Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Testing and Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

JV Task 119 - Effects of Aging on Treated Activated Carbons

For both the United States and Canada, testing has been under way for electric utilities to find viable and economical mercury control strategies to meet pending future mercury emission limits. The technology that holds the most promise for mercury control in low-chlorine lignite to meet the needs of the Clean Air Act in the United States and the Canada-Wide Standards in Canada is injection of treated activated carbon (AC) into the flue gas stream. Most of the treated carbons are reported to be halogenated, often with bromine. Under a previous multiyear project headed by the Energy & Environmental Research Center (EERC), testing was performed on a slipstream unit using actual lignite-derived flue gas to evaluate various sorbent technologies for their effectiveness, performance, and cost. Testing under this project showed that halogenated ACs performed very well, with mercury capture rates often {ge} 90%. However, differences were noted between treated ACs with respect to reactivity and capacity, possibly as a result of storage conditions. Under certain conditions (primarily storage in ambient air), notable performance degradation had occurred in mercury capture efficiency. Therefore, a small exploratory task within this project evaluated possible differences resulting from storage conditions and subsequent effects of aging that might somehow alter their chemical or physical properties. In order to further investigate this potential degradation of treated (halogenated) ACs, the EERC, together with DOE's National Energy Technology Laboratory, the North Dakota Industrial Commission (NDIC), the Electric Power Research Institute (EPRI), SaskPower, and Otter Tail Power Company, assessed the aging effects of brominated ACs for the effect that different storage durations, temperatures, and humidity conditions have on the mercury sorption capacity of treated ACs. No aging effects on initial capture activity were observed for any carbons or conditions in the investigation. As measured by the 50% breakthrough time, no changes in capacity were observed for Norit LH samples stored frozen and likely none for Norit LH samples stored under high humidity conditions. The major aging effects on capacity for the EERC brominated sample were seen as a decrease in capacity during the first week of storage under high humidity conditions. Storage of the Norit LH and the EERC 5% brominated samples under low humidity conditions resulted in slightly improved capacities. Storage of the 15% brominated sample under high humidity conditions also improved the capacity. Surface analysis using x-ray photoelectron spectroscopy (XPS) showed some migration of bromine to and from the surface occurred during storage, although no net loss of bromine was observed. The migration to the surface in the case of the 15% brominated carbon correlates with the increased capacity observed for this sample. The XPS elemental speciation data for the EERC brominated carbons showed a trend toward more bromide being formed at the expense of covalent bromine during storage. This was especially great for the 15% and the 5% stored in low humidity. The Norit LH samples did not show this increase in bromide concentration. This is consistent with the lack of change in capacity for the Norit LH during storage. The carbon speciation data showed generally more oxidization of carbon surfaces with storage, especially formation of carboxylate groups. The least increase in carboxylate groups was seen for the Norit LH stored under low humidity, which correlates with its increased capacity. In conclusion, the observed changes in surface chemistry can be related to the minimal changes in capacity observed, but the factors operate in different directions, so the relationships are complex. High-quality x-ray absorption fine structure spectra were obtained for most of the samples. Significant changes were observed in the x-ray absorption near edge structure and extended x-ray absorption fine structure spectra of the stored carbons, but proved difficult to interpret and correlate with structural changes.

01 COAL, LIGNITE, AND PEAT↗

Methods for Quantifying the Uncertainties of LSIT Test Parameters, Test Results, and Full-Scale Mixing Performance Using Models Developed from Scaled Test Data

This report discusses the statistical methods for quantifying uncertainties in 1) test responses and other parameters in the Large Scale Integrated Testing (LSIT), and 2) estimates of coefficients and predictions of mixing performance from models that relate test responses to test parameters. Testing at a larger scale has been committed to by Bechtel National, Inc. and the U.S. Department of Energy (DOE) to “address uncertainties and increase confidence in the projected, full-scale mixing performance and operations” in the Waste Treatment and Immobilization Plant (WTP).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Standardized Analysis Process Using Digital Image Correlation to Calculate In Situ Cladding Strain from Modified Burst Tests for Fuel Performance Code Validation

