Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “aberrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Atomic-resolution visualization and doping effects of complex structures in intercalated bilayer graphene

Molecules intercalating two-dimensional materials form complex structures that have been characterized primarily by spatially averaged techniques. In this work, we use aberration-corrected scanning transmission electron microscopy and density-functional-theory (DFT) calculations to study the atomic structure of bilayer graphene (BLG) and few-layer graphene (FLG) intercalated with FeC l 3 . In BLG, we discover two distinct intercalated structures that we identify as monolayer FeC l 3 and monolayer FeC l 2 . The two structures are separated by atomically sharp boundaries and induce large free-carrier densities on the order of 10 13 c m - 2 in the graphene layers. In FLG, we observe multiple FeC l 3 layers stacked in a variety of possible configurations with respect to one another. Lastly, we find that the microscope's electron beam can convert the FeC l 3 monolayer into FeOCl monolayers in a rectangular lattice. These results reveal the need for a combination of atomically resolved microscopy, spectroscopy, and DFT calculations to identify intercalated structures and study their properties.

36 MATERIALS SCIENCE↗

Structure of the (110) Ln ScO 3 ( Ln =Gd,Tb,Dy) surfaces

The surface reconstruction on the (110) surface of LnScO 3 (Ln=Gd,Tb,Dy) has been investigated using x-ray photoelectron spectroscopy, atomic force microscopy, and transmission electron diffraction coupled with higher-level density-functional theory methods. The experimental techniques generate constraints on the surface chemistry and structure that are used to inform the theoretical comparison of a number of potential surface structures. The resulting structure is then compared to experimental aberration-corrected transmission electron microscopy results using multislice simulation. The surfaces of both single-crystalline substrates and hydrosauna synthesized nanoparticles exhibit a Sc-rich double layer with a Sc 3 O 4 termination.

36 MATERIALS SCIENCE↗

ScO x rich surface terminations on lanthanide scandate nanoparticles

We report that the lanthanide scandate materials are widely used substrates for thin film growth and the potential applications of the LnScO 3 materials continue to grow with the recent ability to synthesize them as cuboidal faceted nanoparticles. A comprehensive understanding of the surface structure and chemistry of these oxides is essential for their informed application, either as single crystal or high surface area nanoparticle substrates. Here the {100} pseudocubic surfaces of LnScO 3 (Ln = La, Nd, Sm, Gd) nanoparticles were examined with aberration-corrected electron microscopy and higher-level density functional theory to reveal ScO x rich terminations across all investigated surfaces. Mixed terminations of single and double layer nature were observed, indicating the presence of multiple domains at the surface and introducing the possibility of synthetically controlling the surface reconstruction in the future.

36 MATERIALS SCIENCE↗

Functional analysis of cellulose and xyloglucan in the walls of stomatal guard cells of Arabidopsis thaliana

Here, stomatal guard cells are pairs of specialized epidermal cells that control water and CO 2 exchange between the plant and the environment. To fulfill the functions of stomatal opening and closure that are driven by changes in turgor pressure, guard cell walls must be both strong and flexible, but how the structure and dynamics of guard cell walls enable stomatal function remains poorly understood. To address this question, we applied cell biological and genetic analyses to investigate guard cell walls and their relationship to stomatal function in Arabidopsis ( Arabidopsis thaliana ). Using live-cell spinning disk confocal microscopy, we measured the motility of cellulose synthase (CESA)-containing complexes labeled by green fluorescent protein (GFP)-CESA3 and observed a reduced proportion of GFP-CESA3 particles colocalizing with microtubules upon stomatal closure. Imaging cellulose organization in guard cells revealed a relatively uniform distribution of cellulose in the open state and a more fibrillar pattern in the closed state, indicating that cellulose microfibrils undergo dynamic reorganization during stomatal movements. In cesa3 je5 mutants defective in cellulose synthesis and xxt1 xxt2 mutants lacking the hemicellulose xyloglucan, stomatal apertures, changes in guard cell length, and cellulose reorganization were aberrant during fusicoccin-induced stomatal opening or abscisic acid-induced stomatal closure, indicating that sufficient cellulose and xyloglucan are required for normal guard cell dynamics. Together, these results provide new insights into how guard cell walls allow stomata to function as responsive mediators of gas exchange at the plant surface.

59 BASIC BIOLOGICAL SCIENCES↗

Xyloglucan Deficiency Disrupts Microtubule Stability and Cellulose Biosynthesis in Arabidopsis, Altering Cell Growth and Morphogenesis

