Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “compressor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Effect of Various Blade Modifications on Performance of a 16-Stage High-pressure-ratio Axial-flow Compressor.Angles 3 deg: Effect on Over-all Performance Characteristics of Decreasing Twelfth Through Fifteenth State Stator-blade Angles 3 deg - 1

The stator-blade angles in the twelfth to fifteenth stages of a 16-stage high-pressure-ratio axial-flow compressor were decreased 3 deg The over-all performance of this compressor is compared with the performance of the same compressor with standard blade angles. The matching characteristics of the modified compressor and a two-stage turbine were also obtained and compared with those of the compressor with the original blade angles and the same turbine.

Medeiros, Arthur A.↗

Vapor-Compression Heat Pumps for Operation Aboard Spacecraft

Vapor-compression heat pumps (including both refrigerators and heat pumps) of a proposed type would be capable of operating in microgravity and would be safe to use in enclosed environments like those of spacecraft. The designs of these pumps would incorporate modifications of, and additions to, vapor-compression cycles of heat pumps now used in normal Earth gravitation, in order to ensure efficiency and reliability during all phases of operation, including startup, shutdown, nominal continuous operation, and peak operation. Features of such a design might include any or all of the following: (1) Configuring the compressor, condenser, evaporator, valves, capillary tubes (if any), and controls to function in microgravitation; (2) Selection of a working fluid that satisfies thermodynamic requirements and is safe to use in a closed crew compartment; (3) Incorporation of a solenoid valve and/or a check valve to prevent influx of liquid to the compressor upon startup (such influx could damage the compressor); (4) Use of a diode heat pipe between the cold volume and the evaporator to limit the influx of liquid to the compressor upon startup; and (5) Use of a heated block to vaporize any liquid that arrives at the compressor inlet.

Ruemmele, Warren↗

Development of a Battery-Free Solar Refrigerator

Recent technology developments and a systems engineering design approach have led to the development of a practical battery-free solar refrigerator as a spin-off of NASA's aerospace refrigeration research. Off-grid refrigeration is a good application of solar photovoltaic (PV) power if thermal storage is incorporated and a direct connection is made between the cooling system and the PV panel. This was accomplished by integrating water as a phase-change material into a well insulated refrigerator cabinet and by developing a microprocessor based control system that allows direct connection of a PV panel to a variable speed compressor. This second innovation also allowed peak power-point tracking from the PV panel and elimination of batteries from the system. First a laboratory unit was developed to prove the concept and then a commercial unit was produced and deployed in a field test. The laboratory unit was used to test many different configurations including thermoelectric, Stirling and vapor compression cooling systems. The final configuration used a vapor compression cooling cycle, vacuum insulation, a passive condenser, an integral evaporator/ thermal storage tank, two 77 watt PV panels and the novel controller mentioned above. The system's only moving part was the variable speed BD35 compressor made by Danfoss. The 365 liter cabinet stayed cold with as little as 274 watt-hours per day average PV power. Battery-free testing was conducted for several months with very good results. The amount of thermal storage, size of compressor and power of PV panels connected can all be adjusted to optimize the design for a given application and climate. In the commercial unit, the high cost of the vacuum insulated refrigerator cabinet and the stainless steel thermal storage tank were addressed in an effort to make the technology commercially viable. This unit started with a 142 liter, mass-produced chest freezer cabinet that had the evaporator integrated into its inner walls. Its compressor was replaced with a Danfoss DC compressor slightly larger than the one used in the laboratory unit. The control system was integrated onto a single electronics card and packaged with its starting capacitors. The water for thermal storage was placed behind a liner that was made to fit inside the original factory liner. The original condenser was also augmented with additional surface area to improve performance. PV panels with a total rated power of 180 watts were used. The unit was tested with very successful results in an outside ambient environment, demonstrating its potential for widespread use in many off-grid applications for solar refrigeration.

