On Forced RF Generation of CW Magnetrons for SRF Accelerators

CW magnetrons, initially developed for industrial RF heaters, were suggested to power RF cavities of superconducting accelerators due to their higher efficiency and lower cost than traditionally used klystrons, IOTs or solid-state amplifiers. RF amplifiers driven by a master oscillator serve as coherent RF sources. CW magnetrons are regenerative RF generators with a huge regenerative gain. This causes regenerative instability with a large noise when a magnetron operates with the anode voltage above the threshold of self-excitation. Traditionally for stabilization of magnetrons is used injection locking by a quite small signal. Then the magnetron except the injection locked oscillations may generate noise. This may preclude use of standard CW magnetrons in some SRF accelerators. Recently we developed briefly described below a mode for forced RF generation of CW magnetrons when the magnetron startup is provided by the injected forcing signal and the regenerative noise is suppressed. The mode is most suitable for powering high Q-factor SRF cavities.

43 PARTICLE ACCELERATORS↗

Cryocooler conduction-cooled SRF cavities for compact particle accelerators

Cryocooler conduction cooling offers simple, reliable cryogenics for developing industrial SRF e-beam accelerators. Conduction-cooled SRF R&D at Fermilab: first demonstration >6.5 MV/m cw on a 650 MHz Nb 3 Sn coated cavity; prototype development and high power accelerators designs in progress. Cryocooler conduction cooling can greatly expand access to SRF: university groups, industries can embark on in house SRF R&D without needing full stack helium cryogenic systems

43 PARTICLE ACCELERATORS↗

Changes in SSL Device Efficiency and Optical Performance Under Accelerated Aging Conditions

