Thermal design and experiment thermal integration of the Long Duration Exposure Facility

The Long Duration Exposure Facility (LDEF) is a large (14 feet diameter by 30 feet long) Shuttle transported, reusable spacecraft. The LDEF can accommodate up to 13,000 pounds of experiments mounted in 86 standard trays. This paper describes the philosophy and approach used for the passive thermal design of the LDEF. Also discussed are the standardized guidelines and techniques used in the thermal design and integration of approximately 50 different thermally passive experiments. A technique for reducing multinode thermal models of experiments to 2 nodes is also presented. This approach allows the efficient thermal integration of large numbers of experiments with the LDEF spacecraft.

Greene, R. F., Jr.↗

Microwave and hard X-ray observations of a solar flare with a time resolution better than 100 ms

Simultaneous microwave and X-ray observations are presented for a solar flare detected on 1980 May 8 starting at 1937 UT. The X-ray observations were made with the Hard X-ray Burst Spectrometer on the Solar Maximum Mission and covered the energy range from 28-490 keV with a time resolution of 10 ms. The microwave observations were made with the 5 and 45 foot antennas at the Itapetinga Radio Obervatory at frequencies of 7 and 22 GHz, with time resolutions of 100 ms and 1 ms respectively. Detailed correlation analysis of the different time profiles of the event show that the major impulsive in the X-ray flux preceded the corresponding microwave peaks at 22 GHz by about 240 ms. For this particular burst the 22 GHz peaks preceded the 7 GHz by about 1.5s. Observed delays of the microwave peaks are too large for a simple electron beam model but they can be reconciled with the speeds of shock waves in a thermal model. Previously announced in STAR as N82-30215

Kaufmann, P.↗

Curie isotherm surfaces inferred from high-altitude magnetic anomaly data

Two-dimensional Curie depth models along two sections across the western United States are derived using an equivalent layer magnetization model derived from Magsat data, and the results are used to constrain finite element thermal models developed by Mayhew and Majer (1980). Regional heat flow variations predicted by the models compare favorably with those inferred from direct measurements. The methodology is applied to upward-continued aeromagnetic data, and the results are found to be in good agreement with previous Curie depth estimates and average measured heat flow.

Mayhew, M. A.↗

Steps toward 8m honeycomb mirrors. VIII - Design and demonstration of a system of thermal control

Directed jets of ambient temperature air are proposed for the maintenance of low internal temperature gradients and conformity with ambient temperatures in honeycomb-structure borosilicate glass telescope mirrors. The use of greater airflow on thicker sections, to match cooling rates, and the cooling or heating of the internal, back, and edge surfaces of the mirror at the same rate established by convection on the front surface, have been tested on a full scale glass thermal model of a single honeycomb cell from an 8-m diameter mirror. The internal thermal gradient (less than 0.1 C) and ambient-temperature-change lag (less than 0.24 C) ensure minimum image degradation.

Cheng, A. Y. S.↗

Flight motor set 360L007 (STS-33R)

Flight motor set 360L007 was launched as part of NASA space shuttle mission STS-33R. As with all previous redesigned solid rocket motor launches, overall motor performance was excellent. There were no debris concerns for either motor. Both motors exhibited unbonds on one factory joint weatherseal. All ballistics contract end item specification parameters were verified, with the exception of ignition interval and rise rates. Ignition interval and rise rates could not be verified due to the elimination of developmental flight instrumentation from fourth flight and subsequent, but the low sample rate data that were available showed nominal propulsion performance. All ballistic and mass property parameters closely matched the predicted values and were well within the required contract end item specification levels that could be assessed. All 108 Ground Environment Instrumentation (GEI) measurements performed properly throughout the prelaunch phase. Evaluation of the GEI measurements again verified thermal model analysis data and showed agreement with predicted environmental effects. No launch commit criteria thermal violations occurred. All joint heaters operated normally, but a high voltage reading was noted on the left hand aft heater, which was immediately determined to be a voltage sensor error and not a heater anomaly due to no current increase. Postflight inspection again verified superior performance of the insulation, phenolics, metal parts, and seals. Postflight evaluation indicated both nozzles performed as expected during flight. All combustion gas was contained by insulation in the field and case-to-nozzle joints.

Garecht, Diane↗

Thermal analysis and test of SUNLITE reference cavity for laser frequency stabilization

SUNLITE is a space-based experiment which uses a reference cavity to provide a stable frequency reference for a terahertz laser oscillator. Thermal stability of the cavity is a key factor in attaining a stable narrow-linewidth laser beam. This paper describes the thermal stability requirements on the cavity design and detailed thermal analysis performed, as well as thermal testing that was performed on a prototype. Analytical thermal models were correlated to the test data and additional modeling of the current design is presented. Suggestions for improving similar high-precision thermal tests are given.

