Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,495 records · Page 83

Improving cellulose attribution by selectively removing yeast glucans from grain fermentation intermediates

Abstract This article presents an industry-relevant method for quantifying cellulose in mixed substrate samples. We built upon the cellulosic glucan measurement proposed by Sluiter et al. (2021) to investigate significant cellulose loss under cold caustic conditions, which has hindered the establishment of an industrially relevant method. To overcome this issue, we used dimethyl sulfoxide (DMSO) as an alternative solvent, which avoids mercerization reactions (Budtova and Navard 2015) but may leave some resistant starch in the sample. Treatment via an enzyme mixture removed starch and conformed to US Environmental Protection Agency (EPA) guidance on cellulose measurement by establishing quantitative de-starching via nuclear magnetic resonance (EPA 2022). The selective removal of yeast beta-glucan was accomplished using a commercially available Zymolyase. Our results demonstrated excellent reproducibility, with coefficients of variance of 7.14% or less, when measuring cellulose in low cellulose content samples. The method was tested on relevant lab and plant samples, showing an average 0.9% ethanol derived from the conversion of cellulose when cellulase was added to the process and zero response when no cellulase was added. These findings indicate that a cellulose method using DMSO and pullulanase provides a complete and accurate view of cellulose content, composition, and conversion in industrial fermentation processes.

Sluiter, Justin [National Renewable Energy Laborat↗

Tests Of The Extended Range SRF Cavity Tuners For The LCLS-II-HE Project*

The LCLS-II HE superconducting linac can produce multi-energy beams by supporting multiple undulator lines simultaneously. This could be achieved by using the cavity SRF tuner in the off-frequency detune mode. This off-frequency operation method was tested in the verification cryomodule (vCM) and CM 1 at Fermilab at 2 K. In both cases, the tuners achieved a frequency shift of -565$\pm$80 kHz. This study will discuss cavity frequency during each step as it is being assembled in the cryomodule string and finally when it is being tested at 2 K. Tracking the cavity frequency helped enable the tuners to reach this large frequency shift. The specific procedures of tuner setting during assembly will be presented.

43 PARTICLE ACCELERATORS↗

Evaluation of partial volume correction and analysis of longitudinal [ 18 F]GTP1 tau PET imaging in Alzheimer's disease using linear mixed-effects models

Purpose: We evaluated the impact of partial volume correction (PVC) methods on the quantification of longitudinal [ 18 F]GTP1 tau positron-emission tomography (PET) in Alzheimer's disease and the suitability of describing the tau pathology burden temporal trajectories using linear mixed-effects models (LMEM). Methods: We applied van Cittert iterative deconvolution (VC), 2-compartment, and 3-compartment, and the geometric transfer matrix plus region-based voxelwise methods to data acquired in an Alzheimer's disease natural history study over 18 months at a single imaging site. We determined the optimal PVC method by comparing the standardized uptake value ratio change (%ΔSUVR) between diagnostic and tau burden–level groups and the longitudinal repeatability derived from the LMEM. The performance of LMEM analysis for calculating %ΔSUVR was evaluated in a natural history study and in a multisite clinical trial of semorinemab in prodromal to mild Alzheimer's disease by comparing results to traditional per-visit estimates. Results: The VC, 2-compartment, and 3-compartment PVC methods had similar performance, whereas region-based voxelwise overcorrected regions with a higher tau burden. The lowest within-subject variability and acceptable group separation scores were observed without PVC. The LMEM-derived %ΔSUVR values were similar to the per-visit estimates with lower variability. Conclusion: The results indicate that the tested PVC methods do not offer a clear advantage or improvement over non-PVC images for the quantification of longitudinal [ 18 F]GTP1 PET data. LMEM offers a robust framework for the longitudinal tau PET quantification with low longitudinal test–retest variability. Clinical trial registration: NCT02640092 and NCT03289143.

60 APPLIED LIFE SCIENCES↗

Angular-spatial hp -adaptivity for radiative transfer with discontinuous Galerkin spectral element methods

