Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “building performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Beyond Energy Efficiency: A clustering approach to embed demand flexibility into building energy benchmarking

The intermittency of carbon-free renewables and the demand changes associated with the widespread push for electrifying the transportation and building sectors provides an opportunity for buildings to go beyond energy efficiency and push towards providing demand flexibility to the electricity grid. The duality of energy efficiency and demand flexibility is necessary for success in a sustainable and reliable energy transition. Current building energy benchmarking models are limited in their ability to integrate concepts of demand flexibility and/or utilize granular smart meter data. Thus, current benchmarking methods are focused annual energy usage and fail to incorporate how the time of use of energy consumption impacts emissions in a quickly changing energy grid. Without a more comprehensive view of energy usage and associated real-time emissions, current benchmarking methods are unlikely to realize the full decarbonization potential of buildings. New emerging data streams provide an opportunity to develop a new generation of benchmarking energy models that embed dimensions of energy efficiency, grid interactivity, and demand flexibility into their analysis. In this paper, we propose a four-step method for embedding grid interactivity and demand flexibility into building benchmarking models that utilizes emerging building and time-series electricity data streams. We first engineer features to produce a mix-type dataset that encompasses many attributes of grid-interactive and efficient buildings, and then we apply K-medoids using Gower's Distance to produce peer-group clusters. We apply the method to a case study of 306 primary and secondary schools in southern California, USA. The results show that the method effectively clusters buildings by attributes of demand flexibility and energy efficiency. The clustering results reveal patterns in inefficient building operations and demand inflexibility at the building peer group level. In conclusion, the interpretation of clusters can serve as an integrated energy efficiency and demand flexibility benchmarking model and inform performance-specific policy targeting for buildings that go beyond traditional efficiency measures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of high efficiency window air conditioner using propane under limited charge

The residential air conditioner market has a significant portion of window air conditioners (WAC). Due to the compact size and small refrigerant charge, WACs are most tolerant of flammable refrigerants. Hydrocarbon (HC) refrigerants are natural substances and have significantly better environmental impacts and lower costs than conventional refrigerants like R-410A and R-22. The paper aimed to develop a WAC prototype using propane (R-290) and verify the performance metrics in the laboratory. The key of developing the WAC using a flammable refrigerant is to control the refrigerant charge under the limit of building safety regulation with the performance meeting the Energy Star standard. To minimize the charge, compact heat exchangers were utilized. To achieve the target efficiency, we collaborated with a leading rotary compressor manufacturer to develop a compressor prototype specifically optimized for R-290, able to achieve superior energy efficiency. In addition, we conducted model-based investigations to identify further charge reduction potential. Finally, with using microchannel heat exchangers to replace the fin-and-tube condenser and evaporator, the system charge can be decreased to 150 g.

42 ENGINEERING↗

Defining and applying an electricity demand flexibility benchmarking metrics framework for grid-interactive efficient commercial buildings

Building demand flexibility (DF) research has recently gained attention. To unlock building DF as a predictable grid resource, we must establish a quantitative understanding of the resource size, performance variability, and predictability based on large empirical datasets. Researchers have proposed various sets of theoretical metrics to measure this performance. Some metrics have been applied to simulation results, but most fall short of exploring the complexities in real building applications. There are practical metrics used in individual demand response field studies but they alone cannot fulfil the job of DF benchmarking across a diverse group of buildings. The electrical grid's geographically diverse and changing nature presents challenges to comparing building DF performance measured under different conditions (i.e., benchmarking DF). To address this challenge, a novel DF benchmarking framework focused on load shedding and shifting is presented; the foundation is a set of simple, proven single-event metrics with attributes describing event conditions. These enable benchmarking and visualization in different dimensions for identifying trends that represent how these attributes influence DF. To test its feasibility and scalability, the DF framework was applied to two case studies of 11 office buildings and 121 big-box retail buildings with demand response participation data. Furthermore, these examples provided a pathway for using both building level benchmarking and aggregation to extract insights into building DF about magnitude, consistency, and influential factors. Potential applications of the framework and real-world values have been identified for grid and building stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Packaged scalable energy information systems for hotels

