Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Evaluating Long-Term Changes in Atmospheric Ozone

Ozonesondes have made inexpensive, accurate measurements of ozone from the ground to 30km for more than 50 years. The data are used extensively for trend analyses and for evaluation of satellite and model data products, and are also part of climatologies that are used as a priori data for satellite retrievals. They are essential as a transfer standard when merging shorter satellite-derived time series, and are the most important source of trend-quality long-term records below about 18 km. The importance of long-term ozonesonde records as a stable reference has led to increased attention to quantifying uncertainties and changes in ozonesonde data. Based on past intercomparison data, ECC sondes show a modest (~1-5%) high bias with respect to UV-absorption measurements (including MOZAIC-IAGOS) in the troposphere, with an uncertainty of 5%, but no evidence of a change with time. Other sonde types show an increase of 5-20% in sensitivity to tropospheric ozone from 1970-1995. Agreement in the stratosphere is much better. In the past 20 years ozonesonde precision has improved by a factor of 2, primarily through the adoption of strict standard operating procedures. In addition, many of the most important ozonesonde records have been re-evaluated and corrected, and detailed estimates made of their biases and uncertainties. Corrections to historical data for known issues may reduce biases but simultaneously introduce additional uncertainties. The uncertainty budget for the ozone partial pressure reading has contributions from stoichiometry, cell background current, pump efficiency and temperature, sensing solution type and volume. The much-discussed “background current” has recently been shown to be primarily related to reaction stoichiometry. Several quality assurance issues remain, but are tractable problems that can be addressed with further research. This will be required if the present goal of better than 5% overall uncertainty throughout the global ozonesonde network is to be achieved. Finally, the importance of regular sonde intercomparisons, employing UV photometers traceable to the modern UV-absorption standard, and of regular comparison of operational station records with multiple satellite sensors, is emphasized.

Ozonesondes↗

Soft x-ray optical constants of sputtered chromium thin films with improved accuracy in the L and M absorption edge regions

In this paper, we determine with improved accuracy the complex index of refraction n = 1 - δ + iβ of sputtered chromium thin films for photon energies ranging from 25 eV to 813 eV. These data include the first absolute measurements of the absorption fine structure near the Cr-L edge. First, we verified by combining Rutherford Backscattering Spectrometry and grazing-incidence x-ray reflectometry that the sputtered thin films were pure Cr with a density consistent with tabulated values. Then, we demonstrated that the Cr surface oxide layer remains stable when the samples are exposed to air for up to 4 years. The Cr absorption coefficient β was determined from the transmittance of freestanding Cr thin films with various thicknesses, measured at the ALS synchrotron radiation source. A model is proposed to correct the transmittance data from the spectral contamination of the source. Finally, we used the new β values, combined with theoretical and tabulated data from the literature, in order to calculate the δ values by the Kramers-Kronig relation. The improvement in the accuracy of β values is demonstrated by the f-sum rule. Finally, an additional validation of the new Cr optical constants (δ, β) is performed by comparing the simulated and experimental reflectance of a Cr/B 4 C multilayer mirror near the Cr-L 2,3 edge.

36 MATERIALS SCIENCE↗

TH-C-BRD-06: A Novel MRI Based CT Artifact Correction Method for Improving Proton Range Calculation in the Presence of Severe CT Artifacts

Purpose: Severe CT artifacts can impair our ability to accurately calculate proton range thereby resulting in a clinically unacceptable treatment plan. In this work, we investigated a novel CT artifact correction method based on a coregistered MRI and investigated its ability to estimate CT HU and proton range in the presence of severe CT artifacts. Methods: The proposed method corrects corrupted CT data using a coregistered MRI to guide the mapping of CT values from a nearby artifact-free region. First patient MRI and CT images were registered using 3D deformable image registration software based on B-spline and mutual information. The CT slice with severe artifacts was selected as well as a nearby slice free of artifacts (e.g. 1cm away from the artifact). The two sets of paired MRI and CT images at different slice locations were further registered by applying 2D deformable image registration. Based on the artifact free paired MRI and CT images, a comprehensive geospatial analysis was performed to predict the correct CT HU of the CT image with severe artifact. For a proof of concept, a known artifact was introduced that changed the ground truth CT HU value up to 30% and up to 5cm error in proton range. The ability of the proposed method to recover the ground truth was quantified using a selected head and neck case. Results: A significant improvement in image quality was observed visually. Our proof of concept study showed that 90% of area that had 30% errors in CT HU was corrected to 3% of its ground truth value. Furthermore, the maximum proton range error up to 5cm was reduced to 4mm error. Conclusion: MRI based CT artifact correction method can improve CT image quality and proton range calculation for patients with severe CT artifacts.