Lighting application efficiency (LAE) describes the efficient delivery of light from the light source to the lighted task and is viewed as a new frontier—increasing energy savings with solid-state lighting (SSL) technologies. The framework for LAE that is proposed by the U.S. Department of Energy (DOE) consists of four major elements: light source efficiency, optical delivery efficiency, spectral efficiency, and intensity effectiveness. This report focuses on a sampling of the available SSL products that can be broadly defined as having modified spectral output because the method of spectra modification has a significant impact on light source efficiency and long-term optical delivery and spectral efficiencies. This report focused on the changes in light source, optical delivery, and spectral efficiencies that occur during aging of SSL devices. An accelerated stress test (AST) regiment was developed for the devices under test (DUTs) examined in this report to provide insights into how the performance of SSL devices change with aging. The AST protocols demonstrate that the SSL products discussed in this report often reduce light source efficiency to achieve different spectral characteristics. In addition, aging of the optical components (e.g., lenses, solder masks) in SSL devices can produce increased light absorption, which negatively impacts optical delivery efficiency and light source efficiency. The modified spectral outputs of the selected SSL products discussed in this report come in a variety of form factors and achieve enhanced optical performance by using a variety of methods. All of the products examined in this study use mid-power light-emitting diodes (MP-LEDs), although the number, configuration, phosphor content, and light-emitting diode (LED) pump of the MP-LEDs differ. Product MS-1 is a 60-watt (W) replacement A19 lamp with a hermetically sealed glass globe, which contains an embedded optical filter to absorb green and yellow emissions, thereby creating a “sunlike” modified spectrum. Product MS-2 is a 60-W replacement A19 lamp with 30 MP-LEDs, and it uses a violet LED pump, along with green and red phosphor emissions, to produce a “healthy” spectrum. This spectrum omits blue emissions in an effort to reduce melanopic lux. Product MS-3 is an LED module consisting of 21 MP-LEDs that use a violet LED pump, along with blue, green, and red phosphors, to produce a “sunlike” spectrum. Products MS-4 and MS-5 are both 6-inch (in) downlights that use a manual switching mechanism so that users can select application-specific correlated color temperatures before installation. Products MS-4 and MS-5 both contain two LED primaries (2,700 Kelvin [K] and 5,000 K) for spectral tuning. Product MS-4 contains 12 MP-LEDs for each LED primary, and Product MS-5 contains 10 MP-LEDs for each LED primary. This report summarizes the overall findings from up to 8,000 hours (hrs) of AST on the lamp DUTs (Products MS-1 and MS-2); up to 5,000 hrs of AST on the LED light engine DUTs (Product MS-3); and up to 7,000 hrs of AST on the downlight DUTs (Products MS-4 and MS-5). The AST procedures used in this study included a room temperature operational life (RTOL) test, an operational life test conducted at 45 degrees Celsius (°C; 45OL) test, an operational life test conducted at 75°C (75OL), a wet high-temperature operational life test performed at 65°C and 90% relative humidity (6590), and a wet high-temperature operational life test performed at 75°C and 75% relative humidity (7575). The AST procedures used for Products MS-1 and MS-2 were RTOL, 45OL, and 6590. The AST procedures used for Products MS-3, MS-4, and MS-5 were RTOL, 75OL, and 7575. During the ASTs described herein, separate populations of each product (three DUTs in each population for Products MS-1, MS-2, MS-4, and MS-5; four DUTs in each population for Product MS-3) were subjected to power cycling of 1 hr on and 1 hr off. The key findings from this study include the following. Enhanced optical performance came at the cost of reduced light source efficiency for the lamps and light engines examined in this study. The optical filter used to produce a “sunlike” spectrum for Product MS-1 reduced light source efficiency by 26%, from 113 lumens per watt (lm/W) to 85 lm/W. Products MS-2 and MS-3 that used a violet-pumped LED to achieve “healthy” and “sunlike” enhanced optical performance, respectively, suffered the largest reduction in initial light source efficiency (49 lm/W for Product MS-2 and 68 lm/W for Products MS-3) perhaps because of the use of violet LED as the optical pump. Product MS-2 also had the poorest color fidelity because of undersaturation of blues and oversaturation of greens and yellows. Chromaticity maintenance of the products in this study was generally good, with parametric failure only occurring for one product at one AST condition (i.e., Product MS-3 at 7575). The chromaticity shift for Product MS-3 in 7575 test conditions resulted from reduced emissions of the broad green and red phosphors used to mimic sunlight in the 500–750 nanometer (nm) range. As a result of these phosphor emission losses, chromaticity shifted toward the more stable violet-pumped LED and blue phosphor. Although chromaticity maintenance was acceptable for most products tested, different chromaticity shift mechanisms were observed for temperature and humidity tests compared with temperature alone for Products MS-1, MS-2, and MS-3. For Product MS-1, a relative increase in green emissions was observed with humidity, which may indicate humidity-accelerated degradation of the optical filter at green wavelengths (optical delivery efficiency reduction) or degradation of the emitters in the red region (spectral efficiency reduction). The violet-pumped products (i.e., MS-2 and MS-3) exhibited different chromaticity shift behavior in the temperature-humidity environments, with Product MS-2 shifting generally yellow because of photo-induced oxidation of the plastic globe (i.e., a reduction of optical delivery efficiency) and Product MS-3 shifting toward violet and blue emitters because of faster loss of emission from green and red phosphors (i.e., a reduction in spectral efficiency). Because of an initial drop in power consumption, the light source efficiency of downlights (Products MS-4 and MS-5) increased at RTOL throughout the test duration. The light source efficiency initially increased during 75OL until a decay in luminous flux maintenance (LFM) dominated light source efficiency, whereas the light source efficiency decreased for the entire 7575 test duration. It was found that increasing the ambient environment of an SSL device from 25°C to 75°C decreases the LFM by 2.7 to 5.5, depending on design of the SSL device. Adding humidity to the system (75OL to 7575) was found to decrease LFM by another factor of approximately 3.0. A common location of failure was identified for the downlights (Products MS-4 and MS-5) operated in the 7575 environment. This failure abruptly occurred between 3,000 to 5,000 hrs of testing on the film capacitor of the electromagnetic interference (EMI) filter near the diode bridge for 11 of the 12 downlights. It is likely that this failure was caused by a combination of the high electrical voltage across the capacitor, the location of the capacitor near the heat sources (e.g., transformers, diode bridges, power resistors), and the high stress environment of 7575. Longer test times are needed to fully understand the LFM, luminous efficacy changes, and chromaticity shifts for some of the products. Because of the high reliability, light source efficiency, and spectral tuning capabilities of LEDs, the expectations of LAE for SSL products are greatly increased over traditional lighting products. The data gathered in this report begin to provide an understanding of the tradeoffs that current SSL products undergo when optimizing the different efficiency elements of LAE. As discussed in this report, the findings from the tests conducted show that the optimization of spectral efficiency can come at the cost of initial light source efficiency. Furthermore, the introduction of violet LEDs can promote long-term optical delivery efficiency degradation, and the introduction of optical filters or new phosphors can lead to unwanted spectral efficiency changes because the ratio of phosphor emitters changes with aging. The data presented in this report also identified a common failure location in 6-in downlights. The results regarding long-term behavior of the modified spectra devices studied provide valuable information about changes to the light source, spectral, and optical delivery efficiencies as the devices age. This information can be used to improve future SSL designs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integration of High-Z Converter into Full-scale Production Target for Accelerator-based Production of 99 Mo

NorthStar Medical Technologies is planning to produce the 99Mo isotope via the photonuclear route. The Rhodotron accelerator designed by IBA will be used as an electron-beam source. The Rhodotron is an efficient recirculating accelerator, providing low energy dispersion and a low-emittance electron beam. The nominal beam power is assumed to be 120 kW at 40 MeV. In photonuclear production of 99 Mo, a high-power electron beam impinges on a helium-cooled Mo disk target. Electrons are converted into photons through the Bremsstrahlung process. Consequently, high-energy photons interact with the target nuclei, producing 99 Mo through the 100 Mo(γ, n) 99 Mo reaction. Traditionally, photonuclear production is realized using high-Z material as the electron-to-photon converter. NorthStar plans not to use a high-Z converter in the initial production target design, but it may be interested in the increased production capabilities a high-Z converter can provide. The purpose of this report is to evaluate the advantages and disadvantages of incorporating a high-Z converter into the target design.