Purpose: Building energy information systems (EIS) are performance monitoring software, data acquisition hardware and communication systems used to store, analyze and display building energy data. Some $60bn are spent annually on wasted energy in the US buildings, and actions taken based on EIS data can enable operational energy savings of approximately 10 per cent in the US commercial sector (approximately two quads of primary energy). However, EIS adoption is low because of various technical and market challenges. This paper aims to provide technical specifications for standardized EIS packages that can help overcome barriers and accelerate scale. Design/methodology/approach: Here, a five-step approach was followed: identifying business drivers as key determinants for hotel sector-specific packages; addressing heterogeneity to develop standardized, tiered packages; determining performance metrics for key stakeholders; recommending streamlined data architecture; and developing visualization enabling insights and actions. Findings: Technical specifications for two tiers (entry and advanced) of EIS packages for hotels have been developed. EIS vendor, integrator and client organization’s facilities and IT staff have been considered as key stakeholders. Findings from six field demonstrations show benefits of cost-effectiveness, through reduced transactional, first and operational costs, scalability, by accommodating heterogeneity across the building sub-sector, simplicity, by integrating meters, gateways and software in the package and actionability in organizations, across various decision-making levels. Originality/value: Building owners and operators can use these specifications to ease procurement and installation of EIS in their facilities. EIS software vendors can use them to develop new product offerings for underserved sectors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Anisotropic spall failure of additively manufactured 316L stainless steel

The dynamic high strain rate tensile (spall) failure of additively manufactured (AM) materials is an area of great interest but much less understood than material failure under other loading regimes. The research presented here examines the effects of microstructure anisotropy in 316L stainless steel fabricated by laser powder bed fusion (LPBF) on its spall failure and properties. In this work, plate-on-plate impact experiments were performed using an 80-mm gas gun to investigate the spall behavior of AM fabricated sample discs with impact along the perpendicular and parallel orientations relative to build directions. Experiments were also performed on wrought 316L stainless steel as baseline material with uniform equiaxed grain microstructure for comparison with the AM material of same composition. The spall experiments involved free-surface velocity profiles measured using Photon Doppler Velocimetry (PDV) to capture the spall pull-back signals, combined with post-mortem analysis of the microstructure of soft-recovered impacted samples. In the case of AM samples, spall failure initiated preferentially at melt pool boundaries in both impact directions. The spall plane location and spall strength, however, were both heavily influenced by the orientation of the impact direction relative to the build direction in the AM samples. The spall behavior is also observed to be more complex in the samples impacted perpendicular to the build (through-thickness) direction, due in large part to the orientation of the microstructural features such as melt pool boundaries, laser scan tracks, and general grain morphology.

36 MATERIALS SCIENCE↗

Wireless Infrastructure for Performing Monitoring, Diagnostics, and Control HVAC and Other Energy-Using Systems in Small Commercial Buildings