Amundsen, R. M.↗

xEMU Spacesuit Boot Lunar South Pole Thermal Vacuum Testing

The Exploration Extravehicular Mobility Unit (xEMU) spacesuit lunar boot was evaluated in the Jet Propulsion Lab (JPL) CITADEL thermal vacuum chamber at lunar South Pole conditions. The JPL CITADEL chamber provides a radiation environment and contact plate temperature of 48K, simulating the temperature of a lunar Permanently Shadowed Region (PSR) at the South Pole of the Moon. The main objectives of the test series were: to evaluate the risk lunar PSRs pose to advanced spacesuit boots, validate the xEMU lunar boot thermal model, and develop a test methodology to evaluate lunar spacesuit boots. To simulate the thermal effects of a crewmember’s foot inside the boot, a thermal manikin foot was developed to inject heat into the spacesuit boot. Thermal data was collected through a variety of sensors including thermocouples, thermistors, heat flux sensors, and infrared cameras. A test matrix was developed to investigate the variables of foot contact force, simulated skin temperature, external contact plate temperature, and ventilation flowrate. The JPL CITADEL chamber includes a loadlock (airlock) that afforded the ability to simulate the transition of the boot from a thermally neutral IVA condition to a cold EVA condition within seconds. This paper will document the test design, test objectives, success criteria, test support equipment, spacesuit boot to chamber interfaces, and configuration of the test article. Additionally, this paper will document the high-level results of the testing. More detailed test results will be presented in a different paper.

TVAC↗

Projection-Based Reduced Order Modeling for Spacecraft Thermal Analysis

This paper presents a mathematically rigorous, subspace projection-based reduced order modeling (ROM) methodology and an integrated framework to automatically generate reduced order models for spacecraft thermal analysis. Two key steps in the reduced order modeling procedure are described: (1) the acquisition of a full-scale spacecraft model in the ordinary differential equation (ODE) and differential algebraic equation (DAE) form to resolve its dynamic thermal behavior; and (2) the ROM to markedly reduce the dimension of the full-scale model. Specifically, proper orthogonal decomposition (POD) in conjunction with discrete empirical interpolation method (DEIM) and trajectory piece-wise linear (TPWL) methods are developed to address the strong nonlinear thermal effects due to coupled conductive and radiative heat transfer in the spacecraft environment. Case studies using NASA-relevant satellite models are undertaken to verify the capability and to assess the computational performance of the ROM technique in terms of speed-up and error relative to the full-scale model. ROM exhibits excellent agreement in spatiotemporal thermal profiles (<0.5% relative error in pertinent time scales) along with salient computational acceleration (up to two orders of magnitude speed-up) over the full-scale analysis. These findings establish the feasibility of ROM to perform rational and computationally affordable thermal analysis, develop reliable thermal control strategies for spacecraft, and greatly reduce the development cycle times and costs.

0000↗

Thermal Cycling for Development of Hybrid Fuel for a Notional Mars Ascent Vehicle

A Mars Ascent Vehicle (MAV) would be a critical part of a potential Mars sample return campaign. As currently envisioned, the MAV would launch samples from Mars into Mars orbit. Challenging requirements would be placed on a MAV as it would need to be able to survive in the harsh Martian environment which can get as cold as -120°C in the winter. At these cold temperatures, survival heating could be necessary to keep the MAV within the allowable flight temperature range. Estimates for survival heating power show that a fuel capable of operating at low temperature would significantly reduce the total required energy of the MAV. This has led to consideration of a hybrid propulsion system due to its anticipated low temperature capability. A new wax-based fuel, SP7, has been developed for a notional MAV mission. Thermal modeling of the fuel in the Mars environment was completed in order to estimate the temperature response of the fuel during Mars diurnal temperature cycling. Preliminary thermal testing was conducted to determine the max temperature range, radial gradient, and ramp rate the fuel could tolerate without cracking. The modeling and preliminary testing was used to develop a comprehensive, 100-day thermal cycling campaign. A total of 200 cycles are planned that are representative of 200 Martian diurnal cycles, roughly one-third of a Martian year. After 150 cycles, the fuel samples show no signs of cracking that would jeopardize the rocket’s performance. Though not yet complete, this testing is showing that SP7 has the potential to successfully be used on a MAV mission.