Ewert, Michael K.↗

2012 Ground Testing Highlights

As part of the Fundamental Aeronautics Program and a collaborative effort with Boeing, and Lockheed Martin this past year a series of sonic boom test were completed in the NASA Ames Unitary Plan Wind Tunnel (UPWT). One of the goals was to develop new test techniques and hardware for measuring sonic boom signatures in the transonic and supersonic regimes. Data for various model designs and configurations were collected and will be used to validate CFD predictions of sonic boom signatures. Reactivation of the NASA Ames Mitsubishi compressor system was completed this past year. The compressor is intended to replace and augment the existing UPWT Clark Compressor as the primary Make Up Air (MUA) source. The MUA system provides air and vacuum pumping capability to the Ames UPWT. It will improve productivity and reliability of the UPWT as a vital testing and research facility for the U.S. aerospace industry and NASA. Funding for this task was provided from the American Recovery Investment Act (ARRA). Installation and validation of a Noncontact Stress Monitoring System (NSMS) for the 3-stage compressor was completed at the 11-foot Transonic Wind Tunnel. The system, originally developed at AEDC, consists of 36 pairs of LED light sources with optic beam send and receive probes along a 1-per rev signal. The new system allows for continuous monitoring and recording of compressor blade bending and torsion stress during normal test operations. A very unusual test was completed in the 11 FT TWT to acquire aerodynamic and flow field data for the Crew Exploration Vehicle (CEV) Parachute Assembly System (CPAS) to validate CFD methods and tools. Surface pressure distribution measurements and velocity measurements in the wake of the command module back to the drogues parachute location were acquired. Testing methods included Particle Image Velocimetry (PIV), Pressure Sensitive Paint (PSP), Schlieren Infrared Imaging (IR) and boundary layer survey and skin friction.

Buchholz, Steven J.↗

Modeling Commercial Turbofan Engine Icing Risk With Ice Crystal Ingestion

The occurrence of ice accretion within commercial high bypass aircraft turbine engines has been reported under certain atmospheric conditions. Engine anomalies have taken place at high altitudes that have been attributed to ice crystal ingestion, partially melting, and ice accretion on the compression system components. The result was degraded engine performance, and one or more of the following: loss of thrust control (roll back), compressor surge or stall, and flameout of the combustor. As ice crystals are ingested into the fan and low pressure compression system, the increase in air temperature causes a portion of the ice crystals to melt. It is hypothesized that this allows the ice-water mixture to cover the metal surfaces of the compressor stationary components which leads to ice accretion through evaporative cooling. Ice accretion causes a blockage which subsequently results in the deterioration in performance of the compressor and engine. The focus of this research is to apply an engine icing computational tool to simulate the flow through a turbofan engine and assess the risk of ice accretion. The tool is comprised of an engine system thermodynamic cycle code, a compressor flow analysis code, and an ice particle melt code that has the capability of determining the rate of sublimation, melting, and evaporation through the compressor flow path, without modeling the actual ice accretion. A commercial turbofan engine which has previously experienced icing events during operation in a high altitude ice crystal environment has been tested in the Propulsion Systems Laboratory (PSL) altitude test facility at NASA Glenn Research Center. The PSL has the capability to produce a continuous ice cloud which are ingested by the engine during operation over a range of altitude conditions. The PSL test results confirmed that there was ice accretion in the engine due to ice crystal ingestion, at the same simulated altitude operating conditions as experienced previously in flight. The computational tool was utilized to help guide a portion of the PSL testing, and was used to predict ice accretion could also occur at significantly lower altitudes. The predictions were qualitatively verified by subsequent testing of the engine in the PSL. The PSL test has helped to calibrate the engine icing computational tool to assess the risk of ice accretion. The results from the computer simulation identified prevalent trends in wet bulb temperature, ice particle melt ratio, and engine inlet temperature as a function of altitude for predicting engine icing risk due to ice crystal ingestion.