This project focused on developing a low-cost wireless infrastructure for monitoring, diagnosing, and controlling building systems and equipment. End users receive information via the Internet and need only a web browser and Internet connection. The system used wireless communications for: (1) collecting data centrally on site from many wireless sensors installed on building equipment, (2) transmitting control signals to actuators and (3) transmitting data to an offsite network operations center where it is processed and made available to clients on the Web (see Figure 1). Although this wireless infrastructure can be applied to any building system, it was tested on two representative applications: (1) monitoring and diagnostics for packaged rooftop HVAC units used widely on small commercial buildings and (2) continuous diagnosis and control of scheduling errors such as lights and equipment left on during unoccupied hours. This project developed a generic infrastructure for performance monitoring, diagnostics, and control, applicable to a broad range of building systems and equipment, but targeted specifically to small to medium commercial buildings (an underserved market segment). The proposed solution is based on two wireless technologies. The first, wireless telemetry, is used for cell phones and paging and is reliable and widely available. This risk proved to be easily managed during the project. The second technology is on-site wireless communication for acquiring data from sensors and transmitting control signals. The technology must enable communication with many nodes, overcome physical obstructions, operate in environments with other electrical equipment, support operation with on-board power (instead of line power) for some applications, operate at low transmission power in license-free radio bands, and be low cost. We proposed wireless mesh networking to meet these needs. This technology is relatively new and has been applied only in research and tests. This proved to be a major challenge for the project and was ultimately abandoned in favor of a directly wired solution for collecting sensor data at the building. The primary reason for this was the relatively short ranges at which we were able to effectively place the sensor nodes from the central receiving unit. Several different mesh technologies were attempted with similar results. Two hardware devices were created during the original performance period of the project. The first device, the WEB-MC, is a master control unit that has two radios, a CPU, memory, and serves as the central communications device for the WEB-MC System (Currently called the 'BEST Wireless HVAC Maintenance System' as a tentative commercial product name). The WEB-MC communicates with the local mesh network system via one of its antennas. Communication with the mesh network enables the WEB-MC to configure the network, send/receive data from individual motes, and serves as the primary mechanism for collecting sensor data at remote locations. The second antenna enables the WEB-MC to connect to a cellular network ('Long-Haul Communications') to transfer data to and from the NorthWrite Network Operations Center (NOC). A third 'all-in-one' hardware solution was created after the project was extended (Phase 2) and additional resources were provided. The project team leveraged a project funded by the State of Washington to develop a hardware solution that integrated the functionality of the original two devices. The primary reason for this approach was to eliminate the mesh network technical difficulties that severely limited the functionality of the original hardware approach. There were five separate software developments required to deliver the functionality needed for this project. These include the Data Server (or Network Operations Center), Web Application, Diagnostic Software, WEB-MC Embedded Software, Mote Embedded Software. Each of these developments was necessarily dependent on the others. This resulted in a challenging management task - requiring high bandwidth communications among all the team members. Fortunately, the project team performed exceptionally well together and was able to work through the various challenges that this presented - for example, when one software tool required a detailed description of the output of a second tool, before that tool had been fully designed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of MPC Formulations for Building Control under Commercial Time-of-Use Tariffs

© 2019 IEEE. Most medium and large commercial buildings in the U.S. are subject to complex electricity tariffs that combine both Time-of-Use (TOU) energy and demand charges. This study analyses the performances of different economic Model Predictive Control (MPC) formulations, from the standpoints of monthly bill reduction, load shifting, and peak demand reduction. Simulations are performed on many simplified commercial building models, with multiple TOU demand charges, and under various summer conditions. Results show that compared to energy-only MPC, the traditional method for dealing with demand charges significantly reduces peak demand and owner bill, however, highlight a lack of load shifting capability. A proposed incremental approach is presented, which better balances the bill components in the objective function. In the case study presented, this method can improve monthly bill savings and increase load shifting during demand response events, while keeping a similarly low peak demand, compared to traditional MPC methods taking into account demand charges.