60 APPLIED LIFE SCIENCES↗

The NEEDS Data Base Management and Archival Mass Memory System

A Data Base Management System and an Archival Mass Memory System are being developed that will have a 10 to the 12th bit on-line and a 10 to the 13th off-line storage capacity. The integrated system will accept packetized data from the data staging area at 50 Mbps, create a comprehensive directory, provide for file management, record the data, perform error detection and correction, accept user requests, retrieve the requested data files and provide the data to multiple users at a combined rate of 50 Mbps. Stored and replicated data files will have a bit error rate of less than 10 to the -9th even after ten years of storage. The integrated system will be demonstrated to prove the technology late in 1981.

Bailey, G. A.↗

Thermal and Nonthermal Electron-ion Bremsstrahlung Spectrum from High-Temperature Plasmas

Electron-ion bremsstrahlung radiation from high-temperature plasmas is investigated. The first- and second-order Coulomb corrections in the nonrelativistic bremsstrahlung radiation power are obtained by the Elwert-Sommerfeld factor. In this paper, two cases of the electron distributions, the thermal and nonthermal power-law distributions, are considered. The inclusion of Coulomb corrections is necessary in deducing correctly the electron distribution function from radiation data. These results provide the correct information of electron distributions in high-temperature plasmas, such as in inertial confinement fusion plasmas and in the astrophysical hot thermal and nonthermal x-ray sources.

Jung, Young-Dae↗

Correction Technique for Raman Water Vapor Lidar Signal-Dependent Bias and Suitability for Water Wapor Trend Monitoring in the Upper Troposphere

The MOHAVE-2009 campaign brought together diverse instrumentation for measuring atmospheric water vapor. We report on the participation of the ALVICE (Atmospheric Laboratory for Validation, Interagency Collaboration and Education) mobile laboratory in the MOHAVE-2009 campaign. In appendices we also report on the performance of the corrected Vaisala RS92 radiosonde measurements during the campaign, on a new radiosonde based calibration algorithm that reduces the influence of atmospheric variability on the derived calibration constant, and on other results of the ALVICE deployment. The MOHAVE-2009 campaign permitted the Raman lidar systems participating to discover and address measurement biases in the upper troposphere and lower stratosphere. The ALVICE lidar system was found to possess a wet bias which was attributed to fluorescence of insect material that was deposited on the telescope early in the mission. Other sources of wet biases are discussed and data from other Raman lidar systems are investigated, revealing that wet biases in upper tropospheric (UT) and lower stratospheric (LS) water vapor measurements appear to be quite common in Raman lidar systems. Lower stratospheric climatology of water vapor is investigated both as a means to check for the existence of these wet biases in Raman lidar data and as a source of correction for the bias. A correction technique is derived and applied to the ALVICE lidar water vapor profiles. Good agreement is found between corrected ALVICE lidar measurments and those of RS92, frost point hygrometer and total column water. The correction is offered as a general method to both quality control Raman water vapor lidar data and to correct those data that have signal-dependent bias. The influence of the correction is shown to be small at regions in the upper troposphere where recent work indicates detection of trends in atmospheric water vapor may be most robust. The correction shown here holds promise for permitting useful upper tropospheric water vapor profiles to be consistently measured by Raman lidar within NDACC (Network for the Detection of Atmospheric Composition Change) and elsewhere, despite the prevalence of instrumental and atmospheric effects that can contaminate the very low signal to noise measurements in the UT.

MOHAVE-2009↗

Underground Test Area (UGTA) Sampling Plan for Corrective Action Units 101 and 102: Central and Western Pahute Mesa, Nevada National Security Site, Nevada