Jorgenson, Philip C. E.↗

Modeling of Commercial Turbofan Engine With Ice Crystal Ingestion: Follow-On

The occurrence of ice accretion within commercial high bypass aircraft turbine engines has been reported under certain atmospheric conditions. Engine anomalies have taken place at high altitudes that have been attributed to ice crystal ingestion, partially melting, and ice accretion on the compression system components. The result was degraded engine performance, and one or more of the following: loss of thrust control (roll back), compressor surge or stall, and flameout of the combustor. As ice crystals are ingested into the fan and low pressure compression system, the increase in air temperature causes a portion of the ice crystals to melt. It is hypothesized that this allows the ice-water mixture to cover the metal surfaces of the compressor stationary components which leads to ice accretion through evaporative cooling. Ice accretion causes a blockage which subsequently results in the deterioration in performance of the compressor and engine. The focus of this research is to apply an engine icing computational tool to simulate the flow through a turbofan engine and assess the risk of ice accretion. The tool is comprised of an engine system thermodynamic cycle code, a compressor flow analysis code, and an ice particle melt code that has the capability of determining the rate of sublimation, melting, and evaporation through the compressor flow path, without modeling the actual ice accretion. A commercial turbofan engine which has previously experienced icing events during operation in a high altitude ice crystal environment has been tested in the Propulsion Systems Laboratory (PSL) altitude test facility at NASA Glenn Research Center. The PSL has the capability to produce a continuous ice cloud which is ingested by the engine during operation over a range of altitude conditions. The PSL test results confirmed that there was ice accretion in the engine due to ice crystal ingestion, at the same simulated altitude operating conditions as experienced previously in flight. The computational tool was utilized to help guide a portion of the PSL testing, and was used to predict ice accretion could also occur at significantly lower altitudes. The predictions were qualitatively verified by subsequent testing of the engine in the PSL. In a previous study, analysis of select PSL test data points helped to calibrate the engine icing computational tool to assess the risk of ice accretion. This current study is a continuation of that data analysis effort. The study focused on tracking the variations in wet bulb temperature and ice particle melt ratio through the engine core flow path. The results from this study have identified trends, while also identifying gaps in understanding as to how the local wet bulb temperature and melt ratio affects the risk of ice accretion and subsequent engine behavior.

Jorgenson, Philip C. E.↗

Modeling of Commercial Turbofan Engine with Ice Crystal Ingestion; Follow-On

The occurrence of ice accretion within commercial high bypass aircraft turbine engines has been reported under certain atmospheric conditions. Engine anomalies have taken place at high altitudes that have been attributed to ice crystal ingestion, partially melting, and ice accretion on the compression system components. The result was degraded engine performance, and one or more of the following: loss of thrust control (roll back), compressor surge or stall, and flameout of the combustor. As ice crystals are ingested into the fan and low pressure compression system, the increase in air temperature causes a portion of the ice crystals to melt. It is hypothesized that this allows the ice-water mixture to cover the metal surfaces of the compressor stationary components which leads to ice accretion through evaporative cooling. Ice accretion causes a blockage which subsequently results in the deterioration in performance of the compressor and engine. The focus of this research is to apply an engine icing computational tool to simulate the flow through a turbofan engine and assess the risk of ice accretion. The tool is comprised of an engine system thermodynamic cycle code, a compressor flow analysis code, and an ice particle melt code that has the capability of determining the rate of sublimation, melting, and evaporation through the compressor flow path, without modeling the actual ice accretion. A commercial turbofan engine which has previously experienced icing events during operation in a high altitude ice crystal environment has been tested in the Propulsion Systems Laboratory (PSL) altitude test facility at NASA Glenn Research Center. The PSL has the capability to produce a continuous ice cloud which is ingested by the engine during operation over a range of altitude conditions. The PSL test results confirmed that there was ice accretion in the engine due to ice crystal ingestion, at the same simulated altitude operating conditions as experienced previously in flight. The computational tool was utilized to help guide a portion of the PSL testing, and was used to predict ice accretion could also occur at significantly lower altitudes. The predictions were qualitatively verified by subsequent testing of the engine in the PSL. In a previous study, analysis of select PSL test data points helped to calibrate the engine icing computational tool to assess the risk of ice accretion. This current study is a continuation of that data analysis effort. The study focused on tracking the variations in wet bulb temperature and ice particle melt ratio through the engine core flow path. The results from this study have identified trends, while also identifying gaps in understanding as to how the local wet bulb temperature and melt ratio affects the risk of ice accretion and subsequent engine behavior.

