Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “contacts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Mitigation of the internal p-n junction in CoS 2 -contacted FeS 2 single crystals: Accessing bulk semiconducting transport

Pyrite FeS 2 is an outstanding candidate for a low-cost, nontoxic, sustainable photovoltaic material, but efficient pyrite-based solar cells are yet to materialize. Recent studies of single crystals have shed much light on this by uncovering a p-type surface inversion layer on n-type (S-vacancy doped) crystals, and the resulting internal p-n junction. This leaky internal junction likely plays a key role in limiting efficiency in pyrite-based photovoltaic devices, also obscuring the true bulk semiconducting transport properties of pyrite crystals. Here, we demonstrate complete mitigation of the internal p-n junction in FeS 2 crystals by fabricating metallic CoS 2 contacts via a process that simultaneously diffuses Co (a shallow donor) into the crystal, the resulting heavy n doping yielding direct Ohmic contact to the interior. Low-temperature bulk transport studies of controllably Co- and S-vacancy doped semiconducting crystals then enable a host of previously inaccessible observations and measurements, including determination of donor activation energies (which are as low as 5 meV for Co), observation of an unexpected second activated transport regime, realization of electron mobility up to 2100 cm 2 V –1 s –1 , elucidation of very different mobilities in Co- and S-vacancy-doped cases, and observation of an abrupt temperaturedependent crossover to bulk Efros-Shklovskii variable-range hopping, accompanied by an unusual form of nonlinear Hall effect. Aspects of the results are interpreted with the aid of first-principles electronic structure calculations on both Co- and S-vacancy-doped FeS 2 . Furthermore, this work thus demonstrates unequivocal mitigation of the internal p-n junction in pyrite single crystals, with important implications for both future fundamental studies and photovoltaic devices

36 MATERIALS SCIENCE↗

Damp Heat Induced Degradation of Silicon Heterojunction Solar Cells With Cu-Plated Contacts

Damp heat exposure is one of the most stringent environments for testing the durability of solar cells in packaged modules. Damp heat stresses and induces a variety of degradation modes in solar cells and modules: for example, moisture-induced corrosion of electrodes and interconnections, deterioration of polymeric materials, and/or thermally activated diffusion processes. To screen for these and other potential degradation modes, we subject one-cell modules containing silicon heterojunction (SHJ) solar cells with Cu-plated contacts to extended damp heat tests at 85 °C/85% relative humidity. SHJ cells were laminated with two common encapsulants: ethylene vinyl acetate (EVA) and polyolefin elastomer (POE), and two constructions: glass-backsheet and glass-glass. We observe degradation in all components of solar cell maximum power (PMP): current, voltage, and fill factor, and find evidence of increased carrier recombination and nonideal diode behavior with increasing stress. For glass-backsheet constructions, EVA samples generally degrade more than POE by a factor of approximately 1.5x PMP, and the different encapsulants produce different degradation patterns. Similar trends are observed in glass-glass modules, but to a lesser degree. In a different experiment, we observe a decrease in effective minority carrier lifetime of nonmetallized SHJ precursors measured after damp heat. This implies that some degradation unrelated to the contacts is to be expected and confirms the observation of increasing recombination.

14 SOLAR ENERGY↗

Differences in Printed Contacts Lead to Susceptibility of Silicon Cells to Series Resistance Degradation

Here, in this case study, we investigate a degradation mode occurring at the cell level in fielded multi-Si modules. The modules exhibit a mix of affected and unaffected cells. Affected cells show a progressive, series-resistance-related power degradation as shown via module- and cell-level IV curves, along with electroluminescence (EL) and PL imaging at the module, cell, and cell core sample scales. Scanning electron microscopy and energy-dispersive X-ray spectroscopy reveal a difference in the oxides in the silver paste used in screen printing of the gridline contacts. The paste in the affected cells is lead rich, whereas the paste in the unaffected cells is zinc rich. This suggests that the cells were screen printed with different silver paste compositions and possibly firing conditions, and that the different composition correlates with the susceptibility to degradation. Our results indicate degradation of the contact at the oxide-silver interface, causing a severe increase in series resistance across the cell that continues to progress over time.