07 ISOTOPE AND RADIATION SOURCES↗

Initial conditions for simulations of beam physics in linear induction accelerators

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the DualAxis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.

43 PARTICLE ACCELERATORS↗

SNOWMASS2021 (AF7): Sub-scale models and infrastructure for accelerator magnet development

The LHC is undoubtfully the most important instrument the HEP community has on its disposal and is widely considered an amazing technological achievement. At the core of this instrument lay accelerator magnets based on NbTi technology – a technology well developed and widely used in the commercial sector too. Yet, a decade after the accelerator started it still did not reach its design collision energy of 14 TeV and it operated for years well below it. The reason for this is simple – magnet training (even though only a subset of the magnets is mostly affected).

43 PARTICLE ACCELERATORS↗

Integrable optics design principles for beam halo suppression in accelerator rings at the intensity frontier

RadiaSoft LLC is collaborating with Fermilab to fundamentally advance the field of particle accelerator design, in order to reduce cost and technical risk for next-generation hadron accelerators, and to more rapidly advance the intensity frontier of high energy physics. The Fermilab PI is one of the originators of the theory of integrable nonlinear magnetic lattices. Fermilab is the only laboratory in the world pursuing the experimental verification of the theory. Transferring Fermilab expertise to RadiaSoft LLC will enhance US competitiveness by enabling US industry to engage in the design of future high intensity hadron rings for spallation sources, neutrino sources, muon sources, subcritical nuclear reactors and waste transmutation facilities.

43 PARTICLE ACCELERATORS↗

SRF E - Beam Accelerator for Metal Additive Manufacturing [Patent]

A system and apparatus for electron beam melting comprises a superconducting radio frequency accelerator configured to produce an electron beam, a conduction cooling system configured to cool the superconducting radio frequency accelerator, and an electron beam melting system wherein the electron beam melts power in a build chamber of the electron beam melting apparatus.

43 PARTICLE ACCELERATORS↗

Accelerator Frontier

In 2020-2022, extensive discussions and deliberations have taken place in corresponding topical working groups of the Snowmass Accelerator Frontier (AF) and in numerous joint meetings with other Frontiers, Snowmass-wide meetings, a series of Colloquium-style Agoras, cross-Frontier Forums on muon and electron-positron colliders and the collider Implementation Task Force (ITF). The outcomes of these activities are summarized in this Accelerator Frontier report.

43 PARTICLE ACCELERATORS↗

Correct Initial Conditions for Simulations of Beam Physics in Linear Induction Accelerators

Flash radiography of hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories. At Los Alamos, the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility two linear induction electron accelerators (LIAs) make the bremsstrahlung radiographic source spots for point projection radiographs from orthogonal views. A new LIA, called Scorpius, is presently under development to advance this technology. To better understand electron-beam physics in these LIAs, numerical simulations are frequently performed with the objective of improving the radiography. At Los Alamos we frequently use the TRAK ray-trace and LSP particle-in-cell (PIC) codes to simulate the injector, and the XTR and LAMDA envelope/centroid codes along with LSP to simulate transport of the accelerated beam through the LIAs. The LIA simulations need the injected beam parameters as initial conditions for calculating beam transport and stability. The determination of these initial conditions is the topic of this note.

43 PARTICLE ACCELERATORS↗

MQXFA Series Magnet Production Specification: US HL-LHC Accelerator Upgrade Project

The purpose of this document is to define the specifications for the structure fabrication and assembly of MQXFA series magnets to be used by the US High-Luminosity LHC Accelerator Upgrade Project (AUP). Magnets fabricated according to these specifications are expected to allow MQXFA magnets to meet the MQXFA Functional Requirements Specification. These specifications for the fabrication of MQXFA series magnets are based on the R&D performed by the US LHC Accelerator Research Program (LARP) and the development performed by AUP, in collaboration with CERN, through fabrication and test of pre-series coils and magnets.

43 PARTICLE ACCELERATORS↗

The LANSCE experimental program: accelerator requirements

The LANSCE accelerator complex exploits a flexible, high power 800 MeV proton linear accelerator to enable a broad swath of experimental work supporting multiple scientific programs. The beam requirements for these programs are diverse and change over time. The purpose of this document is to record, at a high level, the experimental requirements driving the beam delivery requirements for each experimental facility at LANSCE. Revision 0 serves to baseline the current set of experiments, and we expect to revise the document on an as-needed basis when either the experimental requirements change or are found to require a more complete definition.