Farias, Edgardo↗

Intumescent coating modeling

A thermal response mathematical model for an intumescent coating system is developed. The model predicts indepth temperature profiles of the solid as a function of the fundamental kinetic, mass, and heat-transfer properties of the original coating system. In the model, swelling is based on an empirical function of the paint's weight loss. The model is used to describe the effectiveness of the coating for thermal protection. Using the thermal response time at the backface of the material as a criterion, a sensitivity analysis is made with respect to variation in individual properties, such as total expansion, to provide a guide for designing improved intumescing agents. The sensitivity analysis shows that total expansion and rate of expansion, along with other material properties, are important parameters for providing thermal protection. Finally, backface temperature histories are predicted and compared to experimental data obtained from a representative fire environment. Predicted temperatures agree within a maximum error of plus or minus 20%.

Cagliostro, D. E.↗

Identifying high-impact and high-uncertainty parameters in MiniFuel model predictions

The MiniFuel irradiation platform at Oak Ridge National Laboratory's High Flux Isotope Reactor (HFIR) is a flexible, high-throughput separate effects test capability. Finite element thermal models are relied upon to design MiniFuel experiments and to achieve experimental objectives. Recent reports show good agreement in the model prediction of target fuel temperatures, but as the capability of the experiments is extended to higher temperatures, the uncertainty in the model predictions must be quantified. To that end, high-impact, high-uncertainty parameters that contribute the most uncertainty to the model are identified. The uncertainty quantification was accomplished through a series of screening and sensitivity analyses. The first analysis utilizes the method of Morris to perform a computationally efficient preliminary screening that considers uncertainty in a large number of the model inputs. The most important parameters identified in the Morris screening study were then considered in a Sobol sensitivity analysis that more robustly ranks and quantifies the uncertainty associated with each parameter. From these analyses, it was determined that thermal contact conductance between components is the parameter that contributes the highest uncertainty. The estimated uncertainty of the MiniFuel model fuel temperature predictions is ±80 °C in the removable beryllium and ±40 °C in the vertical experiment facilities. In conclusion, the framework established by the series of sensitivity analyses presented herein could easily be adapted to fit the needs of accelerated fuel qualification processes.

Fuel, Irradiation↗

Modeling the Martian seasonal CO2 cycle. I - Fitting the Viking Lander pressure curves. II - Interannual variability

The present diurnal and seasonal thermal model for Mars, in which surface CO2 frost condensation and sublimation are determined by the net effects of radiation, latent heat, and heat conduction in subsurface soil layers, in order to simulate seasonal exchanges of CO2 between the polar caps and atmosphere, successfully reproduces the measured pressured variations at the Viking Lander 1 site. In the second part of this work, the year-to-year differences between measured surface pressures at Viking sites as a function of season are used as upper limits on the potential magnitudes of interannual variations in the Martian atmosphere's mass. Simulations indicate that the dust layers deposited onto the condensing north seasonal polar cap during dust storms can darken seasonal frost deposits upon their springtime uncovering, while having little effect on seasonal pressure variations.

Wood, Stephen E.↗

Micromechanical Modeling of the Thermal Expansion of Graphite/copper Composites with Nonuniform Microstructure

Two micromechanical models were developed to investigate the thermal expansion of graphite/copper (Gr/Cu) composites. The models incorporate the effects of temperature-dependent material properties, matrix inelasticity, initial residual stresses due to processing history, and nonuniform fiber distribution. The first model is based on the multiple concentric cylinder geometry, with each cylinder treated as a two-phase composite with a characteristic fiber volume fractions. By altering the fiber volume fraction of the individual cylinders, unidirectional composites with radially nonuniform fiber distributions can be investigated using this model. The second model is based on the inelastic lamination theory. By varying the fiber content in the individual laminae, composites with nonuniform fiber distribution in the thickness direction can be investigated. In both models, the properties of the individual regions (cylinders or laminae) are calculated using the method of cells micromechanical model. Classical incremental plasticity theory is used to model the inelastic response of the copper matrix at the microlevel. The models were used to characterize the effects of nonuniform fiber distribution on the thermal expansion of Gr/Cu. These effects were compared to the effects of matrix plasticity, choice of stress-free temperature, and slight fiber misalignment. It was found that the radially nonuniform fiber distribution has little effect on the thermal expansion of Gr/Cu but could become significant for composites with large fiber-matrix transverse CTE and Young's modulus mismatch. The effect of nonuniform fiber distribution in the through-thickness direction of a laminate was more significant, but only approached that of the stress-free temperature for the most extreme cases that include large amounts of bending. Subsequent comparison with experimental thermal expansion data indicated the need for more accurate characterization of the graphite fiber thermomechanical properties. Correlation with cyclic data revealed the presence of a mechanism not considered in the developed models. The predicted response did, however, exhibit ratcheting behavior that has been observed experimentally in Gr/Cu. Finally, simulation of the actual fiber distribution of particular specimens had little effect on the predicted thermal expansion.