Here, xyloglucan constitutes most of the hemicellulose in eudicot primary cell walls and functions in cell wall structure and mechanics. Although Arabidopsis ( Arabidopsis thaliana ) xxt1 xxt2 mutants lacking detectable xyloglucan are viable, they display growth defects that are suggestive of alterations in wall integrity. To probe the mechanisms underlying these defects, we analyzed cellulose arrangement, microtubule patterning and dynamics, microtubule- and wall-integrity-related gene expression, and cellulose biosynthesis in xxt1 xxt2 plants. We found that cellulose is highly aligned in xxt1 xxt2 cell walls, that its three-dimensional distribution is altered, and that microtubule patterning and stability are aberrant in etiolated xxt1 xxt2 hypocotyls. We also found that the expression levels of microtubule-associated genes, such as MAP70-5 and CLASP , and receptor genes, such as HERK1 and WAK1 , were changed in xxt1 xxt2 plants and that cellulose synthase motility is reduced in xxt1 xxt2 cells, corresponding with a reduction in cellulose content. Our results indicate that loss of xyloglucan affects both the stability of the microtubule cytoskeleton and the production and patterning of cellulose in primary cell walls. These findings establish, to our knowledge, new links between wall integrity, cytoskeletal dynamics, and wall synthesis in the regulation of plant morphogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Ptychographic X-ray speckle tracking with multi-layer Laue lens systems

The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilize their capability for imaging and probing biological cells, nano-devices and functional matter on the nanometre scale with chemical sensitivity. Hard X-rays are ideal for high-resolution imaging and spectroscopic applications owing to their short wavelength, high penetrating power and chemical sensitivity. The penetrating power that makes X-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques have enabled the fabrication of a series of highly focusing X-ray lenses, known as wedged multi-layer Laue lenses. Improvements to the lens design and fabrication technique demand an accurate, robust, in situ and at-wavelength characterization method. To this end, a modified form of the speckle tracking wavefront metrology method has been developed. The ptychographic X-ray speckle tracking method is capable of operating with highly divergent wavefields. A useful by-product of this method is that it also provides high-resolution and aberration-free projection images of extended specimens. Three separate experiments using this method are reported, where the ray path angles have been resolved to within 4 nrad with an imaging resolution of 45 nm (full period). This method does not require a high degree of coherence, making it suitable for laboratory-based X-ray sources. Likewise, it is robust to errors in the registered sample positions, making it suitable for X-ray free-electron laser facilities, where beam-pointing fluctuations can be problematic for wavefront metrology.

36 MATERIALS SCIENCE↗

The linear phase correction of modulation of intensity emerging from zero effort (MIEZE) with magnetic Wollaston prisms

This study proposes the use of two magnetic Wollaston prisms (MWPs) to correct for the linear Larmor phase aberration of modulation of intensity emerging from zero effort (MIEZE), introduced by the transverse size of the sample. With this approach, the contrast of the intensity modulation can be maximized at any scattering angle of interest such that the same contrast as the direct transmission geometry can be fully recovered. The optimum magnetic fields required for the MWPs depend only on the scattering angle and the frequencies of the radio-frequency flippers, and they are independent of the neutron wavelength and beam divergence, which makes the approach suitable for both pulsed and continuous neutron sources.

36 MATERIALS SCIENCE↗

Hard X-ray polarizer to enable simultaneous three-dimensional nanoscale imaging of magnetic structure and lattice strain

Recent progress in the development of dichroic Bragg coherent diffractive imaging, a new technique for simultaneous three-dimensional imaging of strain and magnetization at the nanoscale, is reported. This progress includes the installation of a diamond X-ray phase retarder at beamline 34-ID-C of the Advanced Photon Source. Here, the performance of the phase retarder for tuning X-ray polarization is demonstrated with temperature-dependent X-ray magnetic circular dichroism measurements on a gadolinium foil in transmission and on a Gd 5 Si 2 Ge 2 crystal in diffraction geometry with a partially coherent, focused X-ray beam. Feasibility tests for dichroic Bragg coherent diffractive imaging are presented. These tests include (1) using conventional Bragg coherent diffractive imaging to determine whether the phase retarder introduces aberrations using a nonmagnetic gold nanocrystal as a control sample, and (2) collecting coherent diffraction patterns of a magnetic Gd 5 Si 2 Ge 2 nanocrystal with left- and right-circularly polarized X-rays. Future applications of dichroic Bragg coherent diffractive imaging for the correlation of strain and lattice defects with magnetic ordering and inhomogeneities are considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diaboloidal mirrors: algebraic solution and surface shape approximations

A new type of optical element that can focus a cylindrical wave to a point focus (or vice versa) is analytically described. Such waves are, for example, produced in a beamline where light is collimated in one direction and then doubly focused by a single optic. A classical example in X-ray optics is the collimated two-crystal monochromator, with toroidal mirror refocusing. The element here replaces the toroid, and in such a system provides completely aberration free, point-to-point imaging of rays from the on-axis source point. We present an analytic solution for the mirror shape in its laboratory coordinate system with zero slope at the centre, and approximate solutions, based on bending an oblique circular cone and a bent right circular cylinder, that may facilitate fabrication and metrology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser heating system at the Extreme Conditions Beamline, P02.2, $\mathrm{PETRA III}$

A laser heating system for samples confined in diamond anvil cells paired with in situ X-ray diffraction measurements at the Extreme Conditions Beamline of PETRA III is presented. The system features two independent laser configurations (on-axis and off-axis of the X-ray path) allowing for a broad range of experiments using different designs of diamond anvil cells. The power of the continuous laser source can be modulated for use in various pulsed laser heating or flash heating applications. An example of such an application is illustrated here on the melting curve of iron at megabar pressures. The optical path of the spectroradiometry measurements is simulated with ray-tracing methods in order to assess the level of present aberrations in the system and the results are compared with other systems, that are using simpler lens optics. Based on the ray-tracing the choice of the first achromatic lens and other aspects for accurate temperature measurements are evaluated.