Radiative transfer is important for many science and engineering applications, and numerical simulations of radiative transfer can be challenging. For instance, the radiation field is seven-dimensional – three spatial, two angular, one wavelength, and one temporal – and often features steep gradients. Therefore, memory usage is a key issue. To reduce memory, some past work has investigated the use of adaptive mesh refinement (AMR), typically for either the spatial or angular coordinate, and typically for only h -adaptivity. Here, we propose the use of AMR for the spatial and angular coordinates together, and the use of h - and p -adaptivity together as hp -AMR for the potential for further memory savings. We implemented the proposed method for several test cases in two spatial and one angular dimension, with the discontinuous Galerkin spectral element method. These test cases featured highly anisotropic angular radiation, with or without steep spatial gradients. Our primary findings from these test cases were: (1) Angular hp -adaptivity can deliver the radiation solution with the same accuracy as, and with much less computational memory than, uniform angular h - or p -refinements, or angular h -adaptivity alone. This is most obvious when the incoming radiation is highly anisotropic, in which case the savings can be orders of magnitude. (2) Full spatial-angular hp -adaptivity is more efficient in solution representation, compared to solely spatial or solely angular -adaptivity. This is most evident when steep gradients are present in both the spatial and angular distribution. These results suggest that adaptive spatial- hp angular-refinement may perform well in large-scale seven-dimensional applications.

Adaptive refinement↗

Prediction of hydrogen adsorption in nanoporous materials from the energy distribution of adsorption sites

We present a fast and accurate, semi-analytical method for predicting hydrogen adsorption in nanoporous materials. For any temperature and pressure, the adsorbed amount is calculated as an integral over the energy density of adsorption sites (guest-host interactions) plus an average guest-guest term. The guest-host interaction energy is calculated using a classical force field with hydrogen modelled as a single-site probe. The guest-guest interaction energy is approximated using an average coordination number, which is regressed using Gaussian Process Regression (GPR). Local adsorption at each site is then modelled using a Langmuir isotherm, which when weighted with its probability density gives an accurate description of hydrogen adsorption. The method is tested on 933 metal-organic frameworks (MOFs) from the Computation-Ready Experimental (CoRE) MOF database at 77 K from 10 –5 to 100 bar, and the results are compared against GCMC predictions. To demonstrate the utility of the method, we calculated hydrogen adsorption isotherms for 12,914 existing MOF structures, at two different temperatures at a speed about 100 times that of GCMC simulations and analyzed the results. Here, we found 13 MOFs with predicted deliverable capacities exceeding the DOE target of 50 g/L for adsorption at 100 bar, 77 K and desorption at 5 bar, 160 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Closed-Loop Error Learning Control for Uncertain Nonlinear Systems With Experimental Validation on a Mobile Robot

This article develops a closed-loop error learning control (CLELC) algorithm for feedback linearizable systems with experimental validation on a mobile robot. Traditional feedback and feedforward controllers are designed based on the nominal model by using the feedback linearization control (FLC) method. Then, an intelligent controller is designed based on the sliding mode learning algorithm that utilizes closed-loop error dynamics to learn the system behavior. The controllers are working in parallel, and the intelligent controller can gradually replace the feedback controller from the control of the system. In addition to the stability of the sliding mode learning algorithm, the closed-loop stability of an nth-order feedback linearizable system is proven. The simulation results demonstrate that the CLELC algorithm can improve control performance (e.g., smaller rise time, settling time, and overshoot) in the absence of uncertainties, and also provides robust control performance in the presence of uncertainties as compared to traditional FLC method. To test the efficiency and efficacy of the CLELC algorithm, the trajectory tracking problem of a tracked mobile robot is studied in real time. The experimental results demonstrate that the CLELC algorithm ensures highly accurate trajectory tracking performance than traditional FLC method.

97 MATHEMATICS AND COMPUTING↗

Round Robin Summary for ASTM Method C1733

This report was prepared to summarize the results of an inter- and intra-laboratory round robin of ASTM Method C1733-17 (now C1733-20a) Distribution Coefficients of Inorganic Species by the Batch Method. The testing used the sorption of cesium (Cs) to a standard reference soil from the San Joaquin Valley (Standard Reference Material 2709a). The data collected from the nine participants was used for a statistical analysis to assess the precision of the method and generate a precision and bias statement to update the C1733-20a standard.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Tests of Exchange-Correlation Functional Approximations Against Reliable Experimental Data for Average Bond Energies of 3d Transition Metal Compounds