14 SOLAR ENERGY↗

High-Quality Cross-Sectioning Method: Examples of Applications in Optimizing Solar Cell Contact Firing

A damage-free polishing method is developed to prepare a high-quality cross-section of a large length of a solar cell. A 1-inch-long sample is diced from the solar cell and embedded in wax using a specially designed chuck. The sample edge is sequentially polished by progressively reducing the grit sizes. The final polishing is done by Chemical Mechanical Polishing (CMP). This polishing procedure produces a highly flat edge, with excellent interfaces between metal contacts and the Si cell. The planarity of the wafer edge makes it possible to perform a variety of analyses of various regions and the interfaces of the cell, using optical microscopy, EDX, scanning electron microscopy (SEM), and conductive AFM (C-AFM). Here, we will discuss some details of the chuck and the polishing procedure, and present some applications for optimizing the contact firing process. This method has an added advantage of delineating the back surface field for optical observation.

14 SOLAR ENERGY↗

Atmospheric-Pressure Processed Silver Nanowire (Ag-NW)/ZnO Composite Transparent Conducting Contacts

Composite transparent contacts (TCs) based on metal nanowires and metal oxide matrix materials hold great promise for high performance transparent contacts for photovoltaics and opto-electronic technologies with the potential of all-atmospheric pressure processing. The metal nanowire mesh can provide both electrical conductivity and mechanical robustness against bending while the matrix material can both control the electrical interface and protect the metal nanowires. Here, we demonstrate all atmospheric pressure processed Ag-NW/ZnO composite TCs that are 90% transparent in the visible with sheet resistance Rs ~= 10 Ohms/sq. In addition, the composite TCs have higher infrared transmission than conventional TCO films with the same sheet resistance.

14 SOLAR ENERGY↗

23% efficient n-type crystalline silicon solar cells with passivated partial rear contacts

© 2018 IEEE. Over the past three years a new family of high efficiency n-type crystalline silicon cells featuring passivated partial rear contacts (PRC) has emerged. These cells take advantage of the unique contact properties obtained by introducing thin metal compound interlayers, such as TiO x and LiFx, between the metallic electrode and the silicon absorber. This paper explores the concept and potential advantages of the n-type passivated PRC cell. In particular, the recent fabrication of a cell at 23.1%, featuring a less-than 1% TiOx/LiFx /Al passivated PRC, demonstrates the compatibility of this concept with high efficiency designs.

Bullock, James↗

Transmission Electron Microscopy Studies of Transition Metal Oxides Employed as Carrier Selective Contacts in Silicon Solar Cells

The focus of this work is on the nano-scale characterization of transition metal oxides employed as carrier selective contacts in crystalline silicon (c-Si) solar cells using crosssectional transmission electron microscopy (TEM). Both electronselective (titanium dioxide, TiO 2 ) and hole-selective (molybdenum oxide, MoO x ; tungsten oxide, WO x ) contacts were investigated. High-resolution TEM (HRTEM) images were obtained with a FEI Tecnai F30 TEM.

Ali, H↗

Enhancing Photocarrier Bulk Lifetime with Defect Engineering of Polycrystalline Passivated-Contact n-Cz Photovoltaic Devices

We study the photocarrier lifetime evolution of n-Cz Si material throughout the processing sequence for polycrystalline passivated contact devices. We show that a high temperature annealing pretreatment (known as Tabula Rasa) has a clear effect on enhancing bulk lifetimes of n-Cz Si. We further this development by integrating such defect engineering into the lower-temperature annealing of passivated contact. By applying oxidizing ambient gases during these anneals we report a photocarrier lifetime enhancement over an N 2 environment. This enhancement is exhibited in a 1-sun iV OC of 735 mV when annealed in O 2 rather than 708 mV in N 2.

14 SOLAR ENERGY↗

Electron and hole partial specific resistances: a framework to understand contacts to solar cells

In order to understand how contacts influence the performance of solar cells, we previously developed and presented the concept of partial specific resistances: for each contact of a solar cell, we defined voltage-dependent specific resistances to electrons and to holes. Although the connection between these partial specific resistances and the cell performance metrics at open circuit (iV oc and V oc ) is straightforward, the relationship becomes more complex when current flows out of the cell, in particular at the maximum power point. In the present work, we investigate the dependence of these hole and electron specific resistances on implied voltage. We show that the shapes of these curves-and not simply the resistance values at the maximum power point, which do not correspond to the same injection level in every cell-dictate the cell efficiency.