The purpose of this groundwater sampling plan (referred to herein as “the Plan”) is to describe the approach for collecting and analyzing groundwater samples to meet the objectives of the U.S. Department of Energy (DOE), Environmental Management (EM) Nevada Program’s Underground Test Area (UGTA) Activity. The Plan is focused on the Central and Western Pahute Mesa corrective action units (CAUs 101 and 102). The remaining UGTA CAUs are in the final stage of the UGTA strategy (Closure Report [CR] stage), and monitoring requirements for these CAUs are described in their respective CRs. The Plan supersedes the Nevada National Security Site Integrated Groundwater Sampling Plan and its ensuing Record of Technical Change (ROTC) (DOE/EMNV, 2019b). The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP) and its ensuing ROTC (DOE/EMNV, 2018), and the Federal Facility Agreement and Consent Order (FFACO) (1996, as amended). The Plan is implemented by the Environmental Program Services (EPS) contractor. Implementation of the Plan provides data to complete corrective actions prescribed by the FFACO to protect the public from groundwater contaminated by historical underground nuclear testing. The Plan’s scope comprises sample collection and analysis requirements for assessing the extent of groundwater contamination from underground nuclear testing. Sampling wells located in the communities surrounding the Nevada National Security Site (NNSS) is performed by other organizations (e.g., management and operating [M&O] contractor) and is therefore not included within the Plan. The results of the community sampling are presented in the annual NNSS environmental reports.

54 ENVIRONMENTAL SCIENCES↗

Elevation Change of the Southern Greenland Ice Sheet from Satellite Radar Altimeter Data

Long-term changes in the thickness of the polar ice sheets are important indicators of climate change. Understanding the contributions to the global water mass balance from the accumulation or ablation of grounded ice in Greenland and Antarctica is considered crucial for determining the source of the about 2 mm/yr sea-level rise in the last century. Though the Antarctic ice sheet is much larger than its northern counterpart, the Greenland ice sheet is more likely to undergo dramatic changes in response to a warming trend. This can be attributed to the warmer Greenland climate, as well as a potential for amplification of a global warming trend in the polar regions of the Northern Hemisphere. In collaboration with Drs. Curt Davis and Craig Kluever of the University of Missouri, we are using data from satellite radar altimeters to measure changes in the elevation of the Southern Greenland ice sheet from 1978 to the present. Difficulties with systematic altimeter measurement errors, particularly in intersatellite comparisons, beset earlier studies of the Greenland ice sheet thickness. We use altimeter data collected contemporaneously over the global ocean to establish a reference for correcting ice-sheet data. In addition, the waveform data from the ice-sheet radar returns are reprocessed to better determine the range from the satellite to the ice surface. At JPL, we are focusing our efforts principally on the reduction of orbit errors and range biases in the measurement systems on the various altimeter missions. Our approach emphasizes global characterization and reduction of the long-period orbit errors and range biases using altimeter data from NASA's Ocean Pathfinder program. Along-track sea-height residuals are sequentially filtered and backwards smoothed, and the radial orbit errors are modeled as sinusoids with a wavelength equal to one revolution of the satellite. The amplitudes of the sinusoids are treated as exponentially-correlated noise processes with a time-constant of six days. Measurement errors (e.g., altimeter range bias) are simultaneously recovered as constant parameters. The corrections derived from the global ocean analysis are then applied over the Greenland ice sheet. The orbit error and measurement bias corrections for different missions are developed in a single framework to enable robust linkage of ice-sheet measurements from 1978 to the present. In 1998, we completed our re-evaluation of the 1978 Seasat and 1985-1989 Geosat Exact Repeat Mission data. The estimates of ice thickness over Southern Greenland (south of 72N and above 2000 m) from 1978 to 1988 show large regional variations (+/-18 cm/yr), but yield an overall rate of +1.5 +/- 0.5 cm/yr (one standard error). Accounting for systematic errors, the estimate may not be significantly different from the null growth rate. The average elevation change from 1978 to 1988 is too small to assess whether the Greenland ice sheet is undergoing a long-term change.

Haines, Bruce J.↗

An initial analysis of the data from the Polar Orbiting Geophysical (POGS) Satellite

The Polar Orbiting Geophysical Satellite (POGS) was launched in 1990 to measure the geomagnetic field. POGS data from selected magnetically quiet days was chosen, quality checked and deleted where thought to be erroneous. A time and position correction was applied. The resulting data was fit to a degree 13 spherical harmonic model. Evaluation of the quality of the data indicates that it is sufficient for definition of the low degree (approximately less than 8) portion of the geomagnetic field. Further correction of the data time and position may improve this quality.