Jorgenson, Philip C. E.↗

Modeling of a Turbofan Engine with Ice Crystal Ingestion in the NASA Propulsion System Laboratory

The main focus of this study is to apply a computational tool for the flow analysis of the turbine engine that has been tested with ice crystal ingestion in the Propulsion Systems Laboratory (PSL) at NASA Glenn Research Center. The PSL has been used to test a highly instrumented Honeywell ALF502R-5A (LF11) turbofan engine at simulated altitude operating conditions. Test data analysis with an engine cycle code and a compressor flow code was conducted to determine the values of key icing parameters, that can indicate the risk of ice accretion, which can lead to engine rollback (un-commanded loss of engine thrust). The full engine aerothermodynamic performance was modeled with the Honeywell Customer Deck specifically created for the ALF502R-5A engine. The mean-line compressor flow analysis code, which includes a code that models the state of the ice crystal, was used to model the air flow through the fan-core and low pressure compressor. The results of the compressor flow analyses included calculations of the ice-water flow rate to air flow rate ratio (IWAR), the local static wet bulb temperature, and the particle melt ratio throughout the flow field. It was found that the assumed particle size had a large effect on the particle melt ratio, and on the local wet bulb temperature. In this study the particle size was varied parametrically to produce a non-zero calculated melt ratio in the exit guide vane (EGV) region of the low pressure compressor (LPC) for the data points that experienced a growth of blockage there, and a subsequent engine called rollback (CRB). At data points where the engine experienced a CRB having the lowest wet bulb temperature of 492 degrees Rankine at the EGV trailing edge, the smallest particle size that produced a non-zero melt ratio (between 3 percent - 4 percent) was on the order of 1 micron. This value of melt ratio was utilized as the target for all other subsequent data points analyzed, while the particle size was varied from 1 micron - 9.5 microns to achieve the target melt ratio. For data points that did not experience a CRB which had static wet bulb temperatures in the EGV region below 492 degrees Rankine, a non-zero melt ratio could not be achieved even with a 1 micron ice particle size. The highest value of static wet bulb temperature for data points that experienced engine CRB was 498 degrees Rankine with a particle size of 9.5 microns. Based on this study of the LF11 engine test data, the range of static wet bulb temperature at the EGV exit for engine CRB was in the narrow range of 492 degrees Rankine - 498 degrees Rankine , while the minimum value of IWAR was 0.002. The rate of blockage growth due to ice accretion and boundary layer growth was estimated by scaling from a known blockage growth rate that was determined in a previous study. These results obtained from the LF11 engine analysis formed the basis of a unique “icing wedge.”

Turbo engine↗

Method and device for controlling heat pump

A method for controlling a heat pump is provided. A working mode of the heat pump is determined. Based on a determination that the working mode of the heat pump is a heating mode, an ambient temperature of the heat pump is determined. Based on a determination that the ambient temperature of the heat pump is higher than a first predetermined temperature, a first compressor of the heat pump is operated. Based on a determination that the ambient temperature of the heat pump is lower than the first predetermined temperature, both the first compressor and a second compressor of the heat pump are enabled to operate, in response to a two-stage thermostat. The first compressor and the second compressor are coupled in parallel. The method allows the heat pump to be suitable for a cold climate.

42 ENGINEERING↗

Process for retrofitting an industrial gas turbine engine for increased power and efficiency

A process for retrofitting an industrial gas turbine engine of a power plant where an old industrial engine with a high spool has a new low spool with a low pressure turbine that drives a low pressure compressor using exhaust gas from the high pressure turbine, and where the new low pressure compressor delivers compressed air through a new compressed air line to the high pressure compressor through a new inlet added to the high pressure compressor. The old electric generator is replaced with a new generator having around twice the electrical power production. One or more stages of vanes and blades are removed from the high pressure compressor to optimally match a pressure ratio split. Closed loop cooling of one or more new stages of vanes and blades in the high pressure turbine is added and the spent cooling air is discharged into the combustor.