Cutsem, Olivier Van↗

Scaling Energy Efficient Retrofits for Small Commercial Apartment Buildings

With support from the U.S. Department of Energy’s (DOE) Building Technologies Office (BTO), the International Center for Appropriate and Sustainable Technology (ICAST) recently completed a three-year cooperative agreement to scale energy efficiency retrofits (EER) on small multifamily (MF) buildings. ICAST EER strategies ranged from low-hanging “direct install” of measures such as LED lighting, low-flow showerheads and aerators, and smart thermostats to major strategies such as HVAC replacement with high-efficiency boilers or heat pumps. As feasible, some projects also included the addition of renewable energy sources such as photo voltaic (PV) solar. When ICAST began the BTO project, it operated in two states and oversaw EER at approximately 80 MF buildings per year. With assistance from BTO, ICAST has grown significantly and now has staff in six states with MF EER projects in another seven, and performed EER on 956 MF buildings. ). ICAST was able to successfully execute this project by 1) Improving viability and efficiency of its processes, 2) Launching two new services and 3) Creating an affiliate program. For the most part, ICAST focused on a specific type of MF property: naturally occurring affordable housing (NOAH), because it is a significantly underserved market within the hard-to-serve MF market. NOAHs are typically smaller properties (5 to 64 units), owned by small organizations or individual investors looking for positive cash flow. ICAST believes the NOAH market can be successfully served with a one-stop-shop approach that makes it easy, hassle-free, and cost-effective for owners to acquire green upgrades for their property(ies). With the assistance of BTO funding, ICAST successfully used the cited EER methods and strategies to scale-up its OSS approach to service a greater number of MF housing and expand into new geographies. Additionally, support from BTO helped ICAST create self-sustaining programs which will not need to rely on on-going funding.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

PV Performance Modeling and Stakeholder Engagement (Q3 FY2020 Project Report)

The objectives of this project are as follows: 1. Reduce uncertainty in PV performance models by developing and validating new and improved models and submodes. 2. Create and manage an open source repository of modeling functions and data. 3. Build and grow the PV Performance Modeling Collaborative; and, 4. Represent the US in the IEA PVPS Task 13 Working group.

14 SOLAR ENERGY↗

PV Performance Modeling and Stakeholder Engagement (Q1 FY2021 Project Report))

The objectives of this project are as follows: 1) Reduce uncertainty in PV performance models by developing and validating new and improved models and submodes. 2) Create and manage an open source repository of modeling functions and data. 3) Build and grow the PV Performance Modeling Collaborative 4) Represent the US in the IEA PVPS Task 13 Working group.

14 SOLAR ENERGY↗

Co-Simulation of Detailed Whole Building with the Power System to Study Smart Grid Applications

Modernization of the power system in a way that ensures a sustainable energy system is arguably one of the most pressing concerns of our time. Buildings are important components in the power system. First, they are the main consumers of electricity and secondly, they do not have constant energy demand. Conventionally, electricity has been difficult to store and should be consumed as it is generated. Therefore, maintaining the demand and supply is critical in the power system. However, to reduce the complexity of power models, buildings (i.e., end-use loads) are traditionally modeled and represented as aggregated “dumb” nodes in the power system. This means we lack effective detailed whole building energy models that can support requirements and emerging technologies of the smart power grid. To gain greater insight into the relationship between building energy demand and power system performance, it is important to constitute a co-simulation framework to support detailed building energy modeling and simulation within the power system to study capabilities promised by the modern power grid. This paper discusses ongoing work at Pacific Northwest National Laboratory and presents underlying tools and framework needed to enable co-simulation of building, building energy systems and their control in the power system to study applications such as demand response, grid-based HVAC control, and deployment of buildings for ancillary services. The optimal goal is to develop an integrated modeling and simulation platform that is flexible, reusable, and scalable. Results of this work will contribute to future building and power system studies, especially those related to the integrated ‘smart grid’. Results are also expected to advance power resiliency and local (micro) scale grid studies where several building and renewable energy systems transact energy directly. This paper also reviews some applications that can be supported and studied using the framework introduced to understand their implications before they can be successfully implemented in the power system.

Makhmalbaf, Atefe↗

Energy and economic analysis of total energy systems for residential and commercial buildings

Energy and economic analyses were performed for an on-site power-plant with waste heat recovery. The results show that for any specific application there is a characteristic power conversion efficiency that minimizes fuel consumption, and that efficiencies greater than this do not significantly improve fuel consumption. This type of powerplant appears to be a reasonably attractive investment if higher fuel costs continue.

