaxation calculation based on the X-ray data. Highlights: • Black single crystals of Mg{sub 3}B{sub 36}Si{sub 9}C were yielded from the elements at 1600 °C. • The rare earth compounds RE{sub 3–x}B{sub 36}Si{sub 9}C (RE=Y, Gd–Lu) are isotypic. • Correct structural parameters result from X-ray data and subsequent relaxation.

36 MATERIALS SCIENCE↗

A low-voltage retarding-field Mott polarimeter for photocathode characterization

Nuclear physics experiments at Thomas Jefferson National Accelerator Facility's CEBAF rely on high polarization electron beams. We describe a recently commissioned system for prequalifying and studying photocathodes for CEBAF with a load-locked, low-voltage polarized electron source coupled to a compact retarding-field Mott polarimeter. The polarimeter uses simplified electrode structures and operates from 5 to 30 kV. The effective Sherman function for this device has been calibrated by comparison with the CEBAF 5 MeV Mott polarimeter. For elastic scattering from a thick gold target at 20 keV, the effective Sherman function is 0.201(5). Its maximum efficiency at 20 keV, defined as the detected count rate divided by the incident particle current, is 5.4(2)×10 -4 , yielding a figure-of-merit, or analyzing power squared times efficiency, of 1.0(1)×10 -5 . The operating parameters of this new polarimeter design are compared to previously published data for other compact Mott polarimeters of the retarding-field type.

43 PARTICLE ACCELERATORS↗

An Efficient Implementation of the Gliding Box Lacunarity Algorithm

Lacunarity is a measure of how data fills space. It complements fractal dimension, which measures how much space is filled. Currently, many researchers use the gliding box algorithm for calculating lacunarity. This paper introduces a fast algorithm for making this calculation. The algorithm presented is akin to fast box counting algorithms used by some researchers in estimating fractal dimension. A simplified gliding box measure equation along with key pseudo code implementations for the algorithm are presented. Applications for the gliding box lacunarity measure have included subjects that range from biological community modeling to target detection.

99 GENERAL AND MISCELLANEOUS↗

MO-G-17A-07: Improved Image Quality in Brain F-18 FDG PET Using Penalized-Likelihood Image Reconstruction Via a Generalized Preconditioned Alternating Projection Algorithm: The First Patient Results

Purpose: To investigate the performance of a new penalized-likelihood PET image reconstruction algorithm using the 1{sub 1}-norm total-variation (TV) sum of the 1st through 4th-order gradients as the penalty. Simulated and brain patient data sets were analyzed. Methods: This work represents an extension of the preconditioned alternating projection algorithm (PAPA) for emission-computed tomography. In this new generalized algorithm (GPAPA), the penalty term is expanded to allow multiple components, in this case the sum of the 1st to 4th order gradients, to reduce artificial piece-wise constant regions (“staircase” artifacts typical for TV) seen in PAPA images penalized with only the 1st order gradient. Simulated data were used to test for “staircase” artifacts and to optimize the penalty hyper-parameter in the root-mean-squared error (RMSE) sense. Patient FDG brain scans were acquired on a GE D690 PET/CT (370 MBq at 1-hour post-injection for 10 minutes) in time-of-flight mode and in all cases were reconstructed using resolution recovery projectors. GPAPA images were compared PAPA and RMSE-optimally filtered OSEM (fully converged) in simulations and to clinical OSEM reconstructions (3 iterations, 32 subsets) with 2.6 mm XYGaussian and standard 3-point axial smoothing post-filters. Results: The results from the simulated data show a significant reduction in the 'staircase' artifact for GPAPA compared to PAPA and lower RMSE (up to 35%) compared to optimally filtered OSEM. A simple power-law relationship between the RMSE-optimal hyper-parameters and the noise equivalent counts (NEC) per voxel is revealed. Qualitatively, the patient images appear much sharper and with less noise than standard clinical images. The convergence rate is similar to OSEM. Conclusions: GPAPA reconstructions using the 1{sub 1}-norm total-variation sum of the 1st through 4th-order gradients as the penalty show great promise for the improvement of image quality over that currently achieved with clinical OSEM reconstructions.

60 APPLIED LIFE SCIENCES↗

Six “beyond Collins and Sivers” transverse spin asymmetries at COMPASS

COMPASS is a fixed-target high energy physics experiment at the SPS at CERN [1]. One of the important objectives of the experiment is the exploration of the transverse spin structure of the nucleon via spin dependent azimuthal asymmetries in single-hadron production in deep inelastic scattering of polarized leptons off transversely polarized target. For this purpose a series of measurements were made in COMPASS, using 160 GeV/c longitudinally polarized muon beam and transversely polarized {sup 6}LiD (in 2002, 2003 and 2004) and NH{sub 3} (in 2007 and 2010) targets. Till now main attention was focused on Collins and Sivers asymmetries and obtained results play an important role in the general understanding of the three-dimensional nature of the nucleon and mechanism of SIDIS processes in terms of Transverse Momentum Dependent (TMD) Parton Distribution Functions (PDFs) and Fragmentation Functions (FFs). In addition to these two measured leading-twist effects, the SIDIS cross-section counts six more target transverse spin dependent azimuthal effects, which have their own well defined leading or higher-twist interpretation in terms of QCD parton model. So far COMPASS presented preliminary results for these asymmetries from deuteron [2, 3] and “proton-2007” data [4]. In this contribution we review the results obtained with the last “proton-2010” data sample.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lifetime measurements of 214Po and 212Po with the CTF liquid scintillator detector at LNGS

We have studied the alpha decays of 214Po into 210Pb and of 212Po into 208Pb tagged by the coincidence with the preceding beta decays from 214Bi and 212Bi, respectively. The employed 222Rn, 232Th, and 220Rn sources were sealed inside quartz vials and inserted in the Counting Test Facility at the underground Gran Sasso National Laboratory in Italy. We find that the mean lifetime of 214Po is (236.00 +- 0.42(stat) +- 0.15(syst)) \mu s and that of 212Po is (425.1 +- 0.9(stat) +- 1.2(syst)) ns. Our results, obtained from data with signal-to-background ratio larger than 1000, reduce the overall uncertainties and are compatible with previous measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data Files for 'The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure'

This data set includes modeling results from The 2030 National Charging Network: Estimating U.S. Light-Duty Demand for Electric Vehicle Charging Infrastructure, including region-specific (i.e., national, state, and core-based statistical area cities and towns) electric vehicle supply equipment port count requirements in 2025 and 2030 for multiple scenarios described in the study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of the NPOD3 Detectors in MCNP5 and MCNP6

Researchers performed a series of measurements in May 2012 to characterize the NPOD3 detector systems. The detectors were placed in varying states of disassembly to determine the effect of individual components on detection efficiency. A 4.5 kg α-phase Pu sphere known as the Los Alamos BeRP Ball was used as the SNM source in both a bare configuration and reflected by varying thicknesses of polyethylene. A set of simulations matching the experimental setups were run and the data were compared to the measured data. The total and leakage multiplication and the inferred k values were determined for both the simulations and the measurements. Table 3 shows a comparison of the results from MCNP6 and MCNP5 with the list-mode patch to the measured results. The count rates for the calculated results were obtained by dividing the total line count in the list-mode file (equivalent to the total number of absorptions in the NPOD detectors) by the total run time. The count rates are identical for both codes, and they both produce the same multiplicity and inferred k values regardless of measurement time as expected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