Langel, R. A.↗

Coso Geothermal Spectral Library for Rocks and Minerals

An integrated open mineral spectral library designed to enhance the utility and precision of mineral spectral data for geothermal exploration, developed from a reliable and comprehensive digital dataset for seamless sharing by integrating field data, the USGS spectral library, and pertinent information obtained from Coso geothermal field (Coso) in California. The ASD FieldSpec portable spectrometer was utilized for collecting spectral data, which was subsequently analyzed using the THOR Material Identification tool in ENVI, The Spectral Geologist (TSG) software by CSIRO, and the Fully Constrained Linear Spectral Unmixing algorithm (FCLSU) in MATLAB. Scanning Electron Microscopy (SEM) with a mineralogy-analyzing function was employed to assess the mineral composition of samples, ensuring precise mineralogical analysis. A portable X-ray fluorescence (pXRF) spectrometer was also utilized to gather information on elemental enrichment. A framework for developing spectra data and establishing spectral libraries for various geological cases was proposed within this study. The characteristic spectra of six alteration minerals - alunite, chalcedony, epidote, hematite, kaolinite, and opal - were acquired from Coso samples. The spectral library for the Coso alteration minerals was introduced for further application in academic study or industrial exploration. To browse the Coso Geothermal Spectral data and related figures from spreadsheets: #1 Unzip and store the following items in the same folder. 'Contact Probe Data.zip', 'Sample Photos.zip', and 'Coso spectra of higher-certainity minerals.xlsx'. #2 Open 'Coso spectra of higher-certainity minerals.xlsx'. The hyperlinks in the spreadsheet lead to the folders or figures of: spectra .asd file, spectra ASC II file, spectra plots, and sample photos. The spectra data is raw data without splice correction. Spectra .asd files require particular software to open. (These cannot be opened in GIS software such as ArcGIS.) Spectra ASC II files can be opened in a text editor or spread sheet program.

15 GEOTHERMAL ENERGY↗

Bias-Correcting Carbon Fluxes Derived From Land-Surface Satellite Data for Retrospective and Near Real-Time Assimilation Systems

The ability to monitor and understand natural and anthropogenic variability in atmospheric carbon dioxide(CO2) is a growing need of many stakeholders across the world. Systems that assimilate satellite observations, given their short latency and dense spatial coverage, into high resolution global models are valuable, if not essential, tools for addressing this need. A notable drawback of modern assimilation systems is the long latency of many vital in-put datasets, e.g., inventories, in situ measurements, and re-processed remote-sensing data can trail the current date by months to years. This paper describes techniques for bias-correcting surface fluxes derived from satellite observations of the Earth’s surface to be consistent with constraints from inventories and in situ CO2 datasets. The techniques are applicable in both short-term forecasts and retrospective simulations, thus taking advantage of the coverage and short latency of satellite data while reproducing the major features of long-term inventory and in situ records. Our approach begins with a standard collection of diagnostic fluxes which incorporate a variety of remote-sensing driver data, viz. vegetation indices, fire radiative power, and nighttime lights. We then apply an empirical sink so that global budgets of the diagnostic fluxes match given atmospheric and oceanic growth rates for each year. This step removes coherent, systematic flux errors that produce biases inCO2which mask the signals an assimilation system hopes to capture. Depending on the simulation mode, the empirical sink uses different choices of atmospheric growth rates: estimates based on observations in retrospective mode and projections based on seasonal fore-casts of sea surface temperature in forecasting mode. The retrospective fluxes, when used in simulations with NASA’s Goddard Earth Observing System (GEOS), reproduce marine boundary layer measurements with comparable skill to those using fluxes from a modern inversion system. The forecasted fluxes show promising accuracy in their application to the analysis of changes in the carbon cycle as they occur.

CO2↗

WE-G-18A-02: Calibration-Free Combined KV/MV Short Scan CBCT

Purpose: To combine orthogonal kilo-voltage (kV) and Mega-voltage (MV) projection data for short scan cone-beam CT to reduce imaging time on current radiation treatment systems, using a calibration-free gain correction method. Methods: Combining two orthogonal projection data sets for kV and MV imaging hardware can reduce the scan angle to as small as 110° (90°+fan) such that the total scan time is ∼18 seconds, or within a breath hold. To obtain an accurate reconstruction, the MV projection data is first linearly corrected using linear regression using the redundant data from the start and end of the sinogram, and then the combined data is reconstructed using the FDK method. To correct for the different changes of attenuation coefficients in kV/MV between soft tissue and bone, the forward projection of the segmented bone and soft tissue from the first reconstruction in the redundant region are added to the linear regression model. The MV data is corrected again using the additional information from the segmented image, and combined with kV for a second FDK reconstruction. We simulated polychromatic 120 kVp (conventional a-Si EPID with CsI) and 2.5 MVp (prototype high-DQE MV detector) projection data with Poisson noise using the XCAT phantom. The gain correction and combined kV/MV short scan reconstructions were tested with head and thorax cases, and simple contrast-to-noise ratio measurements were made in a low-contrast pattern in the head. Results: The FDK reconstruction using the proposed gain correction method can effectively reduce artifacts caused by the differences of attenuation coefficients in the kV/MV data. The CNRs of the short scans for kV, MV, and kV/MV are 5.0, 2.6 and 3.4 respectively. The proposed gain correction method also works with truncated projections. Conclusion: A novel gain correction and reconstruction method was developed to generate short scan CBCT from orthogonal kV/MV projections. This work is supported by NIH Grant 5R01CA138426-05.