Maag, W. L.↗

Self-benchmarking Guide for Laboratory Buildings: Metrics, Benchmarks, Actions

This guide describes energy efficiency metrics and benchmarks that can be used to track the performance of and identify potential opportunities to reduce energy use in laboratory buildings. This guide is primarily intended for personnel who have responsibility for managing energy use in existing laboratory facilities - including facilities managers, energy managers, and their engineering consultants. Additionally, laboratory planners and designers may also use the metrics and benchmarks described in this guide for goal-setting in new construction or major renovation. This guide provides the following information: (1) A step-by-step outline of the benchmarking process. (2) A set of performance metrics for the whole building as well as individual systems. For each metric, the guide provides a definition, performance benchmarks, and potential actions that can be inferred from evaluating this metric. (3) A list and descriptions of the data required for computing the metrics. This guide is complemented by spreadsheet templates for data collection and for computing the benchmarking metrics. This guide builds on prior research supported by the national Laboratories for the 21st Century (Labs21) program, supported by the U.S. Department of Energy and the U.S. Environmental Protection Agency. Much of the benchmarking data are drawn from the Labs21 benchmarking database and technical guides. Additional benchmark data were obtained from engineering experts including laboratory designers and energy managers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emergency response and solutions for damaged fuel assembly handling events - Lessons learned from a 2013 fuel positioning issue

In 2013, during the refueling of a French 1300 MWe reactor, a fuel assembly (FX3599) was damaged by a fuel assembly positioning tool in the reactor vessel. The upper part of a corner rod of the fuel assembly was twisted and the top end grid was torn off. Because of the protruding fuel rod, the assembly could not be easily transferred for repair to the fuel storage pool via the transfer tube. This unexpected and rarely encountered situation was assessed jointly by EDF and AREVA NP. The chosen option was to directly perform the field service inside the reactor building in cells generally used for intermediate storage during refueling. This operation, performed by EDF and AREVA, involved removing the twisted rod and positioning it in a special-purpose canister by means of a gripper-type tool for removal (KIPCI gripper) and a gripper for holding the rod in place. The special-purpose canister was designed, ordered and supplied by a sub-supplier within one week. The operation went through 3 phases. First a preparation step in the fuel building: The stripper was disassembled and technical checks carried out to ensure correct operation. The gripper tightening force was checked in real-life conditions with the gripper suspended from auxiliary crane. The fuel rod removal was simulated several times by trained operators. Second, the equipment was installed in the reactor building. And third, the operation took place in the reactor cavity: the special-purpose canister was opened, the radioactive waste canister placed in the special-purpose canister, the twisted fuel rod was then grasped by the KIPCI gripper and removed from the fuel assembly. The twisted fuel rod was positioned above the canister and dropped into it. Once the fuel rod had been removed, the canister and fuel assembly FX3599 were transferred to the fuel building and refueling resumed. The canister containing the fuel rod is currently in interim storage in the reactor pool until appropriate action is taken for it to be shipped and eventually reprocessed. EDF has performed improvement in its handling procedures and in its handling tools to avoid a similar new event.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Energy Management Information Systems Cybersecurity Best Practices

Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.

cybersecurity↗

Energy Management Information Systems Cybersecurity Best Practices

Energy management information systems (EMIS) are a broad and rapidly evolving family of tools that monitor, analyze, and control building energy use and system performance. Critical systems are often integrated with or operate on the same networks as EMIS scope systems, necessitating stable, continuous, and secure communication. When connecting EMIS to building automation and utility control systems, there are also many physical assets that could cause harm to the building and its occupants if a malicious act or human error were introduced. It is imperative to ensure all EMIS scope systems are connected securely to the EMIS and do not open vulnerable pathways to other facility networks and operations. The Federal Energy Management Program (FEMP) promotes best practices for impactful utilization of EMIS at federal facilities. This best practice document is part of a series of fact sheets created to help accelerate the market adoption and use of EMIS in the federal sector. It provides an overview of required EMIS cybersecurity standards for compliance and authority to operate along with additional recommendations.

Cybersecurity↗