Bednarcyk, Brett A.↗

SWIFT OBSERVATIONS OF THE ULTRALUMINOUS X-RAY SOURCE HOLMBERG IX X-1

Holmberg IX X-1 is a well-known ultraluminous X-ray source with an X-ray luminosity of {approx}10{sup 40} erg s{sup -1}. The source has been monitored by the X-ray telescope of Swift regularly. Since 2009 April, the source has been in an extended low luminosity state. We utilize the co-added spectra taken at different luminosity states to study the spectral behavior of the source. Simple power-law and multi-color disk blackbody models can be ruled out. The best overall fits, however, are provided by a dual thermal model with a cool blackbody and a warm disk blackbody. This suggests that Holmberg IX X-1 may be a 10 M{sub sun} black hole accreting at seven times above the Eddington limit or a 100 M{sub sun} maximally rotating black hole accreting at the Eddington limit, and we are observing both the inner regions of the accretion disk and outflows from the compact object.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of an inflatable radiator system

Conceptual designs of an inflatable radiator system developed for supplying short duration supplementary cooling of space vehicles are described along with parametric trade studies, materials evaluation/selection studies, thermal and structural analyses, and numerous element tests. Fabrication techniques developed in constructing the engineering models and performance data from the model thermal vacuum tests are included. Application of these data to refining the designs of the flight articles and to constructing a full scale prototype radiator is discussed.

Leach, J. W.↗

Thermal and albedo mapping of the north and south polar regions of Mars

The first maps are presented of the north and south polar regions of Mars. The thermal properties of the midlatitude regions from -60 deg to +60 deg latitude were mapped in previous studies. The presented maps complete the mapping of entire planet. The maps for the north and south polar regions were derived from Viking Infrared Thermal Mapper (IRTM) observations. Best fit thermal inertias were determined by comparing the available IRTM 20 micron channel brightness within a given region to surface temperatures computed by a diurnal and seasonal thermal model. The model assumes no atmospheric contributions to the surface heat balance. The resulting maps of apparent thermal inertia and average IRTM measured solar channel lambert albedo for the north and south polar regions from the poles to +/- 60 deg latitude.

Paige, D. A.↗

Mars aqueous chemistry experiment

Mars Aqueous Chemistry Experiment (MACE) is designed to conduct a variety of measurements on regolith samples, encompassing mineral phase analyses, chemical interactions with H2O, and physical properties determinations. From these data, much can be learned or inferred regarding the past weathering environment, the contemporaneous soil micro-environments, and the general chemical and physical state of the Martian regolith. By analyzing both soil and duricrust samples, the nature of the latter may become more apparent. Sites may be characterized for comparative purposes and criteria could be set for selection of high priority materials on future sample return missions. The second year of the MACE project has shown significant progress in two major areas. MACE Instrument concept definition is a baseline design that has been generated for the complete MACE instrument, including definition of analysis modes, mass estimates and thermal model. The design includes multiple reagent reservoirs, 10 discrete analysis cells, sample manipulation capability, and thermal control. The MACE Measurement subsystems development progress is reported regarding measurement capabilities for aqueous ion sensing, evolved gas sensing, solution conductivity measurement, reagent addition (titration) capabilities, and optical sensing of suspended particles.

Clark, Benton C.↗

Experimental and Numerical Characterization of High Heat Fluxes During Transient Blackbody Calibrations

High heat fluxes are encountered in numerous applications, such as hypersonic vehicles in flight, fires, and engines, Calibration of heat flux gages may be performed in a dual cavity cylindrical blackbody resulting in a transient calibration environment. To characterize the transient heat fluxes. experiments were performed on a dual cavity cylindrical blackbody at nominal temperatures varying from 800 C to 1900 C in increments of 100 C. Based on experiments, the optimum heat flux sensor insertion location as measured from the center partition was determined. The pre-insertion steady state axial temperature profile is compared experimentally, numerically, and analytically. The effect of convection in the blackbody cavity during the insertion is calculated and found to be less than 2 per cent. Also, an empirical correlation for predicting the emissivity of the blackbody is included. Detailed transient thermal models have been developed to simulate the heat flux calibration process at two extreme fluxes. The high (1MW/sq m) and relatively low (70 kw/sq m) fluxes are reported in this article. The transient models show the effect of inserting a heat flux gage at room temperature on the thermal equilibrium of the blackbody at 1800 C and 800 C nominal temperatures, respectively. Also, heat flux sensor outputs are derived from computed sensor temperature distributions and compared to experimental results.