Historical data collection on nuclear fuel cladding materials has focused on generating a statistically significant amount of data to assess the material and its failure behavior. Furthermore, data generated to support material model and failure criteria development were previously posttest evaluations, so a large number of tests was required to gain new understanding. A way to expedite this process is to develop techniques capable of generating large, high-fidelity data sets from a single test with lower uncertainty or quantified uncertainty. One such example of this approach is Oak Ridge National Laboratory’s use of modified burst tests (MBTs) to analyze the mechanical behavior and failure conditions of cladding during a simulated reactivity-initiated accident (RIA). Each test incorporates digital image correlation (DIC) analysis techniques that are used to assess the accumulated strain in situ, as well as eventual cladding failure. This work has been fruitful in defining strain-to-failure conditions for materials like silicon carbide (SiC) fiber–reinforced/SiC matrix composite tubes (SiC/SiC), iron-chromium-aluminum (FeCrAl) alloy tubes, and chromium-coated Zircaloy-4 tubes. However, there are numerous DIC software available, including open-source and proprietary software. The different DIC software use various algorithms to process images and calculate displacement values. Using these different software and algorithms can lead to varying results, and perhaps larger-than-expected uncertainties. In the present study, previously published MBT data encompassing a variety of test conditions were reanalyzed with two different DIC software to assess the variance in the calculated strain results. The data consisted of SiC/SiC, FeCrAl, and chromium-coated Zircaloy-4 tubes. Plots of the calculated strains during the transient revealed good agreement between the two DIC software. The average root-mean-square errors between the two software was 0.20% strain, which is slightly larger than a previously reported error value for these tests. In conclusion, this variance in results is low enough that this analysis method can be used for code validation.

Reactivity-initiated accident↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗

Test Methods for Cementitious Seal Materials for Borehole Disposal - 17352

The Nuclear and Energy Research Institute (IPEN-CNEN/SP) in Sao Paulo-Brazil, is considering borehole disposal of disused sealed radioactive sources (DSRS), which were used in smoke detectors, lightning arresters, radiotherapy, industrial gauges, irradiators, and other applications. The current IPEN concept of borehole is a modified BOSS system developed by the International Atomic Energy Agency (IAEA). It differs from the IAEA's design in that the disposal zone is below 300 m, and the DSRS are placed directly in the disposal packages constituted of stainless steel containers with 1.5 L capacity. A borehole drilled through sediment and granite, stabilized with stainless steel casing and cement grout is proposed for the conceptual model. Standard cement-material test methods and performance specific test methods, including accelerated aging methods, are needed for modeling the performance of the candidate cementitious grouts. A cross-disciplinary team from the USA Savannah River National laboratory is providing technical assistance to IPEN in this performance assessment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploring Hilbert space on a budget: Novel benchmark set and performance metric for testing electronic structure methods in the regime of strong correlation

This work explores the ability of classical electronic structure methods to efficiently represent (compress) the information content of full configuration interaction (FCI) wave functions. We introduce a benchmark set of four hydrogen model systems of different dimensionalities and distinctive electronic structures: a 1D chain, a 1D ring, a 2D triangular lattice, and a 3D close-packed pyramid. To assess the ability of a computational method to produce accurate and compact wave functions, we introduce the accuracy volume, a metric that measures the number of variational parameters necessary to achieve a target energy error. Using this metric and the hydrogen models, we examine the performance of three classical deterministic methods: (i) selected configuration interaction (sCI) realized both via an a posteriori (ap-sCI) and variational selection of the most important determinants, (ii) an a posteriori singular value decomposition (SVD) of the FCI tensor (SVD-FCI), and (iii) the matrix product state representation obtained via the density matrix renormalization group (DMRG). We find that the DMRG generally gives the most efficient wave function representation for all systems, particularly in the 1D chain with a localized basis. For the 2D and 3D systems, all methods (except DMRG) perform best with a delocalized basis, and the efficiency of sCI and SVD-FCI is closer to that of DMRG. For larger analogs of the models, the DMRG consistently requires the fewest parameters but still scales exponentially in 2D and 3D systems, and the performance of SVD-FCI is essentially equivalent to that of ap-sCI.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transient Testing of Nuclear Fuels Performed in the Original Operation of TREAT (First Edition)