Jones, Russell B.↗

Data compression system using base values and methods thereof

In some embodiments, a memory controller in a processor includes a base value cache, a compressor, and a metadata cache. The compressor is coupled to the base value cache and the metadata cache. The compressor compresses a data block using at least a base value and delta values. The compressor determines whether the size of the data block exceeds a data block threshold value. Based on the determination of whether the size of the compressed data block generated by the compressor exceeds the data block threshold value, the memory controller transfers only a set of the compressed delta values to memory for storage. A decompressor located in the lower level cache of the processor decompresses the compressed data block using the base value stored in the base value cache, metadata stored in the metadata cache and the delta values stored in memory.

Seyedzadehdelcheh, SeyedMohammad↗

Resource-aware compression

Systems, apparatuses, and methods for implementing a multi-tiered approach to cache compression are disclosed. A cache includes a cache controller, light compressor, and heavy compressor. The decision on which compressor to use for compressing cache lines is made based on certain resource availability such as cache capacity or memory bandwidth. This allows the cache to opportunistically use complex algorithms for compression while limiting the adverse effects of high decompression latency on system performance. To address the above issue, the proposed design takes advantage of the heavy compressors for effectively reducing memory bandwidth in high bandwidth memory (HBM) interfaces as long as they do not sacrifice system performance. Accordingly, the cache combines light and heavy compressors with a decision-making unit to achieve reduced off-chip memory traffic without sacrificing system performance.

97 MATHEMATICS AND COMPUTING↗

Data compression system using base values and methods thereof

In some embodiments, a memory controller in a processor includes a base value cache, a compressor, and a metadata cache. The compressor is coupled to the base value cache and the metadata cache. The compressor compresses a data block using at least a base value and delta values. The compressor determines whether the size of the data block exceeds a data block threshold value. Based on the determination of whether the size of the compressed data block generated by the compressor exceeds the data block threshold value, the memory controller transfers only a set of the compressed delta values to memory for storage. A decompressor located in the lower level cache of the processor decompresses the compressed data block using the base value stored in the base value cache, metadata stored in the metadata cache and the delta values stored in memory.

Seyedzadehdelcheh, Seyed Mohammad↗

Novel Air System for 300 kW Heavy Duty Fuel Cell

Hydrogen fuel cell powered vehicles for heavy duty trucks is a potential path for reducing heavy duty vehicle emissions in the future. The air handling system delivers the proper amount of air (oxygen) to react with fuel (hydrogen) in the fuel cell to produce power. Air delivery requires significant power and is the largest parasitic loss for a 300 kW fuel cell. Today’s systems use an electric motor to power an air compressor that supplies oxygen to the fuel cell stack. In addition to parasitic power loss, hydrogen fuel cell systems often have reliability issues associated with the air handling system. Reliability is of significant concern for heavy duty applications (especially long-haul applications). This project aims to improve both the electrical power consumption and reliability of hydrogen fuel cell air handling systems to meet the needs of heavy duty on-highway vehicle applications. The air handling is provided by a twin vortices series (TVS) compressor in addition to adding a TVS expander to recover waste heat energy back into the compressor. The final configuration includes a 600 V, 39 kW motor connected with a single shaft to the compressor and expander. This configuration reduced the total electrical power consumption from 48.6 kW to 37 kW at full load, 27 kW to 9 kW at half load and 0.44 kW to 0.22 kW at idle. The response time requirement was to be less than 2 seconds while the final demonstration yielded 0.62 sec. The study includes additional technologies including water dosing into the compressor, a recuperator and elimination of the intercooler.

Reich, Evan [Eaton Corporation, Southfield, MI (Un↗

Chapter 22: Compressed Air Evaluation Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures (September 2011 - August 2020)

Compressed-air systems are used widely throughout industry for many operations, including pneumatic tools, packaging and automation equipment, conveyors, and other industrial process operations. Compressed-air systems are defined as a group of subsystems composed of air compressors, air treatment equipment, controls, piping, pneumatic tools, pneumatically powered machinery, and process applications using compressed air. A compressed-air system has three primary functional subsystems: supply, distribution, and demand. Air compressors are the primary energy consumers in a compressed-air system and are the primary focus of this protocol. The two compressed-air energy efficiency measures specifically addressed in this protocol are: high-efficiency/variable speed drive (VSD) compressor replacing modulating, load/unload, or constant-speed compressor; compressed-air leak survey and repairs. This protocol provides direction on how to reliably verify savings from these two measures using a consistent approach for each.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OPEN2018 (continuation of GENSETS effort)