60 APPLIED LIFE SCIENCES↗

Improved SIFTER v2 algorithm for long-term GOME-2A satellite retrievals of fluorescence with a correction for instrument degradation

Solar-induced fluorescence (SIF) data from satellites are increasingly used as a proxy for photosynthetic activity by vegetation, and as a constraint on gross primary production. Here we report on improvements in the algorithm to retrieve mid-morning (09:30 hrs local time) SIF estimates on the global scale from GOME-2 sensor on the Metop-A satellite (GOME-2A) for the period 2007-2019. Our new SIFTER (Sun-Induced Fluorescence of Terrestrial Ecosystems Retrieval) v2 algorithm improves over a previous version by using a narrower spectral window that avoids strong oxygen absorption and is less sensitive to water vapour absorption, by constructing stable reference spectra from a 6-year period (2007-2012) of atmospheric spectra over the Sahara, and by applying a latitude-dependent zero-level adjustment that accounts for biases in the data product. We generated stable, good-quality SIF retrievals between January 2007 and June 2013, when GOME-2A degradation in the near infrared was still limited. After the narrowing of the GOME-2A swath in July 2013, we characterized the throughput degradation of the level-1 data in order to derive reflectance corrections and apply these for the SIF retrievals between July 2013 and December 2018. SIFTER v2 data compares well with the independent NASA v2.8 data product. Especially in the evergreen tropics, SIFTER v2 no longer shows the underestimates against other satellite products that were seen in SIFTER v1. The new data product includes uncertainty estimates for individual observations, and is best used for mostly clear-sky scenes, and when spectral residuals remain below a certain spectral autocorrelation threshold. Our results support the use of SIFTER v2 data to be used as an independent constraint on photosynthetic activity on regional to global scales.

Solar-induced fluorescence (SIF)↗

Measurement of the underlying event activity in pp collisions at $ \sqrt {s} = 0.9 $ and 7 TeV with the novel jet-area/median approach

The first measurement of the charged component of the underlying event using the novel "jet-area/median" approach is presented for proton-proton collisions at centre-of-mass energies of 0.9 and 7 TeV. The data were recorded in 2010 with the CMS experiment at the LHC. A new observable, sensitive to soft particle production, is introduced and investigated inclusively and as a function of the event scale defined by the transverse momentum of the leading jet. Various phenomenological models are compared to data, with and without corrections for detector effects. None of the examined models describe the data satisfactorily.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effects of ferumoxytol on quantitative PET measurements in simultaneous PET/MR whole-body imaging: a pilot study in a baboon model

Background: Simultaneous PET/MR imaging depends on MR-derived attenuation maps (mu-maps) for accurate attenuation correction of PET data. Currently, these maps are derived from gradient-echo-based MR sequences, which are sensitive to susceptibility changes. Iron oxide magnetic nanoparticles have been used in the measurement of blood volume, tumor microvasculature, tumor-associated macrophages, and characterizing lymph nodes. Our aim in this study was to assess whether the susceptibility effects associated with iron oxide nanoparticles can potentially affect measured 18 F-FDG PET standardized uptake values (SUV) through effects on MR-derived attenuation maps. Methods: The study protocol was approved by the Institutional Animal Care and Use Committee. Using a Siemens Biograph mMR PET/MR scanner, we evaluated the effects of increasing concentrations of ferumoxytol and ferumoxytol aggregates on MR-derived mu-maps using an agarose phantom. In addition, we performed a baboon experiment evaluating the effects of a single i.v. ferumoxytol dose (10 mg/kg) on the liver, spleen, and pancreas 18 F-FDG SUV at baseline (ferumoxytol-naïve), within the first hour and at 1, 3, 5, and 11 weeks. Results: Phantom experiments showed mu-map artifacts starting at ferumoxytol aggregate concentrations of 10 to 20 mg/kg. The in vivo baboon data demonstrated a 53% decrease of observed 18 F-FDG SUV compared to baseline within the first hour in the liver, persisting at least 11 weeks. Conclusions: A single ferumoxytol dose can affect measured SUV for at least 3 months, which should be taken into account when administrating ferumoxytol in patients needing sequential PET/MR scans.