One of the greatest challenges for the theoretical study of transition-metal-containing compounds is the treatment of intrinsically multi-configurational atoms and molecules, which require a multireference (MR) treatment in wave function theory. The accuracy of density functional theory for this kind of system is still being explored. Here, we continue that exploration by presenting the predictions of 42 exchange-correlation (xc) functionals of 11 types [local spin density approximation (LSDA), generalized gradient approximation (GGA), nonseparable gradient approximation (NGA), global-hybrid GGA, meta-GGA, meta-NGA, global-hybrid meta-GGA, range-separated hybrid GGA, range-separated hybrid meta-GGA, range-separated hybrid meta-NGA, and DFT augmented with molecular mechanics damped dispersion (DFT-D)]. DFT-D is tested both for Grimme’s DFT-D3(BJ) model with Becke-Johnson damping and for ωB97X-D, which has the empirical atom-atom dispersion parametrized by Chai and Head-Gordon. The Hartree-Fock (HF) method has also been included because it can be viewed as a functional with 100% HF exchange and no correlation. These methods are tested against a database including 70 first-transition-row (3d) transition metal-containing molecules (19 single-reference molecules and 51 MR molecules), all of which have estimated experimental uncertainties equal to or less than 2.0 kcal/mol in the heat of formation. We analyze the accuracy in terms of the atomization energy per bond instead of the enthalpy of formation of the molecule because it allows us to test electronic energies without the possibility of cancellation of errors in electronic energies with errors in vibrational energies. All the density functional and HF wave functions have been optimized to a stable solution, in which the spatial symmetry is allowed to be broken to minimize the energy to a stable solution. We find that Ï„-HCTHhyb has the smallest mean unsigned error (MUE) in average bond energy, in particular 2.5 kcal/mol, for the full set of 70 molecules, and it also gives the smallest MUE for MR systems. For single-reference systems, MPW1B95 has the best performance, with an MUE of 1.6 kcal/mol. Among local functionals, which are the least expensive, the best performance (MUE = 3.9 kcal/mol) for the total database is achieved by OreLYP, OLYP, M06-L, and τ-HCTH. It is observed that adding HF exchange does not guarantee better accuracy for GGAs or for the NGA, but inclusion of the kinetic energy densities can benefit the GGAs and NGA calculations. The metal hydrides and metal oxides are demonstrated to be most difficult bond types to predict, and CrO 3 , FeH, CrO, VH and MnS are found to be the most difficult molecules to predict. The middle transition metals (V, Cr, and Mn) lead to larger errors on average than either the early or late transition metals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-P-37: Implementation of An End-To-End QA Test of the Radiation Therapy Imaging, Planning and Delivery Process to Identify and Correct Possible Sources of Deviation

Purpose: To implement an end-to-end QA test of the radiation therapy imaging, planning and delivery process, aimed to assess the dosimetric agreement accuracy between planned and delivered treatment, in order to identify and correct possible sources of deviation. To establish an internal standard for machine commissioning acceptance. Methods: A test involving all steps of the radiation therapy: imaging, planning and delivery process was designed. The test includes analysis of point dose and planar dose distributions agreement between TPS calculated and measured dose. An ad hoc 16 cm diameter PMMA phantom was constructed with one central and four peripheral bores that can accommodate calibrated electron density inserts. Using Varian Eclipse 10.0 and Elekta XiO 4.50 planning systems, IMRT, RapidArc and 3DCRT with hard and dynamic wedges plans were planned on the phantom and tested. An Exradin A1SL chamber is used with a Keithley 35617EBS electrometer for point dose measurements in the phantom. 2D dose distributions were acquired using MapCheck and Varian aS1000 EPID.Gamma analysis was performed for evaluation of 2D dose distribution agreement using MapCheck software and Varian Portal Dosimetry Application.Varian high energy Clinacs Trilogy, 2100C/CD, 2000CR and low energy 6X/EX where tested.TPS-CT# vs. electron density table were checked for CT-scanners used. Results: Calculated point doses were accurate to 0.127% SD: 0.93%, 0.507% SD: 0.82%, 0.246% SD: 1.39% and 0.012% SD: 0.01% for LoX-3DCRT, HiX-3DCRT, IMRT and RapidArc plans respectively. Planar doses pass gamma 3% 3mm in all cases and 2% 2mm for VMAT plans. Conclusion: Implementation of a simple and reliable quality assurance tool was accomplished. The end-to-end proved efficient, showing excellent agreement between planned and delivered dose evidencing strong consistency of the whole process from imaging through planning to delivery. This test can be used as a first step in beam model acceptance for clinical use.

60 APPLIED LIFE SCIENCES↗

Axial-scanning low-coherence interferometer method for noncontact thickness measurement of biological samples

We investigated a high-precision optical method for measuring the thickness of biological samples regardless of their transparency. The method is based on the precise measurement of optical path length difference of the end surfaces of objects, using a dual-arm axial-scanning low-coherence interferometer. This removes any consideration of the shape, thickness, or transparency of testing objects when performing the measurement. Scanning the reference simplifies the measurement setup, resulting in unambiguous measurement. Using a 1310 nm wavelength superluminescent diode, with a 65 nm bandwidth, the measurement accuracy was as high as 11.6 {mu}m. We tested the method by measuring the thickness of both transparent samples and nontransparent soft biological tissues.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling Turbulence in Galactic Centers