This report provides summary information on a selected set of key historic experiment series which were performed in the Transient Reactor Test Facility (TREAT) during its original operation from 1959-1994. The selected experiments are intended to illustrate the diversity in experiments which have been performed, and the range in capabilities of the TREAT reactor. Knowledge of those prior experiments provides a foundation for qualification and safety evaluation of numerous fuel forms already tested in TREAT, planning and designing new future tests, and for future TREAT operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CATHARE calculations of Phenix ultimate natural convection test

The Phenix Sodium cooled Fast Reactor (SFR) started operation in 1973 and it was stopped in 2009. Before the reactor was definitively shutdown, in order to collect experimental data for code assessments in the frame of Generation IV an intensive program of ultimate tests was set up. Among these ultimate experiments, two thermal hydraulic tests were performed: an asymmetrical test consisting in a trip on one secondary pump and a natural convection test in the primary circuit. The natural convection test has been used for an international benchmark on system codes in the frame of the IAEA. The CATHARE code - initially developed for water cooled reactors and now extended for safety analyses for other kinds of reactors, including Sodium Fast Reactor - was used by CEA for this benchmark. The paper reminds briefly the Phenix reactor with the main physical parameters and the instrumentation used during the natural convection test. Main test results are also briefly reminded including the evolution of the core and the heat exchangers inlet and outlet temperatures, and some local temperature measurements. The main developments to perform CATHARE SFR computations and the strategy of system code assessment are presented. Then the CATHARE modelling of Phenix reactor is depicted and the various assumptions are pointed out. CATHARE encountered no problem to predict the initial nominal state. Afterwards, the whole transient scenario is calculated and CATHARE calculations are compared to the Phenix measurements. The global trend is rather well predicted by the CATHARE code. Nevertheless, due to complex flow phenomena occurring in large plena and components, the system code encountered physical limitations, leading to remaining discrepancies between code prediction and plant data. Various sensitivity calculations are presented and they bring partial answers. Additional analyses are in progress to understand more deeply the complex 3D phenomena involved during the different phases of the natural convection test. Additional work for coupling CATHARE system code and TRIO-U CFD code is in progress and will bring useful information to better understand the physical phenomena involved during the natural convection test and to improve system modeling for future SFR safety analysis. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-F-P-39: End-To-End Validation of a 6 MV High Dose Rate Photon Beam, Configured for Eclipse AAA Algorithm Using Golden Beam Data, for SBRT Treatments Using RapidArc

Purpose: To use end-to-end testing to validate a 6 MV high dose rate photon beam, configured for Eclipse AAA algorithm using Golden Beam Data (GBD), for SBRT treatments using RapidArc. Methods: Beam data was configured for Varian Eclipse AAA algorithm using the GBD provided by the vendor. Transverse and diagonals dose profiles, PDDs and output factors down to a field size of 2×2 cm2 were measured on a Varian Trilogy Linac and compared with GBD library using 2% 2mm 1D gamma analysis. The MLC transmission factor and dosimetric leaf gap were determined to characterize the MLC in Eclipse. Mechanical and dosimetric tests were performed combining different gantry rotation speeds, dose rates and leaf speeds to evaluate the delivery system performance according to VMAT accuracy requirements. An end-to-end test was implemented planning several SBRT RapidArc treatments on a CIRS 002LFC IMRT Thorax Phantom. The CT scanner calibration curve was acquired and loaded in Eclipse. PTW 31013 ionization chamber was used with Keithley 35617EBS electrometer for absolute point dose measurements in water and lung equivalent inserts. TPS calculated planar dose distributions were compared to those measured using EPID and MapCheck, as an independent verification method. Results were evaluated with gamma criteria of 2% dose difference and 2mm DTA for 95% of points. Results: GBD set vs. measured data passed 2% 2mm 1D gamma analysis even for small fields. Machine performance tests show results are independent of machine delivery configuration, as expected. Absolute point dosimetry comparison resulted within 4% for the worst case scenario in lung. Over 97% of the points evaluated in dose distributions passed gamma index analysis. Conclusion: Eclipse AAA algorithm configuration of the 6 MV high dose rate photon beam using GBD proved efficient. End-to-end test dose calculation results indicate it can be used clinically for SBRT using RapidArc.