43 PARTICLE ACCELERATORS↗

Accelerators for Electroweak Physics and Higgs Boson Studies

We discuss the goals, the designs, the state of technical readiness, and the critical R&D needs of the accelerators that are currently under discussion as Higgs and electroweak factories. We also address the respective staging options enabling future energy-frontier colliders. The accelerators covered are based on many different techniques and approaches. They include several circular colliders, various linear colliders, colliders based on energy recovery linacs (ERLs), ERL-ring combinations, as well as γγ colliders. The linear colliders proposed consist of options for the International Linear Collider (ILC), for the Compact Linear Collider (CLIC), for the Cold Copper Collider (C 3 ), and for the more recent Higgs-Energy Lepton Collider (HELEN). ERLs are key components of the Recycling Linear e + e - Collider (ReLiC),of the Energy Recovery Linear Collider (ERLC), and of the Circular Energy Recovery Collider (CERC). Among the more conventional ring colliders the following proposals are featured: the Future Circular Collider (FCC-ee), the Circular Electron Positron Collider (CEPC), the Electron Positron Circular Collider at Fermilab (EPCCF), and the Large Electron Positron collider #3 (LEP-3). In addition, we consider the X-ray FEL based gamma- gamma Collider Higgs Factory (XCC) and the High-Energy High-Luminosity γ-γ collider (HE&HL γγ). Finally, a Higgs factory based on a circular muon collider is mentioned for completeness.

43 PARTICLE ACCELERATORS↗

Business models to assure availability of advanced superconductors for the accelerator sector and promote stewardship of superconducting magnet technology for the US economy

Stakeholders representing concerns of national and global leadership, industries that use superconducting magnets in products, manufacturers of superconducting wires and tapes that supply to industries, and innovation generators from small businesses and universities came together to address stewardship of superconducting magnet technology and assurance of supply of advanced superconductors to the accelerator sector. This report outlines potential public-private partnerships that develop and enhance domestic capabilities to meet the needs of science facilities in the accelerator systems sector and in the broader commercial ecosystem.

43 PARTICLE ACCELERATORS↗

Final Technical Report: Innovative Magnetron Power Sources for Superconducting RF (SRF) Accelerators

In this project, MUONS is designing and building custom magnetrons at Richardson Electronics (RELL) to test the predictions of the models and make improvements to the designs to match the needs of NP SRF accelerators and their life-cycle costs. To increase lifetime, the filament temperature is controlled by a feedback circuit that includes a model of back streaming of electrons. The gain of the magnetron is optimized by the design of an input port. A permanent magnet design with trim coil for amplitude adjustment reduces energy consumption. Moving the construction of the magnetron from prototype to manufacturing includes the utilization of RELL processes and designs. To the extent that outgassing of materials influences the lifetime of the magnetron, methods for minimizing outgassing was explored. Further experimentation of the potential of sub-critical voltage operation continues to be explored. The commercialization goal of the project will be naturally achieved as RELL already has world-wide marketing, sales, and support to exploit the assembly-line capabilities generated by this project to enable magnetron technologies for NP accelerators.

43 PARTICLE ACCELERATORS↗

Cathode Side-emission Mitigation for Linear Induction Accelerators

Linear induction accelerators (LIAs) are one of the main technologies used in creating flash x-rays used for diagnosing hydrodynamic experiments. The quality of the data produced in these experiments is dependent on the dose of x-rays generated via bremsstrahlung radiation. There are several electron beam quantities that effect the amount of dose extracted from the bremsstrahlung radiation, such as beam instabilities, corkscrew motion, and beam emittance. Injector design is key in delivering well-behaved electron beams to the accelerator, and design choices include components such as anode-cathode (AK) gap dimensions based on required voltage and current, shroud shaping, and cathode type and composition. Thermionic cathodes have shown reliable performance in electron emission, however, if enough of the cathode side is subject to high-enough electric field values, electrons can be emitted. This issue is more likely to happen when the cathode is treated with materials that have lower work functions, which is common for cathodes used in LIAs. These extra electrons can work their way through the rest of the beam, inducing high non-linearities in phase space which can increase the emittance of this beam. In this paper we outline conducted trade-space studies where we examined different shaping parameters of the cathode shroud design to decrease the effect side electrons may have on the beam emittance. Particle trajectories are determined by electric potential contours across the face of the cathode shroud component, and so we hypothesize that the proper shaping of the cathode-shroud interface can tune the electric field to mitigate the effect of side electrons. Electron beam transport is simulated down the length of the injector and the beam quality is diagnosed by studying the emittance as a function of position. Acceptable emittance increase is recorded and noted to meet radiographic requirements.