Onno, Arthur↗

Absence of clinical disease and contact transmission of HPAI H5NX clade 2.3.4.4 from North America in experimentally infected pigs

Background In the fall of 2014, highly pathogenic avian influenza (HPAI) subtype H5N8 clade 2.3.4.4 was introduced into North America by migrating waterfowl from Asia where, through reassortment, novel HPAI H5N2 and H5N1 viruses emerged. Objectives Assess the susceptibility of pigs to HPAI H5N1, H5N2, and H5N8 clade 2.3.3.3 from North America. Methods Pigs and trachea explants were inoculated with a representative panel of H5NX clade 2.3.4.4 HPAI viruses from North America. Nasal swabs, BALF, and sera were collected to assess replication and transmission in challenged and direct contact pigs by RRT‐PCR, virus isolation, hemagglutination inhibition, and ELISA. Results Limited virus replication was restricted to the lower respiratory tract of challenged pigs, though absent in the nasal passages and trachea cultures, as determined by RRT‐PCR in all samples. Seroconversion of inoculated pigs was detected by NP ELISA but was not reliably detected by antigen‐specific hemagglutination inhibition. Boost with adjuvanted virus was required for the production of neutralizing antibodies to assess cross‐reactivity between wild‐type avian strains. All RRT‐PCR and serology tests were negative for contact animals indicating a failure of transmission from primary inoculated pigs. Conclusions H5NX clade 2.3.4.4 strains can replicate in the lower respiratory tract of swine upon high titer inoculation, though appear to be incapable of replication in swine nasal epithelium in vivo or ex vivo in trachea explants in culture. Infected pigs did not produce high levels of serum antibodies following infection. Collectively, our data show HPAI H5NX clade 2.3.4.4 viruses to be poorly adapted for replication and transmission in swine.

H5↗

Novel Experimental Study of Fabric Drying Using Direct-Contact Ultrasonic Vibration

Here, fabric drying is an energy-intensive process, which generally involves blowing hot dry air across tumbling wet fabric to facilitate evaporation and moisture removal. Most of the energy supplied is used to overcome the enthalpy of vaporization for water. Although this process tends to be inefficient, it is fairly simple and forms the basis for the majority of existing clothes dryer technology today. To address the relatively low efficiency, a new method of drying called “direct contact ultrasonic fabric drying” is proposed. The process involves using high-frequency vibration introduced by piezoelectric transducers, which are in contact with wet fabric. The vibration is used to extract water droplets from the fabric mechanically. In this study, a total of 24 individual transducers are used in a module to dry a 142 cm 2 sized fabric. The performance characterization of this single module has enabled successful scale-up of the system to a midscale prototype dryer, which can be used to ultrasonically dry clothing-sized fabric (~750 cm 2 ). The first-generation ultrasonic fabric dryer fabricated uses as little as 17% of the energy needed by traditional evaporation-based drying techniques. In addition to experimental data, this paper presents the results of a kinetic and scaling analysis that provides some important insights into ultrasonic drying.

42 ENGINEERING↗

An Analytical Solution for the Initiation and Early Progression of Fretting Wear in Spherical Contacts

Abstract This article derives analytical solutions to calculate the wear volume at the initiation of fretting motion and its early progression over the first few oscillation cycles. The Archard-based model considers a deformable hemisphere that is contact with a deformable flat block. The material pairs investigated are special alloys, the Inconel 617/Incoloy 800H, and Inconel 617/Inconel 617. The analytical study begins with a unidirectional frictional sliding contact, where the local interfacial sliding distance and the nominal sliding distance at the initiation of gross slip are derived. The obtained analytical expressions for unidirectional sliding are then used to derive the corresponding wear volume for the initiation and early progression of gross slip and the wear volume for a general fretting cycle under elastic conditions. These analytical derivations are all verified by the finite element analysis (FEA). The FEA method and the analytical solutions render virtually identical results for both similar and dissimilar material pairs. The effects of plasticity on the wear volume under elastic–plastic conditions are also investigated. It is found that the fretting wear volumes obtained from the FEA simulations, which include plasticity, are close to those obtained from the analytical expressions for purely elastic regimes. All the results are presented in normalized forms, which can be easily generalized and applied to three-dimensional fretting wear of other material pairs.