This project has demonstrated the key components and engineering principles to support a residential scale (1 to 2 kWe) recuperated Brayton cycle generator based upon a screw compressor and screw expander. This technical work is a continuation of the previously awarded ‘GENSETS’ program. The product goal has been to achieve a 40% fuel-to-electric LHV efficiency, an 80% overall CHP efficiency, emissions qualified to the California Air Resources Board standards, and at noise levels of 55 dB or less at 1 meter. Further, the product must operate with 8,000 hour service intervals and achieve a mean-time to overhaul of 90,000 hours. Lastly, and possibly most importantly, the product must meet demanding cost targets, exhibiting a factory cost well below $1,500/kWe. After extensive aerodynamic studies under the ‘GENSETS’ program, Brayton concluded that miniature turbomachinery could not achieve an efficiency consistent with the product’s system performance goal. Given compressor and turbine efficiency targets in the range of 78 to 81%, Brayton turned to the rotary screw machines. While the justification for a screw compressor over a conventional centrifugal compressor is well supported by industry experience, the high temperature expander represented the core technology advancement. To meet the extremely high efficiency goals, an all-ceramic rotary screw expander hot section was developed and has now been tested in the laboratory. This first-of-its-kind ceramic screw expander prototype was able to demonstrate aerodynamic efficiency in line with predictions. The test article was successfully run to full stress conditions so has also validated the mechanical design of such a unit. This has opened new avenues for the commercialization of high efficiency, small scale power generation. Interest in the technology has sparked several requests for alternate uses, an invitation to present at a screw machine conference, and continued interest from parties looking to develop a product in the spirit of the original ‘GENSETS’ goals.

42 ENGINEERING↗

Johns Hopkins University Stereoscopic Particle Image Velocimetry (SPIV) Test Results

Professor J. Katz at the Johns Hopkins University conducted an experimental investigation of the effect of varying the clearance over the tip of a compressor rotor in an embedded stage through a NASA funded award. The activity provided very detailed stereo Particle Image Velocimetry (PIV) measurements of the tip flow field in their optically index-matched facility. The researchers were able to measure and visualize the unsteady velocity and pressure field in the tip gap area for the first time from which they have published more than 10 Journal papers. The dataset has been used widely within NASA for internal program development. The compressor geometry is part of the NASA Low-Speed Axial Compressor (LSAC) compressor stage geometry which is publicly available. All the casing treatment geometries were published by the researchers at JHU. The PIV data has also been published in several ASME papers and presented at recent TurboExpo Conferences. Many research groups at universities and US industry would like access to this data; therefore, we would like to prepare the data package and release it to public. The data package will be announced on data.nasa.gov.

Compressor↗

Transient Optimization of a Gas Turbine Engine

Gas turbine engines are the primary power plants for modern commercial aircraft. Transients prompted by significant changes in thrust or power demand are common and unavoidable. Extreme transient scenarios such as those associated with a go-around during a landing attempt are possible and must be accounted for in the design of the engine and its controller. Engine transients tend to cause a reduction in compressor operability margin, which must be addressed by the engine control system and accounted for in the engine design to prevent events such as compressor stall/surge and combustor blow out. Transient operability concerns typically lead to compromises in the engine design that sacrifice efficiency and/or limit responsiveness. Transient operability is typically managed by logic that limits the fuel flow command. If this logic is not optimized, then the potential for valuable performance could be lost. This study presents a strategy for optimizing the transient limit logic and proposes a strategy for updating the control logic over the lifespan of the engine. The results demonstrate significant improvements in transient operability. For example, of the results at sea level static conditions demonstrated a 31% reduction in the usage of the high pressure compressor operability stack during a snap acceleration transient. Furthermore, a reinforcement learning algorithm is demonstrated to modify the transient logic as the engine degrades to minimize response time while respecting a prescribed compressor operability margin limit. A simple demonstration of the reinforcement learning algorithm resulted in a thrust response time reduction of ~11.8%.

transient↗