60 APPLIED LIFE SCIENCES↗

Pt-functionalized reduced graphene oxide for excellent hydrogen sensing at room temperature

Cost effective and faster detection of H{sub 2} has always remained a challenge. We report synthesis of reduced graphene oxide (RGO)–Pt composite and its application as highly sensitive and selective H{sub 2} sensors at room temperature. Four samples by varying the ratio of RGO and Pt were prepared to test their sensing performance. The tests were carried out in inert (N{sub 2}) ambience as well as air ambience. It was observed that the RGO:Pt (1:3) 1 h reduced sample demonstrated the best H{sub 2} sensing performance in terms of sensitivity, response time, and recovery time at room temperature. Its response varied from ∼19% (200 ppm) to 57% (5000 ppm) against H{sub 2} in air ambience. Also, the response time and recovery time of the RGO:Pt (1:3) sample were found to be as fast as 65 s and 230 s against 5000 ppm, respectively, in air ambience. In N{sub 2} ambience, the RGO:Pt (1:3) sample demonstrated the best response of −97% (500 ppm), but its recovery was found to be poor. The RGO–Pt composite formation was verified by high resolution transmission electron microscopy and X-ray photoelectron spectroscopy. The detailed physics behind the sensing mechanisms have been explained and experimentally verified in this work.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Recent Radioactive Material Package Testing Experiences at Oak Ridge National Laboratory

Oak Ridge National Laboratory (ORNL) was a pioneer in the testing of radioactive material shipping packages and has been performing such tests for over 50 years. Currently, except for Type B thermal tests, testing is performed at the purpose-built Packaging Research Facility that is located at the National Transportation Research Center - a U.S. Department of Energy User Facility. Packages used for the transportation of Type B quantities of radioactive materials must be capable of meeting normal conditions of transportation (NCT) requirements and hypothetical accident conditions (HAC) requirements as defined in Title 10 Code of Federal Regulations (CFR) Part 71. Evaluation of package designs to these criteria typically involves a combination of analysis and physical testing. Required physical tests include free drop, crush, puncture, penetration, compression, vibration, water spray, water immersion, and thermal. The Oak Ridge National Laboratory (ORNL) Packaging Evaluation Facility (PEF) at the National Transportation Research Center (NTRC) provides an inclusive testing capability for a wide variety of packages needed for shipment of radioactive materials. Since PATRAM 2019, ORNL has performed several sets of tests including testing of two designs of the Defense Program Package (DPP-3 and DPP-1) and several Special Form Capsules. This paper provides an overview of the testing performed as well as a summary of advancements made to the ORNL package testing program during that time.

Martinez, Oscar↗

Balance of Attraction and Repulsion in Nucleic-Acid Base Stacking: CCSD(T)/Complete-Basis-Set-Limit Calculations on Uracil Dimer and a Comparison with the Force-Field Description

We have carried out reference quantum-chemical calculations for about 100 geometries of the uracil dimer in stacked conformations. The calculations have been specifically aimed at geometries with unoptimized distances between the monomers including geometries with mutually tilted monomers. Such geometries are characterized by a delicate balance between local steric clashes and local unstacking and had until now not been investigated using reference quantummechanics (QM) methods. Nonparallel stacking geometries often occur in nucleic acids and are of decisive importance, for example, for local conformational variations in B-DNA. Errors in the shortrange repulsion region would have a major impact on potential energy scans which were often used in the past to investigate local geometry variations in DNA. An incorrect description of such geometries may also partially affect molecular dynamics (MD) simulations in applications when quantitative accuracy is required. The reference QM calculations have been carried out using the MP2 method extrapolated to the complete basis-set limit and corrected for higher-order electron-correlation contributions using CCSD(T) calculations with a medium-sized basis set. These reference calculations have been used as benchmark data to test the performance of the DFT-D, SCS(MI)-MP2, and DFTSAPT QM methods and of the AMBER molecular-mechanics (MM) force field. The QM methods show close to quantitative agreement with the reference data, albeit the DFT-D method tends to modestly exaggerate the repulsion of steric clashes. The force field in general also provides a good description of base stacking for the systems studied here. However, for geometries with close interatomic contacts and clashes, the repulsion effects are rather severely exaggerated. The discrepancy reported here should not affect the overall stability of MD simulations and qualitative applications of the force field. However, it may affect the description of subtle quantitative effects such as the local conformational variations in B-DNA. Preliminary calculations for two H-bonded uracil base pairs, including one with a C-H· · ·O H-bond, indicate excellent performance of the tested QM methods for all intermonomer distances. The force field, on the other hand, is less satisfactory, especially in the repulsive regions.