47 OTHER INSTRUMENTATION↗

Data-driven modeling and control of an X-ray bimorph adaptive mirror

Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated. This approach approximates the non-linear system dynamics with a discrete-time model using random mirror shapes and interferometric measurements as training data. For mirrors of this type, prior states and voltage inputs affect the shape-change trajectory, and therefore must be included in the model. Without the need for assumed physical models of the mirror's behavior, the generality of the neural network structure accommodates drift, creep and hysteresis, and enables a control algorithm that achieves shape control and stability below 2 nm RMS. Using a prototype mirror and ex situ metrology, it is shown that the accuracy of our trained model enables open-loop shape control across a diverse set of states and that the control algorithm achieves shape error magnitudes that fall within diffraction-limited performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Off-axis representation of hyperbolic mirror shapes for X-ray beamlines

Mirror-centered, closed-form expressions for hyperbolic surfaces used in X-ray beamlines have been derived. Hyperbolic mirrors create a virtual focus or source point and can be used to lengthen or shorten the effective focal distance of a compound optical system. The derivations here express off-axis segments of a hyperbolic surface in terms of the real and virtual focal distances and the incident glancing angle at the center of the mirror. Conventional mathematical expressions of hyperbolic shapes describe the surfaces in Cartesian or polar coordinates centered on an axis of symmetry, necessitating cumbersome rotation and translation to mirror-centered coordinates. The representation presented here, with zero slope and the origin at the central point, is most convenient for modeling, metrology, aberration correction, and general surface analysis of off-axis configurations. The direct derivation avoids the need for nested coordinate transforms. A series expansion provides a helpful approximation; the coefficients of the implicit equation are also provided.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resonant inelastic X-ray scattering endstation at the 1C beamline of Pohang Light Source II

An endstation for resonant inelastic X-ray scattering (RIXS), dedicated to operations in the hard X-ray regime, has been constructed at the 1C beamline of Pohang Light Source II. At the Ir L 3 -edge, a total energy resolution of 34.2 meV was achieved, close to the theoretical estimation of 34.0 meV, which considers factors such as the incident energy bandpass, intrinsic analyzer resolution, geometrical broadening of the spectrometer, finite beam-size effect and Johann aberration. The performance of the RIXS instrument is demonstrated by measuring the RIXS spectra of Sr 2 IrO 4 . The endstation can be easily reconfigured to measure energy-integrated intensities with very low background for diffuse scattering and diffraction experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray optics for the cavity-based X-ray free-electron laser

A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.

47 OTHER INSTRUMENTATION↗

Controlling cantilevered adaptive X-ray mirrors

Modeling the behavior of a prototype cantilevered X-ray adaptive mirror (held from one end) demonstrates its potential for use on high-performance X-ray beamlines. Similar adaptive mirrors are used on X-ray beamlines to compensate optical aberrations, control wavefronts and tune mirror focal distances at will. Controlled by 1D arrays of piezoceramic actuators, these glancing-incidence mirrors can provide nanometre-scale surface shape adjustment capabilities. However, significant engineering challenges remain for mounting them with low distortion and low environmental sensitivity. Finite-element analysis is used to predict the micron-scale full actuation surface shape from each channel and then linear modeling is applied to investigate the mirrors' ability to reach target profiles. Using either uniform or arbitrary spatial weighting, actuator voltages are optimized using a Moore–Penrose matrix inverse, or pseudoinverse, revealing a spatial dependence on the shape fitting with increasing fidelity farther from the mount.

47 OTHER INSTRUMENTATION↗

Dispersive X-ray absorption spectroscopy using independent grazing-incidence focusing and convexly bent Bragg-crystal dispersing optics

We present a modular instrument for dispersive X-ray absorption spectroscopy (DXAS) developed for the Advanced Spectroscopy Beamline at Sector 25 of the Advanced Photon Source. The setup employs a double-multilayer monochromator to provide X-rays with a broad energy bandwidth, Kirkpatrick–Baez mirrors for focusing, a convexly bent Bragg-crystal polychromator for energy dispersion, and a pixel-array detector to resolve all X-ray energies and collect their intensity simultaneously, thereby enabling acquisition of a full X-ray absorption spectrum in a single shot. The use of separate optics for X-ray focusing and energy dispersion provides high spatial resolution and avoids chromatic aberrations inherent in focusing bent-crystal optics, and a modular design makes implementation of the technique at other beamlines possible without requiring modifications to the upstream beamline configurations. Theoretical calculations are performed to determine optimal instrument operating parameters and demonstrate that an energy resolution better than the K-edge core-hole lifetime broadening can be maintained while providing a sufficient bandwidth for X-ray absorption near-edge structure spectroscopy through the full operating range of 5–11 keV. Additionally, instrument design, data analysis methods, and initial DXAS results on lithium–manganese–nickel oxide laminates are presented.

47 OTHER INSTRUMENTATION↗