59 BASIC BIOLOGICAL SCIENCES↗

On the flight derived/aerodynamic data base performance comparisons for the NASA Space Shuttle entries during the hypersonic regime

Aerodynamic performance data from the first four Shuttle reentry flights are compared with preflight predictions covering hypersonic longitudinal mode down to Mach 2. The extraction of the flight coefficients, as measured by the spacecraft angular rates and the linear accelerations, derived from the inertial measurement unit, the best estimate trajectory, and the remotely measured atmosphere are discussed. The ground predictions were developed from 30,000 hr of wind tunnel testing. Actual flight data are presented for 80-260 kft, from Mach 2-26, comprising the dynamic pressure, the vehicle air relative attitude angles, control surface deflections, reaction jet activity, and body axis rates and accelerations. The second and fourth flights gave results which deviated from predictions between 230-260 kft. The accuracy limits of the derived atmospheric densities are considered, together with potential data base updates in the light of limitations imposed on the corrections by available flight data.

Findlay, J. T.↗

System and method for transferring data on a data link

A system and method are provided for transferring a packet across a data link. The packet may include a stream of data symbols which is delimited by one or more framing symbols. Corruptions of the framing symbol which result in valid data symbols may be mapped to invalid symbols. If it is desired to transfer one of the valid data symbols that has been mapped to an invalid symbol, the data symbol may be replaced with an unused symbol. At the receiving end, these unused symbols are replaced with the corresponding valid data symbols. The data stream of the packet may be encoded with forward error correction information to detect and correct errors in the data stream.

Cole, Robert M.↗

Harmonic analysis for the characterization and correction of geometric distortion in MRI

Purpose: Magnetic resonance imaging (MRI) is gaining widespread use in radiation therapy planning, patient setup verification, and real-time guidance of radiation delivery. Successful implementation of these technologies relies on the development of simple and efficient methods to characterize and monitor the geometric distortions arising due to system imperfections and gradient nonlinearities. To this end, the authors present the theory and validation of a novel harmonic approach to the quantification of system-related distortions in MRI. Methods: The theory of spatial encoding in MRI is applied to demonstrate that the 3D distortion vector field (DVF) is given by the solution of a second-order boundary value problem (BVP). This BVP is comprised of Laplace’s equation and a limited measurement of the distortion on the boundary of a specified region of interest (ROI). An analytical series expansion solving this BVP within a spherical ROI is obtained, and a statistical uncertainty analysis is performed to determine how random errors in the boundary measurements propagate to the ROI interior. This series expansion is then evaluated to obtain volumetric DVF mappings that are compared to reference data obtained on a 3 T full-body scanner. This validation is performed within two spheres of 20 cm diameter (one centered at the scanner origin and the other offset +3 cm along each of the transverse directions). Initially, a high-order mapping requiring measurements at 5810 boundary points is used. Then, after exploring the impact of the boundary sampling density and the effect of series truncation, a reduced-order mapping requiring measurements at 302 boundary points is evaluated. Results: The volumetric DVF mappings obtained from the harmonic analysis are in good agreement with the reference data. Following distortion correction using the high-order mapping, the authors estimate a reduction in the mean distortion magnitude from 0.86 to 0.42 mm and from 0.93 to 0.39 mm within the central and offset ROIs, respectively. In addition, the fraction of points with a distortion magnitude greater than 1 mm is reduced from 35.6% to 2.8% and from 40.4% to 1.5%, respectively. Similarly, following correction using the reduced-order mapping, the mean distortion magnitude reduces to 0.45–0.42 mm within the central and offset ROIs, and the fraction of points with a distortion magnitude greater than 1 mm is reduced to 2.8% and 1.5%, respectively. Conclusions: A novel harmonic approach to the characterization of system-related distortions in MRI is presented. This method permits a complete and accurate mapping of the DVF within a specified ROI using a limited measurement of the distortion on the ROI boundary. This technique eliminates the requirement to exhaustively sample the DVF at a dense 3D array of points, thereby permitting the design of simple, inexpensive phantoms that may incorporate additional modules for auxiliary quality assurance objectives.

62 RADIOLOGY AND NUCLEAR MEDICINE↗