Turbulence is a prevalent phenomenon in the interstellar medium, and in particular, the environment at the centers of galaxies. For example, detailed observations of the Milky Way’s Central Molecular Zone (CMZ) revealed that it has a complex and turbulent structure. Turbulence on galactic scales is often modeled using star formation and feedback. However, these effects do not appear to be sufficient for explaining the high-velocity dispersion observed in the CMZ, indicating that additional gas-stirring processes are likely to be operating. Here we introduce a proof-of-concept method to drive turbulence in gas that orbits under the influence of a galactic potential. Instead of relying on a particular physical mechanism, we have adopted a Fourier forcing module and have applied it using a smoothed particle hydrodynamics code. To test our method, we performed simulations of a simplistic model of the CMZ. Our turbulence injection method is capable of balancing the self-gravity of the gas, which allows us to run the simulations for long timescales and thereby follow the evolution of the CMZ. Our results show that turbulence induces a flocculent spiral pattern in our model, analogous to that found in galactic-scale simulations. Furthermore, we find that our turbulence injection method induces inward migration of gas, a result consistent with previous numerical simulations. We submit that this injection method is a promising new tool to simulate turbulence in galactic centers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Three-body hyperspherical method with infinite angular expansions

The hyperspherical method based on infinite angular expansions is introduced. We approximate the cusp behavior of a wave function using B-spline techniques. Calculations for the ground-state energies of the atomic helium and the e{sup +}Li system are presented as two examples for testing this method. The computed ground-state energy of He is -2.903 724 a.u. with single particle orbitals l{sub max}=8. For the e{sup +}Li system, with l{sub max}=9, the ground-state energy is -0.250 83 a.u., which is better than the configuration interaction result of -0.250 107 82 a.u. with l{sub max}=30.

74 ATOMIC AND MOLECULAR PHYSICS↗

Budget Constrained Machine Learning for Early Prediction of Adverse Outcomes for COVID-19 Patients

Background: Machine learning (ML) based risk stratification models of Electronic Health records (EHR) data may help to optimize treatment of COVID-19 patients, but are often limited by their lack of clinical interpretability and cost of laboratory tests. We develop a ML based tool for predicting adverse outcomes based on EHR data to optimize clinical utility under a given cost structure. This cohort study was performed using deidentified EHR data from COVID-19 patients from ProMedica Healthcare in northwest Ohio and southeastern Michigan. Methods: We tested performance of various ML approaches for predicting either increasing ventilatory support or mortality and the set of model features under a budget constraint was optimized via exhaustive search across all combinations of features. Results: The optimal sets of features for predicting ventilation under any budget constraint included demographics and comorbidities (DCM), basic metabolic panel (BMP), D-dimer, lactate dehydrogenase (LDH), erythrocyte sedimentation rate (ESR), CRP, brain natriuretic peptide (BNP), and procalcitonin and for mortality included DCM, BMP, complete blood count, D-dimer, LDH, CRP, BNP, procalcitonin and ferritin. Conclusions: This study presents a quick, accurate and cost-effective method to evaluate risk of deterioration for patients with SARS-CoV-2 infection at the time of clinical evaluation.

Cadena Pico, JoseE.↗

A New Geometric Method Based on Two-Dimensional Transmission Electron Microscopy for Analysis of Interior versus Exterior Pd Loading on Hollow Carbon Nanofibers

Hallow carbon nanofibers (CNFs) are being explored as catalyst supports because of their unique properties; catalytic activities with both interior and exterior metal loadings are being evaluated. Electron tomography (3D transmission electron microscopy, 3D TEM) has been used to estimate internal versus external loading of metal nanoclusters. However, this method is time consuming and requires a specialized TEM. We prepared three hollow CNF supported Pd samples with various Pd localizations, and developed a geometric analysis method based on 2D TEM images to estimate Pd internal versus external loading percentages. Results show the similar localization for the same sample in terms of the number, surface area, and mass of Pd nanoclusters but distinct values for different samples. To test our method, we compare results for one segment of a CNF using both 3D scanning transmission electron microscopy (3D TEM) and our new 2D geometic analysis method. Agreement is within 15.1%. Our results also agree with 3D TEM results from the literature for similarly prepared Pd on CNFs (within 5.6%). Our geometric analysis method is proposed as a more straightforward and fast way to evaluate metal nanocluster localizations on tubular supports.