59 BASIC BIOLOGICAL SCIENCES↗

Recent performance and ignition tests of the pulsed SNS H{sup −} source for 1-MW neutron production

After acquiring several reliable spare targets, SNS ramped the beam power from 850 kW to 1.4 MW, which required an increase in H{sup −} beam pulse length from 0.88 to 1.0 ms at 60 Hz. This increase initially produced slow 2-MHz power ramp-ups and, after several weeks of uninterrupted operation, it produced plasma outages every time the pulse length was raised above ∼0.95 ms. Similar outages were previously observed towards the end of long service cycles, which were believed to indicate that the breakdown voltage of the high purity hydrogen started to exceed the induced electric fields. In 2011 the RF was reconfigured to start with 10 cycles of 1.96 MHz, which yielded the shortest H{sup −} beam rise times and apparently eliminated those plasma outages. The new, pulse-length dependent outages were eliminated by increasing the initial frequency to 1.985 MHz. However, careful frequency studies are unable to justify this frequency. In addition, the paper discusses the issues and solutions for the electron-dump voltage, which starts to sag and become unstable after several weeks of high current operation. At the request of the authors and the Proceedings Editor this article has been updated to include References 3–13, which were present in the author’s original submission but were lost during manuscript processing in the Proceedings Editor's office. The updated article was published on 5 May 2015.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Use of the WECC WAMS in Wide Area Probing Tests for Validation of System Performance & Modeling

During 2005 and 2006 the Western Electricity Coordinating Council (WECC) performed three major tests of western system dynamics. These tests used a Wide Area Measurement System (WAMS) based primarily on Phasor Measurement Units (PMUs) to determine response to events including the insertion of the 1400-MW Chief Joseph braking resistor, probing signals, and ambient events. Test security was reinforced through real-time analysis of wide area effects, and high-quality data provided dynamic profiles for interarea modes across the entire western interconnection. The tests established that low-level optimized pseudo-random ±20-MW probing with the Pacific DC Intertie (PDCI) roughly doubles the apparent noise that is natural to the power system, providing sharp dynamic information with negligible interference to system operations. Such probing is an effective alternative to use of the 1400-MW Chief Joseph dynamic brake, and it is under consideration as a standard means for assessing dynamic security.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Verification study of an emerging fire suppression system

Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Moreover, plutonium gloveboxes present harsh environmental conditions for polymer materials; these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. Several studies have been conducted to determine the robustness of selfcontained fire extinguishers in plutonium gloveboxes in a nuclear facility, verification tests must be performed. These tests include activation and mass loss calorimeter tests. In addition, compatibility issues with chemical components of the self-contained fire extinguishers need to be addressed. Our study presents activation and mass loss calorimeter test results. After extensive studies, no critical areas of concern have been identified for the plutonium glovebox application of Fire Foe™, except for glovebox operations that use large quantities of bulk plutonium or uranium metal such as metal casting and pyro-chemistry operations.

42 ENGINEERING↗

On the toughness scatter in low alloy C-Mn steel samples fabricated using wire arc additive manufacturing

Low alloy carbon manganese (C-Mn) steel builds were fabricated using a wire based additive manufacturing system developed at Oak Ridge National Laboratory. Specimens were fabricated in the X,Y and Z direction and detailed mechanical testing was performed. The mechanical testing results showed a significant scatter in tensile ductility and significant variation in Charpy toughness. Further detailed microstructure characterization showed significant microstructural heterogeneity in builds fabricated in each direction. The scatter in mechanical properties was then rationalized based on the microstructural observations and the underlying changes in the local heat transfer conditions. Lastly, the results indicate that when fabricating parts using C-Mn low alloy steel welds the process parameters and tool path should be chosen such that the cooling rate from 800 °C to 500 °C is greater than 30 s to avoid formation of martensite austenite (MA) phases, which leads to toughness reductions.

36 MATERIALS SCIENCE↗