Engineering↗

Effects of Water Contamination on Micropitting and Rolling Contact Fatigue of Bearing Steels

Abstract In this research, the effects of water contamination in oil were investigated on two kinds of failures that occur in bearing steel: micropitting and rolling contact fatigue. Whereas the presence of water in the oil had little effect on the generation of surface wear in these experiments, increases in the occurrences of micropitting and rolling contact fatigue were observed due to the presence of either dissolved or free water in lubricants. Additionally, the presence of white etching matter at crack interfaces was observed and evaluated. The experimental results showed that water content can be considered as a significant factor that accelerates the formation of micropitting and fatigue cracks in rolling bearings.

Engineering↗

Rolling contact fatigue in high vacuum using ion plated nickel-copper-silver solid lubrication

Ion plated, nickel-copper-silver coated steel ball bearings that were tested in rolling contact fatigue (RCF) experiments in high vacuum are presented in this article. ANSI T5 ball bearings were coated with approximately 10 nm of nickel-copper followed by 100 nm of silver using a dc ion plating process. The balls were then tested for RCF in vacuum in the 10{sup -7} Torr range at 130 Hz rotational speed and at 4.1 GPa Hertzian contact stress. The significance of this work is in the extension of RCF testing to an ultrahigh vacuum (UHV) application using silver as a lubricant instead of oil. The effects of pressure and voltage on the ion plating process were also investigated using scanning electron microscopy and RCF life testing in UHV. Test results with a ball size of 5/16 in. in UHV show that deposition at voltages greater than 2.5 kV shortens the RCF life and introduces a unique failure mode. Voltage and pressure fluctuations during the deposition process result in significant thickness monitor measurement errors as well. A regulator control scheme that minimizes the process pressure overshoot is also simulated.

36 MATERIALS SCIENCE↗

Effects of chemical intermixing on electrical and thermal contact conductances at metallized bismuth and antimony telluride interfaces

Tailoring electrical and thermal contact conductivities (Σ{sub c} and Γ{sub c}) across metallized pnictogen chalcogenide interfaces is key for realizing efficient thermoelectric devices. The authors report that Cu, Ni, Ti, and Ta diffusion and interfacial telluride formation with n-Bi{sub 2}Te{sub 3} and p-Sb{sub 2}Te{sub 3} influence both Σ{sub c} and Γ{sub c}. Cu metallization yields the highest Γ{sub c} and the lowest Σ{sub c}, correlating with maximal metal diffusion and copper telluride formation. Ni diffuses less and yields the highest Σ{sub c} with Sb{sub 2}Te{sub 3} due to p-type nickel telluride formation, which diminishes Σ{sub c} improvement with n-Bi{sub 2}Te{sub 3} interfaces. Ta and Ti contacts yield the lowest properties similar to that in Ni-metallized structures. These correlations between interfacial diffusion and phase formation on electronic and thermal transport properties will be important for devising suitable metallization for thermoelectric devices.

42 ENGINEERING↗

Hybrid Contacts for CZT Virtual Frisch-grid Detectors

In our previous design of virtual Frisch-grid CdZnTe (CZT) detectors, the charge drift-lines can be terminated at the side surfaces before the carriers reach the collecting anode; this results in a loss of signal from the interacting events near the detector's edges. Here, we describe our new design for the anode contact that reduces these edge effects by focusing the electric field towards the detectors' central axes. Four detectors were fabricated with the new hybrid anode contact, and their performances were evaluated and compared to those from the previous design for our virtual Frisch-grid detectors. The results obtained for all four showed similar improvement: therefore, we illustrate them with the findings from one detector.

54 ENVIRONMENTAL SCIENCES↗

TU-E-201-03: Eye Lens Dosimetry in Radiotherapy Using Contact Lens-Shaped Applicator

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