2D↗

Advanced Stress, Strain And Geometrical Analysis In Semiconductor Devices

High stresses and defect densities increases the risk of semiconductor device failure. Reliability studies on potential failure sources have an impact on design and are essential to assure the long term functioning of the device. Related to the dramatically smaller volume of semiconductor devices and new bonding techniques on such devices, new methods in testing and qualification are needed. Reliability studies on potential failure sources have an impact on design and are essential to assure the long term functioning of the device. In this paper, the applications of advanced High Resolution X-ray Diffraction (HRXRD) methods in strain, defect and deformation analysis on semiconductor devices are discussed. HRXRD with Rocking Curves (RC's) and Reciprocal Space Maps (RSM's) is used as accurate, non-destructive experimental method to evaluate the crystalline quality, and more precisely for the given samples, the in-situ strain, defects and geometrical parameters such as tilt and bending of device. The combination with advanced FEM simulations gives the possibility to support efficiently semiconductor devices design.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fast and anisotropic flexibility-rigidity index for protein flexibility and fluctuation analysis

Protein structural fluctuation, typically measured by Debye-Waller factors, or B-factors, is a manifestation of protein flexibility, which strongly correlates to protein function. The flexibility-rigidity index (FRI) is a newly proposed method for the construction of atomic rigidity functions required in the theory of continuum elasticity with atomic rigidity, which is a new multiscale formalism for describing excessively large biomolecular systems. The FRI method analyzes protein rigidity and flexibility and is capable of predicting protein B-factors without resorting to matrix diagonalization. A fundamental assumption used in the FRI is that protein structures are uniquely determined by various internal and external interactions, while the protein functions, such as stability and flexibility, are solely determined by the structure. As such, one can predict protein flexibility without resorting to the protein interaction Hamiltonian. Consequently, bypassing the matrix diagonalization, the original FRI has a computational complexity of O(N{sup 2}). This work introduces a fast FRI (fFRI) algorithm for the flexibility analysis of large macromolecules. The proposed fFRI further reduces the computational complexity to O(N). Additionally, we propose anisotropic FRI (aFRI) algorithms for the analysis of protein collective dynamics. The aFRI algorithms permit adaptive Hessian matrices, from a completely global 3N × 3N matrix to completely local 3 × 3 matrices. These 3 × 3 matrices, despite being calculated locally, also contain non-local correlation information. Eigenvectors obtained from the proposed aFRI algorithms are able to demonstrate collective motions. Moreover, we investigate the performance of FRI by employing four families of radial basis correlation functions. Both parameter optimized and parameter-free FRI methods are explored. Furthermore, we compare the accuracy and efficiency of FRI with some established approaches to flexibility analysis, namely, normal mode analysis and Gaussian network model (GNM). The accuracy of the FRI method is tested using four sets of proteins, three sets of relatively small-, medium-, and large-sized structures and an extended set of 365 proteins. A fifth set of proteins is used to compare the efficiency of the FRI, fFRI, aFRI, and GNM methods. Intensive validation and comparison indicate that the FRI, particularly the fFRI, is orders of magnitude more efficient and about 10% more accurate overall than some of the most popular methods in the field. The proposed fFRI is able to predict B-factors for α-carbons of the HIV virus capsid (313 236 residues) in less than 30 seconds on a single processor using only one core. Finally, we demonstrate the application of FRI and aFRI to protein domain analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Brominated carbon black: An EDXD study

An energy dispersive X-Ray study of pure and brominated carbon black was carried out. The analysis of the diffraction patterns reveals that the low bromine load (ca.1% mol) is trapped into the structure, without significantly modifying it. This allows the application of the difference methods, widely tested for electrolyte solutions, inorganic matrices containing metals and isomorphic substitutions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Instantaneous, parameter-free methods to define a solute’s hydration shell

A range of methods are presented to calculate a solute’s hydration shell from computer simulations of dilute solutions of monatomic ions and noble gas atoms. The methods are designed to be parameter-free and instantaneous so as to make them more general, accurate, and consequently applicable to disordered systems. One method is a modified nearest-neighbor method, another considers solute-water Lennard-Jones overlap followed by hydrogen-bond rearrangement, while three methods compare various combinations of water-solute and water-water forces. The methods are tested on a series of monatomic ions and solutes and compared with the values from cutoffs in the radial distribution function, the nearest-neighbor distribution functions, and the strongest-acceptor hydrogen bond definition for anions. The Lennard-Jones overlap method and one of the force-comparison methods are found to give a hydration shell for cations which is in reasonable agreement with that using a cutoff in the radial distribution function. Further modifications would be required, though, to make them capture the neighboring water molecules of noble-gas solutes if these weakly interacting molecules are considered to constitute the hydration shell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